Plan Review Details - Permit 07010127
Plan Review Stops For Permit 07010127
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-04-11 Cont ID  
Sent By mjacobs Date 2007-04-11 Time 14:24 Rev Time 0.00
Received By mjacobs Date 2007-04-11 Time 11:55 Sent To PC
Notes
2007-04-11 14:11:49BUILDING PROVISO:
 TO BE IN PLACE AT C.O.:
  
 1) 424.2.17.1 OUTDOOR SWIMMING POOLS.
 OUTDOOR SWIMMING POOLS SHALL BE PROVIDED
 WITH A BARRIER COMPLYING WITH
 424.2.17.1.1 THROUGH 424.2.17.1.14.
  
 424.2.17.1.5 CHILD SAFETY BARRIER
 ASTM D5034 100 LB TENSILE STRNGTH
 ASTM D3787 150 LB BALL BURST
 STRENGTH
  
 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED.
 SPAS AND HEATED SWIMMING POOLS SHALL BE
 EQUIPPED WITH A COVER DESIGNED TO
 MINIMIZE HEAT LOSS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-01-27 Cont ID  
Sent By mjacobs Date 2007-01-27 Time 14:56 Rev Time 0.00
Received By mjacobs Date 2007-01-27 Time 13:44 Sent To PC
Notes
2007-01-27 14:54:00 
 BUILDING PLAN REVIEW
 PERMIT:07010127
 ADD: 7232 HORIZON DR
 CONT: MIRAGE POOLS INC
 TEL: (561)644-0302
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 1ST
 ACTION: DENIED
  
 1) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF
 THE COURT.
 NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS
 NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE
 RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE:
 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT
 THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 2) IF IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION,STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL OR PLUMBING SSTEMS APPERAS
 TO BE UNDERESTIMATED ON THE APPLICATION, THE PERMIT
 SHALL BE DENIED. FOR PERMITTING PURPOSES, VALUATION OF
 BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE
 EXCLUDING LAND. OUR VALUATION REFERENCE IS ICC (BVD),
 MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES PER
 108.3 FBC*.
  
 3)61G15-23.002ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME, ADDRESS, AND LICENSE NUMBER ON EACH SHEET
 BEING FILED FOR PUBLIC RECORD.
  
 4) THE POOL DECKWILL REQUIRE A SEPERATE PERMIT. WHEN
 APPLYING FOR THEPERMIT, INDICATE THE SQUARE FOOTAGE OF
 THE DECK.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-08-16 Cont ID  
Sent By btrobaug Date 2007-08-16 Time 16:01 Rev Time 0.00
Received By btrobaug Date 2007-08-16 Time 15:44 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-04-04 Cont ID  
Sent By btrobaug Date 2007-04-04 Time 07:38 Rev Time 0.33
Received By btrobaug Date 2007-04-04 Time 07:30 Sent To P
Notes
2007-04-04 07:38:37 
  
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 THIS COMMENT WAS ON THE PEVIOUS REVIEW.
  
 1}PLEASE SUBMIT DETAILS FOR THE PANEL SHOWN ON THE
 SCHEMATIC, FEEDER AND CONDUIT SIZE AND TYPE, PANEL
 RATING AND OCP,
 PANEL SCHEDULE AND COMPUTED LOAD, ETC. IF THIS PANEL IS
 EXISTING, INDICATE SAME, IT APPEARS TO BE A NEW
 INSTALLATION WHICH IS THE REASON FOR THIS COMMENT.
  
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW.
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-01-17 Cont ID  
Sent By btrobaug Date 2007-01-17 Time 08:01 Rev Time 0.33
Received By btrobaug Date 2007-01-17 Time 07:47 Sent To P
Notes
2007-01-17 08:01:14 
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW
  
 1}PLEASE SUBMIT DETAILS FOR THE PANEL SHOWN ON THE
 SCHEMATIC, FEEDER AND CONDUIT SIZE AND TYPE, PANEL
 RATING AND OCP,
 PANEL SCHEDULE AND COMPUTED LOAD, ETC. IF THIS PANEL IS
 EXISTING, INDICATE SAME, IT APPEARS TO BE A NEW
 INSTALLATION WHICH IS THE REASON FOR THIS COMMENT.
  
 2} THE 2005 NEC WAS ADOPTED BY THE FLORIDA LEGISLATURE
 EFFECTIVE 8 DECEMBER 2006. THE APPLICATION FOR THIS
 PROJECT WAS AFTER THAT DATE AND THE PLANS ARE SUBJECT
 TO THAT CODE. PLEASE CHANGE ALL NOTES TO REFLECT THIS
 CHANGE. SEE ARTICLE 680.26 AFFECTING BONDING AND
 EQUIPOTENTIAL BONDING.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW.
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2007-01-18 Cont ID  
Sent By mperson Date 2007-01-18 Time 11:23 Rev Time 0.00
Received By mperson Date 2007-01-18 Time 11:23 Sent To B
Notes
2007-01-18 11:25:50CONTRACTOR INFORMATION
 NOTE: GAS PERMIT REQUIRED. GAS CONTRAC-
 TOR TO SUBMIT PLANS WITH PERMIT APPLICA-
 TION. ALL GAS INSPECTIONS TO BE COMPLETE
 BEFORE FINAL POOL INSPECTION.
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-08-09 Cont ID  
Sent By btrobaug Date 2007-08-09 Time 12:07 Rev Time 0.00
Received By btrobaug Date 2007-08-09 Time 12:07 Sent To E
Notes
2007-08-09 12:07:39 
 TO ME./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-04-02 Cont ID  
Sent By spalmer Date 2007-04-02 Time 18:03 Rev Time 0.00
Received By spalmer Date 2007-04-02 Time 18:03 Sent To E
Notes
2007-04-02 18:03:36TO BILL TROBAUGH

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-03-29 Cont ID  
Sent By dpalmer Date 2007-03-29 Time 20:37 Rev Time 0.00
Received By dpalmer Date 2007-03-29 Time 20:35 Sent To Z
Notes
2007-03-29 20:37:20TO ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-01-13 Cont ID  
Sent By adarroug Date 2007-01-13 Time 13:30 Rev Time 0.00
Received By adarroug Date 2007-01-13 Time 13:30 Sent To E
Notes
2007-01-13 13:30:44TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2007-01-27 Time   Rev Time 0.00
Received By adarroug Date 2007-01-04 Time 15:08 Sent To  
Notes
2007-01-04 15:09:04TO "Z" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-04-10 Cont ID  
Sent By mperson Date 2007-04-10 Time 10:02 Rev Time 0.33
Received By mperson Date 2007-04-10 Time 10:02 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-01-18 Cont ID  
Sent By mperson Date 2007-01-18 Time 11:07 Rev Time 0.33
Received By mperson Date 2007-01-18 Time 11:07 Sent To G
Notes
2007-01-18 11:20:53DENIED
 REFERENCE: FBC-2004 SECTION 424 & R4101
  
 THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING
 PLAN REVIEW TO MEET CODE COMPIANCE:
  
 1) FBC-2004 SEC. 424.2.6.6.5, OR
 FBCR-2004 SEC. R4101.6.6.5 WHERE
 PROVIDED, THE VACUUM OR PRESSURE CLEANER
 FITTING SHALL BE LOCATED AT LEAST 6" AND
 NOT GREATER THAN 12" BELOW THE MINIMUM
 OPER- ATING WATER LEVEL OR AS AN
 ATTACHMENT TO THE SKIMMER.(DETAIL
 REQUIRED WITH MODEL NUMBER OR SUBMIT MANUFACTURER CUT
 SHEET)
  
 2) FBC-2004 SEC. 424.2.14.1, OR
 FBCR-2004 SEC. R4101.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. (MANUFACTURE
 SHEETS REQUIRED, PLEASE SUBMIT)
  
 3) FBC-2004 SEC. 424.2.14.2, OR
 FBCR-2004 SEC. R4101.14.2 WATER
 RETENTION, PROVIDE A POSITIVE MEANS OF
 RETAINING WATER IN THE HEATER WHEN PUMP
 IS SHUT OFF.(MANUFACTURE SHEETS
 REQUIRED, PLEASE SUBMIT)
  
 4) FBC-2004 SEC. 424.2.7.2, OR
 FBCR-2004 SEC. R4101.7.2 PUMPS AND
 EQUIPMENT SHALL BE MOUNTED ON A
 SUBSTANTIAL BASE IN A MANNER THAT WILL
 ELIMINATE STRAIN ON PIPING.SLAB SHALL
 BE A NOMINAL 4" THICK. (PLEASE INDICATE POOL EQUIPMENT
 SLAB THICKNESS ON THE RESUBMITTED DETAIL ON SHEET 3 OF
 4)
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2007-04-02 Cont ID  
Sent By mcruz Date 2007-04-02 Time 10:24 Rev Time 0.00
Received By mcruz Date 2007-04-02 Time 10:24 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2007-01-10 Cont ID  
Sent By lfranco Date 2007-01-10 Time 17:47 Rev Time 0.00
Received By mcruz Date 2007-04-02 Time 10:24 Sent To  
Notes
2007-01-10 17:47:21PLANNING AND ZONING: **FAILED**
  
 1.PROVIDE RESPONSE TO COMMENTS IN WRITING.
  
 2.PURSUANT TO SECTION 94-304.(D).(2).B OF THE CITY OF
 WEST PALM BEACH ZONING AND LAND DEVELOPMENT
 REGULATIONS, SWIMMING POOLS SHALL BE ENCLOSED BY A
 FENCE OR SIMILAR STRUCTURE WHICH IS INSTALLED TO
 OBSTRUCT ACCESS WHEN NOT IN USE AND SHALL BE AT LEAST
 FOUR FEET IN HEIGHT ABOVE GRADE.THE PLANS INDICATE
 THE POOL ENCLOSURE WILL BE COMPLETED "BY OTHERS".IS A
 SEPARATE BUILDING PERMIT GOING TO BE SUBMITTED FOR THE
 POOL ENCLOSURE?
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ME.
  
 MARGARITA CRUZ
 ASSOCIATE PLANNER, PLANNING AND ZONING DEPARTMENT
 OFFICE - 561-822-1444