| Plan Review Stops For Permit 07010580 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-06-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-06-19 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-06-19 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2007-06-19 15:21:15 | 1) BUILDING REVIEW STATUS IS FAILED,UNTIL THE | | | HISTORIC PRESERVATION ISSUES ARE ADDRESSED. | | | | | | 2) THE NOC HAS EXPIRED AND WILL NEED TO BE RERECORDED | | | BEFORE THE PERMIT IS ISSUED. FLORIDA STATUTES REQUIRE | | | THE WORK TO START WITHIN 90 DAYS OF RECORDING THE NOC. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-04-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-04-09 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-04-09 |
Time |
07:14 |
Sent To |
|
|
| Notes |
| 2007-04-09 13:37:24 | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2)THE NEW PLAN SHEETS ARE REQUIRED TO BE RESTAMPED BY | | | THE HISTORICAL REVIEW DEPARTMENT. | | | | | | 3) THE NOTE ON WALL SECTION 2 ON SHEET A3 OF THE PLANS | | | SPECIFIES A HORIZONTAL SLIDING WINDOW AT THE KITCHEN | | | AND THE WINDOW SCHEDULE ON A4 SPECIFIES A CASEMENT | | | WINDOW AT THIS LOCATION. PLEASE CLARIFY. | | | | | | 4) THE PRODUCT APPROVALS SUBMITTED FOR THE HORIZONTAL | | | SLIDING WINDOW HAVE BEEN REVSED. PLEASE SUBMIT THE NEW | | | FL COVERSHEET WITH NUMBER FL242-R5 AND NOA # | | | 03-0612.06. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-02-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-02-21 |
Time |
18:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-02-21 |
Time |
18:19 |
Sent To |
|
|
| Notes |
| 2007-02-21 19:06:09 | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT | | | MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) THE WORK DESCRIPTION ON THE APPLICATION IS FOR | | | INTERIOR REMDELING. THE PLANS SHOW NEW EXTERIOR WALLS | | | AND INCREASING OPENING SIZE, IN ADDITION TO REPLACING | | | WINDOWS AND DOORS. PLEASE REVISE WORK DESCRIPTION ON | | | THE APPLICATION. | | | | | | 3) SPECIFY THE LEVEL OF ALTERATION ON THE PLANS. SEE | | | 2004 FBC EXISTING BUILDING CHAPTER 3. | | | | | | 4)PROVIDE AT LEAST ONE BATHROOM, LOCATED WITH MAXIMUM | | | POSSIBLE PRIVACY, WHERE BATHROOMS ARE PROVIDED ON | | | HABITABLE GRADE LEVELS, WITH A DOOR THAT HAS A 29-INCH | | | (737 MM) CLEAR OPENING AS REQUIRED BY R322.1.1 AND FBC | | | CHAPTER 11. | | | | | | 5) THE PLANS SPECIFY MARVIN WINDOWS AND DOORS ON A4 AND | | | A5 AND DO NOT SPECIFY OR EQUAL. THE PRODUCT APPROVALS | | | SUBMITTED ARE FOR PGT WINDOWS AND DOORS. PLEASE REVISE | | | PLANS. | | | | | | 6) THE MASTER BEDROOM WINDOW IS LABELED"C" ON SHEET | | | A1 AND THE WINDOW SCHEDULE ON A4 HAS "D" FOR THIS | | | WINDOW. PLEASE CORRECT. | | | | | | 7) THE NEW MASTER BEDROOM WINDOW IS REQUIRED TO COMPLY | | | WITH R310.1 FOR EMERGENCY ESCAPE AND RESCUE OPENINGS. | | | SHOW COMPLIANCE. | | | | | | 8) ON A3 THE REAR (WEST) ELEVATION IS INCORRECTLY | | | LABELED. PLEASE CORRECT. | | | | | | 9) PROVIDE WINDOW AND DOOR BUCK DETAILS ON THE PLANS. | | | SPECIFY THE FASTENERS AND SPACING. | | | | | | 10) PROVIDE A STRUCTURAL DETAIL AT THE ENLARGED OPENING | | | FOR THE NEW FRENCH DOOR. SPECIFY WALL AND BEAM | | | REINFORCEMENT. | | | | | | 11) PROVIDE STRUCTURAL DETAILS FOR THE NEW CBS IN-FILL | | | WALLS AT THE MASTER BEDROOM ALCOVE AND AT THE FAMILY | | | ROOM. SPECIFY REINFORCEMENT, TIE TO EXISTING STRUCTURE, | | | LINTELS, BEAMS, ETC. | | | | | | 12) PROVIDE STRUCTURAL DETAILS FOR THE CONSTRUCTION OF | | | THE ARCH ABOVE THE NEW ARCH TOP WINDOW AT MASTER | | | BEDROOM ALCOVE. | | | | | | 13) SUBMIT 2 CURRENT PRODUCT APPROVALS FOR STRUCTURAL | | | MULLIONS. | | | | | | 14)PRODUCT APPROVALS WERE SUBMITTED FOR SINGLE HUNG | | | WINDOWS AND HORIZONTAL SLIDING WINDOWS WHICH ARE NOT | | | THE TYPES OF WINDOWS SPECIFIED ON THE PLANS AS BEING | | | REPLACED. THE PLANS APPEAR TO SPECIFY THE NEW WINDOWS | | | AS CASEMENT AND FIXED WINDOWS. PLEASE CLARIFY WINDOW | | | TYPES, SIZES AND LOCATIONS.. | | | | | | 15) THE PRDOUCT APPROVALS FOR THE PGT HORIZONTAL SLIDER | | | HAS BEEN REVISED. SUBMIT NOA 03-0612.06 WITH STATE | | | COVERSHEET. | | | | | | 16) THE COVERSHEET FOR THE PGT FIXED WINDOWS IS FOR THE | | | 2001 CODE AND HAS BEEN REVISED. REPLACE PAGE 6 OF THE | | | NOA WHICH IS ILLEGIBLE. | | | | | | 17) THE COVERSHEET FOR THE PGT CASEMENTWINDOWS IS FOR | | | THE 2001 CODE AND HAS BEEN REVISED. THE NOA HAS BEEN | | | REVISED TO 05-1129.11. SUBMIT CURRENT COPIES OF BOTH. | | | | | | 18) THE NOA FOR THE PGT FRENCH DOORS IS EXPIRED. SUBMIT | | | CURRENT NOA. SEE WWW,FLORIDABUILDING .ORG. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2007-01-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-01-12 |
Time |
07:40 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2007-01-12 |
Time |
06:38 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2007-05-21 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-05-21 |
Time |
13:15 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-05-21 |
Time |
13:15 |
Sent To |
B |
|
| Notes |
| 2007-05-21 13:20:28 | NOTE: GAS PERMIT REQUIRED | | | | | | ****************PROVISO**************** | | | THE CORRECT TABLE FOR UNDERGROUND POLYETHLENE (PE) | | | NATURAL GAS PIPE FOR A 0.5 PSI IS 402.4(20) | | | | | | IF DRYER ROOM IS A CONFINED SPACE, OPEN- | | | INGS REQUIRED PER SECTION 304.5 OR | | | SECTION 304.6 SHALL BE INSTALLED. | | | MINIMUM 2,500 CUBIC FEET REQUIRED. | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2007-04-03 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-04-03 |
Time |
11:02 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-04-03 |
Time |
11:02 |
Sent To |
B |
|
| Notes |
| 2007-04-03 11:48:32 | DENIED 2ND TIME | | | REFERENCE: | | | ** FBC-2004 FUEL GAS. | | | ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION | | | REQUIREMENTS. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ARE STILL | | | IN NEED OF ADDRESSING ALONG WITH SOME NEW COMMENTS, | | | SOME BASED ON PLANS NOW SUBMITTED, NEW DOCUMENTS BEING | | | REVIEWED FOR THE FIRST TIME AND SOME NEW COMMENTS NOT | | | MADE ON PREVIOUS REVIEWS. | | | | | | ** PLEASE SEE THE NOTES BELOW ARE TAKEN DIRECTLY FROM | | | PREVIOUS REVIEW WITH A NO, OK OR A NO/OK. | | | THESE WILL BE FOR THE EXACT NUMERICAL NOTATION OF THE | | | PREVIOUS REVIEW NOTES. | | | | | | A NO IS IF THE COMMENT WAS NOT FULLY ADDRESSED AND/OR | | | FURTHER EXPLANATION OR CHANGES IN PLANS OR DOCUMENTS | | | ARE STILL NEEDED. THIS REVIEWER WILL TRY TO BETTER | | | EXPLAIN NOTE ABOVE PREVIOUS REVIEW COMMENT. | | | | | | AN OK WILL BE LABELED AS SUCH ON THE SAME NUMERICAL | | | COMMENT AND WILL HAVE OLD NOTE REMOVED FROM COMMENTS. | | | | | | A NO/OK MEANS PART OF THE COMMENT MAY HAVE BEEN | | | ADDRESSED, HOWEVER NOT ALL OF THE PREVIOUS REVIEW | | | COMMENT MAY HAVE BEEN FULLY ADDRESSED. | | | | | | ** PLEASE SEE ANY NEW NOTES WILL BE ADDED TO THE END OF | | | THE PREVIOUS REVIEW COMMENTS AND NOTED AS SUCH. | | | | | | 1. **OK** | | | | | | 2. **OK** | | | | | | 3. **OK** | | | | | | NOW THAT THE ABOVE GROUND GAS PIPING HAS BEEN | | | ESTABLISHED AS BEING GALVANIZED STEEL ON THE | | | RESUBMITTAL THE FOLLOWING ARE NEW COMMENTS: | | | | | | 4. SHEET P-3 ISOMETRIC GAS RISER DIAGRAM: GAS PIPE TO | | | 19O,000 BTU TANKLESS W/HTR. NEEDS TO BE INCREASED TO | | | ONE INCH (1") PER FBC-2004 FUEL GAS TABLE 402.4 (2). | | | PLEASE REFERENCE THE ATTACHED GAS SIZING TABLES TO THE | | | GAS COMMENTS INDICATING THE NEED FOR THE PIPING | | | INCREASE. | | | | | | 5. SHEET P-3 ISOMETRIC GAS RISER DIAGRAM GAS PIPING TO | | | THE NEW RANGE IS CONFUSING, ISOMETRIC IS INDICATING | | | THREE SEPERATE CONNECTIONS TO THE APPLIANCE WITH A BTU | | | LOAD OF 44,000 BTU'S. SHEET A-1 IS INDICATING A NEW GAS | | | RANGE WITHPOSSIBLY SIX BURNERS (FOUR INDIVIDUAL | | | BURNERS AND POSSIBLY TWO SIDE BURNERS FOR A SIDE | | | GRIDDLE OR GRILL, INDIVIDUAL BURNER BTU LOAD IS AT | | | 15,000 WITH A TOTAL BTU LOAD INCLUDING THE OVENS IS | | | POSSIBLY 137,000 BTU,S)PLEASE SUBMIT MANUFACTURER | | | SPECIFICATIONS OF ALL APPLIANCES (GRILL, TANKLESS WATER | | | HEATER, AND NEW GAS RANGE) VERIFYING THE BTU LOADS WITH | | | THE ISOMETRIC AND SHOWING LISTINGS FROM A NATIONALLY | | | RECOGNIZED TESTING LABORATORY (NRTL). | | | | | | ********IMPORTANT INFORMATION******** | | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | | TRANSMITTAL LETTER INDICATING HOW EACH | | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2007-01-22 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-01-22 |
Time |
08:59 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-01-22 |
Time |
08:59 |
Sent To |
B |
|
| Notes |
| 2007-01-22 09:24:43 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS AND THE CITY OF WEST PALM | | | BEACH GAS PERMIT APPLICATION REQUIREMENTS. | | | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR GAS PLAN | | | REVIEW TO MEET CODE REQUIREMENTS: | | | | | | 1.SHEET P-3 GAS ISOMETRIC: PLEASE INDICATE ALL PIPING | | | MATERIAL BEING USED. THE ONLY GAS PIPE MATERIAL | | | INDICATED AS BEING USED IS PE FOR THE UNDERGROUND. WHAT | | | PIPING MATERIAL IS BEING USED ABOVE GROUND? | | | | | | 2. SHEET P-3 GAS ISOMETRIC: THE TOTAL DISTANCE IS | | | INDICATED WRONG AS 51'. THE CORRECT TOTAL DISTANCE IS | | | SIXTY SEVEN FEET SIX INCHES (67'-6")PLEASE CORRECT ON | | | THE RESUBMITTAL. | | | | | | 3. SHEET P-3 GAS ISOMETRIC: PLEASE CLARIFY CHIMNEY | | | 50,000 BTU'S. IS THERE A FIRE PLACE, IF SO WHERE IS THE | | | GAS PIPING? | | | | | | **********IMPORTANT INFORMATION | | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-06-19 |
|
|
Cont ID |
|
| Sent By |
bpowell |
Date |
2007-06-19 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
bpowell |
Date |
2007-06-19 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2007-06-19 14:37:11 | RECONSIDER DECORATIVE NICHE DESIGN ANDONE WINDOW |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
N |
Date |
2007-01-09 |
|
|
Cont ID |
|
| Sent By |
swurafti |
Date |
2007-01-09 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
swurafti |
Date |
2007-01-09 |
Time |
12:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-05-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-08 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-08 |
Time |
13:54 |
Sent To |
G |
|
| Notes |
| 2007-05-08 13:55:30 | TO "G" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-03-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-16 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-16 |
Time |
16:24 |
Sent To |
P |
|
| Notes |
| 2007-03-16 16:24:37 | TO "P" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-02-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-02-22 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-01-11 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2007-01-11 16:45:10 | TO "E" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2007-01-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-01-12 |
Time |
14:26 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-01-12 |
Time |
14:26 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-05-21 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-05-21 |
Time |
13:12 |
Rev Time |
0.20 |
| Received By |
mperson |
Date |
2007-05-21 |
Time |
13:12 |
Sent To |
G |
|
| Notes |
| 2007-05-21 13:14:32 | NOTE: PLUMBING PERMIT REQUIRED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-04-03 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-04-03 |
Time |
11:01 |
Rev Time |
0.20 |
| Received By |
mperson |
Date |
2007-04-03 |
Time |
11:01 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-01-22 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-01-22 |
Time |
08:33 |
Rev Time |
0.55 |
| Received By |
mperson |
Date |
2007-01-22 |
Time |
08:33 |
Sent To |
G |
|
| Notes |
| 2007-01-22 08:58:03 | DENIED | | | REFERENCE: FBC-2004 PLUMBING AND FBC-2004 CHAPTER 1, | | | CITY OF WEST PALM BEACH AMENDMENTS. | | | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING | | | PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. SHEET P-3 SANITARY ISOMETRIC: A} PER FBC-2004 | | | CHAPTER 1, SECTION 106.3.5.4, PLEASE SIZE ALL FIXTURE | | | TRAPS. B} PER FBC-2004 PLUMBING SECTION406.3 WASTE | | | CONNECTIONS.THE TRAP AND | | | FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES | | | WASHER SHALL BE A MINIMUM OF 2 INCHES | | | (51MM) IN DIAMETER. THE AUTOMATIC | | | CLOTHES WASHER FIXTURE DRAIN SHALL | | | CONNECT TO A BRANCH DRAIN OR DRAINAGE | | | STACK A MINIMUM OF 3 INCHES (76MM) IN | | | DIAMETER. C} PER FBC-2004 PLUMBING SECTION 708.9 ACCESS | | | SHALL BE PROVIDED TO ALL CLEANOUTS. PLEASE INDICATE THE | | | CLEANOUT FOR THE WASHING MACHINE AT FOUR FEET ABOVE | | | FINNISH FLOOR (4' A.F.F.) ON THE RESUBMITTAL. | | | | | | **********IMPORTANT INFORMATION | | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|