Plan Review Details - Permit 07020105
Plan Review Stops For Permit 07020105
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-04-03 Cont ID  
Sent By shill Date 2007-04-03 Time 09:22 Rev Time 0.00
Received By shill Date 2007-04-03 Time 09:22 Sent To  
Notes
2007-04-03 09:26:48PROVISO -
  
 NO FIRE RATED WALLS AFFECTED
  
 SEPARATE PERMIT FOR WINDOWS

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-03-14 Cont ID  
Sent By shill Date 2007-03-14 Time 10:47 Rev Time 0.00
Received By shill Date 2007-03-14 Time 10:47 Sent To E
Notes
2007-03-14 11:31:21****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 1.)THE PLAN STATES THAT THE DAMAGE IS 6' NORTH FROM
 COMMON LINE OF BUILDINGS, ENGINEER'S NOTES 2, SHEET 1.
 WERE FIRE RATED WALLS AFFECTED?FROM THE WRITTEN
 DESCRIPTION IT DOES NOT APPEAR TO BE AT THE WALL
 SEPARATING THE BUILDINGS, BUT THE ELEVATION ON SHEET 1
 SHOWS THE DAMAGE AT A CORNER/WALL.THE EXISTING FLOOR
 PLAN SHOWS THIS CORNER AS A TENANT SEPARATION.IF A
 FIRE RATED WALL WAS AFFECTED, PROVIDE A DETAIL FOR
 REPAIR SHOWING FIRE RATING REQUIREMENT (TENANT OR
 OCCUPANCY SEPARATION OR OTHER FIRE RATING REQUIRED BY
 FBC CHAPTER 5 OR FBC CHAPTER 6) AND COMPLIANCE WITH
 EITHER A TESTED ASSEMBLY OR CALCULATED FIRE RESISTANCE,
 FBC CHAPTER 9.
  
 2.)NEW SHEETS WERE SUBMITTED.IT IS NOT CLEAR WHY AN
 EXISTING BUILDING PLANS WERE SUBMITTED, ESPECIALLY AS
 ONE OF THE SHEETS IS ILLEGIBLE.PLEASE SHOW LOCATION
 OF THE REPAIR ON THESE SHEETS, ALTHOUGH IT IS NOT CLEAR
 WHY ELECTRIC SHEETS ARE SUBMITTED.
  
 3.)THE PROJECT DESCRIPTON STATES THAT THE WINDOWS
 WILL BE REPLACED.NO PRODUCT APPROVALS SUBMITTED.ANY
 PRODUCT APPROVALS NOT REVIEWED PRIOR TO PERMIT ISSUANCE
 WILL REQUIRE SEPARATE PERMITS.PRODUCT APPROVALS ARE
 TO BE REVIEWED BY DESIGNER OF RECORD PRIOR TO
 SUBMITTAL,FBC*106.3.3.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-02-27 Cont ID  
Sent By shill Date 2007-02-27 Time 14:56 Rev Time 0.00
Received By shill Date 2007-02-27 Time 14:56 Sent To  
Notes
2007-02-27 14:57:12****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC RFLORIDA BUILDING CODE 2004
 RESIDENTIAL
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 1.)ALL INFORMATION REQUIRED BY FAC61G15-23.002 FOR
 THE ENGINEER AND ENGINEERING FIRM ARE TO BE ON EACH
 SHEET.

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2007-04-03 Cont ID  
Sent By btrobaug Date 2007-04-03 Time 09:02 Rev Time 0.00
Received By btrobaug Date 2007-04-03 Time 08:59 Sent To B
Notes
2007-04-03 09:02:04 
  
 THERE IS NO ELECTRICAL WORK TO BRE DONE OR NONE APPLIED
 FOR WITH THIS PERMIT APPLICATION. OLD BUILDING PLANS
 WERE SUBMITTED FOR REFERENCE.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-03-16 Cont ID  
Sent By btrobaug Date 2007-03-16 Time 14:46 Rev Time 0.50
Received By btrobaug Date 2007-03-16 Time 14:39 Sent To PC
Notes
2007-03-16 14:46:53 
  
 THERE ARE ELECTRICAL PLANS SUBMITTED WITH THE
 APPLICATION, BUT NO ELECTRICAL CONTRACTOR SIGNED ON.
 PLEASE INDICATE IF ELECTRICAL WORK IS TO BE DONE. SEE
 CHAPTER 13FBC FOR ENERGY REQUIRENENTS
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]
 .

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-03-13 Cont ID  
Sent By adarroug Date 2007-03-13 Time 09:43 Rev Time 0.00
Received By adarroug Date 2007-03-13 Time 09:43 Sent To B
Notes
2007-03-13 09:43:58TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-02-27 Cont ID  
Sent By shill Date 2007-02-27 Time 14:57 Rev Time 0.00
Received By shill Date 2007-02-05 Time 11:44 Sent To  
Notes
2007-02-05 11:45:57TO "MISC" BOX#1