Plan Review Details - Permit 07010563
Plan Review Stops For Permit 07010563
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-06-25 Cont ID  
Sent By rmcdouga Date 2007-06-25 Time 13:51 Rev Time 0.00
Received By rmcdouga Date 2007-06-25 Time 13:51 Sent To  
Notes
2007-06-25 14:18:23DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) THE PRDUCT APPROVAL THAT WAS SUBMITTED FOR THE .050
 SOLID BERTHA ALUMINUM HAS BEEN REVISED BY NOA
 05-0926.03. SUBMIT THE NEW PRODUCT APPROVAL. THE
 DESIGNER OF RECORD IS REQUIRED TO APPROVE THE PRODUCT
 APPROVAL IN WRITING. WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.. THERE WAS ANOTHER PRODUCT
 APPROVAL SUBMITTED FOR STEEL STORM PANELS. PLEASE
 CLARIFY IF BOTH TYPES OF PANELS BEING USED AND IF NOT
 PLEASE REMOVE THE PRODUCT APPROVALS FOR THE ONES THAT
 ARENOT BEING INSTALLED.
  
 4)ON THE PRODUCT APPROVALS FOR THE STORM PANELS,
 CIRCLE THE MOUNT TYPE, FASTENERS AND FASTENER SPACING
 THAT WILL BE USED TO INSTALL THE PANELS.
  
 5) ADDRESS COMENTS FROM ZONING REVIEW.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-02-28 Cont ID  
Sent By rmcdouga Date 2007-02-28 Time 15:19 Rev Time 0.00
Received By rmcdouga Date 2007-02-28 Time 15:19 Sent To  
Notes
2007-02-28 16:10:15DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) SUBMIT ENERGY CALCULATIONS AS REQUIRED BY FBC
 CHAPTER 13.
  
 4) THERE IS A TYPO ON SHEET 1 FOR THE INTERNAL PRESSURE
 COEFFIECENT. IT SHOULD READ + / - 0.18.
  
 5)R807.1 ATTIC ACCESS .
 IN BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF
 CONSTRUCTION, AN ATTIC ACCESS OPENING SHALL BE PROVIDED
 TO ATTIC AREAS THAT EXCEED 30 SQUARE FEET (2.8 M 2 )
 AND HAVE A VERTICAL HEIGHT OF 30 INCHES (762 MM) OR
 GREATER.
 THE ROUGH-FRAMED OPENING SHALL NOT BE LESS THAN 22
 INCHES BY 30 INCHES (559 MM BY 762 MM) AND SHALL BE
 LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE
 LOCATION. A 30-INCH (762 MM) MINIMUM UNOBSTRUCTED
 HEADROOM IN THE ATTIC SPACE SHALL BE PROVIDED AT SOME
 POINT ABOVE THE ACCESS OPENING. SEE SECTION M1305.1.3
 FOR ACCESS REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS
 LOCATED IN ATTICS. SPECIFY HOW ATTIC ACCESS TO
 ADDITIONS WILL BE ACHIEVED.
  
 6) A PRODUCT APPROVAL WAS SUBMITTED FOR A MASONITE
 INTERNATIONAL EXTERIOR DOOR. THE PLANS AND WORK
 DESCRIPTION ON THE PERMIT DO NOT SPECIFY ANY NEW
 EXTERIOR DOORS. ALSO THE PRODUCT APPROVAL THAT WAS
 SUBMITTED IS EXPIRED.
  
 7) SPECIFY THE MOUNT TYPE, FASTENER TYPE & SPACING AND
 REQUIRED WINDLOAD DESIGN PRESSURE FOR THE HURRICANE
 PANELS. CIRCLE THE APPROPRIATE ITEMS ON THE PRODUCT
 APPROVALS.
  
 8) THE VALUE OF THE WORK HAS BEEN INCREASED BASED ON
 ICC CONSTRUCTION COSTS. ADDITIONAL PERMIT FEES ARE
 DUE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-05-18 Cont ID  
Sent By btrobaug Date 2007-05-18 Time 16:05 Rev Time 0.33
Received By btrobaug Date 2007-05-18 Time 16:02 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-01-23 Cont ID  
Sent By btrobaug Date 2007-01-23 Time 07:33 Rev Time 0.33
Received By btrobaug Date 2007-01-23 Time 07:25 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-05-18 Cont ID  
Sent By adarroug Date 2007-05-18 Time 13:25 Rev Time 0.00
Received By adarroug Date 2007-05-18 Time 13:25 Sent To E
Notes
2007-05-18 13:25:28TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-05-14 Cont ID  
Sent By adarroug Date 2007-05-14 Time 09:41 Rev Time 0.00
Received By adarroug Date 2007-05-14 Time 09:41 Sent To Z
Notes
2007-05-14 09:42:01TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-01-22 Cont ID  
Sent By adarroug Date 2007-01-22 Time 16:45 Rev Time 0.00
Received By adarroug Date 2007-01-22 Time 16:45 Sent To E
Notes
2007-01-22 16:45:54TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-02-28 Cont ID  
Sent By rmcdouga Date 2007-02-28 Time 15:19 Rev Time 0.00
Received By rmcdouga Date 2007-01-10 Time 15:57 Sent To  
Notes
2007-01-10 16:01:14TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2007-05-23 Cont ID  
Sent By tgordon Date 2007-05-23 Time 14:50 Rev Time 0.20
Received By tgordon Date 2007-05-23 Time 14:50 Sent To B
Notes
2007-05-23 14:51:56NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2007-01-23 Cont ID  
Sent By tgordon Date 2007-01-23 Time 13:32 Rev Time 0.15
Received By tgordon Date 2007-01-23 Time 13:32 Sent To B
Notes
2007-01-23 13:34:07NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-05-23 Cont ID  
Sent By mperson Date 2007-05-23 Time 11:47 Rev Time 0.33
Received By mperson Date 2007-05-23 Time 11:47 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-01-23 Cont ID  
Sent By mperson Date 2007-01-23 Time 10:09 Rev Time 0.33
Received By mperson Date 2007-01-23 Time 10:09 Sent To M
Notes
2007-01-23 10:39:56DENIED
 REFERENCE: FBC-2004 PLUMBING
  
 THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING
 PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. SHEET D-1 SANITARY RISER DIAGRAM DOES NOT REFLECT
 THE FLOOR PLAN SHEET 1. PLEASE REFERENCE AN ATTACHED
 SANITARY RISER DIAGRAM TO THE PLUMBING COMMENTS
 REFLECTING THE FLOOR PLAN FOR THE RESUBMITTAL.
  
 2. SHEET D-1 SANITARY RISER DIAGRAM: PLEASE DELETE
 @1-1/2" BY THE LAV. VENT ON THE RESUBMITTAL.
  
 3. SHEET D-1 SANITARY RISER DIAGRAM INDICATES 4" TO
 SEPTIC SEWER, DOES RESIDENCE HAVE A SEPTIC TANK IF NOT
 PLEASE DELETE SEPTIC SEWER AND ADD SANITARY SEWER IN
 ITS PLACE ON HTE RESUBMITTAL.
  
 **********IMPORTANT INFORMATION
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop Z ZONING
Rev No 2 Status F Date 2007-05-15 Cont ID  
Sent By choops Date 2007-05-15 Time 15:19 Rev Time 0.00
Received By choops Date 2007-05-15 Time 15:19 Sent To I
Notes
2007-05-15 15:21:35***FAILED***
  
  
 1)SURVEYS DO NOT MATCH SITE PLANS, PLEASE CORRECT.
  
 2)PLEASE SHOW DIMENSIONS FROM PROPERTY LINES TO
 PROPOSED ADDITTIONS ON SURVEYS.
  
 3)MODIFICATIONS TO DRIVEWAY AND WALKS SHOULD BE
 SHOWN ON SURVEYS.
  
  
 CHRIS HOOPS
 ZONING TECHNICIAN
 561-805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2007-01-20 Cont ID  
Sent By mmclean Date 2007-01-20 Time 10:55 Rev Time 0.00
Received By mmclean Date 2007-01-20 Time 10:55 Sent To I
Notes
2007-01-20 10:58:14DENIED,
 1. PLEASE SUBMIT TWO COPIES OF SURVEYS SHOWING THE
 PROPOSED ADDITION WITH SETBACKS.
 2. PLEASE SHOW THE A/C UNIT (IF NEW) WITH SETBACKS ON
 THE TWO COPIES SURVEYS.
 3. THE SUBMITTED SURVEYS SHALL BE A CURRENT SURVEYS.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720