Plan Review Details - Permit 07010842
Plan Review Stops For Permit 07010842
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status N Date 2007-03-07 Cont ID  
Sent By jwitmer Date 2007-03-07 Time 13:59 Rev Time 0.33
Received By jwitmer Date 2007-03-07 Time 13:59 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-01-31 Cont ID  
Sent By dpalmer Date 2007-01-31 Time 15:49 Rev Time 0.00
Received By dpalmer Date 2007-01-31 Time 15:48 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2007-04-12 Cont ID  
Sent By mawillia Date 2007-04-11 Time 19:08 Rev Time 0.00
Received By mawillia Date 2007-04-11 Time 18:49 Sent To  
Notes
2007-04-11 19:03:15*****APPROVED*****
  
  
 PLAN SHEET RE1 STAMPED, INITIALED, AND DATED.
  
  
  
  
  
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-02-27 Cont ID  
Sent By mawillia Date 2007-02-27 Time 17:50 Rev Time 0.00
Received By mawillia Date 2007-02-27 Time 17:50 Sent To  
Notes
2007-02-27 17:59:27*****DENIED*****
  
  
 1.THE COMPLETE ADDRESS SHALL BE IN THE TITLE BLOCK OF
 EACH SUBMITTED PLAN SHEET.
  
 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 3.THE PROPOSED SCOPE SHALL NOT HINDER OR INTERFERE
 WITH EMERGENCY RESPONSE ACCESS TO THE SAID PROPERTY OR
 VICINITY THEREOF (INCLUDING FIRE LANES).
  
 4.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL
 BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR
 MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION.
  
 5.WILL THERE BE MODIFICATIONS TO THE LOCATION OF EXIT
 SIGN LIGHTS, EMERGENCY LIGHTS, FIRE SPRINKLERS, AND /OR
 FIRE ALARM DEVICES DUE TO THE SCOPE OF WORK?IF THE
 FIRE SPRINKLER OR FIRE ALARM SYSTEM ARE TO BE MODIFIED,
 SEPARATE PLANS AND PERMIT WILL BE REQUIRED.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING HOW/WHERE (ON THE PLANS) EACH COMMENT
 WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-06-13 Cont ID  
Sent By adarroug Date 2007-06-13 Time 15:24 Rev Time 0.00
Received By adarroug Date 2007-06-13 Time 15:24 Sent To M
Notes
2007-06-13 15:24:31TO "TGORDON" DESK/RESTAMP

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-03-10 Cont ID  
Sent By adarroug Date 2007-03-10 Time 12:22 Rev Time 0.00
Received By adarroug Date 2007-03-10 Time 12:22 Sent To  
Notes
2007-03-10 12:30:03TO "COMM" BD#35

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-03-07 Cont ID  
Sent By jwitmer Date 2007-03-07 Time 13:59 Rev Time 0.00
Received By jwitmer Date 2007-01-19 Time 10:23 Sent To  
Notes
2007-01-30 10:42:17TO "COMM" BD#42
2007-01-19 10:24:19WAITING FOR "COMM" BD

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-06-14 Cont ID  
Sent By tgordon Date 2007-06-14 Time 09:09 Rev Time 0.30
Received By tgordon Date 2007-06-14 Time 09:09 Sent To  
Notes
2007-06-14 09:10:32RE-STAMP OF PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2007-02-23 Cont ID  
Sent By tgordon Date 2007-02-23 Time 09:38 Rev Time 0.25
Received By tgordon Date 2007-02-23 Time 09:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-04-12 Cont ID  
Sent By jleech Date 2007-04-12 Time 15:05 Rev Time 0.00
Received By jleech Date 2007-04-12 Time 15:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-03-22 Cont ID  
Sent By kstevens Date 2007-03-22 Time 11:21 Rev Time 0.00
Received By kstevens Date 2007-03-22 Time 11:21 Sent To  
Notes
2007-03-22 11:31:52DENIED
 REFERENCE: FBC-2004 CHAPTER 1
  
 1. PLANS SHALL BE SUBMITTED IN TWO OR MORE SETS OF
 PLANS. PLANS WERE SUBMITTED WITH LOOSE SHEETS SEPARATE
 FROM THE SETS. PLEASE REMOVE ALL VOIDED SHEETS AND
 INSERT ALL NEW SHEETS.(PLANS ARE CODE COMPLIANT
 OTHERWISE).
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-02-21 Cont ID  
Sent By kstevens Date 2007-02-21 Time 15:17 Rev Time 0.00
Received By kstevens Date 2007-02-21 Time 11:21 Sent To  
Notes
2007-02-21 15:25:54DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 1, SHT T1 DEMOLITION REQUIREMENTS NOTE #3. IN THE
 REMOVAL OF ANY PART OF THE DRAINAGE SYSTEM, DEAD ENDS
 ARE PROHIBITED. SECTION 704.5. ALL CAPPED SANITARY
 PIPING SHALL BE INDICATED ON THE PLANS AND SHALL NOT BE
 COVERED PRIOR TO INSPECTION.
  
 2. SHT P1 A SANITARY RISER ISOMETRIC DIAGRAM IS
 REQUIRED SHOWING ALL CAPPED LINES AND ALL NEW LINES
 INCLUDING VENTS. SHOW ALL PIPE SIZES, TRAPS, VENTS ETC.
 SECTION 106.3.5.1.3(4)(6)(13).
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]


Account Summary | Usage Policy | Privacy Policy