| Plan Review Stops For Permit 07020178 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-09-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-09-19 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-09-19 |
Time |
15:42 |
Sent To |
PC |
|
| Notes |
| 2008-09-19 15:43:23 | DOOR/WINDOW REVISION ON EXISTING HOUSE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-04-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-04-14 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-04-14 |
Time |
07:50 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-12-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-12-20 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-12-20 |
Time |
12:37 |
Sent To |
PC |
|
| Notes |
| 2007-12-20 16:59:18 | RESIDENTIAL ADDITION, BUILDING REVIEW THIRD CHECKLIST. | | | REVIEW UNDER FBC 2004 WITH 2006 REVISIONS. | | | | | | 1- CONNECTORSPECIFIED ON SHEET 11 FOR THE END OF | | | GIRDER TRUSSES RESTING ON THE MASONRY WALL IS | | | INCORRECT. IT DOESN'T MATCH CONDITIONS SHOWN ON PLANS. | | | HOW CAN YOU BOLT THE STEEL CONNECTOR TO THE CONCRETE | | | COLUMN?.ALSO, THERE IS NOT TIE BEAM BELOW GIRDER | | | TRUSS. PROVIDE CORRECT DETAIL.SEC. 106.1.2 CITY | | | AMENDMENTS TO FBC 2004 TOVERIFY COMPLIANCE WITH THE | | | DESIGN LOADS OF SEC. R301 OF 2004 FLORIDA RESIDENTIAL | | | CODE. | | | | | | 2- OWES $1.66 FOR RADON FEES. | | | | | | 3- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE | | | 9B-72 FOR:ALLSIMPSON OR USP STRUCTURAL CONNECTORS | | | SPECIFIED ON ENGINEER PLANS. (REPEAT COMMENT). | | | INFORMATION SUBMITTED IS NOT AN APPROVEDPRODUCT | | | APPROVALBUT A COPY FROM THE MANUFACTURER'SCATALOG. | | | PROVIDE PROPERFLORIDA PRODUCT APPROVAL COVER PAGE AND | | | PAGE WHERE CONNECTOR IS SHOWN ONLY.NO NEED TO PROVIDE | | | COMPLETE CONNECTORS REPORT TO SAVE PAPER.GO TO | | | WWW.FLORIDABUILDING.ORG TO DOWNLOAD CORRESPONDING | | | INFORMATION. | | | | | | 4- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING)ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | LETTER FROMENGINEER STATING THAT HE REVIEW THE | | | PRODUCT APPROVAL IS NOT ACCEPTABLE BECAUSE IT DOESN'T | | | SPECIFY WHICH SPECIFIC PRODUCT APPROVALS WERE REVIEWED. | | | ENGINEER OF RECORD TO USETHE STANDARD REVIEW AND | | | APPROVED STAMP ON EACH PRODUCT APPROVAL OR PROVIDE | | | LETTER WHICH IDENTIFIES EACH SPECIFIC PRODUCT APPROVAL | | | OR NOA NUMBER REVIEWED. | | | | | | 5- TRUSS DRAWINGS: ALL ENGINEERING DETAILS, LETTERS, | | | ETC.NEED TO BE SIGNED, SEALED, DATED AND HAVE ALL THE | | | ENGINEER'S INFORMATION AS REQUIRED BY CHAPTER 471 | | | FLORIDA STATUTES AND SEC. 61G15-23.002 OF FLORIDA | | | ADMINISTRATIVE CODE. (REPEAT COMMENT). | | | | | | 6- NEW ENERGY CALCULATIONS WERE SUBMITTED: | | | A) PROVIDE CURRENT UPDATED FORM 600A-2004R. SEE | | | MECHANICAL PLAN REVIEWER COMMENTS. | | | | | | B) PREPARER TO SIGN AND DATE FORM. | | | | | | C) OWNER/AGENT TO SIGN AND DATE THE FORM. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-10-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-10-01 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-10-01 |
Time |
17:33 |
Sent To |
PC |
|
| Notes |
| 2007-10-01 18:17:24 | RESIDENTIAL ADDITION BUILDING REVIEW SECOND CHECKLIST. | | | REVIEW DONE UNDER 2004 FLORIDA RESIDENTIAL CODE AND FBC | | | 2004 WITH 2006 REVISIONS. | | | | | | 1-OWES $404.00 FOR UPDATED PERMIT VALUATION AS | | | REQUIRED BY SEC. 108.3 CITY AMENDMENTS TO FBC 2004. | | | | | | 2- ATTIC ACCESS SHOWN ON PLANS DOESN'T WORK. SEE ROOF | | | FRAMING PLANFOR ORIENTATION OF TRUSSES. ALSO,THERE | | | IS NOT HEADROOM IF ATTIC ACCESS IS TOO CLOSE TO THE | | | EXTERIOR WALL. REVISE AS REQUIRED. SEC. 106.1.2 CITY | | | AMENDMENTS TO FBC 2004. | | | | | | 3- ROOF TILE WAS CHANGED TO ROOF SHINGLES. REVISE | | | ORIGINAL DRAWINGS. CROSSING OUT PRINTS BY HAND IS NOT | | | ALLOWED. | | | IN ADDITION ENGINEER'S SIGNATURE DOESN'T MATCH | | | SIGNATURE SHOWN BY ENGINEER'S SEAL.. | | | | | | 4- SPECIFY CONNECTORS AT THE OTHER END OF WALL GIRDERS | | | RESTING ON MASONRY WALL. SEC. 106.1.2 CITY AMENDMENTS | | | TO FBC 2004 (REPEAT COMMENT). | | | | | | 5- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE | | | 9B-72 FOR: | | | A) ALL STRUCTURAL TRUSS CONNECTORS SPECIFIED ON | | | PLANS.INFORMATION SUBMITTED IS A COPY OF FROM THE USP | | | CATALOG, NOT A PRODUCT APPROVAL. PROVIDE ONLY THE | | | PRODUCT APPROVAL COVER PAGE ANDPAGE WHERE SPECIFIED | | | CONNECTORS ARE SHOWN TO SAVE TIME AND PAPER. | | | | | | 6- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING)ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004 | | | (REPEAT COMMENT). | | | | | | 7- TRUSS DRAWINGS: | | | A) ALL GENERAL DRAWINGS, DETAILS, SPECS, LETTERS, | | | ETC. NEED TO HAVE ENGINEER'SORIGINAL SEAL, SIGNATURE | | | AND DATE AS REQUIRED BY CHAPTER 471 FLORIDA STATUTE. IN | | | ADDITION ALL SHEETS NEED TO HAVE THE ENGINEER'S | | | COMPLETEINFORMATION AS REQUIRED BY FLORIDA | | | ADMINISTRATIVE CODE SEC. 61G15-23.002 (REPEAT | | | COMMENT). | | | | | | 8- FOUNDATION DESIGN BEARING CAPACITY NOTE ON SHEET #6 | | | CALLS FOR 2500 PSF SOIL BEARING CAPACITY, WHILEPAGE | | | ONE OF SOIL TEST REPORT CALLS FOR 2000PSF SOIL BEARING | | | CAPACITY. REVISE AS REQUIRED TOMATCH.(REPEAT | | | COMMENT). | | | | | | 9- PROVIDE 2 COPIES OF SOIL TEST REPORT WITH ORIGINAL | | | ENGINEER'S SIGNATURE AND SEAL.ONLY ONE WAS | | | SUBMITTED. | | | | | | 10- HURRICANE STRAP SCHEDULE.REVISE NUMBER OF NAILS | | | SPECIFIED FOR TAPL16 CONNECTOR.SEE PRODUCT APPROVAL | | | FOR CORRECT NUMBER OF NAILS. OTHERWISE PROVIDE COMPLETE | | | ENGINEERING ANALYSISIF NUMBER OF NAILS DIFFER FROM | | | THOSE TESTED AND PUBLISHED BY THE MANUFACTURER.SEC. | | | 106.1.2 CITY AMENDMENTS TO FBC 2004 (REPEAT COMMENT). | | | | | | 11- CLARIFY HANGER DETAIL TO CONCRETE COLUMN ON SHEET | | | #11. WHERE IS THIS DETAIL TAKEN PLACE AT? . HOW IS THE | | | PLATE WELDED TO CONCRETE COLUMN?. HOW ARE THE THRU | | | BOLTS INSTALLED?. SEC. 106.1.2 CITY AMENDMENTSTO FBC | | | 2004. | | | | | | 12- PROVIDE ONLY DETAILS THAT APPLY TO THIS JOB TO | | | EXPEDITE REVIEW PROCESS AND AVOID CONFLICTS. | | | | | | 13- NOTICE OF COMMENCEMENT WAS RECORDED ON 02/07/2007. | | | THIS DOCUMENT EXPIRES IF WORK IS NOT STARTED WITHIN 90 | | | DAYS OF RECORDING IT. THEREFORE, NEED RE-RECORDED | | | NOTICE OF COMMENCMENT AS REQUIRED BY SEC. 713.13 | | | FLORIDA STATUTE. | | | | | | NOTE: | | | PROVIDING A CHECKLIST RESPONSE LETTER IS HIGHLY | | | RECOMMENDED TOEXPEDITE THE REVIEW PROCESS ANDVERIFY | | | THAT ALLITEMS ARE ADDRESSED. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-03-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-03-27 |
Time |
17:51 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-03-27 |
Time |
17:39 |
Sent To |
|
|
| Notes |
| 2007-03-27 17:52:39 | BUILDING REVIEW CHECKLIST: | | | 1- ENGINEER'S NAME DOESN'T MATCHNAME THAT APPEARS ON | | | EMBOSSED SEAL.. CLARIFY/REVISE AS REQUIRED. | | | | | | 2- TOTAL ADDITION AREA IS INCORRECT. REVISE AS | | | REQUIRED. SEE DIMENSIONSON PLANS. | | | | | | 3- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD | | | (561)233-5115) AFTER PLANS ARE REVISED WITH CORRECT NEW | | | ADDITION AREA TO CHECK IF ADDITIONAL IMPACT FEES ARE | | | DUE. BRING BACK STAMPED PLANS AND PAID RECEIPT IF | | | ADDITIONAL FEES ARE DUE. | | | | | | 4- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW.ALSO, NEED TO CONSIDER WINDOWS AND DOORS | | | REPLACEMENT AND DEMOLITION COSTS. UPDATE VALUE OR IT | | | WILL ESTIMATED AS REQUIRED BY SEC. 108.3 CITY | | | AMENDMENTS TO FBC 2004. | | | | | | 5- SPECIFY ATTIC ACCESSIN NEW ADDITION AS REQUIRED BY | | | SEC. R807 OF 2004 FLORIDA RESIDENTIAL CODE. | | | | | | 6- PROVIDE DETAIL/SECTION FOR FOOTING A.FOOTING | | | SCHEDULE TYPE AND REMARKS CALL FOR STEM TYPE FOOTING, | | | WHILE FOUNDATION PLANS SHOWS MONOLITHIC TYPE. REVISE AS | | | REQUIRED. | | | | | | 7- PROVIDE COMPLETE DETAILS,SECTIONS, SPECS FOR | | | CUPOLA CONSTRUCTION. SEC. 106.1.2 CITY AMENDMENTS TO | | | FBC 2004. | | | | | | 8- DESIGNER OF RECORD TO SPECIFY SPECIFIC ROOF TILE | | | FASTENING AS REQUIRED BY SEC. 106.1.1.2 CITY AMENDMENTS | | | TO FBC 2004.PRODUCT APPROVAL IS TO SHOW COMPLIANCE | | | WITH DESIGNER OF RECORD SPECS. | | | | | | 9- PROVIDE COMPLETE DETAIL AT TOP OF STEEL COLUMN | | | RECEIVING THE TWO WALL GIRDERS. SEC. 106.1.2 CITY | | | AMENDMENTS TO FBC 2004. | | | | | | 10- PROVIDE COMPLETE SPECS FOR BOTTOM PLATE OF STEEL | | | COLUMN. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | 11- SPECIFY CONNECTORS AT THE OTHER ENDS OF WALL | | | GIRDERS RESTING ON MASONRY WALL. SEC. 106.1.2 CITY | | | AMENDMENTS TO FBC 2004. | | | | | | 12- PLEASE PROVIDE ONLY THE DETAILS AND SPECS THAT | | | APPLY TO THIS PROJECT TO EXPEDITE THE REVIEW PROCESS. | | | | | | 13- SPECIFY DESIGN PRESSURES FOR WINDOWS AND DOORS TO | | | BE REPLACED TO VERIFY PRODUCT APPROVAL COMPLIANCE. SEC. | | | 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | 14- PROVIDE PRODUCT APPROVAL AS REQUIRED BY RULE 9B-72 | | | FOR: | | | A) WINDOW MULLIONS. | | | | | | B) TRUSS STRUCTURAL CONNECTORS SPECIFIED ON PLANS. | | | | | | C) GARAGE DOOR. | | | | | | D) ROOF TILE. NOA #01-0417.09 SUBMITTED EXPIRED ON | | | 06/07/2006. NEED CURRENT ONE. | | | | | | 15- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS | | | SUBMITTED AS REQUIRED BYSEC. 106.3.3CITY AMENDMENTS | | | TO FBC 2004. | | | | | | 16- TRUSS DRAWINGS: | | | A) TRUSS LOADING CONDITIONS SHOWN ON TRUSS LAYOUT | | | SHEET DON'T MATCH LOADING ON INDIVIDUAL TRUSSES. REVISE | | | AS REQUIRED. | | | | | | B) ENGINEER TO USE SEAL THAT SAYS LICENSE NOT | | | CERTIFICATE. | | | | | | C) WIND LOAD CRITERIA DOESN'T MATCH SPECIFICATIONS | | | SHOWN ON DRAWING #6 OF CONSTRUCTION DOCUMENTS.REVISE | | | AS REQUIRED. | | | | | | D) ALL GENERAL DRAWINGS, DETAILS, SPECS, LETTERS | | | ETC. NEED TO HAVE ENGINEER'S ORIGINAL SEAL,SIGNATURE | | | AND DATE AS REQUIRED BY CHAPTER 471 FLORIDA STATUTES. | | | * IN ADDITION ALL SHEETS NEED TO HAVE THE ENGINEER'S | | | COMPLETE INFORMATION AS REQUIRED BY FLORIDA | | | ADMINISTRATIVE CODE SEC. 61G15-23.002. | | | ** ALSO, USE SEAL THAT SAYS LICENSE, NOT CERTIFICATE. | | | | | | 17- FOOTING NOTE ON FOOTING SCHEDULE SHEET #6 STATES | | | SAFE SOIL BEARING CAPACITY OF 2500 PSF PER SOIL TEST | | | REPORT BY EASTCOAST TESTING & ENGINEERING WAS | | | CONSIDERED FOR THE ADDITION DESIGN.SOIL TEST REPORT | | | FIRST PAGE STATES SOIL BEARING CAPACITY OF 2000 PSF. | | | CLARIFY/REVISE AS REQUIRED. | | | | | | 18- HURRICANE STRAP SCHEDULE. SEE CURRENT CATALOG FOR | | | SPECIFIC NUMBER OF FASTENERS TO BE USED AND REVISE AS | | | REQUIRED. OTHERWISE, PROVIDE COMPLETE ENGINEERING | | | ANALYSIS IF NUMBER AND TYPE OF FASTENERS DIFFER FROM | | | THOSE TESTED AND PUBLISHED BY THE MANUFACTURER. SEC. | | | 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | 19- SHEET #10: | | | A) STRUCTURAL BUCK DETAILS. SEE SEC. R613.6.2 OF | | | 2004 FLORIDA RESIDENTIAL CODE FOR PROPER WAY OF | | | INSTALLING DOORS AND WINDOW BUCKS AND REVISE DETAIL AS | | | REQUIRED. BEVELED BUCKS ARE NOT ALLOWED AND WINDOW NEED | | | COMPLETE FRAME SUPPORT. | | | | | | B) PROVIDE ONLY DETAILS,SPECSAND NOTES THAT | | | APPLY TO THIS PROJECT TO EXPEDITE REVIEW PROCESS AND | | | AVOID CODE CONFLICTS. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-04-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-04-08 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-04-08 |
Time |
07:50 |
Sent To |
M |
|
| Notes |
| 2008-04-08 08:11:57 | | | | | | | | | | NEW PLANS, REDLINED 440.14, 110.26 COMPRESSER, 313.1.1 | | | AND 210.11 (C)(3) SMOKE ALARM NOTE, AND 250.122 | | | DISCONNEC TO PANEL ON THE RISER./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-12-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-12-18 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-12-18 |
Time |
11:24 |
Sent To |
M |
|
| Notes |
| 2007-12-18 11:25:34 | | | | | | | | | | PASSED ON 9/11/07 SAME STAMPED SHEETS RESUBMITTED./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-09-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-11 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-09-11 |
Time |
11:41 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2007-03-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-03-02 |
Time |
15:51 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-03-02 |
Time |
15:02 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-11-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-13 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-13 |
Time |
08:46 |
Sent To |
P |
|
| Notes |
| 2008-11-13 08:47:01 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-09-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-12 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-12 |
Time |
08:39 |
Sent To |
B |
|
| Notes |
| 2008-09-12 08:39:53 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-04-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-01 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-01 |
Time |
11:42 |
Sent To |
E |
|
| Notes |
| 2008-04-01 11:42:58 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-12-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-10 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-10 |
Time |
10:56 |
Sent To |
Z |
|
| Notes |
| 2007-12-10 10:56:56 | TO "Z" BOX/RESUB--NEW SHEETS SUBMITTED FOR "ELECT" AND | | | "PLUMB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-09-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-07 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-07 |
Time |
08:37 |
Sent To |
Z |
|
| Notes |
| 2007-09-07 08:38:36 | TO "Z" BOX/RESUB--NEW ELEC. SHEETS SUBMITTED |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-02-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-22 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-22 |
Time |
14:25 |
Sent To |
E |
|
| Notes |
| 2007-02-22 14:26:13 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-03-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-03-27 |
Time |
17:59 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-02-12 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2007-02-12 08:31:17 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2008-05-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-05-15 |
Time |
11:51 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-05-15 |
Time |
11:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2008-04-08 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-04-08 |
Time |
10:21 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-04-08 |
Time |
10:21 |
Sent To |
B |
|
| Notes |
| 2008-04-08 10:50:42 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) ENERGY CALCULATIONS LINE 12A SHOWS A 17 SEER A/C | | | SYSTEM, PLEASE PROVIDE EQUIPMENT MODEL NUMBERS TO | | | VERIFY, PER 2004 FBC 13-607.1.ABC.3.1.1. | | | | | | 2) ENERGY CALCULATIONS LINE 12B SHOWS A 16.5 SEER A/C | | | SYSTEM, MECHANICAL PLANS SHOW THE SYSTEM TO BE 14.5 | | | SEER, THE TWO MUST COINCIDE, PLEASE CORRECT. | | | | | | 3) ENERGY CALCULATION LINE 13A AND B SHOW THE A/C | | | SYSTEMS TO BE HEAT PUMP UNITS, PLEASE PROVIDE CORRECT | | | MODEL NUMBERS FOR BOTH SYSTEMS TO VERIFY, PER 2004 FBC | | | 13-101.4.2.1. | | | | | | 4) ENERGY CALCULATIONS LINE 14A SHOWS THE WATER HEATER | | | IS NATURAL GAS, ELECTRICAL PLAN PAGE 7 STATES THE WATER | | | HEATER IS ELECTRIC, THE TWO MUST COINCIDE, PLEASE | | | CORRECT. | | | | | | 5) COOLING LOAD CALCULATIONS FOR A/C SYSTEM #2 ARE | | | CALLING FOR 34,119 TOTAL COOLING BTU'S, THE MECHANICAL | | | PLANS SHOWING THE SYSTEM TO BE 42,500 TOTAL COOLING | | | BTU'S. THE PLANS CAN ONLY CALL FOR 15% MORE THAN THE | | | COOLING LOAD CAL'S, A 3.5 TON A/C SYSTEM IS TO LARGE | | | PLEASE CORRECT, PER 2004 FBC 13-607.1.ABC.1.1. | | | | | | 6)THE A/C SYSTEM LISTED ON THE MECHANICAL PLAN A/C | | | EQUIPMENT SCHEDULE COULD NOT BE FOUND ON THE ARI | | | DIRECTORY WEB-SITE, PLEASE CORRECT OR SUBMIT AN ARI | | | CERTIFICATE, SEE 2004 FBC 13-607.1.ABC.3.1.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-12-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-12-18 |
Time |
15:12 |
Rev Time |
1.15 |
| Received By |
tgordon |
Date |
2007-12-18 |
Time |
15:12 |
Sent To |
P |
|
| Notes |
| 2007-12-18 15:36:43 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) THE NEW ENERGY CALCULATIONS SUBMITTED ARE THE WRONG | | | FORM, NEED TO SUBMIT THE 2004R FORM, PER 2004 FBC | | | 13-600.3.A. (THE SHORT FORM 600C-04R MAY BE SUBMITTED | | | FOR THE ADDITION INSTEAD OF THE LONG FORM, SEE | | | 13-600.3C.) | | | | | | 2) ENERGY CALCULATIONS NEED TO BE SIGNED BY PREPARER | | | AND OWNER/AGENT, PER 2004 FBC 13-600.3.ABC.2. | | | | | | 3) THE COOLING LOAD CALCULATIONS SUBMITTED HAVE NOT | | | BEEN CALCULATED CORRECTLY, THE WHOLE HOUSE CALCULATIONS | | | ARE CALLING FOR 234,478 TOTAL BTU'S THAT WOULD BE 19.5 | | | TONS OF AIR CONDITIONING FOR 1,238 SQUARE FEET OF | | | LIVING SPACE. SUBMIT CORRECTED COOLING LOAD | | | CALCULATIONS, PLEASE HAVE SHEETS IN CORRECT ORDER AND | | | STAPLED, SEE 2004 FBC 13-607.1.ABC.1. ONLY NEED COOLING | | | LOAD CALCULATIONS FOR THE ADDITION IF NO MECHANICAL | | | WORK IS TO BE DONE TO THE EXISTING PART OF THE HOUSE | | | AND THE A/C SYSTEM AND DUCT WORK IS TO REMAIN AS THE | | | PLANS SHOW. | | | | | | 4) PLEASE SHOW MECHANICAL PLAN PAGE 8, HOW THE AIR FROM | | | THE RETURN AIR JUMPER BOX WILL RETURN TO THE AIR | | | HANDLER IF THE DOOR IS CLOSED TO THE MEDIA ROOM, SEE | | | 2004 FBC/R M1602.4. | | | | | | 5) PLEASE SHOW THE CORRECT MODEL NUMBER FOR THE A/C | | | CONDENSER UNIT IN THE A/C SCHEDULE ON THE MECHANICAL | | | PLAN, SEE 2004 FBC 13-607.1.ABC.3.1.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-09-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-09-26 |
Time |
14:26 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-09-26 |
Time |
14:26 |
Sent To |
B |
|
| Notes |
| 2007-09-26 14:29:18 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) PLANS SUBMITTED PAGE 8 (MECHANICAL PLAN) NOW SHOWS A | | | NEW A/C SYSTEM FOR THE OFFICE. COOLING LOAD | | | CALCULATIONS (MANUAL J) IS FOR THE WHOLE HOUSE BUT | | | NEEDS TO BE FOR THE OFFICE ONLY. PLEASE SUBMIT COOLING | | | LOAD CALCULATIONS (MANUAL J) FOR THE OFFICE ONLY. SEE | | | 2004 FBC 13-607.1.ABC.1. | | | | | | 2) ENERGY CALCULATIONS LINE 6 SHOWS CONDITIONED FLOOR | | | AREA AS 1243 SQUARE FEET, IF THE ENERGY CALCULATIONS | | | ARE FOR THE WHOLE HOUSE THEN THEY NEED TO SHOW THE TWO | | | A/C SYSTEMS EXISTING AND NEW AND ALL INFORMATION NEEDS | | | TO BE ADJUSTED SHOWING ALL THE EXISTING AND NEW | | | CONDITIONS OF THE HOUSE. PLEASE REVISE ENERGY | | | CALCULATIONS, SEE FBC 13-101.2.2. | | | | | | ** IF YOU WISH YOU MAY SUBMIT ENERGY CALCULATIONS FORM | | | 600C-04R FOR THE ADDITION ONLY, SEE FBC 13-600.3.C. | | | | | | 3) PLANS PAGE 8 A/C UNIT SCHEDULE NEEDS TO SHOW THE | | | CONDENSER UNIT MODEL NUMBER ALSO, SEE W.P.B. AMEND. | | | 106.3.5.4 (10). | | | | | | 4) PLANS PAGE 8 AHU DETAIL SHOWS THE AUXILIARY DRAIN | | | LINE GOING BELOW THE SLAB. SEE 2004 FBC/R M1411.3.1 #1 | | | THE AUXILIARY DRAIN MUST DISCHARGE TO A CONSPICUOUS | | | POINT OF DISPOSAL, OR YOU MAY COMPLY WITH #3. PLEASE | | | CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-03-05 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-05 |
Time |
11:26 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-03-05 |
Time |
11:26 |
Sent To |
P |
|
| Notes |
| 2007-03-05 11:35:15 | *** DENIED *** | | | 1) NEED TO SHOW THE SIZE OF THE SUPPLY AIR DUCT FROM | | | THE EXISTING A/C TO THE MIXING BOX. | | | | | | 2) THE 10" RETURN AIR TRANSFER DUCT FOR THE OFFICE NEED | | | TO BE 14", SEE 2004 FBC/R M1602.4. | | | | | | *** 2004 FBC/R M1602.4. | | | BALANCED RETURN AIR MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2008-12-16 |
|
|
Cont ID |
OWNER |
| Sent By |
lwagner |
Date |
2008-12-16 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2008-12-16 |
Time |
14:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2008-12-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-12-10 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-12-10 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2008-12-10 11:18:31 | DENIED | | | REFERENCE: | | | FBC-2004 CHAPTER 1 | | | | | | 1. REVISIONS TO A SIGNED, SEALED, DATED PLAN SHALL BE | | | SIGNED, SEALED & DATED BY THE ARCHITECT OF RECORD. | | | PLANS SHALL HAVE ALL TITLE BLOCKS FOR THE ARCHITECT OF | | | RECORD AS REQUIRED BY THE FLORIDA ADMINISTRATIVE CODE | | | AND THE FLORIDA STATUTES. SECTION 106.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-12-20 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-12-20 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-12-20 |
Time |
10:43 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-09-25 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-09-25 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-09-25 |
Time |
15:15 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-03-08 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-03-08 |
Time |
10:59 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-03-08 |
Time |
10:59 |
Sent To |
B |
|
| Notes |
| 2007-03-08 11:25:10 | DENIED | | | REFERENCE: FBC-2004 PLUMBING; FBC-2004 CHAPTER 1, CITY | | | OF WEST PALM BEACH AMENDMENTS; | | | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING | | | PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. SHEET 4 PLUMBING PLAN INDICATES ASTUB OUT FOR | | | FUTURE SINK:PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4 | | | RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A | | | PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING | | | FUTURE SINK WASTE, VENT, TRAP AND SIZES WITH CLEANOUT | | | LOCATIONS. | | | | | | 2. PER FBC-2004 PLUMBING, SECTION 704.4 FUTURE | | | FIXTURES: DRAINAGE PIPING FOR FUTURE FIXTURES SHALL | | | TERMINATE WITH AN APPROVED CAP OR PLUG. PLEASE INDICATE | | | THIS ON THE RESUBMITTAL. | | | | | | 3. PER FBC-2004 PLUMBING, SECTION 905.6 VENT FOR FUTURE | | | FIXTURE: WHERE THE DRAINAGE PIPING HAS BEEN ROUGHED-IN | | | FOR THE FUTURE FIXTURE, A ROUGH-IN CONNECTION FOR A | | | VENT SHALL BE INSTALLED. THE VENT SIZE SHALL NOT BE | | | LESS THAN ONE-HALF THE DIAMETER OF THE ROUGH-IN DRAIN | | | TO BE SERVED. THE VENT ROUGH-IN SHALL CONNECT TO THE | | | VENT SYSTEM, OR SHALL BE VENTED BY OTHER MEANS AS | | | PROVIDED FOR IN THIS CHAPTER. THE CONNECTION SHALL BE | | | IDENTIFIED TO INTICATE THAT IT IS A VENT. PLEASE COMPLY | | | ON THE RESUBMITTAL. | | | | | | IMPORTANT INFORMATION | | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | | TRANSMITTAL LETTER INDICATING HOW EACH | | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-12-11 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-12-11 |
Time |
21:02 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-12-11 |
Time |
21:02 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-09-09 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-09-09 |
Time |
19:56 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-09-09 |
Time |
19:56 |
Sent To |
E |
|
| Notes |
| 2007-09-09 19:57:02 | ***FAILED*** | | | | | | 1) MAXIMUM BUILDING HEIGHT SHALL NOT EXCEED 30 FEET. | | | BUILDING HEIGHT IS MEASURED FROM GRADE TO THE MEAN | | | POINT OF THE PITCHED ROOF...NOT TO THE PEAK. | | | | | | 2) DISTANCE FROM A/C UNIT TO PROPERTY LINE SHALL BE | | | PROVIDED.SHALL BE A MINIMUM OF 1 FOOT. | | | | | | IMPORTANT....PLEASE REVIEW SECTION 94-273 OF THE CITY'S | | | ZONING AND LAND DEVELOPMENT REGULATIONS IF CONSIDERING | | | A HOME OCCUPATION.A COPY OF SUCH IS ATTACHED FOR YOUR | | | REVIEW. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT JOHN ROACH, SENIOR | | | PLANNER, AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-02-22 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-02-22 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-02-22 |
Time |
09:29 |
Sent To |
I |
|
| Notes |
| 2007-02-22 09:48:03 | ***FAILED*** | | | | | | 1) MAXIMUM BUILDING HEIGHT SHALL NOT EXCEED 30 FEET. | | | BUILDING HEIGHT IS MEASURED FROM GRADE TO THE MEAN | | | POINT OF THE PITCHED ROOF...NOT TO THE PEAK. | | | | | | IMPORTANT....PLEASE REVIEW SECTION 94-273 OF THE CITY'S | | | ZONING AND LAND DEVELOPMENT REGULATIONS IF CONSIDERING | | | A HOME OCCUPATION.A COPY OF SUCH IS ATTACHED FOR YOUR | | | REVIEW. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT JOHN ROACH, SENIOR | | | PLANNER, AT (561) 822-1435. |
|
|