| Plan Review Stops For Permit 07020113 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-07-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-07-11 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-07-11 |
Time |
07:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-06-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-06-29 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-06-29 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2007-06-29 14:15:06 | DENIED BY BUILDING | | | | | | 1) THE CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT | | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | | BY THE BUILDING OFFICIAL. FBC* 106.1.1 THE PLANS | | | SUBMITTED DO NOT INDICATE THE SCOPE OF THE WORK THAT IS | | | BEING TO BE DONE. | | | | | | 2) THE PRINTED NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN IS REQUIRED ON EACH SHEET OF | | | THE PLAN. SEE FBC* 106.1.2. | | | | | | NOTE: THESE SAME COMMENTS WERE MADE ON THE LAST | | | REVIEW. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-04-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-04-26 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-04-26 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2007-04-26 16:12:26 | DENIED BY BUILDING | | | | | | 1) THE CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT | | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | | BY THE BUILDING OFFICIAL. FBC* 106.1.1 THE PLANS | | | SUBMITTED DO NOT INDICATE THE SCOPE OF THE WORK THAT IS | | | BEING TO BE DONE. | | | | | | 2) THE PRINTED NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN IS REQUIRED ON EACH SHEET OF | | | THE PLAN. SEE FBC* 106.1.2. | | | | | | 3) THE ENERGY CALCULATIONS ARE REQUIRED TO BE ON FORM | | | 600C-04R FOR SOUTH ZONE 8 PER 2004 FBC CHAPTER 13. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-03-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-03-22 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-03-22 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2007-03-22 12:03:37 | DENIED BY BUILDING | | | | | | 1)THE PLANS SUBMITTED ARE FROM A FLORIDA LICENSED | | | ENGINEER AND CAN NOT BE USED WITHOUT HIS CONSENT. THE | | | PLANS ARE REQUIRED TO BE SIGNED AND SEALED. | | | | | | 2) SPECIFY THE TYPE AND R-VALUES OF THE INSULATION AND | | | LOCATIONS EACH TYPE WILL BE INSTALLED. | | | | | | 3) PLANS ARE REQUIRED TO COMPLY WITH 106.1.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS. CONSTRUCTION | | | DOCUMENTS SHALL BE DIMENSIONED AND DRAWN UPON SUITABLE | | | MATERIAL. ELECTRONIC MEDIA DOCUMENTS ARE PERMITTED TO | | | BE SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
N |
Date |
2007-06-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-06-19 |
Time |
06:55 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-06-19 |
Time |
06:54 |
Sent To |
M |
|
| Notes |
| 2007-06-19 06:57:57 | | | | | | | | | | NO ELECTRICAL WORK TO BE DONE ON THIS PERMIT PER NOTE | | | ON PLAN. ALL ELECTRICAL WORK SHOWN ON PLAN IS | | | EXISTING./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-04-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-04-20 |
Time |
07:22 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-04-20 |
Time |
07:12 |
Sent To |
M |
|
| Notes |
| 2007-04-20 07:22:09 | | | | | | | DENIED | | | | | | AN ELECTRICAL CONTRACTOR MUST APPLY FOR A PERMIT TO | | | RESTRAP ALL LOOSE WIRING, AND CALL FOR A ROUGH | | | INSPECTION AFTER ALL FRAMING IS READY FOR DRYWALL. | | | | | | THE CONTRACTOR IS NOT REQUIRED TO SUBMIT PLANS, BUT | | | MUST REFERENCE THIS PERMIT NUMBER OR MAY SIGN ON THIS | | | APPLICATION.THIS PERMIT WILL NOT BE ISSUED UNTILL AN | | | ELECTRICAL CONTRACTOR HAS APPLIED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-02-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-02-07 |
Time |
14:13 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-02-07 |
Time |
13:00 |
Sent To |
M |
|
| Notes |
| 2007-02-06 17:02:22 | | | | | | | | | | NONCOMPLIANT | | | | | | THE PLANS SUBMITTED INDICATE THE COMPLETE WIRING OF | | | THIS RESIDENCE, IF THAT IS NOT THE INTENT, ONLY SUBMIT | | | PLANS FOR THE ACTUAL DESCRIPTION OF WORK TO BE DONE. | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1}INDICATE THE SERVICE EQUIPMENT LOCATION. THE PLAN | | | SHOWS THE SERVICE IN TWO LOCATIONS. | | | | | | 2} PUT THE ADDRESS OF THE RESIDENCE OR A LEGAL | | | DISCRIPTION BY WHICH IT CAN BE IDENTIFIED, ON THE | | | PLAN. | | | | | | 3} THE ARCHITECTURAL FIRM WHOSE TITLE BLOCK APPEARS ON | | | THE PLANS, MUST SIGN AND SEAL THE PLAN PER | | | 481.221(1)(B)FS. | | | | | | WILLIAM R. TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-07-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-09 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-09 |
Time |
13:39 |
Sent To |
B |
|
| Notes |
| 2007-07-09 13:39:54 | TO "RMCDOUGAL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-06-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-15 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-15 |
Time |
11:02 |
Sent To |
E |
|
| Notes |
| 2007-06-15 11:02:47 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-04-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-18 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-18 |
Time |
16:26 |
Sent To |
E |
|
| Notes |
| 2007-04-18 16:26:56 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-03-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-03-22 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-02-06 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2007-02-06 14:54:50 | TO "E" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-06-19 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-06-19 |
Time |
08:57 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-06-19 |
Time |
08:57 |
Sent To |
B |
|
| Notes |
| 2007-06-19 09:12:01 | *** PROVISO *** | | | 1) CLOTHES DRYER VENT TERMINATION MAY NOT DISCHARGE | | | NEAR THE A/C CONDENSER UNIT, SEE 2004 FBC/M 501.2 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-04-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-04-20 |
Time |
09:20 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2007-04-20 |
Time |
09:20 |
Sent To |
B |
|
| Notes |
| 2007-04-20 09:35:26 | *** DENIED *** | | | 1) ENERGY CALCULATIONS NEED TO BE ON FORM 600C-04R | | | "SOUTH ZONE 7 8 9", PER 2004 FBC 13-600.3.C (12-8-06 | | | REVISION). | | | | | | 2) CLOTHES DRYER VENT TERMINATION MAY NOT DISCHARGE | | | NEAR THE A/C CONDENSER UNIT, SEE 2004 FBC/M 501.2 . | | | PLEASE CORRECT. | | | | | | 3) AS REQUESTED IN LAST REVIEW 2-13-07 NOTE 3, THE 8" | | | RETURN AIR TRANSFER DUCT TO BEDROOM #3 NEEDS TO BE 9", | | | SEE YELLOW HIGH LIGHTS ON MECHANICAL PLANS PAGE 5. SEE | | | 2004 FBC/R M1602.4 (A). PLEASE CORRECT. | | | | | | 4) AS REQUESTED IN LAST REVIEW 2-13-07 NOTE 4, THE 10" | | | RETURN AIR TRANSFER DUCT TO THE MASTER SUITE NEEDS TO | | | BE 14", SEE YELLOW HIGH LIGHTS ON MECHANICAL PLANS PAGE | | | 5. SEE 2004 FBC/R M1602.4 (A) AND (C) EXCEPT. PLEASE | | | CORRECT. | | | | | | 5)ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE PRINTED NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN. PER | | | FBC 104.2.1 . | | | | | | *** 2004 FBC/R M1602.4 BALANCED RETURN AIR MAY BE | | | ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY INCREASING THE | | | RETURN TRANSFER ONE AND ONE HALF TIMES THE CROSS | | | SECTIONAL AREA (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING AND THE DOOR | | | HAVING AT LEAST AN UNRESTRICTED 1 INCHUNDERCUT TO | | | ACHIEVE PROPER RETURN AIR BALANCE. | | | (C)HABITABLE ROOMS ONLY SHALL BE REQUIRED TO MEET | | | THESE REQUIREMENTS FOR PROPER BALANCED RETURN AIR | | | EXCLUDING BATHROOMS, CLOSETS, STORAGE ROOMS AND LAUNDRY | | | ROOMS, EXCEPT THAT ALL SUPPLY AIR INTO THE MASTER SUITE | | | SHALL BE INCLUDED. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-02-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-13 |
Time |
08:00 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-02-13 |
Time |
08:00 |
Sent To |
P |
|
| Notes |
| 2007-02-13 08:13:57 | *** DENIED *** | | | 1) THE PLANS NEED TO BE SIGNED AND SEALED BY THE | | | ARCHITECT AS THEIR NAME APPEARS IN THE TITLE BLOCK, PER | | | FAC 61G1-16.003. | | | | | | 2) THE PLANS NEED THE JOB ADDRESS IN THE TITLE BLOCK, | | | PER FAC 61G1-16.004. | | | | | | 3) THE 8" RETURN AIR TRANSFER DUCT TO BEDROOM #3 NEEDS | | | TO BE 9", SEE 2004 FBC/R M1602.4 (A). | | | | | | 4) THE 10" RETURN AIR TRANSFER DUCT TO THE MASTER SUITE | | | NEEDS TO BE 14", SEE 2004 FBC/R M1602.4 (A) AND (C) | | | EXCEPT. | | | | | | *** 2004 FBC/R M1602.4 BALANCED RETURN AIR MAY BE | | | ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY INCREASING THE | | | RETURN TRANSFER ONE AND ONE HALF TIMES THE CROSS | | | SECTIONAL AREA (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING AND THE DOOR | | | HAVING AT LEAST AN UNRESTRICTED 1 INCHUNDERCUT TO | | | ACHIEVE PROPER RETURN AIR BALANCE. | | | (C)HABITABLE ROOMS ONLY SHALL BE REQUIRED TO MEET | | | THESE REQUIREMENTS FOR PROPER BALANCED RETURN AIR | | | EXCLUDING BATHROOMS, CLOSETS, STORAGE ROOMS AND LAUNDRY | | | ROOMS, EXCEPT THAT ALL SUPPLY AIR INTO THE MASTER SUITE | | | SHALL BE INCLUDED. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2007-02-20 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-02-20 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-02-20 |
Time |
07:59 |
Sent To |
B |
|
| Notes |
| 2007-02-20 08:02:07 | NO PLUMBING WORK SHOWN IF CABINET ARE TO BE REPLACES | | | PLEASE LIST PLUMBING FIXTURES TO BE INSTALLED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|