| Plan Review Stops For Permit 07020194 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-09-10 |
|
|
Cont ID |
UTICA |
| Sent By |
jjohnsto |
Date |
2007-09-10 |
Time |
09:55 |
Rev Time |
2.00 |
| Received By |
jjohnsto |
Date |
2007-09-10 |
Time |
09:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-07-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-07-31 |
Time |
07:22 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2007-07-31 |
Time |
07:17 |
Sent To |
PC |
|
| Notes |
| 2007-07-31 07:29:26 | BUILDING PLAN REVIEW | | | PERMIT: 07020194 | | | ADD: 2410 METROCENTRE BLVD.LASZLO HARANGOZO | | | CONT: | | | TEL: (703)843-1614 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RDREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) COVERSHEET A0.1 PLEASE SEE LISTED UNDER PROJECT TEAM | | | ERIC HAFER PE STILL HAS THE COMPANY NAME LISTEDNATIONAL | | | DESIGN CONSULTANT: ERIC HAFER & ASSOCIATES P A) | | | 471.023 F.S.CERTIFICATE OF | | | AUTHORIZATION.THE TITLE BLOCK FOR ANY | | | SHEET BEARING THE NAME OF AN ENGINEER | | | PRACTICING UNDER A FICTITIOUS NAME, A | | | CORPORATION, OR A PARTNERSHIP, OFFERING ENGINEERING | | | SERVICES, SHALL INCLUDE THE CERTIFICATE OF | | | AUTHORIZATION NUMBER. | | | ADD THE NUMBER TO EACH SHEET.THIS MAY | | | BE ADDED BY HAND. | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-06-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-06-13 |
Time |
16:00 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2007-06-13 |
Time |
15:38 |
Sent To |
PC |
|
| Notes |
| 2007-06-13 16:07:35 | BUILDING PLAN REVIEW | | | PERMIT: 07020194 | | | ADD: 2410 METROCENTRE BLVD.LASZLO HARANGOZO | | | CONT: | | | TEL: (703)843-1614 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1STREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) SHEET A0.1 NEW COMMENT TYYPE OF CONSTRUCTION, THE | | | TABLE 601 WOULD READ THE CURRENT | | | 2004 BUILDING TYPES BUT LISTED IS" TYPE V- UNPROTECTED | | | FULLY SPRINKLED, (PER ORIGINAL BUILDING SHELL | | | DRAWINGS) | | | THE CONVERSION FROM THE 2001 TYPE V-UNPROTECTED FULLY | | | SPRINKLED TO THE 2004/2006 FBC EQUALLS TO A | | | TYPE III-B SPRINKLED BUILDING. PLEASE CORRECT. | | | | | | 3) SEE ELECTRICAL COMMENT# 3 ABOUT ERIC HAFER IS | | | MISSING:471.023 F.S.CERTIFICATE OF AUTHORIZATION. | | | THE TITLE BLOCK FOR ANY | | | SHEET BEARING THE NAME OF AN ENGINEER PRACTICING UNDER | | | A FICTITIOUS NAME, A CORPORATION, OR A PARTNERSHIP, | | | OFFERING ENGINEERING SERVICES, SHALL INCLUDE THE | | | CERTIFICATE OF AUTHORIZATION NUMBER. ADD THE NUMBER TO | | | EACH SHEET.THIS MAY BE ADDED BY HAND. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-03-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-03-12 |
Time |
14:27 |
Rev Time |
3.55 |
| Received By |
jwitmer |
Date |
2007-03-12 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2007-03-12 15:28:20 | BUILDING PLAN REVIEW | | | PERMIT: 07020194 | | | ADD: 2410 METROCENTRE BLVD.LASZLO HARANGOZO | | | CONT: | | | TEL: (703)843-1614 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1STREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2 ) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF | | | THE COURT. | | | NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS | | | NOT ACTUALLY | | | COMMENCED WITHIN 90 DAYS AFTER THE RECORDING THEREOF, | | | SUCH NOTICE IS | | | NULL & VOID. NOTE: 713.13(6)THE POSTING OF THE NOTICE | | | OF COMMENCEMENT | | | AT THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3) SHEET A0.1 PLANS INDICATE THEY WERE DESIGNED TO THE | | | FLORIDA BUILDING CODE, WHICH EDITION? | | | | | | 4) SHEET A0.1 PLANS INDICATE THIS IS A BUSINESS | | | OCCUPANCY, CONFIRMING THE STUDENTS THAT WILL ENROLL IN | | | THIS PROGRAM WILL BE CONSIDERD | | | ADULTS AND YOUTH IN THE 12TH GRADE OR LOWER? | | | | | | 5) CURRENTLY THE PLANS ARE IN FOR A PLAN REVIEW ONLY, | | | BUT ONCE THEY ARE IN FOR | | | PERMIT THEY WILL NEEED TO BE SIGNED AND SEALED THE | | | DESIGNER OF RECCORD, | | | ORIGINAL SIGNATURES WILL BE REQUIRED, WITH RAISED | | | SEAL. | | | | | | PLANS, SPECIFICATIONS, REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND | | | BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | 6) SHEET A2.1 DOOR # 12 APPEARS TO BE AN EXISTING DOOR | | | AND FRAME, INSPECTOR TO VERIFY THIS IS A 45 MIN (3/4 | | | HR) RATED DOOR ASSEMBLY. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2007-11-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-19 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-19 |
Time |
11:54 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-09-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-09-04 |
Time |
17:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-09-04 |
Time |
17:25 |
Sent To |
|
|
| Notes |
| 2007-09-04 17:25:28 | NEW ENERGY CALCS BROUGHT IN BY THE ARCHITECT. | | | OK>. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-08-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-28 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-28 |
Time |
15:44 |
Sent To |
|
|
| Notes |
| 2007-08-28 17:33:07 | 2007-08-28 17:33:07 | | | | | | ** DENIED 4TH REVIEW** | | | | | | 1) NOTE: PLEASE SEE THE ENERGY CALCULATIONS SUBMITTED | | | STATES THE METHOD OF CONTROLS AS *MANUAL ON/OFF* WHICH | | | IS NOT POSSIBLE WHEN LIGHTING ON PLANS ARE AUTOMATED. | | | PLEASE OBTAIN NEW ENERGY CALCULATIONS WITH THE CORRECT | | | METHODS CHOSEN TO COORDINATE WITH THE PLANS AND | | | CONTROLS SHOWN. | | | PLEASE KNOW THE OPTIONS ARE ON THE FORMS WHEN DATA IS | | | BEING CHOSEN. | | | PLEASE ALSO SEE THE CERTIFICATION SHEETS ALSO NEED THE | | | OWNER AGENT TO SIGN SHEETS. | | | 13-103.1.1.1, 13-415.C.1 (AS SUBMITTED) | | | | | | ** IF NEW ENERGY CALCULATIONS CAN BE BROUGHT IN AS SOON | | | AS POSSIBLE, THIS WOULD HELP ALLEVIATE ANY RESUBMISSION | | | OF PLANS AND DELAYING POSSIBLE ISSUANCE OF PERMIT IF | | | ALL OTHER TRADES ARE OK. | | | PLEASE KNOW AS NEW ENERGY CALCULATIONS WERE SUBMITTED, | | | THE MECHANICAL REVIEWER WILL STILL REVIEW FOR CODE | | | COMPLIANCE. IF NO CHANGES ARE NEEDED FOR MECH REVIEW, | | | THEN ONLY ADDRESS THIS ABOVE COMMENT AT THIS TIME. | | | | | | | | | PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-07-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-07-02 |
Time |
18:26 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-07-02 |
Time |
17:05 |
Sent To |
I |
|
| Notes |
| 2007-07-02 18:27:08 | 2007-07-02 18:27:08 | | | ** UNSAT3RD REVIEW** | | | ** 1ST REVIEW UNDER PERMIT APPLICATION** | | | | | | ** PLEASE SEE THERE ARE NOTES FROM THE PREVIOUS REVIEW | | | WHICH STILL NEED TO BE ADDRESSED ALONG WITH NEW NOTES. | | | | | | | | | 1) NOTE: *** IMPORTANT*** | | | PLEASE DO NOT ATTACHED SUPPORTING DOCUMENTS DOWN THE | | | LEFT SIDE OF PLANS. THESE SHOULD BE PLACED INTO TWO | | | SETS, FOLDER(S), SPIRAL NOTEBOOK, OR SOME OTHER FASHION | | | TO KEEP TOGETHER. THESE WERE REMOVED FROM PLANS. | | | | | | 2) NOTE PLEASE SEE MISSING INFORMATION REQUIRED ON | | | TITLE BLOCKS FOR THE ARCHITECT AND THE ARCHITECTURAL | | | FIRM.PLEASE SEE THE TITLE COVER SHEETS WHICH STILL | | | INDICATE ERIC HAFER AND ASSOCIATES PA. | | | RESPONSES MENTIONS THAT THIS WAS BEING REMOVED ON ALL | | | SHEETS, HOWEVER THIS STILL SHOWN. | | | PLEASE SEE THE FLORIDA ADMINISTRATIVE CODE 61G1-16.004 | | | AND FLORIDA STATUES 481.219 | | | * THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY | | | ANY OTHER TRADE REVIEWER. | | | | | | 3) NOTE: PLEASE SEE NEW SIGNED, DATED AND SEALED SHEETS | | | BY THE ENGINEER FOR ELECTRICAL WHICH THE RAISED SEALS | | | ARE NOT CLEAR AND VISIBLE. PLEASE SEE THE PREVIOUS | | | SHEETS DATED APRIL 07 WERE OK, HOWEVER EVEN USING A | | | LEAD DUST RUB ON SEALS, THE INFORMATION WHICH IS | | | REQUIRED TO BE CLEAR AND VISIBLE IS NOT. | | | PLEASE SEE FS 471.025, FAC 61G15-23.001. | | | | | | 4) NOTE: PLEASE SEE COMPLIANCE WITH FBC CHAPTER 13 IS | | | STILL IN QUESTION: | | | PLEASE SEE SEVERAL CIRCUITS AS NOTED ON PLANS FOR LE, | | | 26, 28 AND 30 WHICH DO NOT SEEM TO SHOW ANY LIGHTING | | | CONTROLS, OVER RIDES OR PART OF THE LCP.? | | | PLEASE SEE 13-415.1.ABC.1.1, .1.2 AND .1.3 OF THE FBC | | | CHAPTER 13. | | | ** PLEASE SEE NOTES ON PLANS MENTIONS SOME ITEMS AND | | | SOME CONTROLS HOWEVER NOT ALL INFORMATION FOR MINIMUM | | | DESIGN FOR CODE IS PRESENT. | | | PLEASE SEE THE ENERGY CALCULATIONS SUBMITTED ARE IN | | | FACT THE SAME AS PREVIOUSLY SUBMITTED. PLEASE SEE THE | | | DESIGN WATTAGE IS STILL HIGHER THAN THE ALLOWANCE. | | | PLEASE SEE THE VERSION IS STILL NOT CORRECT. PLEASE SEE | | | ALL VERSIONS WITH AN EFFECTIVE DATE AS OF DECEMBER 8TH, | | | 2006. PLEASE SEE THE 2.1 IS NO LONGER IN EFFECT. PLEASE | | | SEE THE INPUT DATA REPORTS ARE NOW NO LONGER ATTACHED. | | | **AS PREVIOUSLY NOTED** | | | PLEASE SUBMIT ENERGY CALCULATIONS/PERFORMANCE | | | CALCULATIONS PER 13-415.AB.1.1, 13-415.1.A, 13-415.1.B, | | | 13-415.1.C, 13-415.2 | | | PLEASE SEE 13-103.1.1.1 FOR DESIGNER OF RECORD TO SIGN, | | | DATE AND SEAL SAID DOCUMENTS. | | | | | | 5) NOTE:PLEASE SEE DETAIL/RISER NOTE ON TRANSFORMER | | | STILL STATES TO SEE THE SHEET E1.1 AND DETAIL 05 FOR | | | GROUNDING OF TRANSFORMER WHICH IS BLANK. THE RESPONSE | | | MENTIONS THIS IS TO BE CORRECTED AND SEE OTHER SHEET | | | HOWEVER RISER WAS NOT ADJUSTED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE INDICATE THE ATTACHMENT LOCATION FOR THE NEW | | | TRANSFORMER. | | | PLEASE SEE THE RESPONSE LETTER MENTIONS TO SEE REVISED | | | SINGLE LINE DIAGRAM WHICH SAYS TO SEE DETAIL #5 ON | | | SHEET 1.1, HOWEVER THIS DETAIL #5 IS ACTUALLY BLANK ON | | | SHEET 1.1. | | | PLEASE COORDINATE PLANS AND POSSIBLE DETAIL ON SHEET | | | 1.5. | | | PLEASE SEE 250.50, 250.30, 250.20. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | ** PLEASE BE SURE TO SEE ANY COMMENTS FROM OTHER TRADES | | | WHICH MAY AFFECT ELECTRICAL PLANS AND DESIGN CHANGES. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-07-02 17:06:27 | 2007-07-02 17:06:27 | | | PLANS REMOVED FROM INCOMING, PLANS WILL BE SENT BACK TO | | | INCOMING WAITING FOR COMM BOARD ONCE ELECTRICAL REVIEW | | | IS DONE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-04-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-04-24 |
Time |
19:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-04-24 |
Time |
17:41 |
Sent To |
|
|
| Notes |
| 2007-04-24 19:05:23 | | | | | | | ** UNSAT2ND REVIEW** | | | | | | ** PLEASE SEE THERE ARE NOTES FROM THE PREVIOUS REVIEW | | | WHICH STILL NEED TO BE ADDRESSED ALONG WITH NEW NOTES. | | | | | | | | | | | | 1) NOTE:SAME NOTE. | | | PLEASE SEE THAT PLANS HAVE ONLY BEEN SUBMITTED FOR * | | | PLAN REVIEW* AND NOT SUBMITTED FOR PERMIT APPLICATION. | | | PLEASE KNOW PLANS WILL REMAIN IN *F* STATUS FOR ALL | | | TRADES EVEN IF PLANS ARE OK. PERMIT APPLICATION FOR | | | SCOPE OF WORK, VALUE, RELEVANT CODES ETC WILL NEED TO | | | BE VERIFIED ONCE APPLICATION IS MADE. | | | | | | 2) NOTE:SAME NOTE. PLEASE SEE THERE ARE SEVERAL AREAS | | | WHERE THE INCORRECT CODES ARE REFERENCED. PLEASE SEE | | | THE STATE OF FLORIDA IS NOT UNDER THE IEC OR THE 1997 | | | SOUTH FLORIDA ENERGY CODE. | | | PLEASE SEE PLANS WHICH ARE REDLINED AT MANY OF THE | | | LOCATIONS WHICH STILL INDICATE THESE. | | | PLEASE BE SURE ALL PLANS REFLECT THE LATEST ADOPTED | | | CODES PER THE STATE OF FLORIDA. PLEASE SEE THE | | | FOLLOWING WHICH ARE CURRENTLY ADOPTED AS OF DECEMBER | | | 8TH, 2006. | | | 2004 FBC W/ 2006 REVISION. (THIS WILL AFFECT PLANS | | | SUBMITTED). | | | 2005 NFPA-70 (NEC). (THIS WILL AFFECT PLANS AS NUMEROUS | | | LOCATIONS REFLECT CODES FROM THE 1999 NFPA-70.) 2002 | | | NFPA-72 | | | 2003 NFPA-101 | | | ** THESE CODES ARE REQUIRED AT A MINIMUM FOR THIS TRADE | | | REVIEWER; OTHERS MAY BE REQUIRED PER OTHER TRADES OR | | | REVIEWER(S). | | | PLEASE SEE THERE ARE MANY AREAS ON THE PLANS WHICH | | | REFERENCE OLDER CODES FROM PREVIOUS CODES, THESE SHOULD | | | BE REVISED ACCORDINGLY. | | | | | | 3) NOTE: PLEASE SEE MISSING INFORMATION REQUIRED ON | | | TITLE BLOCKS FOR THE ARCHITECT AND THE ARCHITECTURAL | | | FIRM.THIS IS THE SAME COMMENT AS PREVIOUS REVIEW AS | | | NO LICENSE INFORMATION FOR ERIC HAFER AND ASSOCIATES PA | | | HAS BEEN SHOWN. | | | PLEASE SEE THE MISSING FIRM LICENSE NUMBER WHICH IS | | | ALSO KNOWN AS THE CERTIFICATE OF AUTHORIZATION NUMBER | | | AND ALSO THE MISSING PRINTED NAME AND PRINTED LICENSE | | | NUMBER OF THE ARCHITECT. | | | PLEASE SEE THE FLORIDA ADMINISTRATIVE CODE 61G1-16.004 | | | AND FLORIDA STATUES 481.219 | | | * THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY | | | ANY OTHER TRADE REVIEWER. | | | | | | 4) NOTE: PLEASE SEE THE PREVIOUS NOTES WITH RESPECT TO | | | CHAPTER 13. PLEASE SE THE LIGHTING ZONES AS SUBMITTED | | | ALONG WITH THE SCHEDULE TABLES DOES NOT SEEM TO BE | | | COMPLETE. MOST IS BLANK? PLEASE CLARIFY. | | | PLEASE SEE SOME OF THE AREAS AND ROOMS DO NOT INDICATE | | | ANY CONTROL DEVICES FOR AUTOMATED CONTROL OF LIGHTING | | | AND THE PROPOSED ZONED LIGHTING SYSTEM DOES NOT PROVIDE | | | ENOUGH INFORMATION. | | | PLEASE SEE THE SYMBOL LEGEND SHOULD COORDINATE WITH THE | | | SYMBOLS TO BE SHOWN ON PLANS. | | | PLEASE SHOW ALL DEVICES/OCCUPANCY SENSORS ON PLANS. | | | (COVERAGE NEEDS TO BE REVIEWED FOR LOCATIONS ETC) | | | PLEASE BE SURE TO COORDINATE THE DEVICES AS SHOWN AND | | | TO BE SHOWN ON THE LIGHTING CONTROL SHEETS WITH THAT OF | | | THE LIGHTING PLANS. PLEASE UPDATE AND REVISE ALL | | | DEVICES AND LOCATIONS. | | | PLEASE SEE THE ENERGY CALCULATIONS AS SUBMITTED UNDER | | | METHOD *C* IS NOT CLEAR HOW THE DESIGN WATTAGE AS SHOWN | | | IS SO MUCH HIGHER THAN THE EFFECTIVE AND THE | | | ALLOWANCE. | | | PLANS STILL INDICATES THE INCORRECT CODES AS REQUIRED | | | AND NOTED IN NOTE #1 AND THIS NOTE FROM PREVIOUS | | | REVIEW. | | | PLEASE ADJUST AND PLEASE PROVIDE MORE SPECIFICATIONS ON | | | PLEASE SEE THE ENERGY CODE AS STATED ON PLANS IS NOT | | | THE 2004 FBC W/ 2006 REVISIONS TO CHAPTER 13. THE STATE | | | OF FLORIDA CONTAINS ITS OWN ENERGY CODE. PLEASE SEE THE | | | PLANS STATE THE 1997 ENERGY CODE ALONG WITH THE 2004 | | | IEC. | | | PLEASE SUBMIT THE INFORMATION RELEVANT TO THE 2004 FBC | | | AND 2006 REVISIONS FOR LIGHTING CONTROLS AND LOCATIONS | | | PER 13-415.1.ABC.1.1, .1.2 AND .1.3. | | | PLEASE SEE THAT SOME DEVICES ON PLANS APPEAR TO CONTROL | | | LIGHTING, HOWEVER DOES NOT PROVIDE INFORMATION ON TYPE | | | AND OVER RIDE TIMES. SOME DEVICES ARE NOTED ON PLANS | | | AND TIMES ARE SHOWN, HOWEVER COVERAGE DOES NOT SEEM TO | | | BE PROVIDED FOR SOME OTHER AREAS. | | | PLEASE SEE NOTE ON PLANS WHICH MENTIONS HALLWAY | | | LIGHTING AND CONTROLS ARE NOTED AS EXISTING TO REMAIN, | | | HOWEVER THIS DOES NOT SEEM TO CORRELATE WITH THE OTHER | | | WORK AS SHOWN ON PLANS. | | | PLEASE CLARIFY HOW THE FIGURES AS SHOWN ON PLANS | | | INDICATE A SWITCH ON THE LOAD SIDE OF THE POWER PACK. | | | HOW WILL THESE DEVICES REACT ON AN AUTOMATIC BASIS WHEN | | | AN OCCUPANT ENTERS AN AREA IF A SWITCH IS IN THE OFF | | | POSITION? PLEASE ALSO SEE ANOTHER SCENARIO, WHERE A | | | ROOM OR AREA IS OCCUPIED, SOMEONE LEAVES AND TURNS THE | | | SWITCH OFF, THEN THIS WOULD LEAVE ANY OF THE OTHER | | | OCCUPANTS IN DARKNESS ?? | | | PLEASE SUBMIT ENERGY CALCULATIONS/PERFORMANCE | | | CALCULATIONS PER 13-415.AB.1.1, 13-415.1.A, 13-415.1.B, | | | 13-415.1.C, 13-415.2 | | | PLEASE SEE 13-103.1.1.1 FOR DESIGNER OF RECORD TO SIGN, | | | DATE AND SEAL SAID DOCUMENTS. | | | | | | 5) NOTE: NOTES WERE ADDED TO PLANS FOR VERIFICATION, | | | HOWEVER THIS INFORMATION SHOULD BE OBTAINED FROM THE | | | SITE AND PLACED ON PLANS ACCORDINGLY. | | | ** PREVIOUS NOTE ** PLEASE VERIFY NEW OR EXISTING | | | EMERGENCY LIGHTING OUTSIDE EXIT DOOR TO STAIR AREA AND | | | DOOR LOCATED TO THE PUBLIC RIGHT OF WAY. IF EXISTING, | | | PLEASE SHOW, IF NOT EXISTING, NEW WILL BE REQUIRED. | | | PLEASE SEE 2003 NFPA-101 7.8, 7.9 | | | | | | 6) NOTE:PLEASE INDICATE THE ATTACHMENT LOCATION FOR | | | THE NEW TRANSFORMER. | | | PLEASE SEE THE RESPONSE LETTER MENTIONS TO SEE REVISED | | | SINGLE LINE DIAGRAM WHICH SAYS TO SEE DETAIL #5 ON | | | SHEET 1.1, HOWEVER THIS DETAIL #5 IS ACTUALLY BLANK ON | | | SHEET 1.1. | | | PLEASE COORDINATE PLANS AND POSSIBLE DETAIL ON SHEET | | | 1.5. | | | PLEASE SEE 250.50, 250.30, 250.20. | | | | | | 7) NOTE: PLEASE CLARIFY TAPPED CONDUCTORS FROM GUTTER | | | TO EACH OF THE 150A MCB DISCONNECTS AS SHOWN ON RISER | | | ON THE SECONDARY SIDE OF THE TRANSFORMER. | | | 240.21, 310.16, 240.4 | | | | | | 8) NOTE: PLEASE KNOW THAT THE LOW VOLTAGE AS SHOWN ON | | | PLANS WILL BE REQUIRED TO BE UNDER SEPARATE PERMITS. LV | | | SECURITY IS UNDER A SEPARATE PERMIT FROM OTHER LV | | | WORK. | | | PLANS PERMIT APPLICATIONS AND FEES WILL BE DUE FOR | | | THESE SYSTEMS AS NOTED. IF THERE ARE ANY QUESTIONS ON | | | THIS, PLEASE CALL TO GO OVER. | | | | | | ** PLEASE KNOW THAT DUE TO SOME INFORMATION NOT | | | SUBMITTED AT THIS TIME, REVIEW OF SOME ITEMS FOR CODE | | | COMPLIANCE CAN NOT BE DONE. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-02-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-21 |
Time |
18:00 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-20 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2007-02-21 18:01:52 | *** UNSAT *** | | | | | | | | | 1) NOTE:PLEASE SEE THAT PLANS HAVE ONLY BEEN | | | SUBMITTED FOR * PLAN REVIEW* AND NOT SUBMITTED FOR | | | PERMIT APPLICATION. PLEASE KNOW PLANS WILL REMAIN IN | | | *F* STATUS FOR ALL TRADES EVEN IF PLANS ARE OK. PERMIT | | | APPLICATION FOR SCOPE OF WORK, VALUE, RELEVANT CODES | | | ETC WILL NEED TO BE VERIFIED ONCE APPLICATION IS MADE. | | | | | | 2) NOTE: PLEASE BE SURE ALL PLANS REFLECT THE LATEST | | | ADOPTED CODES PER THE STATE OF FLORIDA. PLEASE SEE THE | | | FOLLOWING WHICH ARE CURRENTLY ADOPTED AS OF DECEMBER | | | 8TH, 2006. | | | 2004 FBC W/ 2006 REVISION. (THIS WILL AFFECT PLANS | | | SUBMITTED). | | | 2005 NFPA-70 (NEC). (THIS WILL AFFECT PLANS AS NUMEROUS | | | LOCATIONS REFLECT CODES FROM THE 1999 NFPA-70.) 2002 | | | NFPA-72 | | | 2003 NFPA-101 | | | ** THESE CODES ARE REQUIRED AT A MINIMUM FOR THIS TRADE | | | REVIEWER; OTHERS MAY BE REQUIRED PER OTHER TRADES OR | | | REVIEWER(S). | | | PLEASE SEE THERE ARE MANY AREAS ON THE PLANS WHICH | | | REFERENCE OLDER CODES FROM PREVIOUS CODES, THESE SHOULD | | | BE REVISED ACCORDINGLY. | | | | | | 3) NOTE: PLEASE SEE MISSING THE REQUIRED RAISED SEALED | | | FROM THE ARCHITECT OF RECORD PER FLORIDA ADMINISTRATIVE | | | CODE 61G1-16.003, FLORIDA STATUES 481.221. THE USE OF A | | | *RUBBER STAMP* IS NOT PERMITTED IN THE STATE OF | | | FLORIDA. | | | * THIS IS REQUIRED FOR ALL SHEETS AND WHETHER OR NOT | | | COMMENT IS MADE BY ANY OTHER REVIEWER. | | | | | | 4) NOTE: PLEASE SEE MISSING INFORMATION REQUIRED ON | | | TITLE BLOCKS FOR THE ARCHITECT AND THE ARCHITECTURAL | | | FIRM. PLEASE SEE THE MISSING FIRM LICENSE NUMBER WHICH | | | IS ALSO KNOWN AS THE CERTIFICATE OF AUTHORIZATION | | | NUMBER AND ALSO THE MISSING PRINTED NAME AND PRINTED | | | LICENSE NUMBER OF THE ARCHITECT. | | | PLEASE SEE THE FLORIDA ADMINISTRATIVE CODE 61G1-16.004 | | | AND FLORIDA STATUES 481.219 | | | * THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY | | | ANY OTHER TRADE REVIEWER. | | | | | | 5) NOTE: PLEASE SEE THE MISSING LICENSE INFORMATION FOR | | | THE ENGINEERING FIRM. PLEASE SEE THE MISSING | | | CERTIFICATE OF AUTHORIZATION NUMBER PER FLORIDA | | | ADMINISTRATIVE CODE 61G15-23.002 AND FLORIDA STATUES | | | 471.023. | | | * THIS IS REQUIRED FOR ALL SHEETS WHETHER OR NOT | | | COMMENT IS MADE BY OTHER TRADES. | | | | | | 6) NOTE: PLEASE SEE THE SEAL USED ON SOME SHEETS FOR | | | THE ENGINEER OF RECORD IS LONGER VALID FOR USE IN THE | | | STATE OF FLORIDA. PLEASE SEE THAT THE WORDING OF | | | *CERTIFICATE* IN SEAL WAS REQUIRED TO BE CHANGED TO THE | | | WORDING OF *LICENSE* IN FEB 04. THE RULE 61G15-23.001 | | | WAS EXTENDED TO DECEMBER 31ST, 2005 HOWEVER ALL PLANS | | | AFTER THAT DATE MAY NOT USE THE OLD SEAL. THIS IS ONLY | | | THE CASE ON SOME OF THE SHEETS IN ONE OF THE SETS | | | SUBMITTED. PLEASE CORRECT. | | | ** THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY | | | OTHER TRADES. | | | | | | 7) NOTE: PLEASE SEE THE ENERGY CODE AS STATED ON PLANS | | | IS NOT THE 2004 FBC W/ 2006 REVISIONS TO CHAPTER 13. | | | THE STATE OF FLORIDA CONTAINS ITS OWN ENERGY CODE. | | | PLEASE SEE THE PLANS STATE THE 1997 ENERGY CODE ALONG | | | WITH THE 2004 IEC. | | | PLEASE SUBMIT THE INFORMATION RELEVANT TO THE 2004 FBC | | | AND 2006 REVISIONS FOR LIGHTING CONTROLS AND LOCATIONS | | | PER 13-415.1.ABC.1.1, .1.2 AND .1.3. | | | PLEASE SEE THAT SOME DEVICES ON PLANS APPEAR TO CONTROL | | | LIGHTING, HOWEVER DOES NOT PROVIDE INFORMATION ON TYPE | | | AND OVER RIDE TIMES. SOME DEVICES ARE NOTED ON PLANS | | | AND TIMES ARE SHOWN, HOWEVER COVERAGE DOES NOT SEEM TO | | | BE PROVIDED FOR SOME OTHER AREAS. | | | PLEASE SEE NOTE ON PLANS WHICH MENTIONS HALLWAY | | | LIGHTING AND CONTROLS ARE NOTED AS EXISTING TO REMAIN, | | | HOWEVER THIS DOES NOT SEEM TO CORRELATE WITH THE OTHER | | | WORK AS SHOWN ON PLANS. | | | PLEASE CLARIFY HOW THE FIGURES AS SHOWN ON PLANS | | | INDICATE A SWITCH ON THE LOAD SIDE OF THE POWER PACK. | | | HOW WILL THESE DEVICES REACT ON AN AUTOMATIC BASIS WHEN | | | AN OCCUPANT ENTERS AN AREA IF A SWITCH IS IN THE OFF | | | POSITION? PLEASE ALSO SEE ANOTHER SCENARIO, WHERE A | | | ROOM OR AREA IS OCCUPIED, SOMEONE LEAVES AND TURNS THE | | | SWITCH OFF, THEN THIS WOULD LEAVE ANY OF THE OTHER | | | OCCUPANTS IN DARKNESS ?? | | | PLEASE SUBMIT ENERGY CALCULATIONS/PERFORMANCE | | | CALCULATIONS PER 13-415.AB.1.1, 13-415.2 | | | PLEASE SEE 13-103.1.1.1 FOR DESIGNER OF RECORD TO SIGN, | | | DATE AND SEAL SAID DOCUMENTS. | | | | | | 8) NOTE: PLEASE SEE THAT THE COLOR CODING FOR 277/480V | | | SYSTEMS SHALL BE BROWN, PURPLE, YELLOW. PLEASE KNOW | | | SYSTEMS LOCATED IN THE CITY OF WEST PALM BEACH ARE | | | CURRENTLY UNDER THIS COLOR CODING FOR FEEDERS DUE TO | | | PREVIOUS LOCAL AMENDMENTS. | | | * PER NEC, *ORANGE* COLOR IS FOR A HIGH-LEG OF DELTA | | | SYSTEM. | | | FBC ADMIN SECTION 104.6 | | | | | | 9) NOTE: PLEASE SPECIFY THE MINIMUM LEVELS FOR HORN AND | | | STROBE DEVICES ON PLANS. IT IS KNOW THAT THERE WILL BE | | | SEPARATE PERMIT FOR ANY FIRE ALARM SYSTEM OR DEVICE | | | WORK; HOWEVER THE BASE PLANS ARE REQUIRED TO SHOW THIS | | | INFORMATION AT THIS TIME. PLEASE SEE FBC 11-4.28.1, .2, | | | AND .3(4) FOR MINIMUM LEVELS TO BE ON PLANS. | | | | | | 10) NOTE: PLEASE SEE THE MAIN ELECTRICAL ROOM EVEN AS | | | EXISTING IS INDICATING THE DOOR SWING INWARDS. PLEASE | | | VERIFY THIS. PLEASE SEE 110.26 OF THE NEC. | | | PLEASE SEE THAT THE DOOR SWING IS REQUIRED TO SWING | | | OUT. PLEASE ADJUST. DUE TO THE LEVEL OF WORK AND | | | ALTERATION, DOOR SWING WILL BE REQUIRED TO BE CHANGED | | | IF NOT ALREADY IN THE SWING OUT POSITION. PLEASE BE | | | SURE TO SEE POSSIBLE SWING AND TRAVEL OF DOOR SWING IN | | | EXIT CORRIDOR. PLEASE SEE THAT THE DOOR SWING MAY BE | | | REQUIRED TO OPEN IN THE PATH OF EGRESS AND ON 180 | | | DEGREE HINGES? PLEASE ALSO SEE OTHER MAXIMUM DOOR WIDTH | | | IN HALL WHEN IN OPEN POSITION. THIS MAY NOT BE A | | | BUILDING REVIEW COMMENT AT THIS TIME, HOWEVER AS THE | | | DOOR SWING WILL BE REQUIRED TO BE CHANGED, AND THEN | | | PLEASE BE SURE TO CHECK WITH BUILDING CODE FOR | | | ALLOWANCES. | | | ** THIS IS A LIFE SAFETY ISSUE FOR EXITING FROM THE | | | ELECTRICAL ROOM DURING AN EMERGENCY. | | | | | | 11) NOTE: PLEASE VERIFY NEW OR EXISTING EMERGENCY | | | LIGHTING OUTSIDE EXIT DOOR TO STAIR AREA AND DOOR | | | LOCATED TO THE PUBLIC RIGHT OF WAY. IF EXISTING, PLEASE | | | SHOW, IF NOT EXISTING, NEW WILL BE REQUIRED. PLEASE SEE | | | 2003 NFPA-101 7.8, 7.9 | | | | | | 12) NOTE: PLEASE INDICATE THE ATTACHMENT LOCATION FOR | | | THE NEW TRANSFORMER. | | | PLEASE SEE 250.50, 250.30, 250.20. | | | | | | 13) NOTE: PLEASE SEE 250.66 FOR THE CORRECT SIZING OF | | | THE GROUNDING ELECTRODE CONDUCTOR FOR THE TRANSFORMER. | | | | | | 14) NOTE: PLEASE SEE THE FEEDERS ON THE RISER SHOW A | | | NEUTRAL CONDUCTOR FROM THE MDP TO THE NEW TRANSFORMER. | | | HOW IS THIS POSSIBLE WHEN THIS IS A SEPARATELY DERIVED | | | SYSTEM AND THE TRANSFORMER CREATES ITS OWN NEW NEUTRAL | | | POINT? | | | PLEASE CLARIFY. | | | 250.20, 250.30 ETC | | | | | | 15) NOTE: PLEASE PROVIDE A MORE DETAILED LOAD SUMMARY. | | | : LOADS ARE CURRENTLY SHOWN AT CONNECTED LOADS FOR | | | ALL. | | | PLEASE SEE 220.12, 220.14, 220.42, 220.44 ETC. PLEASE | | | INDICATE ALL CONTINUOUS LOADS AT 125%. 215.3, 230.42. | | | | | | 16) NOTE: PLEASE NOTE OR PROVIDE INFORMATION IF THE | | | EXISTING MAIN AT 277/480 AND OVER 1000AMPS CONTAINS GF | | | PROTECTION. | | | 240.13, 230.95 ONLY NEEDS TO NOTE IF EXISTING. | | | | | | ** PLEASE KNOW THAT DUE TO SOME INFORMATION NOT | | | SUBMITTED AT THIS TIME, REVIEW OF SOME ITEMS FOR CODE | | | COMPLIANCE CAN NOT BE DONE. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-02-19 10:10:00 | IN ELEC FOR REVIEW. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2007-09-10 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-09-10 |
Time |
17:17 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-09-10 |
Time |
16:53 |
Sent To |
B |
|
| Notes |
| 2007-09-10 17:17:23 | *****APPROVED***** | | | | | | | | | PLAN SHEETSA2.5, F1.1, F2.1, E2.3 AND E2.6 WERE | | | STAMPED, INTIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-07-26 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-07-26 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-07-26 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2007-07-26 16:11:05 | *****PROVISO***** | | | | | | ALL COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADDRESSED;HOWEVER THE APPROPIATE PLAN SHEET(S) | | | WILL BE STAMPED WHEN ALL OTHER PLAN REVIEWS HAVE BEEN | | | SATISFIED | | | | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-05-07 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-05-07 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-05-07 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2007-05-07 14:06:04 | *****PROVISO***** | | | | | | ALL COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADDRESSED;HOWEVER THE APPROPIATE PLAN SHEET(S) | | | WILL BE STAMPED WHEN ALL OTHER PLAN REVIEWS HAVE BEEN | | | SATISFIED | | | | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-03-19 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-03-19 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-03-19 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2007-03-19 16:24:13 | *****DENIED***** | | | | | | | | | | | | 1. NFPA 101 (2003 EDITION) AND THE FLORIDA FIRE | | | PREVENTION CODE (2004) EDITION) SHALL BE REFERENCED. | | | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 3.CONSTRUCTION AND/OR DEMOLITION OPERATIONS SHALL | | | NOT INTERFERE OR HINDER EMERGENCY RESPONSE ACCESS TO | | | THE SAID PROPERTY OR VICINITY THEREOF (INCLUDING FIRE | | | LANES). | | | | | | 4.PLEASE INDICATE IF THE BUILDING OR PORTIONS OF THE | | | BUILDING WILL BE OCCUPIED DURING THE PROPOSED SCOPE OF | | | WORK.IF SO,THIS WILL BE PERMITTED ONLY WHERE | | | REQUIRED MEANS OF EGRESS AND REQUIRED FIRE PROTECTION | | | FEATURES ARE IN PLACE AND MAINTAINED, OR WHERE | | | ALTERNATIVE LIFE SAFETY MEASURES ACCEPTABLE TO THE AHJ | | | ARE IN PLACE. | | | | | | 5.INTERIOR WALL AND CEILING FINISH MATERIALS SHALL | | | BE CLASS A OR CLASS B IN EXITS AND EXIT ACCESS | | | CORRIDORS,CLASS A, CLASS B, OR CLASS C IN ALL OTHER | | | AREAS.PLEASE SPECIFY. | | | | | | 6.PROVIDE A LIFE SAFETY PLAN SHEET WHICH INDICATES | | | THE TRAVEL DISTANCE TO THE EXIT(S).ALSO INDICATE THE | | | LOCATION OF THE 2A:10BC FIRE EXTINGUISHERS WHICH | | | SATISFY THE 75 ' TRAVEL DISTANCE REQUIREMENT. | | | | | | 7.IF THE EXISTING FIRE ALARM AND/OR FIRE SPRINKLER | | | SYSTEM IS/ARE MODIFIED DUE TO THE SCOPE OF WORK, | | | SEPARATE PLANS AND PERMIT WILL BE REQUIRED. | | | | | | 8.PLEASE NOTE THE DIFFERENCE IN THE LAYOUT OF THE | | | FACIAL ROOM [116] ON SHEET E-2.2 AND E-2.6 COMPARED TO | | | E-2.1 ANDE-2.3. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS WHEN RE-SUBMITTING, | | | INCLUDE A RESPONSE LETTER INDICATING HOW/WHERE EACH | | | ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-12-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-12 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-12 |
Time |
16:28 |
Sent To |
M |
|
| Notes |
| 2007-12-12 16:28:46 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-11-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-27 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-27 |
Time |
09:53 |
Sent To |
M |
|
| Notes |
| 2007-11-27 09:54:17 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-11-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-07 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-07 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2007-11-07 08:58:10 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-08-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-03 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-03 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2007-08-28 15:13:08 | TO "COMM" BD#40 | | 2007-08-03 14:55:38 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-06-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-21 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-21 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2007-07-09 14:14:52 | TO "COMM" BD#18 | | 2007-06-21 15:59:53 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-04-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-23 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-23 |
Time |
09:09 |
Sent To |
|
|
| Notes |
| 2007-04-23 09:17:16 | TO "COMM" BD#58 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-03-19 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-03-19 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-02-12 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2007-02-19 07:52:22 | TO COMM BOARD SPACE #54 | | 2007-02-12 08:45:01 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2007-12-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-12-13 |
Time |
08:15 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-12-13 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2007-12-13 08:16:29 | REVISION TO MECH. PLAN PAGE M2.1 AND SUBMITTEL LETTER | | | FOR DUCT SIZE CHANGE FROM 26"X24" TO 24"X24". |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2007-11-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-30 |
Time |
10:45 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-11-30 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2007-11-30 10:46:46 | MECHANICAL REVISION TO PAGE M2.1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2007-11-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-14 |
Time |
15:19 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-11-14 |
Time |
15:19 |
Sent To |
E |
|
| Notes |
| 2007-11-14 15:34:52 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | MECHANICAL REVISION TO PAGE M2.1. | | | *** DENIED *** | | | 1) THE EXHAUST MAY NOT TERMINATE WITHIN 10 FT. OF AN | | | INTAKE OPENING, SEE 2004 FBC/M 401.5.1. PLEASE | | | CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-09-04 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-09-04 |
Time |
13:41 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-09-04 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2007-09-04 13:42:16 | APPROVED MECH. PLANS PASSED REVIEW ON 7-10-07. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-07-10 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-10 |
Time |
12:22 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-07-10 |
Time |
12:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-04-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-04-30 |
Time |
14:42 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-04-30 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2007-04-30 14:46:23 | ** FOR PLAN REVIEW ONLYNOT FOR PERMIT ** | | | *** DENIED *** | | | 1) SEE ELECTRICAL REVIEW NOTE #2, PLEASE CORRECT PLANS | | | PAGE PME1.1. | | | | | | 2) MECHANICAL PLANS ARE OK AT THIS TIME. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-27 |
Time |
11:57 |
Rev Time |
1.30 |
| Received By |
tgordon |
Date |
2007-02-27 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2007-02-27 12:30:21 | ** FOR PLAN REVIEW, NOT FOR PERMIT ** | | | *** DENIED *** | | | 1) CERTIFICATE OF AUTHORIZATION NUMBER FOR THE | | | ENGINEERING BUSINESS (POLARIS) MUST APPEAR IN THE TITLE | | | BLOCK, SEE FAC 61G15-23.002. | | | | | | 2) THE 34X16 RETURN AIR TRANSFER DUCT FROM CLASSROOM | | | 107 TO SHAMPOO 103 IS PENETRATING FIRE RATED WALLS AND | | | WILL NEED FIRE DAMPERS, SEE 2004 FBC/M 607.5.2. ALSO | | | PLEASE EXPLAIN WHAT ( --- CBBC ) IS, I COULD NOT FIND | | | IN THE ABBREVIATIONS. | | | | | | 3) THE 9" SUPPLY AIR DUCT FROM THE CORRIDOR TO THE | | | BOOKSTORE 116 WILL NEED A FIRE DAMPER ALSO, SEE 2004 | | | FBC/M 607.5.3, 2, 2.3. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-09-10 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-09-10 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-09-10 |
Time |
14:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2007-07-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-07-17 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-07-17 |
Time |
07:31 |
Sent To |
|
|
| Notes |
| 2007-07-17 07:35:27 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | MUNICIPAL CODE | | | | | | ********FROM PREVIOUS REVIEWS******** | | | | | | 1. SHTS A0.1 THRU A5.3 PLANS SHALL BE SEALED BY AN | | | IMPRESSION TYPE SEAL. ALL INFORMATION REQUIRED FOR SEAL | | | TO BE IMPRESSED ON TO EACH SHEET. THE BUSINESS LICENSE | | | OF THE ARCHITECTURAL FIRM SHALL INDICATE THEIR | | | CERTIFICATE OF AUTHORIZATION, (BUSINESS LICENSE | | | NUMBER), IN THE TITLE BLOCK OF EACH SHEET. FAC | | | 61G1-16.001, 61G1-16.002, 61G1-16.004(2) AND FS | | | 481.219, 481.2055. | | | ****RESPONSE NOTED, BUT THE ARCHITECTURAL FIRM LICENSE | | | NUMBER, (CERTIFICATE OF AUTHORIZATION), IS NOT SHOWN IN | | | THE TITLE BLOCK. | | | ********RESPONSE NOTED, BUT NATIONAL DESIGN CONSULTANT: | | | ERIC HAFNER & ASSOCIATES P. A. IS STILL REFERENCED ON | | | SHT A0.1. DELETE ALL REFERENCES OF THE ARCHITECTURAL | | | FIRM FROM PLANS OR SUBMIT FIRM LICENCE NUMBER. | | | | | | 2. OK | | | 3. OK | | | 4. OK | | | 5. OK | | | 6. OK | | | 7. OK | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-06-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-06-06 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-06-05 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2007-06-06 08:44:14 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | MUNICIPAL CODE | | | | | | 1. SHTS A0.1 THRU A5.3 PLANS SHALL BE SEALED BY AN | | | IMPRESSION TYPE SEAL. ALL INFORMATION REQUIRED FOR SEAL | | | TO BE IMPRESSED ON TO EACH SHEET. THE BUSINESS LICENSE | | | OF THE ARCHITECTURAL FIRM SHALL INDICATE THEIR | | | CERTIFICATE OF AUTHORIZATION, (BUSINESS LICENSE | | | NUMBER), IN THE TITLE BLOCK OF EACH SHEET. FAC | | | 61G1-16.001, 61G1-16.002, 61G1-16.004(2) AND FS | | | 481.219, 481.2055. | | | ****RESPONSE NOTED, BUT THE ARCHITECTURAL FIRM LICENSE | | | NUMBER, (CERTIFICATE OF AUTHORIZATION), IS NOT SHOWN IN | | | THE TITLE BLOCK. | | | | | | 2. OK | | | | | | 3. OK | | | 4. OK | | | 5. OK | | | 6. OK | | | 7. OK | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-03-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-03-10 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-03-10 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2007-03-10 10:57:59 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | MUNICIPAL CODE | | | | | | 1. SHTS A0.1 THRU A5.3 PLANS SHALL BE SEALED BY AN | | | IMPRESSION TYPE SEAL. ALL INFORMATION REQUIRED FOR SEAL | | | TO BE IMPRESSED ON TO EACH SHEET. THE BUSINESS LICENSE | | | OF THE ARCHITECTURAL FIRM SHALL INDICATE THEIR | | | CERTIFICATE OF AUTHORIZATION, (BUSINESS LICENSE | | | NUMBER), IN THE TITLE BLOCK OF EACH SHEET. FAC | | | 61G1-16.001, 61G1-16.002, 61G1-16.004(2) AND FS | | | 481.219, 481.2055. | | | | | | 2. ALL P,M,E SHEETS. THE CERTIFICATE OF AUTHORIZATION | | | FOR THE ENGINEERING COMPANY SHALL BE INDICATED IN THE | | | TITLE BLOCK ON EACH SHEET. FAC 61G15-23.002(2) & FS | | | 471.025. | | | | | | 3. SUBMIT A FLOOR PLAN PLAN VIEW FOR THE PLUMBING | | | PIPING. SHOW THE CONNECTION POINT FOR THE WATER AND FOR | | | THE SANITARY PLUMBING LINES, SECTIONS 106.1.2 AND | | | 106.3.5.1.3(3)(4)(10). | | | | | | 4. SUBMIT THE SANITARY RISER DIAGRAM IN AN ISOMETRIC | | | FORM THAT REFLECTS THE LAYOUT OF THE FIXTURES AND THE | | | RELATED PIPING AS IT WILL BE INSTALLED, (FLOOR PLAN). | | | INDICATE THE HAIR INTERCEPTOR LOCATIONS. SECTION | | | 106.1.1. | | | | | | 5. SUBMIT THE WATER RISER ISOMETRIC IN AN ISTOMETRIC | | | FORM THAT REFLECTS THE LAYOUT OF THE FIXTURES AND FLOOR | | | PLAN. SHOW THE SHUT OFF VALVES FOR THE HOSE BIBBS ON | | | THE SUPPLY PIPES REQUIRED IN SECTION 606.2(2) & SECTION | | | 106.3.5.1.3(3)(10)(13). | | | | | | 6. SHT P1.2 GREASE WASTE RISER. IN THE REMOVAL OF ANY | | | PART OF A DRAINAGE SYSTEM, DEAD ENDS SHALL BE | | | PROHIBITED. SECTION 704.5. (SEE DEFINITION). | | | | | | 7. SHT P1.2 IF THE GREASE INTERCEPTOR WILL BE | | | ABANDONED, IT SHALL BE EMPTIED, CLEANED OUT AND | | | REMOVED, OR EMPTIED, CLEANED OUT AND THE TOP REMOVED, | | | BOTTOM BROKEN TO ALLOW DRAINAGE AND FILLED WITH CLEAN | | | SAND OR OTHER SUITABLE MATERIAL. PLEASE INDICATE | | | METHOD. MUMICIPAL CODE SECTION 90-123(E)(1)(2)(3). | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|