| Plan Review Stops For Permit 07011206 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-01-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-01-02 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-01-02 |
Time |
14:28 |
Sent To |
PC |
|
| Notes |
| 2008-01-02 14:28:47 | BAR AREA REVISION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-11-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-11-30 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-11-30 |
Time |
07:43 |
Sent To |
PC |
|
| Notes |
| 2007-11-30 08:01:13 | WET BAR AREA REVISION.CABINETS FOR FUTURE | | | INSTALLATION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-05-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-05-30 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-05-30 |
Time |
07:38 |
Sent To |
PC |
|
| Notes |
| 2007-05-30 12:24:44 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1- NEED TO PROVIDE ELEVATION CERTIFICATE FOR NEW | | | ADDITION AND OUTSIDE EQUIPMENT. | | | | | | 2- SEE GENERATOR SPECS FOR REQUIRED CONCRETE SLAB SIZE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-04-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-04-19 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-04-19 |
Time |
09:33 |
Sent To |
PC |
|
| Notes |
| 2007-04-19 16:31:43 | BUILDING REVIEW SECOND CHECKLIST: | | | 1- NEW GENERATOR: ADDRESS COMMENTS BY ELECTRICAL AND | | | MECHANICAL PLAN REVIEWERS REGARDING LOCATION NEAR | | | OPENINGS AND EQUIPMENT CLEARANCES. | | | | | | 2- PROVIDE COMPLETE SPECS FROM BBQ AND HOOD | | | MANUFACTURER STATING THAT LOCATION OF THIS EQUIPMENT | | | NEXT TO A WINDOW IS OK. SEC. 106.1.2 CITY AMENDMENTS TO | | | FBC 2004. | | | | | | 3- BRING DRAWINGS TO PALM BEACH COUNTY TO SEE IF IMPACT | | | FEES ARE DUE OR NOT. THEY ARE THE ONES WHO DETERMINE IF | | | IMPACT FEES ARE DUE OR NOT.LETTER SUBMITTED IS ONLY | | | TO STATE THAT THERE WAS A BUILDING IN THIS LOCATION. | | | SHOWLETTER TO PALM BEACH COUNTY TO SEE WHAT CREDIT IS | | | GRANTED. BRING BACK STAMPED PLANS AND COPY OF PAID | | | RECEIPT IF FEES ARE DUE. | | | | | | 4- NOTICE OF COMMENCEMENT IS EXPIRED AFTER 90 DAYS OF | | | BEING RECORDED IF WORK IS NOT STARTED.SEC. 713.13 | | | FLORIDA STATUTE. NEED RE-RECORDED NOTICE OF | | | COMMENCEMENT. | | | | | | 5- SHEET A-2:MISSING THE COVERED PORCH AREA IN THE | | | TOTAL AREA CALCULATIONS.PROVIDE INFORMATION AS | | | REQUIRED. | | | | | | 6- SHEET A-6: NEED TO REVISE THE DESIGN PRESSURES. NEED | | | TO USE REVISED TABLE 1609.6.2.1(2) OF FBC 2004, NOT | | | TABLE 1609.6B. | | | | | | 7- SUBMITTED DRAWINGS ARE TOO DARK AND THEY WON'T BE | | | ABLE TO BE COPIED FOR CITY RETENTION FILES. PROVIDE | | | CLEAR AND LEGIBLE DRAWINGS AS REQUIRED BY SEC. 106.1.3 | | | CITY AMENDMENTS TO FBC 2004. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-03-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-03-14 |
Time |
18:56 |
Rev Time |
3.00 |
| Received By |
jgomez |
Date |
2007-03-14 |
Time |
17:33 |
Sent To |
|
|
| Notes |
| 2007-03-14 19:00:05 | BUILDING REVIEW CHECKLIST: | | | 1- PROVIDE COMPLETE INFORMATION FOR GENERATOR. | | | INCLUDING SPECS, CLEARANCES, ETC. . SEC. 106.1.2 CITY | | | AMENDMENTS TO FBC 2004. | | | | | | 2- PROVIDE COMPLETE SPECS FOR BBQ HOOD APPROVED FOR | | | EXTERIOR LOCATION.SEC. G2447 AND SEC. 106.1.2 CITY | | | AMENDMENTS TO FBC 2004. | | | ***NOTE: VERIFY WITH MANUFACTURER SPECS IF LOCATION | | | NEXT TO WINDOW IS ACCEPTABLE.PROVIDE SPECS. | | | | | | 3-BRING DRAWINGS TO PALM BEACH COUNTY. BRING BACK | | | STAMPED PLANS AND COPY OF THE PAID RECEIPT. | | | | | | 4- SHEET A-2:REVISE A/C AREA AND PORCH AREA | | | CALCULATIONS.BRING PLANS TO PALM BEACH COUNTY FOR | | | IMPACT FEES ASSESMENT AFTER AREAS ARE REVISED. | | | | | | 5- SHEET A-5:REVISE DESIGN PRESSURES FOR WIND LOADS | | | AT CORNER AREAS. SEE TABLE 1609.6.2.1(2). | | | | | | 6- SOIL TEST REPORT NEEDS THE ENGINEERING FIRM | | | CERTIFICATE OF AUTHORIZATION NUMBER ON EACH SHEET AS | | | REQUIRED BY SEC. 61G15-23.002 FLORIDA ADMINISTRATIVE | | | CODE. | | | | | | 7- SPECIFY SIZE OF CONTINUOUS ATTIC VENTILATION AS | | | REQUIRED BY SEC. R806 2004 FLORIDA RESIDENTIAL CODE. | | | | | | 8- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE | | | 9B-72 FOR: | | | A) HARDI SIDING AND HARDI SOFFIT. | | | | | | B) SLIDING GLASS DOORS. | | | | | | C) PRECAST LINTELS. | | | | | | D) TRUSS CONNECTORS SPECIFIED ON PLANS. | | | | | | E) METAL ROOFING.NOA 04-0503.03 SUBMITTED WAS | | | SUPERSED. SEE COPY OF DADE COUNTY NOA WEBSITE. PROVIDE | | | CURRENT PRODUCT APPROVAL. | | | | | | 9- DESIGNER OF RECORD TO REVIEW AND APPROVE (NOT SIGN | | | AND SEAL) IN WRITING ALL PRODUCT APPROVALS AS REQUIRED | | | BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | | | | 10- DESIGNER OF RECORD TO SEE PRODUCT APPROVAL FOR | | | HARDISOFFIT AND SPECIFYHOW THE STRUCTURE WILL BE | | | REINFORCED TO RECEIVED THIS TYPE OF SOFFIT. SEE TRUSS | | | SPACING. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | 11- SPECIFY SIZE, LOCATION,DESIGN PRESSURESAND | | | NUMBER OFEXISTING SLIDING GLASS DOORS TO BE REPLACED | | | AS DESCRIBEDON PERMIT APPLICATION. SEC. 106.1.2 CITY | | | AMENDMENTS TO FBC 2004. | | | | | | 12- SPECIFY ATTIC ACCESS SIZE. SEC. R807 2004 FLORIDA | | | RESIDENTIAL CODE. | | | | | | 13- SHEET A-3: | | | A) MISSING SHEET A-6 SHOWING DETAILS A/A-6, B/A-6. | | | | | | B) ROOFING FRAMING PLAN:SPECIFY CALCULATED UPLIFT | | | LOADS AT THE ENDS OF PORCH MICROLLAM WHERE SIMPSON | | | HU410 CONNECTORS WHERE SPECIFIED. SEC. 106.1.2 CITY | | | AMENDMENTS TO FBC 2004. | | | | | | C) ROOF TRUSS DESIGN LOADS CHART IS MISSING THE | | | ATTIC LIVE LOAD AS REQUIRED BY TABLER301.5 OF 2004 | | | FLORIDA RESIDENTIAL CODE. | | | | | | D) SIMPSON HGA 10 CONNECTOR SPECIFIED ON SECTION | | | 4/A-3IS A WOOD TO WOOD CONNECTOR. NEED TO SPECIFY | | | MASONRY CONENCTOR. REVISE AS REQUIRED. | | | | | | 14- PROVIDE DRAINAGE PLANS TO SHOW COMPLIANCE WITH SEC. | | | R401.3 2004 FLORIDA RESIDENTIAL CODE. | | | | | | 15- BUILDING IS LOCATED ON FLOOD ZONE A5.NEED TO | | | SPECIFYFINISH FLOOR ELEVATION AND WILL NEED THE FLOOR | | | ELEVATION CERTIFICATETO GET FINAL C.O. | | | | | | 16- ENERGY CALCULATIONS: | | | A) MAKE SURE A/C AREA MATCHES REVISED A/C AREA ON | | | ARCHITECTURAL PLANS. | | | | | | B) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM. | | | | | | 17- PROVIDE DETAIL/SECTION FOR 2X STRUCTURAL BUCK | | | DETAIL AS REQUIRED BY SWING DOOR PRODUCT APPROVAL | | | SUBMITTED.SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2008-01-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-01-02 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-01-02 |
Time |
09:42 |
Sent To |
PC |
|
| Notes |
| 2008-01-02 09:45:25 | REVISED PANEL SCHEDULE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2007-12-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-12-13 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-12-13 |
Time |
11:13 |
Sent To |
Z |
|
| Notes |
| 2007-12-13 11:14:05 | ** PROVISO ** | | | | | | 1) NOTE: PLEASE SEE THE PANEL SCHEDULE WHICH STILL | | | INDICATES CIRCUITS FOR KITCHEN AND OTHER AREAS WHICH | | | ARE NOW SHOWN AS J-BOX ON PLANS. | | | PLEASE REVISE BEFORE INSPECTIONS. | | | 408.4, 310.16 | | | FBC 106.3.5.1.2, 106.1.2 | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2007-11-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-09 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-09 |
Time |
11:54 |
Sent To |
P |
|
| Notes |
| 2007-11-09 12:02:15 | ** DENIEDREVISION/ NOT APPLICABLE ** | | | | | | | | | 1) NOTE:PLANS SUBMITTED ARE LABELED FOR REVISION #4 | | | BASED ON TITLE BLOCK AND PLANS. | | | NO CLEAR CHANGE IN ELECTRICAL. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTIONS SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-06-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-11 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-11 |
Time |
15:17 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-05-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-05-09 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-05-09 |
Time |
09:08 |
Sent To |
Z |
|
| Notes |
| 2007-05-09 12:58:41 | ** UNSAT 3RD REVIEW ** | | | | | | ** PLEASE SEE SOME COMMENTS FROM PREVIOUS REVIEW, ALONG | | | WITH NEW COMMENTS NEED TO BE ADDRESSED. SOME NEW | | | COMMENTS ARE BASED ON REVISED ITEMS ON RISER WHICH WERE | | | NOT PART OF PREVIOUS PLANS. | | | PLEASE SEE NEW COMMENTS ALSO. | | | | | | 1) NOTE: PLEASE COORDINATE THE RISER WITH THAT OF THE | | | GENERATOR EQUIPMENT, SPECS/CUT SHEETS SUBMITTED. | | | PLEASE SEE THE SPECS INDICATE AN ATS AND PANEL | | | COMBINATION WHICH WAS SUBMITTED ALONG WITH SPECS FOR A | | | STRAIGHT ATS ONLY. PLEASE CORRELATE WHICH ONE WILL BE | | | USED, HIGH-LIGHT AND ADJUST PLANS AS NEEDED. | | | PLEASE SEE MISSING DISCONNECTING MEANS AS THE SPECS ARE | | | UNCLEAR WHICH IS BEING USED. | | | PLEASE SEE THE LOAD ON THE GENERATOR EXCEEDS THAT OF | | | THE SIZE OF THE GENERATOR UNDER NATURAL AND PROPANE | | | GAS. | | | PLEASE SEE THE RISER HAS NOW BEEN REVISED TO SHOW 3/0 | | | CONDUCTOR SIZES FOR FEEDERS FROM 100AMP DISCONNECT TO | | | THE ATS, ATS TO SUB PANEL AND THE FROM THE GENERATOR TO | | | THE ATS. PLEASE KNOW THAT BASED ON THE BREAKER ON THE | | | GENERATOR BEING AT 65AMPS, AND THE REST OF THE | | | EQUIPMENT BEING SIZED AT 100AMPS, THE 3/0 CONDUCTORS | | | WILL NOT FIT UNDER LUGS ETC. | | | PLEASE SEE PIPE FILL OF 3/0'S IF INSTALLED AND ALSO | | | TYPE OF ADAPTERS FROM 3/0'S DOWN TO LUGS UNDER THE | | | BREAKERS FOR SMALLER EQUIPMENT. | | | PLEASE SEE THE SPECS UNDER ONE OF THE ATS PANELS AS | | | STATED WHICH REQUIRES BREAKERS FOR BEDROOM BRANCH | | | CIRCUITS TO BE CHANGED OUT. (210.12)(DEPENDS ON | | | EQUIPMENT USED.) | | | PLEASE SEE PLUMBING REVIEW NOTES AS NO GAS RISERWAS | | | SHOWN. (NOT AN ELECTRICAL COMMENT) | | | PLEASE SEE SPEC SHEETS FOR GENERATOR REQUIRES SLAB TO | | | BE 6 INCHES LARGER THAN THE GENERATOR IN EACH | | | DIRECTION, THIS WILL AFFECT THE 24X48 SLAB AS SHOWN. | | | ** PLEASE COORDINATE ALL OF THE ABOVE. | | | 90.7, 110.3, 310.16, 240.4, TABLES CHAPTER 9, 702.5, | | | 225.31-225.39. ETC | | | | | | 2) NOTE: PLEASE INDICATE THE AIC RATINGS FOR THE NEW | | | MAINS AT THE NEW SERVICE. | | | 110.9 | | | FBC 106.1.2 | | | | | | 3) NOTE: PLEASE SEE MISSING EQUIPMENT GROUNDING | | | CONDUCTOR FROM THE MAIN DISCONNECT AT MAIN HOUSE TO THE | | | CABANA DISCONNECT. 250.32, 250.110, 250.122 | | | | | | 4) NOTE: PLEASE SEE THE NEW GROUNDING ELECTRODE AT THE | | | DETACHED BUILDING NOW STATES THE SLAB STEEL, PLEASE | | | INDICATE THE *FOOTER* STEEL AS THE CONNECTION IS | | | REQUIRED FOR THE STEEL WHICH WOULD LOCATED WITHIN THE | | | 2INCHES OF THE BOTTOM OF THE FOOTER. 250.50, 250.32. | | | (ONLY NEED TO CHANGE THE WORDING OF SLAB TO FOOTER.) | | | | | | 5) NOTE: PLEASE SEE THE FIRST REVIEW WHICH SPOKE OF THE | | | REQUIREMENT TO SHOW THE SMOKE DEVICE AS SMOKE ALARM IF | | | 120V WHICH DETECTS AND SOUNDS AN ALARM. THIS WAS | | | REDLINED ON THE SECOND REVIEW AND NOTED ON REVIEW ABOUT | | | THE AFCI REQUIREMENT BUT NO CHANGES WERE MADE TO THE | | | SYMBOL FOR THE SMOKE DEVICE. THIS COULD BE REDLINED, | | | HOWEVER AS PLANS ARE COMING BACK FOR OTHER COMMENTS, | | | PLEASE MAKE THE ADJUSTMENT AT THIS TIME. PLEASE SEE | | | SYMBOL LEGEND, PLANS, AND PANEL SCHEDULE WHICH ALL CALL | | | FOR *SMOKE DETECTOR*. | | | PLEASE SEE NFPA-72 DEFINITIONS, THE FBC. | | | | | | 6) NOTE: PLEASE SEE PREVIOUS NOTES WHICH REQUESTED THE | | | CODES TO BE ADDED TO THE ELECTRICAL SHEETS FOR 2005 | | | NFPA-70 (NEC) AND 2002 NFPA-72. ONLY THE 2002 NFPA-72 | | | WAS ADDED TO PLANS. | | | PLEASE SEE OTHER SECTIONS OF CODES BEING QUOTED ON | | | PLANS ON LIEU OF SHOWING CODE COMPLIANT DETAIL MAY NOT | | | BE USED. | | | | | | 7) NOTE: PLEASE SEE THE PANEL ON RISER MENTIONS | | | 32CIRCUIT PANEL, PANEL SCHEDULE SHOWS 30 CIRUCITS? | | | 408.4, | | | FBC 106.1.2 | | | | | | 8) NOTE: PLEASE CLARIFY THE STACK WASHER AND DRYER. THE | | | PLANS SHOW ONE RECEPTACLE OUTLET, YET THE PANEL | | | SCHEDULE SHOWS WHAT APPEARS AS TWO SEPARATE SINGLE POLE | | | CIRCUITS? | | | IF THIS IS INDEED A SINGLE RECEPTACLE, WOULD THIS NOT | | | BE A 2-POLE BREAKER? | | | PLEASE SEE 210.4 AND THE NEXT COMMENT FOR SINGLE YOKES | | | BEING FED FROM MORE THAN ONE CIRCUIT. | | | | | | 9) NOTE: PLEASE SEE 210.4 AS THE DISHWASHER AND | | | DISPOSAL IF BEING FED FROM THE SAME RECEPTACLE/YOKE | | | MUST BE ON A 2-POL BREAKER. PLEASE REVISE PLANS TO SHOW | | | TWO DEDICATE RECEPTACLES OR SHOW A 2-POLE BREAKER WHICH | | | FEEDS THIS. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-04-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-04-13 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-04-13 |
Time |
10:16 |
Sent To |
M |
|
| Notes |
| 2007-04-13 14:43:42 | ** UNSAT 2ND REVIEW ** | | | | | | ** PLEASE SEE THAT AS THE PLANS HAVE SUBSTANTIALLY | | | CHANGED FROM PREVIOUSLY SUBMITTED PLANS, THERE ARE NEW | | | COMMENTS. | | | NOTES ON PREVIOUS REVIEW MENTION AS THERE WERE SEVERAL | | | ITEMS NOT SUBMITTED FOR REVIEW THERE MAY BE NEW | | | COMMENTS ON THIS REVIEW. | | | | | | 1) NOTE:PLEASE SUBMIT ONLY THE MANUFACTURES SPECS/CUT | | | SHEETS WHICH INDICATE THE MAIN EQUIPMENT FOR THE | | | GENERATOR AND ATS. PLEASE SEE THE DOCUMENTS WHICH ARE | | | THE MAINTENANCE AND PARTS LIST SHEETS ARE NOT NEEDED. | | | PLEASE BE SURE THE SPECS INDICATE THE MINIMUM | | | CLEARANCES FOR THE EQUIPMENT AND SURROUNDING | | | CLEARANCE. | | | PLEASE KNOW THAT THE LATEST INFORMATION FROM GENERAC IS | | | THAT THIS PARTICULAR EQUIPMENT REQUIRES A MINIMUM OF | | | 3FT AROUND EQUIPMENT FOR PROPER VENTILATION. PLEASE SEE | | | THE GENERATOR AT THIS TIME IS SHOWN TOO CLOSE TO | | | DWELLING. PLEASE ALSO SEE MECHANICAL COMMENTS FOR | | | MINIMUM CLEARANCES FOR EXHAUST WHICH MAY BE REQUIRED TO | | | BE 5FT FROM OPENING INTO BUILDING. | | | ** PLEASE BE SURE TO REVISE ALL SHEETS WHICH INDICATE | | | THIS LOCATION OF THE GENERATOR ETC. | | | 110.3, 90.7. | | | FBC 106.1.2 | | | | | | 2) NOTE: PLEASE INDICATE THE MINIMUM LEVEL FOR THE | | | GENERATOR WHICH IS REQUIRED TO BE A MINIMUM OF 6INCHES | | | ABOVE THE BFE. | | | PLEASE SEE THE PLANS INDICATE THIS IN A FLOOD ZONE A5, | | | AND BEFORE FINAL AN ELEVATION CERTIFICATE WILL BE | | | REQUIRED FOR EQUIPMENT AND GENERATOR. | | | | | | 3) NOTE: PLEASE SEE NEW RISER DIAGRAM WHICH IS NOW | | | SUBMITTED FOR REVIEW FOR THE FIRST TIME. | | | PLEASE SEE 250.6 AND 250.24B AS *EQUIPMENT GROUNDING | | | CONDUCTORS* ARE NOT TO BE INSTALLED BEFORE THE FIRST | | | MEANS OF DISCONNECT. THIS CREATES OBJECTIONABLE | | | CURRENT. | | | PLEASE SEE RISER AND ADJUST. | | | | | | 4) NOTE: PLEASE SEE THE RISER DOES NOT INCLUDE THE | | | GROUNDING ELECTRODE SYSTEM AT THE DETACHED BUILDING AS | | | REQUIRED PER 250.32. | | | PLEASE SEE 250.50 AND 250.66. *QUOTING THE CODE IN LIEU | | | OF SHOWING SPECIFIC DETAIL IS NOT PERMITTED. PLEASE | | | SHOW DETAIL OF THIS. | | | | | | 5) NOTE: PLEASE SEE RISER AND NEW PANEL. PLEASE | | | INDICATE HOW THE NEW ATS IS BEING FED. PLEASE SEE THE | | | PANEL SCHEDULE FOR THE CABANA SHOWS ALL OF THE CIRCUITS | | | BEING FED FROM THIS PANEL AND NOT CIRCUITS FROM THE NEW | | | ATS PANEL???? | | | PLEASE INDICATE THE OCP TO NEW ATS PANEL. PLEASE | | | INDICATE THE CIRCUITS AND LOADS WHICH ARE BEING | | | PROPOSED ON THIS NEW ATS PANEL. | | | PLEASE SEE NO CONDUCTORS, OCP ETC ARE BEING SHOWN ON | | | PANEL? | | | PLEASE COMPLETE. | | | 408.4, 240.4, 310.16 ETC. | | | FBC 106.3.5.4 | | | | | | 6) NOTE: PLEASE CORRELATE PLANS FOR NEW ATS PANEL | | | LOCATION. PLEASE SEE SHEET A-2 WHICH INDICATES THE | | | ATS/PANEL OUTSIDE, YET THIS PANEL IS AN INDOOR PANEL | | | WHICH IS LISTED AND RATED AS A NEMA 1 PANEL. PLEASE | | | KNOW, IF LOCATING THE ATS PANEL OUTSIDE, PLEASE INCLUDE | | | SPECS FOR THE ATS WHICH IS RATED FOR NEMA 3 LOCATIONS. | | | PLEASE SEE ELECTRICAL PLANS INDICATE THIS SAME | | | EQUIPMENT INSIDE?? | | | PLEASE CORRELATE. | | | 110.3, 90.7 | | | FBC 106.1.2 | | | | | | 7) NOTE: PLEASE SEE 422.13 WHICH REQUIRES ALL ELECTRIC | | | TYPE WATER HEATERS LOADS TO BE SHOWN AT 125%. PLEASE | | | SEE THE 2005 NEC. | | | | | | 8) NOTE: PLEASE INDICATE THE FOLLOWING APPROPRIATE | | | CODES ON THE ELECTRICAL SHEETS. | | | 2005 NFPA-70 (NEC) AND 2002 NFPA-72. | | | | | | 9) NOTE: PLEASE SEE MISSING REQUIRED DEDICATED BATH | | | CIRCUITS PER 210.52D, 210.11C3. | | | PLEASE SEE THAT THE SIZE OF THE BRANCH CIRCUIT AS SHOWN | | | ON PLANS IS NOT CORRECT. | | | | | | 10) NOTE: PLEASE CLARIFY THE STACK WASHER DRYER ON LOAD | | | CALCULATIONS, AS THIS IS SHOWN AS 2-POLE 30AMP ON PANEL | | | SCHEDULE? PLEASE CLARIFY. | | | FBC 106.1.2 | | | | | | 11) NOTE: PLEASE SEE 210.12 AS AFCI PROTECTION IS | | | REQUIRED ON THE SMOKE ALARM DEVICE(S). THIS SHOULD BE | | | ON ONE OF THE OTHER CIRCUITS AS SHOWN ON PLANS. PLEASE | | | ALSO SEE THAT THE PLANS INDICATE THE DEVICE AS A SMOKE | | | DETECTOR AND THE PANEL SCHEDULE INDICATES SMOKE ALARMS. | | | PLEASE COORDINATE. | | | | | | 12) NOTE: PLEASE BE SURE THE SEAL FROM DESIGNER OF | | | RECORD IS CLEAR AND VISIBLE WITH ALL INFORMATION ON | | | SAID SEAL. | | | FS481.221 | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-02-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-08 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-07 |
Time |
16:54 |
Sent To |
M |
|
| Notes |
| 2007-02-08 09:31:03 | ***** UNSAT ***** | | | | | | | | | 1) NOTE: PLEASE SEE THE PLANS SHALL STATE THE FOLLOWING | | | MINIMUM CODES FOR DESIGN. | | | 2005 NFPA-70 AND THE 2002 NFPA-72 | | | | | | 2) NOTE: PLEASE SEE ZONING COMMENTS FOR THE SIZE OF THE | | | STRUCTURE ALONG WITH THE SEPARATE METERED SERVICE WHICH | | | IS NOT PERMITTED AS THIS IS ZONED SF-7. | | | PLEASE SEE COMMENTS ALSO WITH RESPECT TO THE LOCATION | | | OF THE GENERATOR. | | | PLEASE KNOW AT THIS TIME THE RISER WILL NEED TO BE | | | COMPLETELY REVISED TO FEED THE NEW CABANA FROM THE | | | EXISTING HOUSE. | | | | | | 3) NOTE: PLEASE SEE THAT LOCATION OF THE GENERATOR IS | | | NOT PERMITTED PER ZONING, PLEASE ALSO SHOW AND INDICATE | | | ALL DISTANCES FROM ALL SURROUNDING WALLS, WINDOWS, | | | SOFFIT OPENINGS ETC. | | | PLEASE SUBMIT ALL MANUFACTURES SPECS/CUT SHEETS FOR THE | | | PROPOSED GENERATOR, ATS ETC. WHAT IS THE PRIME-MOVER? | | | PLEASE BE SURE THE MANUFACTURES CUT SHEETS INDICATE THE | | | MINIMUM CLEARANCES REQUIRED. | | | PLEASE SEE THAT THE ATS SHALL BE SERVICE ENTRANCE | | | RATED, MEANS OF DISCONNECT FOR THE GENERATOR SHALL MEET | | | 702.6, 702.11 | | | 90.7, 110.3, 230.70, 230.76, 230.79 ETC | | | FBC 106.1.2 | | | | | | 4) NOTE: PLEASE SEE RISER WHICH SHOWS AND EQUIPMENT | | | GROUNDING CONDUCTOR FROM THE METER TO THE FIRST MEANS | | | OF DISCONNECT. PLEASE KNOW THAT EVEN THOUGH THE METER | | | IS COMING OUT, PLEASE KNOW THAT IN ANY CASE AN * | | | EQUIPMENT GROUNDING CONDUCTOR* IS NOT INSTALLED UNTIL | | | AFTER THE FIRST MEANS OF DISCONNECT. | | | 250.6, 250.24 | | | | | | 5) NOTE: PLEASE SEE MISSING COUNTER SPACE GFI | | | RECEPTACLES AS THIS IS BEING NOTED AS A KITCHEN WITH | | | SMALL APPLIANCE CIRCUITS ETC. | | | PLEASE SEE 210.52C1-5. MISSING COUNTER AND PENINSULAR. | | | | | | 6) NOTE: PLEASE SEE NFPA-72 11.8.3 AS A SMOKE DETECTOR | | | OR SMOKE ALARM IS NOT PERMITTED WITHIN 20FT OF ANY | | | COOKING APPLIANCES UNLESS MEETING THE EXCEPTIONS OF | | | THIS SECTION FOR THE TYPE OF DEVICE BEING INSTALLED. | | | PLEASE KNOW THAT A MEETING WAS HELD AT THE SOUTHERN | | | SECTION MEETING IN OCT 06 WHERE WE WERE DIRECTLY | | | INFORMED BY NFPA THAT THE USE OF SD FOR SMOKE DETECTORS | | | ON PLANS FOR RESIDENTIAL HOMES IS NOT ACCEPTABLE WHEN | | | THESE DEVICES ANY ACTUALLY FALL UNDER THE DEFINITIONS | | | OF SMOKE ALARMS WHICH WOULD BE SHOWN AS SA/SMOKE | | | ALARMS. | | | THIS INFORMATION WAS NEW TO THIS AHJ AS THE GENERAL USE | | | OF THE SD FOR SMOKE DETECTORS WAS ALWAYS ACCEPTED. | | | BY THE DEFINITIONS AS STATED IN NFPA-72 A SD/ SMOKE | | | DETECTOR IS ONLY A DEVICE WHICH WILL DETECT AND WILL | | | NOT SOUND AN AUDIBLE ALARM. THIS WOULD BE DONE BY | | | HORN/SIREN TYPE DEVICES. PLEASE SEE THE DEFINITIONS OF | | | SA/SMOKE ALARMS; THESE ARE DEVICES WHICH ARE 120V (AS | | | SHOWN) AND WOULD DETECT AND SOUND AN ALARM. THIS IS | | | SOMETHING THAT IS NOW BEING COMMENTED ON OTHER REVIEWS | | | FOR OTHER NEW HOMES. | | | ** PLEASE SEE THAT SMOKE ALARMS ARE STATED IN THE FBC | | | RESIDENTIAL CODE/ FBC AND IN NFPA-72. | | | IF THERE ARE ANY QUESTIONS ON THIS COMMENT PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE. | | | | | | 7) NOTE: PLEASE CLARIFY THE PLANS WHICH INDICATE A | | | STACK WASHER /DRYER. PLEASE SEE COMMENT WITH RESPECT TO | | | MISSING PANEL SCHEDULE BELOW. | | | 106.1.2 | | | | | | 8) NOTE: PLEASE SUBMIT A COMPLETE PANEL SCHEDULE FOR | | | ALL CIRCUITS, OVER CURRENT PROTECTION DEVICES AND | | | CONDUCTOR SIZES SHOWING ALL OF THE MINIMUM REQUIRED | | | CIRCUITS. | | | 210.52, 210.11, 220, 408.4. PLEASE SEE THE FOLLOWING | | | TEXT FROM THE CODE COMMENTARY WHICH STATES * THE CODE | | | TO REQUIRE THAT THE IDENTIFICATION FOR EVERY CIRCUIT | | | SUPPLIED BY A PANEL-BOARD OR SWITCHBOARD BE LEGIBLE AND | | | CLEARLY STATE THE SPECIFIC PURPOSE FOR WHICH THE | | | CIRCUIT IS USED. CIRCUITS USED FOR THE SAME PURPOSE | | | MUST BE IDENTIFIED AS TO THEIR LOCATION. FOR EXAMPLE, | | | SMALL APPLIANCE BRANCH CIRCUITS CAN SUPPLY OUTLETS IN | | | THE KITCHEN, DINING ROOM, AND KITCHEN COUNTERTOPS. | | | IDENTIFYING THE CIRCUITS AS SMALL APPLIANCE BRANCH | | | CIRCUITS IS NOT ACCEPTABLE; INSTEAD, THEY SHOULD BE | | | IDENTIFIED AS ``KITCHEN WALL RECEPTACLES,'' ``DINING | | | ROOM FLOOR RECEPTACLE,'' OR ``KITCHEN COUNTERTOP | | | RECEPTACLES LEFT OF SINK.'' CIRCUIT DIRECTORIES | | | CONTAINING MULTIPLE ENTRIES WITH ONLY ``LIGHTS'' OR | | | ``OUTLETS'' DO NOT PROVIDE THE SUFFICIENT DETAIL | | | REQUIRED BY THIS SECTION. | | | | | | 9) NOTE: PLEASE SUBMIT THE FOLLOWING INFORMATION WHEN | | | RISER IS REVISED WHICH WILL BE FED FROM THE MAIN HOUSE | | | SERVICE. PLEASE INDICATE THE OVER CURRENT PROTECTION | | | FOR NEW FEEDERS FROM THE EXISTING SERVICE. PLEASE | | | SUBMIT COMPLETE LOAD CALCULATIONS ON THE EXISTING | | | SERVICE WHICH WILL INCLUDE THE LOADS FOR THE NEW. | | | SHOW ALL FEEDERS AND GROUNDING ELECTRODE SYSTEM. ETC | | | DISCONNECTING MEANS AT THE DETACHED BUILDING ETC. | | | 215.5, 220, 240.4, 408.4, 310.16, 250.32, 225.31 ETC | | | 106.1.2, 106.3.5.4 | | | | | | 10) NOTE: PLEASE BE SURE TO INCLUDE THE REQUIRED | | | DEDICATED BATH(S) CIRCUIT(S) PER 210.52D, 210.11C3. | | | MUST BE 20AMP AND #12. | | | | | | 11) NOTE: PLEASE SEE MISSING ARC FAULT PROTECTION PER | | | 210.12B. (THE AREA OUTSIDE KITCHEN IS BEING CONSIDERED | | | ADAPTABLE SLEEPING ROOM WHICH WILL REQUIRE THIS | | | PROTECTION FOR ALL OUTLETS). | | | | | | 12) NOTE: PLEASE SEE THE MISSING PRINTED LICENSE NUMBER | | | ON THE TITLE BLOCKS FOR THE DESIGNER OF RECORD ON | | | SHEETS. | | | FAC 61G1-16.004 | | | | | | 13) NOTE: PLEASE SEE THE ADDRESS AS ASSIGNED IS 122 AS | | | THE PREVIOUS HOUSE AT 126 IS NO LONGER PRESENT AND THIS | | | IS NOW PART OF THE 122 LEGAL ADDRESSED PROPERTIES. | | | PLEASE ADJUST TITLE BLOCKS. | | | | | | 14) NOTE: PLEASE KNOW THAT AT THIS TIME AS THERE ARE | | | MANY ITEMS WHICH WERE NOT SUBMITTED AND THERE ARE ITEMS | | | WHICH CAN NOT BE REVIEWED FOR CODE COMPLIANCE THERE MAY | | | BE NEW COMMENTS ON THE FOLLOWING REVIEW WHICH ARE NOT | | | PRESENT ON THIS REVIEW. | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-02-07 16:55:02 | IN ELEC FOR REVIEW. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2007-06-18 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-06-18 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-06-18 |
Time |
13:48 |
Sent To |
PC |
|
| Notes |
| 2007-06-18 13:50:15 | NOTE: GAS PERMIT APPROVED ON PERMIT #07050861 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2007-05-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-05-16 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-05-16 |
Time |
14:53 |
Sent To |
M |
|
| Notes |
| 2007-05-16 14:57:35 | | | | GAS PERMIT REQUIRED. A LICENSED PLUMBING OR GAS | | | CONTRACTOR SHALL MAKE APPLICATION AND SUBMIT PLANS FOR | | | APPROVAL. NO GAS PIPING SHALL BE INSTALLED BEFORE | | | PERMIT IS ISSUED. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2007-12-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-10 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-10 |
Time |
14:12 |
Sent To |
E |
|
| Notes |
| 2007-12-10 14:13:21 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-11-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-14 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-14 |
Time |
16:47 |
Sent To |
P |
|
| Notes |
| 2007-11-14 16:47:40 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-11-06 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-11-08 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-06 |
Time |
11:04 |
Sent To |
Z |
|
| Notes |
| 2007-11-06 11:04:25 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-11-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-02 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-02 |
Time |
11:18 |
Sent To |
P |
|
| Notes |
| 2007-11-02 11:18:50 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-06-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-11 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-11 |
Time |
09:28 |
Sent To |
E |
|
| Notes |
| 2007-06-11 09:28:37 | TO "DPALMER" DESK/RESUB--NEW SHEETS FOR "P" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-05-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-15 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-15 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2007-05-15 14:54:30 | TO "P" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-05-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-03 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-03 |
Time |
15:13 |
Sent To |
E |
|
| Notes |
| 2007-05-03 15:13:54 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-05-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-03 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-03 |
Time |
15:11 |
Sent To |
E |
|
| Notes |
| 2007-05-03 15:11:47 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-04-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-12 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-12 |
Time |
09:46 |
Sent To |
E |
|
| Notes |
| 2007-04-12 09:46:30 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-04-04 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-04-04 |
Time |
17:18 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-04-04 |
Time |
17:18 |
Sent To |
Z |
|
| Notes |
| 2007-04-04 17:18:38 | TO ZONING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-02-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-05 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-05 |
Time |
13:56 |
Sent To |
E |
|
| Notes |
| 2007-02-05 13:57:03 | TO "DPALMER" DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-03-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-03-14 |
Time |
19:00 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-01-31 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2007-01-31 10:12:49 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
N |
Date |
2007-11-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-29 |
Time |
14:25 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-11-29 |
Time |
14:25 |
Sent To |
B |
|
| Notes |
| 2007-11-29 14:27:13 | BUILDING PLAN REVISION, NO REVISIONS TO MECHANICAL | | | PLAN. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-05-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-05-17 |
Time |
08:20 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-05-17 |
Time |
08:20 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-04-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-04-16 |
Time |
09:09 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-04-16 |
Time |
09:09 |
Sent To |
P |
|
| Notes |
| 2007-04-16 09:43:49 | *** DENIED *** | | | 1) AS REQUESTED IN LAST REVIEW 2-12-07 NOTE #3,PLEASE | | | SUBMIT COMBUSTION AIR CALCULATIONS OR PROVIDE | | | COMBUSTION AIR FOR ALL NEW GAS APPLIANCES (GAS CLOTHES | | | DRYER AND GAS WATER HEATER), PER 2004 FBC/R M1701.1. | | | | | | 2) SEE GAS CLOTHES DRYER LOCATION ON PLANS, REFER TO | | | 2004 FBC/R M1701.4 PROHIBITED SOURCES. | | | COMBUSTION AIR DUCTS AND OPENINGS SHALL NOT CONNECT | | | APPLIANCE ENCLOSURES WITH SPACE IN WHICH THE OPERATION | | | OF A FAN MAY ADVERSELY AFFECT THE FLOW OF COMBUSTION | | | AIR. COMBUSTION AIR SHALL NOT BE OBTAINED FROM AN AREA | | | IN WHICH FLAMMABLE VAPORS PRESENT A HAZARD. FUEL-FIRED | | | APPLIANCES SHALL NOT OBTAIN COMBUSTION AIR FROM ANY OF | | | THE FOLLOWING ROOMS OR SPACES: | | | 1.SLEEPING ROOMS. | | | 2.BATHROOMS. | | | 3.TOILET ROOMS. | | | | | | 3) PLEASE SHOW THE LOCATION OF THE CLOTHES DRYER VENT | | | ON MECHANICAL PLANS. CLOTHES DRYER VENT TERMINATION MAY | | | NOT DISCHARGE NEAR THE A/C CONDENSER UNIT OR POOL | | | HEATER, PER 2004 FBC/M 501.2 . | | | | | | 4) PLEASE SHOW LOCATION OF A/C CONDENSER UNIT ON | | | MECHANICAL PLANS. | | | | | | 5) PLEASE BE AWARE THE GENERATOR MAY NOT BE WITHIN 5 | | | FEET OF THE DOOR TO THE STORAGE ROOM, SEE NFPA 37. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-02-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-12 |
Time |
14:30 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2007-02-12 |
Time |
14:29 |
Sent To |
P |
|
| Notes |
| 2007-02-12 14:36:25 | *** DENIED *** | | | 1) NO MECHANICAL PLANS WERE SUBMITTED FOR | | | REVIEW. PLEASE SUBMIT MECHANICAL PLANS | | | FOR REVIEW, PER 2004 FBC WPB AMEND. 106.3.5.4. | | | | | | 2) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT | | | ALSO, PER 2004 FBC 13-600.3.ABC.2. | | | | | | 3) PLEASE SUBMIT COMBUSTION AIR CALCULATIONS OR | | | COMBUSTION AIR FOR ALL NEW GAS APPLIANCES, PER 2004 | | | FBC/R M1701.1. | | | | | | 4) PLEASE SUBMIT MANUFACTURER'S SPECIFICATION'S AND | | | INSTALLATION INSTRUCTIONS FOR GAS BBQ GRILL AND HOOD. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2007-12-28 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-12-28 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-12-28 |
Time |
08:30 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
N |
Date |
2007-11-29 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-11-29 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-11-29 |
Time |
13:11 |
Sent To |
M |
|
| Notes |
| 2007-11-29 13:33:08 | REVISION 4 IS FOR GAS. GAS PERMIT # 07050861 REVISION | | | WAS SUBMITTED AND APPROVED ON 11/27/07. | | | IF THERE IS OTHER PLUMBING CHANGES, REMOVE ALL CLOUDS | | | FROM PREVIOUS CHANGES AND CLEARLY SHOW NEWCHANGES. | | | PLUMBING PLAN REVIEW BY | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-06-18 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-06-18 |
Time |
13:44 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-06-18 |
Time |
13:44 |
Sent To |
G |
|
| Notes |
| 2007-06-18 13:46:31 | ****************PROVISO**************** | | | NOTE: PER FBC-2004, PLUMBING, SECTION 909.1 WET VENT | | | PERMITTED: ONLY THE FIXTURES WITHIN THE BATHROOM GROUPS | | | SHALL CONNECT TO THE WET-VENTED HORIZONTAL BRANCH | | | DRAIN. ANY ADDITIONAL FIXTURES SHALL DISCHARGE | | | DOWNSTREAM OF THE WET VENT. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-05-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-05-16 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-05-16 |
Time |
14:50 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-04-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-04-16 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-04-16 |
Time |
14:28 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-02-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-02-13 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-02-13 |
Time |
08:06 |
Sent To |
B |
|
| Notes |
| 2007-02-13 08:32:20 | DENIED; | | | 1. SANITARY RISER DIAGRAM; | | | A) SINKS AND W/M TO DISCHARGE DOWN STREAM OF THE | | | BATHROOM SINK. SECTION 909.1 WET VENTS. | | | B) AUTOMATIC CLOTHES WASHER BRANCH DRAIN TO BE | | | 3" WITH A C.O. AT 48" AFF. VENT REQUIRED. | | | 2. SHOW ON PLANS THE TYPE OF THERMAL EXPANSION CONTROL | | | TO BE USED . SECTION 607.3. | | | 3.ADD NOTE TO PLAN, HOT WATER PIPES TO BE INSULATED, | | | PER ENERGY CODE SECTION 13-612.1. | | | 4. PLANS MUST BE APPROVED BY ZONING BEFORE PLUMBING | | | PLAN REVIEW CAN BE COMPLETE. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
6 |
Status |
P |
Date |
2007-12-18 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-12-18 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-12-18 |
Time |
14:19 |
Sent To |
P |
|
| Notes |
| 2007-12-18 14:19:36 | ***PROVISO*** | | | | | | 1) ALL MECHANICAL EQUIPMENT (I.E. POOL EQUIP., | | | CONDENSING UNIT, AND GENERATOR) SHALL BE A MINIMUM OF | | | ONE (1) FOOT FROM THE WEST PROPERTY LINE AND AT LEAST | | | 11 FEET FROM THE SOUTH PROPERTY LINE. | | | | | | 2) THERE SHALL TO NO COOKING FACILITIES AND THIS CANNOT | | | BE A SEPARATE DWELLING UNIT. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2007-11-08 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-11-08 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-11-08 |
Time |
11:29 |
Sent To |
E |
|
| Notes |
| 2007-11-08 11:29:41 | ***PROVISO*** | | | | | | 1) ALL MECHANICAL EQUIPMENT (I.E. POOL EQUIP., | | | CONDENSING UNIT, AND GENERATOR) SHALL BE A MINIMUM OF | | | ONE (1) FOOT FROM THE WEST PROPERTY LINE AND AT LEAST | | | 11 FEET FROM THE SOUTH PROPERTY LINE. | | | | | | 2) THERE SHALL TO NO COOKING FACILITIES AND THIS CANNOT | | | BE A SEPARATE DWELLING UNIT. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2007-05-14 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-05-14 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-05-14 |
Time |
16:54 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-04-11 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-04-11 |
Time |
19:44 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-04-11 |
Time |
19:44 |
Sent To |
I |
|
| Notes |
| 2007-04-11 19:48:13 | ***PROVISO*** | | | | | | 1) ALL MECHANICAL EQUIPMENT (I.E. POOL EQUIP., | | | CONDENSING UNIT, AND GENERATOR) SHALL BE A MINIMUM OF | | | ONE (1) FOOT FROM THE WEST PROPERTY LINE AND AT LEAST | | | 11 FEET FROM THE SOUTH PROPERTY LINE. | | | | | | 2) REF/FREEZER IN THE CABANA SHALL ONLY BE | | | UNDER-THE-COUNTER.THERE SHALL TO NO COOKING | | | FACILITIES AND THIS CANNOT BE A SEPARATE DWELLING | | | UNIT. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2007-11-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2007-02-03 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2007-02-03 |
Time |
11:49 |
Sent To |
I |
|
| Notes |
| 2007-02-03 13:29:15 | DENIED, | | | 1. SHALL APPLY FOR A SEPARATE PERMIT FOR THE PROPOSED | | | FENCE WITH EASEMENT APPROVAL FROM THE CITY OF WEST PALM | | | BEACH UTILITY DEPT. | | | 2. SHALL PROVIDE THE DISTANCE OF THE PROPOSED LANI AND | | | CANBANA COVERED PORCH ON TWO COPIES OF | | | SITEPLANS/SURVEYS. | | | 3. THE REF. IN THE POOL CABANA SHALL BE AN U/C REF. NO | | | COOKING FACILITY SHALL BE ALLOWED AND CABANA SHALL NOT | | | BE USED AS A SEPARATE LIVING SPACE. | | | 4. CANNOT HAVE A SEPARATE ELECTRICAL SERVICE AT | | | LOCATION, SHALL BE FED FROM THE MAIN STRUCTURE, ZONED | | | SF7. | | | 5. PLEASE PROVIDE A COPY OF THE UNITY OF TITLE FOR THE | | | PROPERTY (UNIFYING THE PROPERTY AS ONE) AND REFERECE | | | THE DEMO PERMIT FOR THE STRUCTURE ON THE PROPERTY. | | | 6. THE PROPOSED POOL EQUIPMENT AND GENERATOR SHALL | | | SHOWN ON THE TWO COPIES OF SITEPLANS. | | | 7. THE PROPOSED POOL QUIPMENT. A/C UNIT AND GENERATOR | | | SHALL BE NO CLSOER THAN 11.7FT FROM THE REAR PROPERTY | | | LINE. | | | 8. THE SUBMITTED SITEPLANS DOES NOT SHOW THE POOL | | | EQUIPMENT AND GENERATOR. | | | 9. THE PROPOSED CABANA INCLUDING ROOF COVERED PORCH | | | CANNOT EXCEED THE 1000SQ FT TOTAL. SEC 94-304(B)(1) | | | MAXIMUM SQUARE FOOTAGE. THE TOTAL FLOOR AREA OF ALL | | | ROOFED ACCESSORY BUILDINGS ON A PROPERTY SHALL NOT | | | EXCEED 75% OF THE GROSS FLOOR AREA OF THE PRIMARY | | | STRUCTURE WITH A MAXIMUM FLOOR OF 1,000 SQ FEET. THE | | | PROPOSED CABANA WILL EXCEED THE SQUARE FOOTAGE OF TOTAL | | | ROOF. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 | | | |
|
|