Plan Review Details - Permit 07010392
Plan Review Stops For Permit 07010392
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-05-08 Cont ID  
Sent By rmcdouga Date 2007-05-08 Time 14:20 Rev Time 0.00
Received By rmcdouga Date 2007-05-08 Time 14:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-04-19 Cont ID  
Sent By rmcdouga Date 2007-04-19 Time 14:11 Rev Time 0.00
Received By rmcdouga Date 2007-05-08 Time 14:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2007-02-16 Cont ID  
Sent By rmcdouga Date 2007-02-16 Time 18:36 Rev Time 0.00
Received By rmcdouga Date 2007-02-16 Time 18:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-05-07 Cont ID  
Sent By btrobaug Date 2007-05-07 Time 16:03 Rev Time 0.25
Received By btrobaug Date 2007-05-07 Time 15:57 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-04-19 Cont ID  
Sent By btrobaug Date 2007-04-19 Time 09:39 Rev Time 0.50
Received By btrobaug Date 2007-04-19 Time 09:30 Sent To B
Notes
2007-04-19 09:38:59 
  
 DENIED/INCOMPLETE
  
 1} THE SMOKRE DETECTORS THAT ARE REQUIRED PER 313.1.1
 FBC (RESIDENTIAL) WERE REDLINED ON THE PREVIOUS REVIEW,
 AND THAT WAS NOT CORRECTED ON THE RESUBMITTED PLANS.
 ADD SAME TO PLANS.
  
 2} BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE
 PER 210.11(C) (3), LOCATED PER 210.52(D), AND BE GFI
 PROTECTED PER 210.8(A) (1). INDICATE SAME ON PLAN. SEE
 REDLINE SET FROM PREVIOUS REVIEW.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-01-18 Cont ID  
Sent By btrobaug Date 2007-01-18 Time 07:24 Rev Time 0.50
Received By btrobaug Date 2007-01-18 Time 06:59 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-05-02 Cont ID  
Sent By adarroug Date 2007-05-02 Time 16:25 Rev Time 0.00
Received By adarroug Date 2007-05-02 Time 16:25 Sent To E
Notes
2007-05-02 16:25:40TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-04-04 Cont ID  
Sent By spalmer Date 2007-04-04 Time 17:41 Rev Time 0.00
Received By spalmer Date 2007-04-04 Time 17:41 Sent To P
Notes
2007-04-04 17:41:56TO MIKE PERSON

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-02-16 Cont ID  
Sent By rmcdouga Date 2007-02-16 Time 18:36 Rev Time  
Received By rmcdouga Date   Time   Sent To  
Notes
2007-01-09 10:57:28TO "E" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2007-01-19 Cont ID  
Sent By tgordon Date 2007-01-19 Time 09:41 Rev Time 0.15
Received By tgordon Date 2007-01-19 Time 09:40 Sent To B
Notes
2007-01-19 09:41:41NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-05-08 Cont ID  
Sent By mperson Date 2007-05-08 Time 10:04 Rev Time 0.33
Received By mperson Date 2007-05-08 Time 10:04 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-04-18 Cont ID  
Sent By mperson Date 2007-04-18 Time 11:29 Rev Time 0.33
Received By mperson Date 2007-04-18 Time 11:29 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-01-18 Cont ID  
Sent By mperson Date 2007-01-18 Time 14:30 Rev Time 0.55
Received By mperson Date 2007-01-18 Time 14:30 Sent To M
Notes
2007-01-18 15:03:41DENIED
 REFERENCE: FBC-2004 PLUMBING AND FBC-2004, CHAPTER 1,
 CITY OF WEST PALM BEACH AMENDMENTS:
  
 THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING
 PLAN REVIEW TO MEET CODE COMPLIANCE. PLEASE REFERENCE
 THE CORRECTED SANITARY RISER DIAGRAM ATTACHED TO THE
 PLUMBING COMMENTS FOR THE RESUBMITTAL:
  
 1. MORE INFORMATION REQUIRED. PLEASE
 INDICATE ON DRAWING EXISTING PLUMBING
 LAYOUT, AND ON A SEPERATE DRAWING PLEASE
 INDICATE THE NEW PROPOSED
 PLUMBING LAYOUT. IF NEW PROPOSED
 PLUMBING LAYOUT IS DIFFERENT FROM
 EXISTING PLEASE FOLLOW WHAT IS REQUIRED
 IN #2. IF PLUMBING LAYOUT IS THE SAME
 WITH NO CHANGES, PLEASE INDICATE THIS ON
 THE DRAWING. IF PLUMBING LAYOUT IS THE
 SAME AND THE PLUMBING FIXTURES ARE TO BE
 CHANGED, PLEASE INDCATE ON DRAWING
 FIXTURE CHANGE OUT ONLY.
  
 2. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4
 RESIDENTIAL (ONE AND TWO
 FAMILY) SUBMIT A PLUMBING SANITARY
 ISOMETRIC RISER DIAGRAM INDICATING ALL
 WASTE, VENTS, TRAPS WITH SIZES, AND
 CLEANOUT LOCATIONS.
  
 3 . PER FBC-2004 CHAPTER 1,SECTION 106.3.4.2:
 THE PERSON RESPONSIBLE FOR THE DESIGN OF
 THE DRAWING SHALL CLEARLY PRINT AND SIGN
 NAME, AND ALSO DATE DRAWING. PLEASE DO
 THIS PRIOR TO RESUBMITTING.
  
 4.THE FOLLOWING CORRECTIONS ARE REQUIRED FOR THE
 SANITARY RISER DIAGRAM: A} PER FBC-2004 PLUMBING
 SECTION 903.1: EVERY BUILDING IN WHICH PLUMBING IN
 INSTALLED SHALL HAVE AT LEAST ONE STACK THE SIZE OF
 WHICH IS NOT LESS THAN ONE-HALF OF THE REQUIRED SIZE OF
 THE BUILDING DRAIN;
 B} PER FBC-2004 PLUMBING SECTION 1002.1: TRAP REQUIRED
 FOR TUB; C} PER FBC-2004 PLUMBING SECTION 1002.3: "S"
 TRAPS PROHIBITED.
  
 **********IMPORTANT INFORMATION
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL. PLEASE REFERENCE THE CORRECTED SANITARY
 RISER DIAGRAM ATTACHED TO THE PLUMBING COMMENTS FOR THE
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  
  
  
  
  