Plan Review Details - Permit 07011004
Plan Review Stops For Permit 07011004
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-08-29 Cont ID  
Sent By rmcdouga Date 2007-08-29 Time 18:49 Rev Time 0.00
Received By rmcdouga Date 2007-08-29 Time 18:19 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-05-24 Cont ID  
Sent By rmcdouga Date 2007-05-24 Time 10:15 Rev Time 0.00
Received By rmcdouga Date 2007-05-23 Time 16:51 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-03-21 Cont ID  
Sent By rmcdouga Date 2007-03-21 Time 17:14 Rev Time 0.00
Received By rmcdouga Date 2007-03-21 Time 06:59 Sent To  
Notes
2007-03-21 17:23:35DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) DETAIL 1/A4 SITES THE WRONG CODE SECTION FOR THE
 FIREBLOCKING FOR THE CONCEALED SPACES OF THE STAIRS.
 THE CORRECT SECTION IS FBC R602.1.2.
  
 4) THE FIREBLOCKING MATERIAL IS REQUIRED TO COMPLY WITH
 FBC R602.1.2.1. THE 5/8" PLYWOOD SPECIFIED IN THE NOTES
 FOR DETAIL 1/A4 DOES NOT COMPLY.
  
 5) R311.5.8.3 REQUIRES CIRCULAR STAIRS TO HAVE A
 MINIMUM TREAD WIDTH OF 9 INCHES WITH 1 INCH OF NOSING.
 DETAIL 1/A4 DOES NOT COMPLY.
  
 6) SHOW COMPLIANCE WITH R806.1 VENTILATION REQUIRED.
 ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE
 CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF
 RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE
 SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE
 ENTRANCE OF RAIN. VENTILATING OPENINGS SHALL BE
 PROVIDED WITH CORROSION-RESISTANT WIRE MESH, WIT H 1 /
 8 INCH (3.2 MM) MINIMUM TO ? INCH (6.4 MM) MAXIMUM
 OPENINGS.
  
 7) SHOW COMPLIANCE WITH R806.2 MINIMUM AREA.
 THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LESS
 THAN 1 TO 150 OF THE AREA OF THE SPACE VENTILATED
 EXCEPT THAT THE TOTAL AREA IS PERMITTED TO BE REDUCED
 TO 1 TO 300, PROVIDED AT LEAST 50 PERCENT AND NOT MORE
 THAN 80 PERCENT OF THE REQUIRED VENTILATING AREA IS
 PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF
 THE SPACE TO BE VENTILATED AT LEAST 3 FEET (914 MM)
 ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE OF THE
 REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS.
 AS AN ALTERNATIVE, THE NET FREE CROSS-VENTILATION AREA
 MAY BE REDUCED TO 1 TO 300 WHEN A VAPOR BARRIER HAVING
 A TRANSMISSION RATE NOT EXCEEDING 1 PERM (57.4 MG/S ? M
 2 ? PA) IS INSTALLED ON THE WARM SIDE OF THE CEILING.
  
 8)ROOF SHEATHING IS REQUIRED TO BE IN ACCORDANCE WITH
 SECTION R803.2.3.1 OF 2006 REVISIONS TO 2004 FBC
 RESIDENTIAL CODE. WOOD STRUCTURAL PANEL SHEATHING SHALL
 BE FASTENED TO ROOF FRAMING WITH 8D RING-SHANK NAILS AT
 6 INCHES ON CENTER AT EDGES AND 6 INCHES ON CENTER AT
 INTERMEDIATE FRAMING. SPACING OF RING-SHANK FASTENERS
 SHALL BE 4 INCHES ON CENTER IN NAILING ZONE 3 FOR 130
 MPH OR GREATER DESIGN WIND SPEEDS IN ACCORDANCE WITH
 FIGURE R803.2.3.1.
  
 9) ON A5 THE ROOF TILE FASTENING NOTE SPECIFIES (2) #9
 SCREWS. DID YOU INTEND TO SPECIFY #8 SCREWS AS LISTED
 IN THE ROOF TILE PRODUCT APPROVAL?I DO NOT BELIEVE #9
 SCREWS ARE AVAILABLE.
  
 10)WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 11)SPECIFY THE FASTENING OPTION THAT WILL BE USED TO
 INSTALL THE CONCRETE ROOF TILES. CIRCLE THE APPROPRIATE
 ITEM ON THE NOA.
  
 12) THE NOA SUBMITTED FOR THE HANSEN ROOF TILE HAS BEEN
 CLOSED BY MIAMI-DADE PRODUCT CONTROL. THE CURRENT NOA
 FOR THE HANSEN TILE IS 02-0916.09.
  
 13) SUBMIT PRODUCT APPROVALS FOR STRUCTURAL WINDOW
 MULLIONS.
  
 14) SUBMIT PRODUCT APPROVALS FOR IMPACT RATED FRENCH
 DOORS WITHOUT SIDELITES.
  
 15) SUBMIT PRODUCT APPROVALS FOR THE BITHUTHENE WATER
 PROOF MEMBRANE THAT WILL BE INSTALLED ON THE DECKS.
  
 16) SUBMIT PRODUCT APPROVALS FOR THE FRONT ENTRY DOOR.
  
 17) THE PLANS SPECIFY A HOLLOW METAL RAISED PANEL DOOR
 FOR DOOR #106. PRODUCT APPROVALS WERE SUBMITTED FOR A
 RAISED PANEL FIBERGLASS DOOR, BUT NOT A METAL DOOR.
 PLEASE CO-ORDINATE THE PLANS WITH THE PRODUCT
 APPROVALS.
  
 18)THE PRODUCT APPROVAL FOR THE PGT WINDOWS HAS BEEN
 REVISED. THE FL NUMBER IS FL 239-R7 AND THE NEW NOA IS
 #05-1018.01.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-03-07 Cont ID  
Sent By btrobaug Date 2008-03-07 Time 16:48 Rev Time 0.00
Received By btrobaug Date 2008-03-07 Time 11:31 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-01-29 Cont ID  
Sent By btrobaug Date 2007-01-29 Time 07:33 Rev Time 0.50
Received By btrobaug Date 2007-01-24 Time 16:27 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2008-11-26 Cont ID  
Sent By adarroug Date 2008-11-26 Time 16:53 Rev Time 0.00
Received By adarroug Date 2008-11-26 Time 16:53 Sent To L
Notes
2008-11-26 16:54:11TO "Z" BOX/RESUB--FOR LANDSCAPING REVIEW

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2008-11-20 Cont ID  
Sent By adarroug Date 2008-11-20 Time 16:43 Rev Time 0.00
Received By adarroug Date 2008-11-20 Time 16:43 Sent To Z
Notes
2008-11-20 16:44:13TO "Z" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2008-03-10 Cont ID  
Sent By adarroug Date 2008-03-10 Time 12:00 Rev Time 0.00
Received By adarroug Date 2008-03-10 Time 12:00 Sent To M
Notes
2008-03-10 12:00:34TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2008-03-06 Cont ID  
Sent By adarroug Date 2008-03-06 Time 12:09 Rev Time 0.00
Received By adarroug Date 2008-03-06 Time 12:09 Sent To E
Notes
2008-03-06 12:09:49TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-02-29 Cont ID  
Sent By adarroug Date 2008-02-29 Time 16:43 Rev Time 0.00
Received By adarroug Date 2008-02-29 Time 16:43 Sent To M
Notes
2008-02-29 16:43:32TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-08-27 Cont ID  
Sent By adarroug Date 2007-08-27 Time 09:56 Rev Time 0.00
Received By adarroug Date 2007-08-27 Time 09:56 Sent To Z
Notes
2007-08-27 09:56:22TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-05-09 Cont ID  
Sent By shill Date 2007-05-09 Time 16:54 Rev Time 0.00
Received By shill Date 2007-05-09 Time 16:54 Sent To B
Notes
2007-05-09 16:54:57TO "RMCDOUGAL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-04-17 Cont ID  
Sent By adarroug Date 2007-04-17 Time 14:28 Rev Time 0.00
Received By adarroug Date 2007-04-17 Time 14:28 Sent To Z
Notes
2007-04-17 14:28:33TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status   Date 2007-08-27 Cont ID  
Sent By rmcdouga Date 2007-03-21 Time 17:14 Rev Time 0.00
Received By adarroug Date 2007-01-23 Time 09:38 Sent To  
Notes
2007-01-23 09:38:57TO "SFR" "Z"

Review Stop L LANDSCAPING
Rev No 2 Status P Date 2008-12-02 Cont ID  
Sent By rkussner Date 2008-12-02 Time 17:59 Rev Time 0.00
Received By rkussner Date 2008-12-02 Time 17:59 Sent To PC
Notes
2008-12-02 18:03:30***LANDSCAPE PLAN APPROVED WITH PROVISO***
  
 THERE WAS NO INDICATION ON PLAN IF THERE ARE OVERHEAD
 POWERLINES IN THE 5 FOOT UTILITY EASEMENT ADJACENT TO
 THE STREET. IF THERE ARE OVERHEAD LINES, THE (2) TRIPLE
 FOXTAIL PALMS AND THE (1) ROYAL PALM CLOSEST TO THE
 STREET CANNOT BE PLANTED. THE RULES SETFORTH BY FPL'S
 "PLANT THE RIGHT TREE IN THE RIGHT PLACE" MUST APPLY.
 ---RAK

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2008-11-21 Cont ID  
Sent By rkussner Date 2008-11-21 Time 11:51 Rev Time 0.00
Received By rkussner Date 2008-11-21 Time 08:38 Sent To PC
Notes
2008-11-21 12:02:02***LANDSCAPE REVIEW FAILED***
  
 1. PROVIDE THE LOCATION ON THE LANDSCAPE PLAN OF
 OVERHEAD POWER LINES, UTILITIES, EASEMENTS AND ANYTHING
 ELSE THAT MAY IMPACT THE PROPOSED LANDSCAPING. IF THERE
 ARE OVEHEAD POWER LINES, YOU SHALL COMPLY WITH FPL'S
 "PLANT THE RIGHT TREE IN THE RIGHT PLACE" GUIDELINES
 THAT DICTATE WHICH TREES CAN BE PLANTED NEAR OR
 ADJACENT TO OVERHEAD POWER LINES.
  
 2. IF THIS PROPERTY DOES NOT EXTEND TO THE PAVED ROAD,
 SOD AND IRRIGATION SHALL BE REQUIRED IN THE
 RIGHT-OF-WAY BETWEEN THE PROPERTY LINE AND PAVED ROAD.
  
  
 IF YOU HAVE ANY QUESTIONS REGARDING THESE LANDSCAPE
 COMMENTS, PLEASE CONTACT ROBERT KUSSNER @ (561)
 822-1462.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2008-03-10 Cont ID  
Sent By tgordon Date 2008-03-10 Time 15:53 Rev Time 0.45
Received By tgordon Date 2008-03-10 Time 15:53 Sent To  
Notes
2008-03-10 15:54:01REVISION TO MECH. PLANS PAGES M-1 AND M-2.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2008-03-04 Cont ID  
Sent By tgordon Date 2008-03-04 Time 08:01 Rev Time 0.35
Received By tgordon Date 2008-03-04 Time 08:01 Sent To  
Notes
2008-03-04 08:08:45PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 REVISION TO MECHANICAL PLANS
 *** DENIED ***
 1) MECHANICAL PLAN ON FILE HAS BEEN SIGNED AND SEALED
 BY AN ARCHITECT (JONATHAN C. MOORE) SO ONLY HE CAN MAKE
 REVISIONS TO THEM. PLEASE HAVE ARCHITECT ON RECORD SIGN
 AND SEAL PLANS OR SUBMIT A LETTER FROM HIM REMOVING
 HIMSELF FROM THE PROJECT.
  
 2) SEE YELLOW HIGH LIGHT ON PLAN SHOW TWO SUPPLY AIR
 DUCTS THAT NEED TO BE SIZED, PER 2004 WPB AMEND.
 106.3.5.4 (10).
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2007-01-24 Cont ID  
Sent By tgordon Date 2007-01-24 Time 16:22 Rev Time 0.30
Received By tgordon Date 2007-01-24 Time 16:22 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2007-01-29 Cont ID  
Sent By jleech Date 2007-01-29 Time 07:54 Rev Time 0.00
Received By jleech Date 2007-01-29 Time 07:37 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2007-08-29 Cont ID  
Sent By choops Date 2007-08-29 Time 17:41 Rev Time 0.00
Received By choops Date 2007-08-29 Time 17:41 Sent To B
Notes
2007-08-29 17:42:54***APPROVED******REVISION - CHANGED FINISHED FLOOR
 ELEVATION.***
  
 PROVISO:BUILDING HEIGHT NOT TO EXCEED 30'
  
  
 SENT TO RMC

Review Stop Z ZONING
Rev No 2 Status P Date 2007-05-08 Cont ID  
Sent By choops Date 2007-05-08 Time 07:56 Rev Time 0.00
Received By choops Date 2007-05-08 Time 07:56 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2007-01-23 Cont ID  
Sent By mmclean Date 2007-01-23 Time 18:55 Rev Time 0.00
Received By mmclean Date 2007-01-23 Time 18:55 Sent To E
Notes
2007-01-23 18:56:48DENIED,
 1. PLEASE PROVIDE THE DIMENSION OF THE PROPOSED
 DRIVEWAY (WIDTH & LENGTH).
 2. PLEASE INDICATE THE TYPE OF MATERIAL THAT WILL BE
 USED FOR PROPOSED DRIVEWAY.
 MUST MAINTAIN 1000SQ FT OR 75% OF LANDSCAPE, WHICHEVER
 IS LESS WITHIN THE FIRST 25FT FRONT SETBACK.
  
 NOTE: THE PROPOSED A/C EQUIPMENT SHALL NOT BE CLOSER
 THAN 6FT FROM SIDE PROPERTY LINE (EAST SIDE).
  
 NOTE: THE PROPOSED POOL/SPA/DECK SHALL BE PERMITTED
 SEPARATELY.
  
 NOTE: THE PROPOSED FENCE/GATE SHALL BE PERMITTED
 SEPARATELY.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720