Plan Review Details - Permit 07020100
Plan Review Stops For Permit 07020100
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-06-05 Cont ID  
Sent By jgomez Date 2007-06-05 Time 16:45 Rev Time 0.00
Received By jgomez Date 2007-06-05 Time 16:45 Sent To PC
Notes
2007-06-05 16:47:39BUILDING REVIEW SECOND CHECKLIST:
 1- ONLY ONE SET OF PLANS WAS SUBMITTED AND IT WAS NOT
 SIGNED AND SEALED BY THE ARCHITECT OF RECORD.NEED TWO
 COMPLETE SETS OF DRAWINGS WITH ORIGINAL SEAL AND
 SIGNATURE AS REQUIRED BY CHAPTER 481 FLORIDA STATUTES.
  
 2-NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY
 SEC. 713.13 FLORIDA STATUTE.
  
 3- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY
 DCA RULE 9B-72 FOR:
 A) HARDIE BOARD SIDING.
  
 B) SINGLE HUNG WINDOWS WITH DESIGN PRESSURES RATING
 OF -90PSF AND +58.7 AS SPECIFIED ON WINDOW SCHEDULE.
  
 C) ALL STRUCTURAL SIMPSON CONNECTORS SPECIFIED ON
 PLANS,DETAILS AND ARCHITECT'S CHECKLIST RESPONSE
 LETTER.
  
 D) STORM SHUTTERS. AND, INDICATE SPECIFIC ANCHOR
 TYPE AND SPACING TO BE USED. SEESTORM SHUTTERS
 ENGINEERED DRAWINGS AND CIRCLE SPECIFIC ANCHOR.
  
 E) FLAT ROOF ASSEMBLY. CLEARLY IDENTIFY SPECIFIC
 APPROVED ASSEMBLY AND PROVIDE NAIL ENHANCING FOR
 PERIMETER AND CORNER AREAS. SEE GENERAL LIMITATION #7
 ON PRODUCT APPROVAL AND PROVIDE REQUIRED INFORMATION.
  
 4- ARCHITECT TO REVIEW AND APPROVE IN WRITING (NOT
 SIGNING AND SEALING) ALL PRODUCT APPROVALS AS REQUIRED
 BY SEC. 106.3.3 OF CITY AMENDMENTS TO FBC 2004.
  
 5- REVISE ROOF SHEATHING NAILING SPECIFICATIONS. NEED
 TO USE MIN. 8D RING SHANK NAILS AS REQUIRED BY SEC.
 R803.2.3.1 OF 2004 FLORIDA RESIDENTIAL CODE.
  
 6- OWES $101 FOR UPDATED VALUATION AS REQUIRED BY SEC.
 108.3 OF CITY AMENDMENTS TO FBC 2004.
  
 7- ARCHITECT TO PROVIDE ORIGINAL SIGNATURE AND SEAL TO
 CHECKLIST RESPONSE LETTER AND TO SIGN AND SEAL
 CALCULATIONS SUBMITTED AS REQUIRED BY CHAPTER 481
 FLORIDA STATUTE. PROVIDE 2 COPIES.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-03-26 Cont ID  
Sent By jgomez Date 2007-03-26 Time 13:50 Rev Time 0.00
Received By jgomez Date 2007-03-26 Time 12:39 Sent To PC
Notes
2007-03-26 14:53:14BUILDING REVIEW CHECKLIST:
 1- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY
 SEC. 713.13 FLORIDA STATUTE.
  
 2- GENERAL NOTES REFERENCE ASCE 7-98.NEED TO UPDATE
 TO ASCE 7-02 AS REFERENCED IN FBC 2004.
  
 3- TITLE BLOCK TO HAVE THE FIRM LICENSE NUMBER AS
 REQUIRED BY SEC. 61G1-16.004 FLORIDA ADMINISTRATIVE
 CODE.
  
 4- NAME OF ARCHITECT DOESN'T MATCH NAME SHOWN ON
 IMPRESSED SEAL. REVISE AS REQUIRED TO MATCH.
  
 5- SITE PLAN DOESN'T SHOW THE PROPOSED COVERED PORCH.
  
 6- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) HARDIE BOARD SIDING.
 B) SINGLE HUNG WINDOW WITH DESIGN PRESSURE RATING OF
 -90.0 AND +58.7 AS SPECIFIED ON WINDOW SCHEDULE.
 C) STRUCTURAL CONNECTORS SPECIFIED ON PLANS AND
 DETAILS.
 D) STORM SHUTTERS. AND, INDICATE ANCHOR TYPE AND
 SPACING.
 E) FLAT ROOF ASSEMBLY.
 *** NOTE: PRODUCT APPROVALTYPICALLYHAVE SEVERAL
 DIFFERENT APPROVED ASSEMBLIES. CLEARLY IDENTIFY
 SPECIFIC ASSEMBLY TO BE INSTALLED AND SPECIFIC
 FASTENING OPTION. IN ADDITION, IF SELECTED ASSEMBLY IS
 LIMITED BY GENERAL LIMITATION #7, THEN PROVIDE THE RAS
 117 CALCULATIONS. SEE GENERAL LIMITATION #7. ASSEMBLIES
 WITH GENERAL LIMITATION #9 CAN'T BE USED IN THIS AREA.
  
 7- ARCHITECT TO REVIEW AND APPROVE IN WRITING (NOT
 SIGNING AND SEALING) ALL PRODUCT APPROVALS AS REQUIRED
 BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 8- 2"X6"WOOD JOISTS CAN'T BE USED FOR PROPOSED SPAN.
 SEE AF&PA SPAN TABLES AND REVISE AS REQUIRED. SEC.
 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 9- SPECIFY ALL LIVE AND DEAD LOADS AS REQUIRED BY SEC.
 R301 OF 2004 FLORIDA RESIDENTIAL CODE.
  
 10- SPECIFY CALCULATED UPLIFT LOADS AT WOOD COLUMNS TO
 VERIFY COMPLIANCE OF CONNECTOR SPECIFIED FOR COLUMN
 BASE. CITY AMENDMENTS TO FBC 2004.
  
 11- SPECIFY CONNECTORS AT TOP OF WOOD COLUMNS. SEC.
 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 12- PROVIDE WALL SECTION SHOWING 2"X4" CONNECTIONS, TOP
 AND BOTTOM.AND STUDS SPACING. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 13- PROVIDE DIMENSIONS ON PLANS SHOWING COLUMNS EXACT
 LOCATION. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 14- PROVIDE ROOF SHEATHING FASTENING SPECIFICATIONS.
 SEE SEC. R803.2.3.1 2004 FLORIDA RESIDENTIAL CODE FOR
 TYPE OF FASTENER.
  
 15-DESIGN PRESSURES NEED TO BE HIGHER BECAUSE THIS IS
 NOT AN ENCLOSEDSTRUCTURE.PLANS TO SPECIFICALLY
 INDICATE TYPE OF STRUCTURE DESIGN. EG: OPEN, ENCLOSED
 ETC. AND REVISE ALL DESIGN PRESSURES ON PAGE A-3.0AS
 REQUIRED. SEC.R301 OF 2004 FLORIDA RESIDENTIAL CODE.
  
 16- SPECIFY BEAM THAT SUPPORTS CEILING JOISTS. SEC.
 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 17- SPECIFY CONNECTORS FOR CEILINGJOISTS AT BOTH
 ENDS. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 18- PROVIDE SECTION/DETAIL SHOWING ATTACHMENT OF NEW
 CEILING TO EXISTING STRUCTURE. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 19- VALUATION OF PROJECT WAS TOO LOW. IT WAS UPDATED.
 OWES $101 FOR PERMIT VALUATION. SEC. 108.3CITY
 AMENDMENTS TO FBC 2004.
  
 20- SHEET A-2.0:ELEVATIONS DON'T MATCH INFORMATION
 GIVEN ON DETAIL 10-A-2. REVISE AS REQUIRED.
  
 21- ARCHITECT TO REVIEW SEC. 2002 OF 2004 FLORIDA
 RESIDENTIAL AND PROVIDE ALL REQUIRED INFORMATION
 REGARDING THE STRUCTURAL ALUMINUM STRUCTURES DESIGN.
  
 22- SHEET A-3.0:
 A) ARCHITECT TO REVIEW PRODUCT APPROVAL FOR
 HARDIBOARD AND SPECIFY FASTENING AT WALL AND SOFFITS.
 NOTE THAT WOOD MEMBERS SPACING MAY NEED TO BE REVISED
 TO MEET PRODUCT APPROVAL REQUIREMENTS.SEC. 106.1.2
 CITY AMENDMENTS TO FBC 2004.
  
 B) NEED TO PROVIDE CONTINUOUS VENTILATION AS
 REQUIRED BY SEC. R806 OF 2004 FLORIDA RESIDENTIAL CODE.
 REVISE AS REQUIRED.
  
 C) WHERE IS THE HURRICANE ANCHOR SCHEDULE SPECIFIED
 ON SCREEN WALL SECTION. SEC. 106.1.2 CITY AMENDMENTS TO
 FBC 2004.
  
 D) PROVIDE COMPLETE SPECS FOR BEAM TYPE "B-1" AND
 "B-2'. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 23- SHEET A-4.0: REVISE CONCRETE NOTE #5.SEE SEC.
 R403 OF 2004 FLORIDA RESIDENTIALCODE FOR MINIMUM
 CONCRETE COVER FOR REBARS.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-05-24 Cont ID  
Sent By btrobaug Date 2007-05-24 Time 10:38 Rev Time 0.33
Received By btrobaug Date 2007-05-24 Time 10:30 Sent To B
Notes
2007-05-24 10:38:42 
  
 REVISION DENIED/INCOMPLETE INFORMATION
  
 TWO SETS OF ALL DOCUMENTS MUST BE SUBMITTED FOR REVIEW
 PER 106.1 FBC AS AMENDED.
  
 THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-02-21 Cont ID  
Sent By btrobaug Date 2007-02-21 Time 07:26 Rev Time 0.50
Received By btrobaug Date 2007-02-21 Time 07:09 Sent To B
Notes
2007-02-21 07:26:05 
  
 DENIED/INCOMPLETE INFORMATION
  
 SHOW COMPLIANCE WITH 210.70.(2)(B) FOR ILLUMINATION AT
 THE EXTERIOR DOORS. NEW FIXTURES DO NOT NEED TO BE
 INSTALLED IF THERE IS ILLUMINATION EXISTING.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-05-23 Cont ID  
Sent By adarroug Date 2007-05-23 Time 11:51 Rev Time 0.00
Received By adarroug Date 2007-05-23 Time 11:51 Sent To E
Notes
2007-05-23 11:52:14TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-05-18 Cont ID  
Sent By adarroug Date 2007-05-18 Time 09:07 Rev Time 0.00
Received By adarroug Date 2007-05-18 Time 09:07 Sent To Z
Notes
2007-05-18 09:07:30TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-02-20 Cont ID  
Sent By adarroug Date 2007-02-20 Time 17:24 Rev Time 0.00
Received By adarroug Date 2007-02-20 Time 17:23 Sent To E
Notes
2007-02-20 17:24:24TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-03-26 Cont ID  
Sent By jgomez Date 2007-03-26 Time 14:53 Rev Time 0.00
Received By jgomez Date 2007-02-06 Time 13:18 Sent To  
Notes
2007-02-06 13:20:12TO "Z" BOX

Review Stop Z ZONING
Rev No 2 Status F Date 2007-05-22 Cont ID  
Sent By adavila Date 2007-05-22 Time 16:38 Rev Time 0.00
Received By adavila Date 2007-05-21 Time 20:34 Sent To I
Notes
2007-05-22 16:44:22PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1.ONLY ONE (1) COPY OF THE SURVEY AND PLANS WERE
 SUBMITTED WITH THE APPLICATION.NEED TO PROVIDE TWO
 (2) COPIES OF THE SURVEY AND PLANS.
  
 2.SETBACK DIMENSIONS SHALL BE SHOWN ON BOTH COPIES OF
 THE SURVEY.
  
 COMMENTS/QUESTIONS CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.

Review Stop Z ZONING
Rev No 1 Status F Date 2007-02-15 Cont ID  
Sent By adavila Date 2007-02-15 Time 11:55 Rev Time 0.00
Received By adavila Date 2007-02-15 Time 11:54 Sent To I
Notes
2007-02-15 13:17:26PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1. PLEASE PROVIDE RESPONSE TO COMMENTS IN WRITING.
  
 2. PROVIDE DIMENSIONS BETWEEN PROPOSED ADDITION AND
 EXISTING METAL SHED.
  
 3. PROVIDE ALL SETBACK DIMENSIONS OF THE PROPOSED
 ADDITION FROM THE PROPERTY LINE.
  
 COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.