Plan Review Details - Permit 07020357
| Plan Review Stops For Permit 07020357 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-02-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-02-15 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-02-15 |
Time |
17:27 |
Sent To |
|
|
| Notes |
| 2007-02-15 17:41:00 | DENIED BY BUILDING | | | | | | 1) THE MAXIMUM DESIGN PRESSURE FOR THE SYSTEM ON PAGE | | | 38 IS 60 PSF, WHICH IS TOO LOW FOR THE CORNERS WHICH | | | REQUIRE 89 PSF. THE LIMITATION NUMBER 7 ON PAGE 40 OF | | | THE PRODUCT APPROVAL ALLOWS ENHANCED FASTENING TO | | | INCREASE THE PRESSURE. HOWEVER, TO DO THIS THE | | | LIMITATION REQUIRES THAT RAS 117 CALCULATIONS MUST BE | | | DONE BY AN ARCHITECT, ENGINEER OR REGISTERED ROOFING | | | CONSULTANT AS STATED IN THE FIRST REVIEW. SUBMIT THE | | | SIGNED AND SEALED RAS 117 CALCULATIONS AS REQUIRED BY | | | THE PRODUCT APPROVAL. | | | | | | 2) THE VALUE OF THE JOB IS BASED ON COSTS FROM ICC OR | | | MARSHALLS AND SWIFT ESTIMATING GUIDE. IT DOES NOT | | | MATTER WHO THE JOB IS FOR. THE VALUE HAS BEEN ADJUSTED | | | ACCORDINGLY. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-02-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-02-14 |
Time |
07:01 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-02-14 |
Time |
06:41 |
Sent To |
|
|
| Notes |
| 2007-02-14 07:00:50 | DENIED BY BUILDING | | | | | | 1) THE SYSTEM THAT WAS SELECTED ON PAGE 5 OF THE | | | CERTAINTEED MODIFIED ROOFING NOA HAS A MAXIMUM DESIGN | | | PRESSURE OF -45 PSF WHICH IS TOO LOW FOR THE PERIMETER | | | AND CORNER AREAS. THE PERIMETER REQUIRES -59.2 PSF AND | | | CORNERS REQUIRE -89 PSF. THE SELECTED SYSTEM ALSO HAS | | | LIMITATION NUMBER 9, WHICH DOES NOT ALLOW THE DESIGN | | | PRESSURES TO BE INCREASED BY ENHANCED FASTENING. SEE | | | LIMITATIONS ON PAGE 40. | | | NOTE: OTHER SYSTEMS DO ALLOW FOR INCREASED DESIGN | | | PRESSURES BY ENHANCED FASTENING (SEE LIMITATION NUMBER | | | 7). HOWEVER, THIS REQUIRES RAS 117 CALCULATIONS THAT | | | HAVE BEEN DONE BY AN ARCHITECT, ENGINEER OR REGISTERED | | | ROOF CONSULTANT. | | | | | | 2) THE VALUE OF THE WORK IS TOO LOW. PLEASE CHANGE TO | | | ADEQUATE VALUE. | | | | | | PLEASE CIRCLE THE APPROPRIATE ITEMS IN INK, RATHER THAN | | | HIGHLIGHTING. THE HIGHLIGHTER DOES NOT SHOW UP WHEN | | | COPIED FOR RECORD KEEPING. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
|