| Plan Review Stops For Permit 07010563 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-06-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-06-25 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-06-25 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2007-06-25 14:18:23 | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT | | | MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3) THE PRDUCT APPROVAL THAT WAS SUBMITTED FOR THE .050 | | | SOLID BERTHA ALUMINUM HAS BEEN REVISED BY NOA | | | 05-0926.03. SUBMIT THE NEW PRODUCT APPROVAL. THE | | | DESIGNER OF RECORD IS REQUIRED TO APPROVE THE PRODUCT | | | APPROVAL IN WRITING. WPB ADMIN CODE 106.3* PRODUCT | | | APPROVALS. THOSE PRODUCT WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL.. THERE WAS ANOTHER PRODUCT | | | APPROVAL SUBMITTED FOR STEEL STORM PANELS. PLEASE | | | CLARIFY IF BOTH TYPES OF PANELS BEING USED AND IF NOT | | | PLEASE REMOVE THE PRODUCT APPROVALS FOR THE ONES THAT | | | ARENOT BEING INSTALLED. | | | | | | 4)ON THE PRODUCT APPROVALS FOR THE STORM PANELS, | | | CIRCLE THE MOUNT TYPE, FASTENERS AND FASTENER SPACING | | | THAT WILL BE USED TO INSTALL THE PANELS. | | | | | | 5) ADDRESS COMENTS FROM ZONING REVIEW. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-02-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-02-28 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-02-28 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2007-02-28 16:10:15 | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT | | | MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3) SUBMIT ENERGY CALCULATIONS AS REQUIRED BY FBC | | | CHAPTER 13. | | | | | | 4) THERE IS A TYPO ON SHEET 1 FOR THE INTERNAL PRESSURE | | | COEFFIECENT. IT SHOULD READ + / - 0.18. | | | | | | 5)R807.1 ATTIC ACCESS . | | | IN BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF | | | CONSTRUCTION, AN ATTIC ACCESS OPENING SHALL BE PROVIDED | | | TO ATTIC AREAS THAT EXCEED 30 SQUARE FEET (2.8 M 2 ) | | | AND HAVE A VERTICAL HEIGHT OF 30 INCHES (762 MM) OR | | | GREATER. | | | THE ROUGH-FRAMED OPENING SHALL NOT BE LESS THAN 22 | | | INCHES BY 30 INCHES (559 MM BY 762 MM) AND SHALL BE | | | LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE | | | LOCATION. A 30-INCH (762 MM) MINIMUM UNOBSTRUCTED | | | HEADROOM IN THE ATTIC SPACE SHALL BE PROVIDED AT SOME | | | POINT ABOVE THE ACCESS OPENING. SEE SECTION M1305.1.3 | | | FOR ACCESS REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS | | | LOCATED IN ATTICS. SPECIFY HOW ATTIC ACCESS TO | | | ADDITIONS WILL BE ACHIEVED. | | | | | | 6) A PRODUCT APPROVAL WAS SUBMITTED FOR A MASONITE | | | INTERNATIONAL EXTERIOR DOOR. THE PLANS AND WORK | | | DESCRIPTION ON THE PERMIT DO NOT SPECIFY ANY NEW | | | EXTERIOR DOORS. ALSO THE PRODUCT APPROVAL THAT WAS | | | SUBMITTED IS EXPIRED. | | | | | | 7) SPECIFY THE MOUNT TYPE, FASTENER TYPE & SPACING AND | | | REQUIRED WINDLOAD DESIGN PRESSURE FOR THE HURRICANE | | | PANELS. CIRCLE THE APPROPRIATE ITEMS ON THE PRODUCT | | | APPROVALS. | | | | | | 8) THE VALUE OF THE WORK HAS BEEN INCREASED BASED ON | | | ICC CONSTRUCTION COSTS. ADDITIONAL PERMIT FEES ARE | | | DUE. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-05-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-05-18 |
Time |
16:05 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2007-05-18 |
Time |
16:02 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2007-01-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-01-23 |
Time |
07:33 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2007-01-23 |
Time |
07:25 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-05-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-18 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-18 |
Time |
13:25 |
Sent To |
E |
|
| Notes |
| 2007-05-18 13:25:28 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-05-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-14 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-14 |
Time |
09:41 |
Sent To |
Z |
|
| Notes |
| 2007-05-14 09:42:01 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-01-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-22 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-22 |
Time |
16:45 |
Sent To |
E |
|
| Notes |
| 2007-01-22 16:45:54 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-02-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-02-28 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-01-10 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2007-01-10 16:01:14 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2007-05-23 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-05-23 |
Time |
14:50 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-05-23 |
Time |
14:50 |
Sent To |
B |
|
| Notes |
| 2007-05-23 14:51:56 | NO MECHANICAL PLANS SUBMITTED, AND NO | | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | | THIS TIME. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2007-01-23 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-01-23 |
Time |
13:32 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2007-01-23 |
Time |
13:32 |
Sent To |
B |
|
| Notes |
| 2007-01-23 13:34:07 | NO MECHANICAL PLANS SUBMITTED, AND NO | | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | | THIS TIME. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-05-23 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-05-23 |
Time |
11:47 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-05-23 |
Time |
11:47 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-01-23 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-01-23 |
Time |
10:09 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-01-23 |
Time |
10:09 |
Sent To |
M |
|
| Notes |
| 2007-01-23 10:39:56 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING | | | PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. SHEET D-1 SANITARY RISER DIAGRAM DOES NOT REFLECT | | | THE FLOOR PLAN SHEET 1. PLEASE REFERENCE AN ATTACHED | | | SANITARY RISER DIAGRAM TO THE PLUMBING COMMENTS | | | REFLECTING THE FLOOR PLAN FOR THE RESUBMITTAL. | | | | | | 2. SHEET D-1 SANITARY RISER DIAGRAM: PLEASE DELETE | | | @1-1/2" BY THE LAV. VENT ON THE RESUBMITTAL. | | | | | | 3. SHEET D-1 SANITARY RISER DIAGRAM INDICATES 4" TO | | | SEPTIC SEWER, DOES RESIDENCE HAVE A SEPTIC TANK IF NOT | | | PLEASE DELETE SEPTIC SEWER AND ADD SANITARY SEWER IN | | | ITS PLACE ON HTE RESUBMITTAL. | | | | | | **********IMPORTANT INFORMATION | | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-05-15 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-05-15 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-05-15 |
Time |
15:19 |
Sent To |
I |
|
| Notes |
| 2007-05-15 15:21:35 | ***FAILED*** | | | | | | | | | 1)SURVEYS DO NOT MATCH SITE PLANS, PLEASE CORRECT. | | | | | | 2)PLEASE SHOW DIMENSIONS FROM PROPERTY LINES TO | | | PROPOSED ADDITTIONS ON SURVEYS. | | | | | | 3)MODIFICATIONS TO DRIVEWAY AND WALKS SHOULD BE | | | SHOWN ON SURVEYS. | | | | | | | | | CHRIS HOOPS | | | ZONING TECHNICIAN | | | 561-805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-01-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2007-01-20 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2007-01-20 |
Time |
10:55 |
Sent To |
I |
|
| Notes |
| 2007-01-20 10:58:14 | DENIED, | | | 1. PLEASE SUBMIT TWO COPIES OF SURVEYS SHOWING THE | | | PROPOSED ADDITION WITH SETBACKS. | | | 2. PLEASE SHOW THE A/C UNIT (IF NEW) WITH SETBACKS ON | | | THE TWO COPIES SURVEYS. | | | 3. THE SUBMITTED SURVEYS SHALL BE A CURRENT SURVEYS. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|