Plan Review Details - Permit 06120634
| Plan Review Stops For Permit 06120634 |
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2008-10-21 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-10-21 |
Time |
19:02 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-10-21 |
Time |
18:46 |
Sent To |
|
|
| Notes |
| 2008-10-21 19:01:58 | ****REVISION #1, DATED 10/10/2008, APPROVED***** | | | | | | REVISED PLAN SHEETS FP-27 & FP-28 WERE STAMPED, IN | | | ITIALED, AND DATED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2008-10-08 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-10-08 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-10-08 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2008-10-08 16:04:28 | *****REVISION DENIED***** | | | | | | 1. THE SUBMITTED REVISED PLAN SHEETS FP-1 & FP-2 DO NOT | | | CORRELATE WITH THE SHEETS FP-1 & FP-2 ON FILE WITH | | | CONSTRUCTION SERVICES DEPARTMENT. IT WOULD APPEAR THAT | | | THE REVISIONS CORRELATE WITH SHEET FP-27 & FP-28 OF THE | | | PERMITTED PLAN SET. | | | | | | 2. IN THE PERMITTED PLAN SET, JOHN OLSEN IS RECORDED AS | | | THE PROFESSIONAL ENGINEER WHEREAS THE REVISED SHEETS | | | HAS ROBERT ANTHONY DUNLEA. PROVIDE DOCUMENTATION THAT | | | THERE HAS BEEN AN ENGINEER OF RECORD CHANGE. | | | | | | 3. IT APPEARS THAT THE PROFESSIONAL ENGINEER'S | | | SIGNATURE HAS BEEN RUBBER STAMPED. PLEASE REFERENCE | | | FLORIDA STATUTE 471.025 AND FLORIDA ADMINISTRATIVE CODE | | | 61G15-23.002 | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-06-13 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-06-13 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-06-13 |
Time |
15:44 |
Sent To |
|
|
| Notes |
| 2007-06-13 17:39:35 | *****APPROVED***** | | | | | | | | | THE SAFETY MARGIN ISSUE WITH STANDPIPE WAS ACCEPTABLE | | | AS PER FIRE MARSHAL MIKE CARSILLO.PLANS WERE STAMPED, | | | INITIALED, AND DATED;READY FOR PERMIT ISSUANCE. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-01-20 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-01-20 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-01-20 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2007-01-20 17:30:36 | *****UNSAT***** | | | | | | | | | 1.THE DATA FOR THE STANPIPE SHOWS A SAFETY MARGIN OF | | | ONLY 4.462 PSI.AS PER WEST PALM BEACH FIRE | | | PREVENTION, A SAFETY MARGIN OF AT LEAST 5.0 IS | | | REQUIRED. | | | | | | *REMINDERS* | | | | | | 2.FIRE SPRINKLER SYSTEM IN CONJUNCTION WITH THE FIRE | | | ALARM SYSTEM IS TO BE FULLY MONITORED. | | | | | | 3. AS PER WEST PALM BEACH FIRE PREVENTION, A WATERFLOW | | | SHALL ACTIVATE A GENERAL FIRE ALARM WITHIN 45 TO 60 | | | SECONDS. | | | | | | 4. COORDINATE WITH THE GENERAL AND/OR FIRE ALARM | | | CONTRACTOR THAT THE DOUBLE CHECK VALVE DETECTOR BE | | | CHAINED AND LOCKED UPON THE COMPLETION OF THE FIRE | | | ALARM FINAL. | | | | | | 5.KNOX LOCKING CAPS ARE REQUIRED FOR NEW FIRE | | | DEPARTMENT CONNECTIONS. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS WHEN RESUBMITTING, | | | INCLUDE A RESPONSE LETTER INDICATING HOW/WHERE EACH | | | ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-10-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-17 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-17 |
Time |
16:13 |
Sent To |
FIRE |
|
| Notes |
| 2008-10-17 16:14:11 | TO "F" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-10-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-02 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-02 |
Time |
11:06 |
Sent To |
FIRE |
|
| Notes |
| 2008-10-02 11:07:06 | TO "F" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-01-20 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-01-20 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-12-27 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2006-12-27 11:32:21 | TO "F" BOX |
|
|
|