| Plan Review Stops For Permit 07011368 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-04-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-04-20 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-04-20 |
Time |
15:12 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-03-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-03-16 |
Time |
17:41 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2007-03-16 |
Time |
17:41 |
Sent To |
|
|
| Notes |
| 2007-03-16 18:01:32 | BUILDING REVIEW CHECKLIST: | | | 1- ARCHITECTURAL PLANS CALL FOR LEVEL 3 RENOVATION. SEE | | | CHAPTER 3 OF 2004 EXISTING BUILDING CODE FOR CORRECT | | | TYPE OF ALTERATION LEVEL AND REVISE AS REQUIRED. | | | | | | 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | 13-101.2 FBC 2004. | | | ***NOTE:PLEASE MAKE SURE ALL INFORMATION IS COMPLETE, | | | INCLUDING ALL INFORMATION ON TOP OF FORM.AND, FORM IS | | | SIGNED BY THE ENERGY CALCULATIONS PREPARER AND THE | | | OWNER/AGENT. | | | | | | 3-DRAWINGS NEED TO SPECIFY ROOF INSULATION. | | | COORDINATE WITH THE ENERGY CALCULATIONS. | | | | | | 4- PROVIDE CORRECT BUILDING AREA .ACCORDING TO | | | DIMENSIONS SHOWN ON PLANS BUILDING AREA IS INCORRECT. | | | REVISE AS REQUIRED.UPDATE INFORMATION WITH PALM BEACH | | | COUNTY IMPACT FEES DEPARTMENT. | | | | | | 5- VALUATION DECLARED ON THE PERMIT APPLICATION IS TOO | | | LOW. PROVIDE UPDATEDVALUATION, INCLUDING ARCHITECT'S | | | FEES. OTHERWISEVALUATION WILL BE UPDATED AS REQUIRED | | | BY SEC. 108.3 CITY AMENDMENTS TO FBC 2004. | | | | | | 6- IF USING IMPACT DOORS, THEN CLARIFY WHY SUBMITTING | | | PRODUCT APPROVAL FOR STORM SHUTTERS.IF USING SHUTTERS | | | PROVIDE COMPLETE INSTALLATION SCHEDULE.SEE ATTACHED | | | SAMPLEOF INSTALLATION SCHEDULE. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER. | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-04-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-04-18 |
Time |
07:27 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-04-18 |
Time |
07:05 |
Sent To |
B |
|
| Notes |
| 2007-04-18 07:26:42 | | | | | | | | | | PROVISO | | | | | | THIS PERMIT IS FOR THE REAR FOYER ONLY. ALL OTHER WORK | | | HAS BEEN APPLIED FOR ON A SEPARATE APPLICATION. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-02-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-02-20 |
Time |
16:51 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2007-02-20 |
Time |
16:33 |
Sent To |
B |
|
| Notes |
| 2007-02-20 16:49:19 | | | | | | | DENIED/INCOMPLETE INFORMATION | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1} THE CIRCUIT NUMBER AT THE DEVICES ARE NOT REQUIRED | | | FOR A RESIDENTIAL PLAN. IF THEY ARE PROVIDED THEY MUST | | | CORRELATE WITH THE PANEL SCHEDULE. | | | | | | 2} PROVIDE A RISER DIAGRAM WITH CONDUCTOR AND CONDUIT | | | SIZE AND TYPE, GROUNDING DETAILS, ANDPANEL SCHEDULE | | | FOR THE NEW 100 AMP PANEL SHOWN. | | | | | | 3} RECEPTACLES MUST BE ADDED TO THE NEW ROOM PER | | | 210.52(B), SEE REVIEWED SET. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-04-05 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-04-05 |
Time |
17:41 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-04-05 |
Time |
17:41 |
Sent To |
E |
|
| Notes |
| 2007-04-05 17:41:38 | TO BILL TROBAUGH |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-02-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-20 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-20 |
Time |
11:06 |
Sent To |
E |
|
| Notes |
| 2007-02-20 11:07:06 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-03-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-03-16 |
Time |
18:01 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-02-02 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2007-02-02 14:57:54 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2007-03-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-03-16 |
Time |
18:02 |
Rev Time |
|
| Received By |
jgomez |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2007-03-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-03-16 |
Time |
18:02 |
Rev Time |
|
| Received By |
jgomez |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2007-02-16 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-02-16 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-02-16 |
Time |
15:11 |
Sent To |
B |
|
| Notes |
| 2007-02-16 15:15:44 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. |
|
|