Plan Review Details - Permit 07010911
| Plan Review Stops For Permit 07010911 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-03-26 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-03-26 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-03-26 |
Time |
18:03 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-03-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-03 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-03 |
Time |
15:46 |
Sent To |
Z |
|
| Notes |
| 2007-03-03 15:47:56 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-01-30 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2007-01-30 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2007-01-20 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2007-01-20 13:49:13 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-03-29 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-03-29 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-03-29 |
Time |
14:39 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-03-16 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-03-16 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-03-16 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2007-03-16 14:00:20 | ***FAILED*** | | | | | | 1) PER SECTION 94-302(C)(2) OF THE CITY'S ZONING AND | | | LAND DEVELOPMENT REGULATIONS, BARBED WIRE IS PERMITTED; | | | HOWEVER, THE STRANDS SHALL MOUNTED VERTICALLY OR AT AN | | | ANGLE PROJECTING INTERIOR TO THE PROPERTY AND MUST NOT | | | ENCROACH BEYOND THE PROPERTY LINE.PLEASE INDICATE ON | | | THE PLAN HOW THIS WILL BE ADDRESSED. | | | | | | 2) PER SECTION 94-305(E), "AT ANY ROAD INTERSECTIONS, | | | VISIBILITY SHALL NOT BE OBSCURED BY THE CONSTRUCTION, | | | PLACEMENT, OR MAINTENANCE OF A STRUCTURE WALL, SIGN, | | | FENCE, BERM, PLANT MATERIAL, SHRUBS, OR ANY SIMILAR | | | ITEM BETWEEN 18 INCHES OR EIGHT FEET IN HEIGHT WITHIN A | | | TRIANGLE BEGINNING AT THE POINT WHERE PROPERTY LINES | | | MEET AT THE CORNER, THEN 20 FEET ALONG THE FRONT | | | PROPERTY LINE, THENCE DIAGONALLY TO A POINT ALONG THE | | | SIDE PROPERTY LINE 20 FEET FROM THE POINT OF BEGINNING, | | | AND THENCE TO THE POINT OF BEGINNING. IN THE EVENT THE | | | CORNER OF AN INTERSECTION IS ROUNDED, THE MEASUREMENT | | | SHALL BEGIN AT THE POINT THE PROPERTY LINES WOULD MEET | | | WITHOUT ROUNDING." | | | | | | 3) FENCES SHALL NOT ENCROACH INTO DRAINAGE EASEMENTS. | | | THE FENCE SHALL NOT CROSS THE DRAINAGE EASEMENT ALONG | | | WITT STREET. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-01-30 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2007-01-30 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2007-01-30 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2007-01-30 10:40:28 | DENIED, | | | 1. THE SUBMITTED SITEPLAN IS NOT LEDGERABLE FOR | | | REVIEW. | | | 2. SITEPLAN DOES NOT SHOW CLEARLY THE BOUNDARY OF THE | | | PROPERTY TO IDENTIFY THE LOCATION OF THE PROPOSED FENCE | | | AND MARK CLEARLY THE 20FT VISIBILITY TRIANGLE ON BOTH N | | | FLORIDA MANGO AND WORTHINGTON RD, WORTHINGTON RD AND | | | WITT ST. | | | | | | NOTE: AT ANY ROAD INTERSECTION, VISIBILITY SHALL NOT BE | | | OBSCURED BY THE CONSTRUCTION, PLACEMENT, OR | | | MAINTENANCE | | | OF A STRUCTURE WALL, SIGN, FENCE, BERM PLANT MATERIAL, | | | SHRUBS, OR ANY SIMILAR ITEM BETWEEN 18 INCHES OR EIGHT | | | POINT | | | WHERE PROPERTY LINES MEET AT THE CORNER, THEN 20FT | | | ALONG THE FRONT PROPERTY LINE 20FT FROM THE POINT OF | | | BEGINING, AND | | | THENCE TO THE POINT OF BEGINING.IN THE EVENT THE | | | CORNER OF AN INTERSECTION IS ROUNDED, THE MEASUREMENT | | | SHALL BEGIN AT | | | THE POINT THE PROPERTY LINES WOULD MEET WITHOUT | | | ROUNDING. (SEE FIGURE X-1). | | | | | | 3. PLEASE SUBMIT TWO COPIES OF CURRENT SITEPLANS OR | | | SURVEYS THAT SHOWS THE LOCATION OF THE PROPOSED FENCE, | | | MEETING THE 20FT VISIBILITY TRIANGLE. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
|