| Plan Review Stops For Permit 07011083 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2007-01-29 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2007-01-29 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2007-01-29 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2007-01-29 14:23:35 | PERMIT HAS BEEN ATTACHED TO THE CORRECT UNIT # | | | 0001,UNDER PCN = 74434403010004860 | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-09-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-09-12 |
Time |
19:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-09-12 |
Time |
19:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2007-08-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-31 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-31 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2007-08-31 14:39:15 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | | FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.)TWO SETS REQUIRED.ONE SET IS A PHOTOCOPY. | | | ENGINEERING IS TO BE ORIGINAL, FS471. | | | | | | 2.)SHEET 4 STILL SHOWS SCUPPERS ON THE STRUCTURAL | | | DETAIL.PLEASE CHECK ALL SHEETS AND AS THE ENGINEER | | | HAS DETERMINED THAT SCUPPERS ARE NOT REQUIRED, REMOVE | | | REFERENCES FROM THE PLAN. | | | | | | 3.)APPLICATION DESCRIPTION IS NOT CONSISTENT WITH THE | | | PLAN.APPLICATION STATES THAT INSULATION WILL BE | | | INSTALLED.WHERE?WHAT TYPE?PROVIDE A DETAIL/PLAN. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-08-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-29 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-29 |
Time |
09:29 |
Sent To |
P |
|
| Notes |
| 2007-08-29 09:35:58 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.)THE ENGINEER'S LETTER HAS BEEN ALTERED (FROM | | | SCUPPERS "WILL BE" ADDED TO "MAY BE").SCUPPERS ARE A | | | PART OF THE ENGINEER'S DESIGN AND THE LETTER CAN ONLY | | | BE CHANGED BY THE ENGINEER.EITHER SUBMIT A LETTER | | | WHICH HAS NOT BEEN ALTERED OR HAVE THE ENGINEER REVISE | | | THE LETTER AND PLAN. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-03-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-03-19 |
Time |
18:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-03-19 |
Time |
18:07 |
Sent To |
|
|
| Notes |
| 2007-03-19 18:36:25 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBEXISTING BUILDING CODE 2004 | | | FBC R RESIDENTIAL 2004 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | | | | 1.)SE FBC R 301.1, "BUILDINGS AND STRUCTURES, AND ALL | | | PARTS THEREOF, SHALL BE CONSTRUCTED TO SAFELY SUPPORT | | | ALL LOADS . . . INCLUDING WIND LOADS."THE DETAIL | | | PROVIDED IS NOT STRUCTURALLY CONTINUOUS; IT DIVIDES THE | | | WALL INTO TWO PARTS AND DOES NOT ADDRESS HOW THE NEW | | | PARAPET WILL WITHSTAND WIND LOADS.THE DETAIL IS NOT | | | CLEAR; STATES "SPT66 STRAPS AT TOP & BOTTOM OF EACH | | | STUD", AND "STRAPS AT EA STUD TOP & BOTTOM OVER & UNDER | | | PLATES."WHEN RESUBMITTING, INCLUDE THE STRAPS IN THE | | | STRUCTURAL DETAIL. | | | | | | 2.)SPT66 IS FOR 6" FRAMING.2X4 FRAMING IS SHOWN ON | | | YOUR DETAIL.SPT66 DOES NOT PROPERLY ADDRESS ITEM #1. | | | HOWEVER, WHEN REDESIGNING THE WALL DETAIL, PLEASE | | | CONFIRM THAT THE CONNECTORS SPECIFIED ARE THE CORRECT | | | SIZE FOR FRAMING SPECIFIED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-02-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-02-08 |
Time |
17:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-02-08 |
Time |
17:25 |
Sent To |
P |
|
| Notes |
| 2007-02-08 17:38:51 | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | 1.)PROVIDE STRUCTURAL PLANS PREPARED BY AN ENGINEER | | | OR ARCHITECT. | | | | | | 2.)PROVIDE WIND DESIGN CRITERIA, FBC1603.1.4. | | | | | | 3.)PROVIDE A DRAINAGE PLAN.PROVIDE CALCULATIONS. | | | FBC 15. | | | | | | 4.)PROVIDE INFORMATION AS TO HOW THE ROOF WILL BE | | | PITCHED TO PROPERLY DRAIN. | | | | | | 5.)PROVIDE INFORMATION IN REGARDS TO THE EXISTING | | | ROOF (DESIGN LIVE LOAD).SHOW THAT THE EXISTING ROOF | | | CAN ACCOMODATE THE ADDITIONAL LIVE LOAD OF RAINWATER. | | | | | | 6.)A NOTICE OF COMMENCEMENT WILL BE REQUIRED PRIOR TO | | | PERMIT PICKUP, FS713.13. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-09-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-07 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-07 |
Time |
09:34 |
Sent To |
B |
|
| Notes |
| 2007-09-07 09:34:35 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-08-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-24 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-24 |
Time |
14:38 |
Sent To |
B |
|
| Notes |
| 2007-08-24 14:38:15 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-03-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-02 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-02 |
Time |
11:24 |
Sent To |
P |
|
| Notes |
| 2007-03-02 11:24:52 | TO "P" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-02-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-02-08 |
Time |
17:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-01-29 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2007-01-29 09:08:15 | TO "MISC" BOX#1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2007-03-13 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-03-13 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-03-13 |
Time |
09:21 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-02-09 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-02-09 |
Time |
16:03 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-02-09 |
Time |
16:03 |
Sent To |
PC |
|
| Notes |
| 2007-02-09 16:37:44 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | | | | THE FOLLOWING INFORMATION IS REQUIRED FOR PLUMBING | | | PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. MUST PROVIDE A ROOF PLAN THAT INDICATES HOW THE ROOF | | | WILL BE PITCHED TO PROPERLY DRAIN, AND INDICATE THE | | | FOLLOWING INFORMATION PER THE FOLLOWING CODE | | | REFERENCES. | | | A} DETAIL OF ROOF INDICATING SQUARE FOOTAGE OF ROOF | | | AND VERTICAL WALLS (PARAPHET) DRAINING TO DOWNSPOUTS | | | AND SCUPPERS TO VERIFY COMPLIANCE WITH FBC-2004 | | | PLUMBING, SECTIONS 1106. | | | B} VERTICAL CONDUCTORS AND LEADERS, PER FBC-2004 | | | PLUMBING, SECTION 1106.2. | | | C} VERTICAL WALLS, PER FBC-2004 PLUMBING, SECTION | | | 1106.4. | | | D} SCUPPERS, (PROVIDE DETAIL PER FBC-2004 BUILDING, | | | SECTIONS 1503.4.2 AND 1503.4.3 ) SIZE PER FBC-2004 | | | PLUMBING, TABLE 1106.7. | | | E} SECONDARY (EMERGENCY) ROOF DRAINS, PER FBC-2004 | | | PLUMBING, SECTION 1107. | | | A) SECONDARY DRAINAGE REQUIRED, PER FBC-2004 | | | PLUMBING, SECTION 1107.1. | | | B) SEPERATE SYSTEMS REQUIRED, PER FBC-2004 PLUMBING, | | | SECTION 1107.2. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|