| Plan Review Stops For Permit 07010880 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-03-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-03-14 |
Time |
06:37 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-03-14 |
Time |
05:58 |
Sent To |
PC |
|
| Notes |
| 2007-03-14 06:24:39 | BUILDING PROVISO: | | | TO BE IN PLACE AT C.O.: | | | | | | 1) 424.2.17.1 OUTDOOR SWIMMING POOLS. | | | OUTDOOR SWIMMING POOLS SHALL BE PROVIDED | | | WITH A BARRIER COMPLYING WITH | | | 424.2.17.1.1 THROUGH 424.2.17.1.14. | | | | | | 424.2.17.1.5 CHILD SAFETY BARRIER | | | ASTM D5034 100 LB TENSILE STRNGTH | | | ASTM D3787 150 LB BALL BURST STRENGTH | | | | | | 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED. | | | SPAS AND HEATED SWIMMING POOLS SHALL BE | | | EQUIPPED WITH A COVER DESIGNED TO | | | MINIMIZE HEAT LOSS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-02-12 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-02-12 |
Time |
07:43 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-02-12 |
Time |
06:38 |
Sent To |
PC |
|
| Notes |
| 2007-02-12 07:22:59 | BUILDING PLAN REVIEW | | | PERMIT:07010880 | | | ADD:7240WINDING BAY LN | | | CONT: AAACUSTOM POOLS. INC. | | | TEL: (561)753-3366 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 1ST | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) ALL PLANS SUBMITTED AFTER OCTOBER, 1, | | | 2004 SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE. SEE SHEET #3 | | | | | | 3)INDICATE THE SQUARE FOOTAGE OF THE DECK AREA ON THE | | | DRAWINGS | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-04-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-04-04 |
Time |
08:55 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-04-04 |
Time |
07:42 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-03-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-03-27 |
Time |
13:10 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2007-03-27 |
Time |
12:39 |
Sent To |
PC |
|
| Notes |
| 2007-03-27 13:11:25 | | | | | | | | | | DENIED/INCOMPLETE INFORMATION | | | | | | SAME COMMENT AS LAST REVIEW. THERE IS AN ELECTRICAL | | | "PANEL" SHOWN ON THE ELECTRICAL SCHEMATIC. THIS WOULD | | | APPEAR TO BE A "POOL PANEL". IF IT IS EXISTING PLEASE | | | INDICATE ON THE PLAN. IF IT IS BEING INSTALLED AS PART | | | OF THIS PERMIT, SUBMIT THE FOLLOWING DETAILS ON THE | | | PLAN: | | | | | | MAKE THE FOLLOWING CORRECTIONS FOR CODE COMPLIANCE AND | | | RESUBMIT FOR REVIEW. | | | | | | PLEASE SUBMIT DETAILS FOR THE PANEL SHOWN ON THE | | | SCHEMATIC, FEEDER AND CONDUIT SIZE AND TYPE, PANEL | | | RATING AND OCP, | | | PANEL SCHEDULE AND COMPUTED LOAD, ETC. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-03-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-03-08 |
Time |
06:54 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-03-08 |
Time |
06:29 |
Sent To |
P |
|
| Notes |
| 2007-03-08 06:49:44 | | | | DENIED/INCOMPLETE INFORMATION | | | | | | SAME COMMENT AS LAST REVIEW. THERE IS AN ELECTRICAL | | | "PANEL" SHOWN ON THE ELECTRICAL SCHEMATIC. THIS WOULD | | | APPEAR TO BE A "POOL PANEL". IF IT IS EXISTING PLEASE | | | INDICATE ON THE PLAN. IF IT IS BEING INSTALLED AS PART | | | OF THIS PERMIT, SUBMIT THE FOLLOWING DETAILS ON THE | | | PLAN: | | | | | | MAKE THE FOLLOWING CORRECTIONS FOR CODE COMPLIANCE AND | | | RESUBMIT FOR REVIEW. | | | | | | PLEASE SUBMIT DETAILS FOR THE PANEL SHOWN ON THE | | | SCHEMATIC, FEEDER AND CONDUIT SIZE AND TYPE, PANEL | | | RATING AND OCP, | | | PANEL SCHEDULE AND COMPUTED LOAD, ETC. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-02-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-02-01 |
Time |
08:01 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2007-02-01 |
Time |
07:55 |
Sent To |
P |
|
| Notes |
| 2007-02-01 08:00:55 | | | | DENIED/INCOMPLETE INFORMATION | | | | | | MAKE THE FOLLOWING CORRECTIONS FOR CODE COMPLIANCE AND | | | RESUBMIT FOR REVIEW. | | | | | | PLEASE SUBMIT DETAILS FOR THE PANEL | | | SHOWN ON THE SCHEMATIC, FEEDER AND CONDUIT SIZE AND | | | TYPE, PANEL RATING AND OCP, | | | PANEL SCHEDULE AND COMPUTED LOAD, ETC. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2007-02-05 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-02-05 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-02-05 |
Time |
16:27 |
Sent To |
B |
|
| Notes |
| 2007-02-05 16:28:40 | CONTRACTOR INFORMATION | | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL POOL INSPECTION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-03-28 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-03-28 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-03-28 |
Time |
17:46 |
Sent To |
E |
|
| Notes |
| 2007-03-28 17:47:08 | TO BILL TROBAUGH |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-03-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-20 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-20 |
Time |
10:16 |
Sent To |
E |
|
| Notes |
| 2007-03-20 10:17:31 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-03-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-01 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-01 |
Time |
16:04 |
Sent To |
E |
|
| Notes |
| 2007-03-01 16:05:20 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-01-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-31 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-31 |
Time |
11:52 |
Sent To |
E |
|
| Notes |
| 2007-01-31 11:53:04 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2007-02-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-20 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2007-01-20 13:07:00 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-03-13 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-03-13 |
Time |
10:54 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-03-13 |
Time |
10:53 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-02-05 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-02-05 |
Time |
16:00 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-02-05 |
Time |
16:00 |
Sent To |
G |
|
| Notes |
| 2007-02-05 16:26:16 | DENIED | | | REFERENCE: FBC-2004 SECTIONS 424.2 AND R4101, SWIMMING | | | POOLS;CITY OF WEST PALM BEACH AMENDMENTS TO FBC-2004 | | | CHAPTER 1, ADMINISTRATION | | | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING | | | PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1)SHEET 3 OF 3 PLEASE DELETE THE 2001 YEAR REFERENCE | | | AND ADD 2004 YEAR REFERENCE IN ITS PLACE, PER FBC 2004 | | | CHAPTER 1, SECTION 106.1.1 INFORMATION ON ONSTRUCTION | | | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL | | | BE OF SUFFICIENT CLARITY TO INDICATE THE | | | LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE | | | AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS, | | | AS DETERMINED BY THE | | | BUILDING OFFICIAL. | | | | | | 2)FBC-2004 SEC. 424.2.6.6.5, OR | | | FBCR-2004 SEC. R4101.6.6.5 WHERE | | | PROVIDED, THE VACUUM OR PRESSURE CLEANER | | | FITTING SHALL BE LOCATED AT LEAST 6" AND | | | NOT GREATER THAN 12" BELOW THE MINIMUM | | | OPER- ATING WATER LEVEL OR AS AN | | | ATTACHMENT TO THE SKIMMER. | | | NOTE: PLEASE PROVIDE MANUFACTURER CUT SHEET OR INDICATE | | | THE MAKE AND MODEL NUMBER ON THE RESUBMITTED PRINTS. | | | | | | **********IMPORTANT INFORMATION | | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2007-01-27 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2007-01-27 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2007-01-27 |
Time |
09:24 |
Sent To |
I |
|
| Notes |
| 2007-01-29 09:23:36 | PROVISO: SEC 94-304(2)(B) - EVERY SWIMMING POOL SHALL | | | BE ENCLOSED BY A FENCE OR SIMILAR STRUCTURE WHICH IS | | | INSTALLED TO OBSTRUCT ACCESS BY PERSONS OTHER THAN THE | | | OWNERS OR OCCUPANTS OF THE RESIDENCE WITHIIN WHICH A | | | SWIMMING POOL IS LOCATED.BARRIERS OR FENCES SHALL BE | | | AT LEAST FOUR FEET IN HEIGHT ABOVE GRADE. |
|
|