 |
Plan Review Details - Permit 07011124
| Plan Review Stops For Permit 07011124 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-11-07 |
|
|
Cont ID |
|
| Sent By |
jjohnsto |
Date |
2007-11-07 |
Time |
17:59 |
Rev Time |
1.00 |
| Received By |
jjohnsto |
Date |
2007-11-07 |
Time |
17:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-09-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-09-12 |
Time |
16:19 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2007-09-12 |
Time |
16:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-02-27 |
Time |
13:51 |
Rev Time |
4.44 |
| Received By |
jwitmer |
Date |
2007-02-27 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2007-02-27 13:54:42 | BUILDING PLAN REVIEW | | | PERMIT: 07011124 | | | ADD: 901 45TH ST / ST. MARY'S MEDICAL CENTER CONT: | | | OVERLAND CONSTRUCTION | | | TEL: (561)683-3210 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1STREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2 ) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF | | | THE COURT. | | | NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS | | | NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE | | | RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: | | | 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT | | | THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3)BRIDGE DESIGN ASSOCIATES SHEET SK-1 ROOF EQUIPMENT | | | CONNECTION IS MISSING THEIR CERTIFICATE OF | | | AUTHORIZATION NUMBER.) 471.023 F.S.CERTIFICATE OF | | | AUTHORIZATION.THE TITLE BLOCK FOR ANY | | | SHEET BEARING THE NAME OF AN ENGINEER | | | PRACTICING UNDER A FICTITIOUS NAME, A | | | CORPORATION, OR A PARTNERSHIP, OFFERING ENGINEERING | | | SERVICES, SHALL INCLUDE THE CERTIFICATE OF | | | AUTHORIZATION NUMBER. | | | ADD THE NUMBER TO EACH SHEET.THIS MAY BE ADDED BY | | | HAND. | | | | | | 4) SHEET X1.1 CODE CRITERIA, FLORIDA BUILDING CODE | | | 2004/ 2006 REVISIONS BUILDING | | | | | | 5) SHEET X1.1 FIRE PROTECTION CRITERIA, THE PLANS | | | INDICATE A TYPE II BUILDING BUT THE FIRE RATINGS DO NOT | | | MATCH, PLEASE | | | SEE IF THE PLANS ARE TO BE A TYPE L TYPE A OR B ? | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-11-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-19 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-19 |
Time |
11:37 |
Sent To |
B |
|
| Notes |
| 2007-11-19 11:38:49 | NEW ELECTRICAL SHEET E-2, WHEN PLANS WERE PREVIOUSLY | | | PASSED. | | | PLANS SENT TO LUIS MARTINEZ. ZONING STILL HAS "FAILED" | | | STATUS FOR NO PERMITS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-08-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-26 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-26 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2007-08-26 17:28:06 | 2007-08-26 17:28:06 | | | OK, | | | STAMPED E-SHEETS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-02-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-04 |
Time |
18:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-04 |
Time |
18:48 |
Sent To |
|
|
| Notes |
| 2007-02-04 18:55:42 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE SEE THE CODES ADOPTED AND IN DESIGN | | | SHALL BE STATED ON THE PLANS. | | | PLEASE KNOW THAT AS OF DECEMBER 8TH, 2006 THE STATE OF | | | FLORIDA ADOPTED THE 2006 REVISIONS TO THE 2004 FBC AND | | | THE 2005 NFPA-70. | | | PLEASE BE SURE TO STATE THE FOLLOWING ON THE PLANS AT A | | | MINIMUM AND ANY OTHERS WHICH MAY BE MENTIONED BY OTHER | | | TRADES. | | | 2004 FBC W/2006 (REVISIONS) | | | 2005 NFPA-70 NEC. | | | | | | 2) NOTE: PLEASE SUBMIT PANEL SCHEDULE FOR NEW | | | CIRCUIT(S) LOADS ON NEW AND EXISTING. PLEASE SHOW THE | | | CONDUCTOR SIZE(S), OVER CURRENT PROTECTION ETC. | | | 408.4, 310.16, 240.4. | | | PLEASE INDICATE ANY CONTINUOUS LOADS AT 125% 215.3, | | | 230.42/ MOTOR LOADS? | | | | | | 3) NOTE: PLEASE INDICATE NEW OR EXISTING SHUNT/SHUT | | | DOWN OF ALL ELECTRICAL UNDER HOOD PER NFPA-96. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-11-09 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-11-09 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-11-09 |
Time |
11:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-09-07 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-09-07 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-09-07 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2007-09-07 15:16:31 | ***DENIED*** | | | A RESPONSE LETTER WAS INCLUDED ADDRESSING OTHER REVIEW | | | COMMENTS. IT WOULD HELP EXPEDITE THIS PROCESS IF A | | | LETTER ADDRESSING FIRE REVIEW COMMENTS WAS PROVIDED | | | INDICATING WHERE INFORMATION MAY BE FOUND IF CORRECTED | | | ON PLANS. | | | | | | 1) THE APPLICATION INDICATES KITCHEN HOOD REPLACEMENT | | | AND THE NARRATIVE ON SHT X1.1 MENTIONS FIRE SUPPRESSION | | | SYSTEM. DOES THE SYSTEM CURRENTLY MEET THE REQUIREMENTS | | | FOR A WET CHEMICAL UL 300 APPLICATION, OR WILL IT BE | | | UPGRADED DURING THE SCOPE OF THIS WORK? | | | | | | 2) PLEASE SHOW LOCATION OF REQUIRED "K" FIRE | | | EXTINGUISHER. | | | | | | 3) IN ADDITION TO LISTED CODES, CONSTRUCTION, | | | ALTERATION AND DEMOLITION SHALL COMPLY WITH NFPA 241. | | | | | | 4) SEPARATE SHOP DRAWINGS AND PERMITS REQUIRED FOR HOOD | | | AND FIRE SUPPRESSION SYSTEMS. | | | | | | 5) WORK SHALL NOT INTERFERE WITH EXISTING BUILDING FIRE | | | PROTECTION EQUIPMENT AND REQUIRED MEANS OF EGRESS. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW(561) 805-6722 | | | FIRE PREVENTION(561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-03-07 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-03-07 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-03-07 |
Time |
10:17 |
Sent To |
|
|
| Notes |
| 2007-03-07 10:28:24 | ***DENIED*** | | | | | | 1) THE APPLICATION INDICATES KITCHEN HOOD REPLACEMENT | | | AND THE NARRATIVE ON SHT X1.1 MENTIONS FIRE SUPPRESSION | | | SYSTEM. DOES THE SYSTEM CURRENTLY MEET THE REQUIREMENTS | | | FOR A WET CHEMICAL UL 300 APPLICATION, OR WILL IT BE | | | UPGRADED DURING THE SCOPE OF THIS WORK? | | | | | | 2) PLEASE SHOW LOCATION OF REQUIRED "K" FIRE | | | EXTINGUISHER. | | | | | | 3) IN ADDITION TO LISTED CODES, CONSTRUCTION, | | | ALTERATION AND DEMOLITION SHALL COMPLY WITH NFPA 241. | | | | | | 4) SEPARATE SHOP DRAWINGS AND PERMITS REQUIRED FOR HOOD | | | AND FIRE SUPPRESSION SYSTEMS. | | | | | | 5) WORK SHALL NOT INTERFERE WITH EXISTING BUILDING FIRE | | | PROTECTION EQUIPMENT AND REQUIRED MEANS OF EGRESS. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW(561) 805-6722 | | | FIRE PREVENTION(561) 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-04-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-10 |
Time |
17:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-10 |
Time |
17:25 |
Sent To |
M |
|
| Notes |
| 2008-04-10 17:25:54 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-10-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-10 |
Time |
12:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-10 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2007-10-26 15:47:02 | TO "COMM" BD#5 | | 2007-10-10 12:21:35 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-08-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-03 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-03 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2007-08-26 17:19:51 | TO COMM BOARD SPACE #59 | | 2007-08-03 15:25:20 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-03-07 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-03-07 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-01-25 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2007-02-02 09:52:00 | TO "COMM" BD#27 | | 2007-01-25 09:23:53 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-05-06 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-05-06 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-04-29 |
Time |
13:57 |
Sent To |
PC |
|
| Notes |
| 2008-05-06 11:14:37 | REVISED PAGE M-3. SEE REDLINE NOTE ON PLANS. CLEANOUTS | | | ARE REQUIRED EVERY 20 FEET IN HORIZONTAL DUCTS IN | | | ACCORDANCE WITH FBCM 506.3.9 RATHER THAN AT EACH CHANGE | | | IN DIRECTION AS STATED ON PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-11-17 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-11-17 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-11-17 |
Time |
10:38 |
Sent To |
PC |
|
| Notes |
| 2007-11-17 11:08:48 | **************PROVISO***************** | | | ACCESS PANELS FOR CLEAN-OUTS IN HORIZONTAL GREASE DUCTS | | | SHALL BE SPACED NOT MORE THAN 20 FEET APART IN | | | ACCORDANCE WITH FBC,M 506.3.9, NOT ONLY AT CHANGES OF | | | DIRECTION AS INDICATED ON PG M-3. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-08-23 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-08-23 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-08-22 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2007-08-23 08:50:48 | REVIEW #: 2ND | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2005 AND 2006 REVISIONS FBC | | | CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | PREVIOUS REVIEW COMMENTS AS WELL AS THE DESIGNER'S | | | WRITTEN RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | | | 1. OK | | | | | | 2. OK | | | | | | 3. THERE WAS NO WRITTEN RESPONSE TO THIS COMMENT | | | PROVIDED AND NO CHANG SHOWN ON PLANS. PLEASE SHOW HOW | | | THIS ITEM IS TO BE ADDRESSED AND RESUBMIT. | | | | | | 4. THERE IS NO FIRE DAMPER SHOWN ON 20 INCH ROUND DUCT | | | PENETRATING THE RATED TEMPORARY BARRIER. SHOW OPENING | | | PROTECTIVES PER FBC,M 607.5. | | | | | | 5. OK | | | | | | 6. OK | | | | | | 7. THERE WERE NO SPECIFICATIONS SUBMITTED WITH PLANS | | | FOR THIS REVIEW. PLEASE INCLUDE THIS INFORMATION ON THE | | | PLANS. SEE FBC 106.1.1 | | | | | | 8. THERE WERE NO SPECIFICATIONS SUBMITTED WITH PLANS | | | FOR THIS REVIEW. HOWEVER, THE RELEVANT INFORMATION HAS | | | BEEN ADDED TO THE PLANS. THIS COMMENT HAS BEEN | | | ADEQUATELY ADDRESSED. | | | | | | 9. THERE WERE NO SPECIFICATIONS SUBMITTED WITH PLANS | | | FOR THIS REVIEW. NOTE 18 ON PG M-3 CALLS FOR DUCT TO BE | | | SLOPED AT MIN. 1 INCH PER FOOT. IS THIS INTENTIONAL | | | BECAUSE THE HORIZONTAL DUCT MAY BE IN EXCESS OF 75 | | | FEET? THE 9X9 DUCT FOR HOOD #7 WOULD HAVE A RISE OF | | | MORE THAN 4 FEET BEFORE IT REACHES THE LARGER DUCT. | | | PLEASE VERIFY THAT THIS IS EVEN FEASIBLE WITH FIELD | | | CONDITIONS. | | | | | | 10. THERE WERE NO SPECIFICATIONS SUBMITTED WITH PLANS | | | FOR THIS REVIEW. ALSO, THERE ARE NO CLEANOUTS SHOWN ON | | | THE 9X9 GREASE DUCT. PLEASE CORRECT AND RESUBMIT. | | | | | | 11. OK | | | | | | 12. OK | | | | | | 13. PLEASE INDICATE ON PLANS HOW THE ADDED FIRE/SMOKE | | | DAMPERS ARE TO BE ACTUATED IN ACCORDANCE WITH FBC,M | | | 607.5.4.1. | | | | | | 14. DRAWING S-1 ATTACHED TO FRONT OF PLANS: PROVIDE TWO | | | SETS WITH ORIGINAL SEAL AND DATE/SIGNATURE PER FAC | | | 61G15-23.002 | | | | | | NEW COMMENT: THERE HAS BEEN A CHANGE OF CONTRACTOR FORM | | | FILED WITH A NEW PERMIT APPPLICATION FOR JP HURBON, | | | INC. HOWEVER, ONE OF THE SUBCONTRACTORS HAS ALSO BEEN | | | CHANGED ON THE PERMIT APPLICATION FROM BRADLEY HEATING | | | AND AIR CONDITIONING, INC. TO FARMER & IRWIN CORP. AN | | | ADDITIONAL CHANGE OF CONTRACTOR FORM MUST BE FILED TO | | | FACILITATE THIS CHANGE. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-03-05 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-03-05 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-03-02 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2007-03-05 09:41:13 | ----------------DENIED------------------ | | | | | | FLORIDA BUILDING CODE 2004 | | | FLORIDA BUIDLING CODE, MECHANICAL 2004 | | | NFPA 96-01 | | | | | | 1. PG M-1 INFECTION CONTROL PLAN: NOTES CALL FOR | | | EX-AHU-3 TO PROVIDE 100% OUTDOOR AIR FOR AREA BEING | | | RENOVATED. THERE IS NO AHU-3 SHOWN ON THIS PLAN. PLEASE | | | CLARIFY PER FBC 106.1.1. | | | | | | 2. PG A3.0 DETAIL D4 NOTES: REFERS TO PG A13.2 AND | | | A13.5 FOR ADDITIONAL INFO. NO SUCH PAGES WERE INCLUDED | | | IN PLAN. PLEASE CLARIFY PER FBC 106.1.1. | | | | | | 3. PG A5.1 WHAT PROVISIONS ARE BEING MADE TO MAINTAIN | | | FIRE RATED SEPARATION BETWEEN GROUND FLOOR AND FIRST | | | FLOOR WHILE SHAFT IS REMOVED FOR REPLACEMENT OF DUCTS? | | | | | | 4. PG A1.0 AND A3.0 SHOW TEMPORARY CONTAINMENT BARRIER | | | TO BE 1-HOUR RATED. ARE REQUIRED WHERE DUCTS (OUTSIDE | | | AIR FROM EX-AHU-3 AND TEMPORARY EF) PENETRATE THE RATED | | | ASSEMBLY PER FBC,M 607.5. | | | | | | 5. PG M-2 PLAN NOTE #5: NO INFORMATION REGARDING THE | | | REMOVAL OF A THROUGH-WALL FAN COULD BE FOUND IN | | | ARCHITECTURAL DRAWINGS. PLEASE CLARIFY PER FBC | | | 106.1.1. | | | | | | 6. PG M-1 FAN SCHEDULE SHOWS EX-EF-1 MOVING 13,700 CFM. | | | PG M-5 KITCHEN AIR BALANCE SCHEDULE SHOWS EX-EF-1 | | | MOVING 2530 CFM. THESE TWO SCHEDULES DO NOT MATCH. IT | | | ALSO APPEARS THAT THERE IS AN EXTRA 2530 CFM IF EXHAUST | | | IN THE KITCHEN AIR BALANCE SCHEDULE SINCE EX-EF-1 IS | | | ALREADY BEING USED BY THE COMBINED HOODS TO PRODUCE THE | | | 13,700 CFM LISTED AT THE TOP OF THE SCHEDULE. PLEASE | | | CLARIFY PER FBC 106.1.1. | | | | | | 7. PLEASE INDICATE ON PLAN THE THICKNESS OF THE | | | STAINLESS STEEL EXHAUST DUCTS TO SHOW COMPLIANCE WITH | | | FBC,M 506.3.1.1. | | | | | | 8. PG X1.1 PLEASE REFERENCE SMACNA-95 HVAC DUCT | | | CONSTRUCTION STANDARDS - METAL AND FLEXIBLE TO SHOW | | | COMPLIANCE WITH FBC,M 603.3. | | | | | | 9. GREASE DUCTS TO BE SLOPED TOWARD THE HOOD AT NOT | | | LESS THAN 1/4 UNIT VERTICAL IN 12 UNITS HORIZONTAL PER | | | FBC,M 506.3.7. | | | | | | 10. THERE ARE NO CLEANOUTS SHOWN ON HORIZONTAL GREASE | | | DUCTS IN KITCHEN AREA. CLEANOUTS LOCATED ON HORIZONTAL | | | DUCTS SHALL BE SPACED NOT MORE THAN 20' APART PER FBC,M | | | 506.3.9. | | | | | | 11. GREASE DUCTS FOR TYPE I HOODS SHALL NOT BE | | | INTERCONNECTED UNLESS THEY MEET ALL THE REQUIREMENTS OF | | | FBC,M 506.3.5. THIS DESIGN CALLS FOR THE GREASE DUCTS | | | FROM HOODS 1,2 AND 7 TO INTERCONNECT AFTER ENTERING THE | | | RATED SHAFT ASSEMBLY. THIS DOES NOT COMPLY WITH | | | REQUIREMENT #3 OF THIS SECTION. | | | | | | 12. DUCT ENCLOSURE FOR GREASE DUCTS SHALL SERVE ONLY A | | | SINGLE GREASE EXHAUST DUCT SYSTEM AND SHALL MEET THE | | | MINIMUM AND MAXIMUM CLEARANCE REQUIREMENTS OF FBC,M | | | 506.3.10. MAKE-UP AIR DUCTS MAY NOT USE THE SAME SHAFT | | | ENCLOSURE AS THE GREASE DUCT. | | | | | | 13. DUCTS PENETRATING A SHAFT ENCLOSURE SHALL BE | | | PROTECTED WITH APPROVED FIRE AND SMOKE DAMPERS | | | INSTALLED IN ACCORDANCE WITH THEIR LISTING PER FBC,M | | | 607.5.5.1. THIS APPLIES ONLY TO THE MAKE-UP AIR DUCTS. | | | | | | 14. DRAWING SK-1 SHOWS METAL STRAPS OVER TOP OF FAN | | | HOUSINGS FOR THE PURPOSE OF ROOF ATTACHMENT. THESE | | | STRAPS SHOULD NOT HAVE TO BE REMOVED FOR EQUIPMENT | | | SERVICE PANEL ACCESS PER FBC,M 306.1. | | | | | | NOTE: A SEPARATE PERMIT WILL BE NEEDED FOR THE REQUIRED | | | MECHANICAL HOOD SUPPRESSION SYSTEM. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE FEEL FREE TO CONTACT | | | ME. | | | | | | RONALD J REGUEIRO | | | 561-805-6719 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-11-19 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-11-19 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
LFRANCO |
Date |
2007-11-19 |
Time |
15:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-10-29 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2007-10-29 |
Time |
18:21 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2007-10-29 |
Time |
18:19 |
Sent To |
|
|
| Notes |
| 2007-10-29 18:21:11 | PLANNING AND ZONING:**** FAILED **** - COMMENT IS | | | STILL OUTSTANDING, NO BUILDING PERMIT WILL BE ACCEPTED | | | OR APPROVED (WITH THE EXCEPTION OF LIFE SAFETY BLDG. | | | PERMITS) UNTIL COMMENT IS ADDRESSED. | | | | | | 1. PLEASE RESPOND TO COMMENTS IN WRITING. | | | | | | 2. PURSUANT TO A LETTER DATED JULY 11, 2007 (ATTACHED | | | HEREIN) , SENT BY THE DEPUTY PLANNING DIRECTOR, ANGELLA | | | JONES-VANN TO REBECCA K. BOYAJIAN, ESQ. HOLLAND & | | | KNIGHT, LLP, ON BEHALF OF TENENT ST. MARY'S, NO PERMIT | | | WILL BE ISSUED WITH SOME EXCEPTIONS UNTIL THE FOLLOWING | | | REPLAT CONDITIONS ARE MADE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT THE DEPUTY | | | PLANNING DIRECTOR, ANGELLA JONES-VANN AT THE NUMBER | | | BELOW. | | | | | | AJV/LMF | | | | | | | | | JULY 11, 2007 | | | | | | | | | REBECCA K. BOYAJIAN, ESQ. | | | HOLLAND & KNIGHT, LLP | | | 222 LAKEVIEW AVENUE, SUITE 1000 | | | WEST PALM BEACH, FLORIDA 33401 | | | | | | | | | RE: ST. MARY'S HOSPITAL COMMUNITY SERVICE PLANNED | | | DEVELOPMENT (CSPD) | | | | | | | | | DEAR MS. BOYAJIAN: | | | | | | IT WAS BROUGHT TO THE ATTENTION OF THE PLANNING AND | | | ZONING DEPARTMENT THAT ST. MARY TENET ILLEGALLY SOLD A | | | PORTION OF THEIR PROPERTY WITHOUT GOING THROUGH THE | | | CITY?S SUBDIVISION PROCESS.THIS PORTION WAS LATER | | | UNIFIED TO THE HANLEY CENTER CAMPUS? PROPERTY, LOCATED | | | IMMEDIATELY WEST OF THE ST. MARY?S MEDICAL CENTER.AS | | | A RESULT, ANY DEVELOPMENT ORDERS, TO INCLUDE BUILDING | | | PERMITS WITH THE EXCEPTION OF PERMITS FOR LIFE SAFETY | | | SYSTEMS (I.E.: FIRE EXTINGUISHERS, FIRE SPRINKLERS, | | | FIRE DETECTION AND ALARM SYSTEMS, EXIT SYSTEMS | | | INCLUDING MARKING AND HARDWARE, ILLUMINATION SYSTEMS | | | INCLUDING NORMAL AND EMERGENCY LIGHTING AND | | | GENERATORS), FOR THE ST. MARY?S AND THE HANLEY CENTER | | | SITES, WILL NOT BE ISSUED UNTIL THE FOLLOWING HAS BEEN | | | COMPLETED: | | | | | | 1. A REPLAT OF THE ST. MARY?S MEDICAL CENTER PARCEL | | | THROUGH THE CITY?S MINOR SUBDIVISION PROCESS; AND 2. A | | | MAJOR AMENDMENT TO THE ST. MARY?S MEDICAL CENTER CSPD | | | TO CHANGE THE EXISTING BOUNDARY OF THE PLANNED | | | DEVELOPMENT.PLEASE NOTE THAT THE MAJOR AMENDMENT WILL | | | REQUIRE APPROVAL BY THE CITY COMMISSION. | | | | | | IF YOU HAVE ANY OTHER QUERIES, PLEASE DO NOT HESITATE | | | TO CONTACT ME AT (561) 822-1435. | | | | | | SINCERELY, | | | ANGELLA VANN, AICP | | | DEPUTY PLANNING DIRECTOR | | | | | | C: ERIC SCHNEIDER, PRINCIPAL PLANNER | | | NEIL K. MELICK, CONSTRUCTION SERVICES DIRECTOR NANCY | | | URCHECK, DEPUTY CITY ATTORNEY | | | G. SCOTT MANIS, FACHE, CHIEF OPERATING OFFICER | | | CHARLES W. MILLAR, DEVELOPMENT PLANNER |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-09-07 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2007-09-07 |
Time |
18:17 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2007-09-07 18:17:11 | PLANNING AND ZONING:**** FAILED **** | | | | | | 1. PLEASE RESPOND TO COMMENTS IN WRITING. | | | | | | 2. PURSUANT TO A LETTER DATED JULY 11, 2007 (ATTACHED | | | HEREIN) , SENT BY THE DEPUTY PLANNING DIRECTOR, ANGELLA | | | JONES-VANN TO REBECCA K. BOYAJIAN, ESQ. HOLLAND & | | | KNIGHT, LLP, ON BEHALF OF TENENT ST. MARY'S, NO PERMIT | | | WILL BE ISSUED WITH SOME EXCEPTIONS UNTIL THE FOLLOWING | | | REPLAT CONDITIONS ARE MADE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT THE DEPUTY | | | PLANNING DIRECTOR, ANGELLA JONES-VANN AT THE NUMBER | | | BELOW. | | | | | | AJV/LMF | | | | | | | | | JULY 11, 2007 | | | | | | | | | REBECCA K. BOYAJIAN, ESQ. | | | HOLLAND & KNIGHT, LLP | | | 222 LAKEVIEW AVENUE, SUITE 1000 | | | WEST PALM BEACH, FLORIDA 33401 | | | | | | | | | RE: ST. MARY'S HOSPITAL COMMUNITY SERVICE PLANNED | | | DEVELOPMENT (CSPD) | | | | | | | | | DEAR MS. BOYAJIAN: | | | | | | IT WAS BROUGHT TO THE ATTENTION OF THE PLANNING AND | | | ZONING DEPARTMENT THAT ST. MARY TENET ILLEGALLY SOLD A | | | PORTION OF THEIR PROPERTY WITHOUT GOING THROUGH THE | | | CITY?S SUBDIVISION PROCESS.THIS PORTION WAS LATER | | | UNIFIED TO THE HANLEY CENTER CAMPUS? PROPERTY, LOCATED | | | IMMEDIATELY WEST OF THE ST. MARY?S MEDICAL CENTER.AS | | | A RESULT, ANY DEVELOPMENT ORDERS, TO INCLUDE BUILDING | | | PERMITS WITH THE EXCEPTION OF PERMITS FOR LIFE SAFETY | | | SYSTEMS (I.E.: FIRE EXTINGUISHERS, FIRE SPRINKLERS, | | | FIRE DETECTION AND ALARM SYSTEMS, EXIT SYSTEMS | | | INCLUDING MARKING AND HARDWARE, ILLUMINATION SYSTEMS | | | INCLUDING NORMAL AND EMERGENCY LIGHTING AND | | | GENERATORS), FOR THE ST. MARY?S AND THE HANLEY CENTER | | | SITES, WILL NOT BE ISSUED UNTIL THE FOLLOWING HAS BEEN | | | COMPLETED: | | | | | | 1. A REPLAT OF THE ST. MARY?S MEDICAL CENTER PARCEL | | | THROUGH THE CITY?S MINOR SUBDIVISION PROCESS; AND 2. A | | | MAJOR AMENDMENT TO THE ST. MARY?S MEDICAL CENTER CSPD | | | TO CHANGE THE EXISTING BOUNDARY OF THE PLANNED | | | DEVELOPMENT.PLEASE NOTE THAT THE MAJOR AMENDMENT WILL | | | REQUIRE APPROVAL BY THE CITY COMMISSION. | | | | | | IF YOU HAVE ANY OTHER QUERIES, PLEASE DO NOT HESITATE | | | TO CONTACT ME AT (561) 822-1435. | | | | | | SINCERELY, | | | ANGELLA VANN, AICP | | | DEPUTY PLANNING DIRECTOR | | | | | | C: ERIC SCHNEIDER, PRINCIPAL PLANNER | | | NEIL K. MELICK, CONSTRUCTION SERVICES DIRECTOR NANCY | | | URCHECK, DEPUTY CITY ATTORNEY | | | G. SCOTT MANIS, FACHE, CHIEF OPERATING OFFICER | | | CHARLES W. MILLAR, DEVELOPMENT PLANNER |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |