Plan Review Details - Permit 07011238
| Plan Review Stops For Permit 07011238 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-03-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-03-09 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-03-09 |
Time |
18:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-02-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-02-21 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-02-21 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2007-02-21 14:44:19 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBEXISTING BUILDING CODE 2004 | | | FBC R RESIDENTIAL 2004 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | | | | FROM PREVIOUS LIST, NOT ADDRESSED: | | | | | | | | | _XX_ 7.PROVIDE A DESCRIPTION OF THE EXISTING DOOR | | | (AMOUNT OF GLAZING).THIS IS TO SHOW COMPLIANCE WITH | | | THE EXCEPTION TO IMPACT PROTECTION, FBC EB 507.3, FBC | | | 1609.1.4. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-02-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-02-09 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-02-09 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2007-02-09 14:07:04 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBEXISTING BUILDING CODE 2004 | | | FBC R RESIDENTIAL 2004 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | | | | ***WINDOW OR DOOR PERMIT APPLICATION, ONLY CHECKED | | | ITEMS APPLY*** | | | | | | ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH | | | THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13. | | | | | | ____2.PROVIDE BUILDING HEIGHT.DESIGN PRESSURES | | | FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE DESIGNED | | | USING ASCE7, FBC1609.1.1. DOCUMENTS PREPARED BY AN | | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED SEALED ORIGINALS FAC61G15-23.002. | | | | | | ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION | | | APPROVAL. | | | | | | ____4.IMPACT PROTECTION REQUIRED,FBC1609.1.4.IF | | | LESS THAN 25% OF THE TOTAL GLAZED AREA IS BEING | | | REPLACED, PROVIDE CALCULATIONS FBC EB507.3. | | | | | | ____5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | | | ____6.PROVIDE A FLOOR PLAN SHOWING: WINDOW | | | LOCATIONS, SIZES, WINDOW TYPE, ROOM DESIGNATIONS.NOTE | | | EXISTING CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE | | | FOR BEDROOMS, FBC R310, FBC EB 505.1. | | | | | | _XX_ 7.PROVIDE A DESCRIPTION OF THE EXISTING DOOR | | | (AMOUNT OF GLAZING). | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-03-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-07 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-07 |
Time |
10:03 |
Sent To |
B |
|
| Notes |
| 2007-03-07 10:04:04 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-02-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-20 |
Time |
18:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-20 |
Time |
18:25 |
Sent To |
B |
|
| Notes |
| 2007-02-20 18:25:30 | TO "SHILL' DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-02-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-02-09 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-01-31 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2007-01-31 14:09:14 | TO "MISC" BOX#1 |
|
|
|