Plan Review Details - Permit 06120586
| Plan Review Stops For Permit 06120586 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2007-11-15 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2007-11-15 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2007-11-07 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2007-11-15 10:11:14 | | | | SINCE THIS PARCEL IS VACANT AS OF TODAY AND NO SITE | | | ADDRESS HAS BEEN ISSUED BEFORE PLEASE USE ON THE | | | REVISED SET OF PLANS A NEW SITE ADDRESS AS : | | | 1810 EMBASSY DR , WEST PALM BEACH , FL 33401.ALSO THIS | | | SITE ADDRESS WILL BE USED ALONG WITH THE PARCEL CONTROL | | | NUMBER = 74434317040120042, AS THE COMMON AREA SITE | | | ADDRESS USED FOR PERMITTING AND ANY OTHER PROCESSES | | | PRIOR OF ISSUING THE CO .EACH INDIVIDUAL UNIT WILL | | | RECEIVE A UNIQUE SITE ADDRESS AT THE TIME OF THE | | | PROJECT COMPLETION . | | | IF BUILDING PERMITS WILL BE NEEDED FOR EACH INDIVIDUAL | | | UNIT THEN THE SITE ADDRESS FOR EACH UNIT WILL BE USED. | | | | | | THE RECOMMENDED SITE ADDRESSES FOR THE UNITS STARTING | | | EAST GOING WEST ARE: | | | 1804 ,1806,1808,1812,1814,1816,1818 & 1820EMBASSY DR | | | , WEST PALM BEACH, FL 33401.AN OFFICIAL SITE ADDRESS | | | NOTIFICATION LETTER WILL BE SENT TO THE PROPERTY | | | OWNER. | | | | | | QUESTIONS/COMMENTS PLEASE CALL : | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] | | 2007-11-07 14:17:27 | COPY OF APPL. SENT TO LILI |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2006-12-26 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-12-26 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2007-01-23 |
Time |
07:13 |
Sent To |
|
|
| Notes |
| 2006-12-26 11:18:57 | FOR THESE 8NEW BUILDINGS NEW UNIQUE SITE ADDRESS MUST | | | BE ASSIGNED TO EACH OF THEM. | | | PLEASE PROVIDE THE APPROVED SITE PLAN AND THE SURVEY | | | FOR THIS LOCATION. | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | E-MAIL:[email protected] | | 2006-12-20 16:44:08 | APPL. SHOWS 1800 EMBASSY DR.--COPY OF APPL SENT TO LILI |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2008-07-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-07-09 |
Time |
13:11 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-07-09 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2008-07-09 14:28:46 | BUILDING PLAN REVIEW | | | PERMIT: 06120586 | | | ADD: 1800 EMBASSYDR | | | CONT: E. W. REED, INC. | | | TEL: (305)218-0900 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | JULY- 09/08 | | | | | | 3RDREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3) SEMI- COMPLIED, THIS REVIEW ONLY ONE SOILS REPORT | | | WAS SUBMITTED, TWO ORIGINAL REPORTS WITH ORIGINAL | | | SIGNATURES AND RAISED SEALS ARE REQUIRED.FBC 1802.2.1 | | | QUESTIONABLE SOILS, 1802.2.1 QUESTIONABLE SOIL. WHERE | | | THE SAFE-SUSTAINING POWER OF THE SOIL IS IN DOUBT, OR | | | WHERE A LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED | | | IN THIS CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL | | | REQUIRE THAT THE NECESSARY INVESTIGATION BE MADE. SUCH | | | INVESTIGATION SHALL COMPLY WITH THE PROVISIONS OF | | | SECTIONS 1802.4 THROUGH 1802.6 . | | | | | | 4 ) BUILDING PROVISO: 109.3.10* IMPACT OF CONSTRUCTION. | | | ALL CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL | | | BE PERMORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT | | | THE CONDITION OF ADJACENT PROPERTY, UNLESS SUCH | | | ACTIVITY IS PERMITTED TO AFFECT SAID PROPERTY PURSUANT | | | TO A CONSENT BY THE APPLICABLE PROPERTY OWNER, UNDER | | | TERMS & CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY | | | OWNER.THIS INCLUDES | | | BUT IS NOT LIMITED TO THE CONTROL OF DUST, NOISE, WATER | | | OR DRAINAGE RUN-OFF, DEBRIS, AND THE STORAGE OF | | | CONSTRUCTION MATERIALS. NEW CONSTRUCTION ACTIVITY SHALL | | | NOT ADVERSELY IMPACT HISTORIC SURFACE WATER DRAINAGE | | | FLOWS SERVING ADJACENT PROPERTIES, & MAY REQUIRE | | | SPECIAL DRAINAGE DESIGN COMPLYING WITH ENGINEERING | | | STANDARDS TO PRESERVE THE POSITIVE PATTERNS OF THE | | | AFFECTED SITES. ACCORDINGLY, DEVELOPERS, CONTRACTORS, | | | AND OWNERS OF ALL NEW RESIDENTIAL DEVELOPMENT, | | | INCLUDING ADDITIONS, POOLS, PATIOS, DRIVEWAYS, DECKS, | | | OR SIMILAR ITEMS, ON EXISTING PROPERTIES RESULTING IN A | | | DECREASE IN EXCESS OF 800SQ FT OF | | | PERMEABLE LAND AREA ON ANY PARCELL SHALL AS A PERMIT | | | CONDITION, PROVIDE A PROFESSIONALLY PREPARED DRAINAGE | | | PLAN CLEARLY INDICATING COMPLIANCE WITH THIS PARAGRAPH. | | | UPON COMPLETION OF THE IMPROVEMENT, A CERTIFICATE FROM | | | A LICENSED ENGINEER SHALL BE SUBMITTED TO THE INSPECTOR | | | IN ORDER TO RECEIVE APPROVAL OF THE FINAL INSPECTION. | | | | | | 5 )BUILDING PROVISO: 109.3.10.1 HURICANE PROTECTION. IT | | | SHALL BE UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION | | | RELATED MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE | | | OR OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 | | | HRS. AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS SHALL BE | | | EITHER | | | REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN SUCH A | | | MANNER AS TO MINIMIZE THE DANGER OF SUCH CONSTRUCTION | | | MATERIALS, EQUIPMENT AND DEBRIS CAUSING DAMAGE TO | | | PERSONS OR PROPERTY FROM HIGH | | | WINDS. ANY PERSONS WHO FAILS TO COMPLY TO REMOVE OR | | | SECURE THE CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS | | | WITHIN 24 HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED | | | SHALL BE SUBJECT TO A FINE NOT TO | | | EXCEED $500.00. IN ADDITION TO THE ABOVE, A LICENSED | | | CONTRACTOR WHO VIOLATES THIS SECTION SHALL BE SUBJECT | | | TO DISCIPLINE PURSUANT TO SECTION 113 OF THIS CHAPTER. | | | | | | 6-15) COMPLIED. | | | | | | | | | 16)THIRD REQUEST, PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 ARE REQUIRED | | | TO COMPLY WITH THE FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH SUBMITTED WITH A | | | COVER SHEET THAT LISTS THE PRODUCT IDENTITY NUMBER FROM | | | THE STATE. IF THE PRODUCT DOES NOT HAVE STATEWIDE | | | APPROVAL, SUBMIT AN APPLICATION FOR LOCAL PRODUCT | | | APPROVAL OR SITE SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | HAVE FLORIDA APPROVAL: | | | PGT SLIDINGGLASS DOORS NOA 07-0607.02 | | | PGT MULLIONS NOA 06-01125.06 | | | PGT SH-700NOA 07-0322.06 | | | PGT HORIZONTAL ROLLERNOA 07-0815.09 | | | PGT PW-701 FIXED NOA 07-0418.06 | | | CLOPAY SECTIONAL DOORS NOA 05-0316.01 | | | POLYFOAM NOA 06-0201.02EAGLE ROOFING PRODUCTS | | | GAF MATERIALS BUILT UP ROOF | | | | | | 17)FL BLD CODE 1609.1.4: COMPONENTS & CLADDING, | | | PROVIDE 2 COPIES(3 IF THRESHOLD OR RESIDENT INSPECTOR) | | | OF PRODUCT TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | | | | C) EXTERIOR WALL LOUVERS | | | D) TRUSS ANCHORS | | | E) BUILT UP ROOF SYSTEMS PRPODUCT APPROVAL SUBMITTED | | | IS FOR INSULATED TYPE DECK SYSTEMS! | | | THIS ROOF IS MISSING OR NOT IN | | | COMPLIANCE WITH THE FOLLOW ITEMS: | | | | | | X___ CONTRACTOR FAILED TO INDICATE WHICH | | | SYSTEM TO BE USED. | | | | | | X___ THE SYSTEM PROVIDED HAS A LOW | | | PRESSURE FOR ZONE ___ . | | | | | | X___ THE SYSTEM PROVIDED STATES | | | LIMITATION# 7, SHOULD THE FASTENER | | | RESISTANCE BE LESS THAN THAT | | | REQUIRED, AS DETERMINED BY THE | | | BUILDING OFFICIAL, A REVISED | | | FASTENER SPACING, PREPARED , SIGNED | | | AND SEALED BY A FLORIDA REGISTERED | | | PROFESSIONAL ENGINEER, REGISTERED | | | ARCHITECT OR REGISTERED ROOF | | | CONSULTANT MAY BE SUBMITTED. | | | | | | X___THE SYSTEM PROVIDED INDICATES | | | LIMITATION# 9, NO ENHANCED | | | FASTENING ALLOWED. | | | | | | 18-21) COMPLIED | | | | | | 22-25) COMPLIED. | | | | | | 26)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 27)THE NEW ENERGY CALCS ARE NOT DESIGNED FOR THIS | | | STRUCTURE, | | | A)THEY ARE INDICATED TO BE FOR A 2 UNIT STURCTURE | | | WITH ONLY 6 BEDROOMS. | | | B) CONDITIONED SPACE INDICATES FLOOR AREA 4238 THE | | | FIRST FLOOR ITSELF HAS 12,472 SQ FT. | | | C) RAISED WOOD FLOOR ENERGY CALCS INDICATE A R=19 WHERE | | | AS SHEET A10 DETAIL 4/4 THE CEILING INDICATES R=11 | | | D) FRAMED WALLS STEEL PLAANS DO NOT INDICATE ANY R | | | VALUE | | | CALCULATIONS FOR DOORS AND WINDOWS DO NOT INDICATE THE | | | AMOUNT OF GLAZED UNITS IN WINDOWS AND GLAZED DOORS | | | E) THE DOOR COUNT FOR ADJACEENT SPACES AS WELL AS | | | EXTERIOR DOORS ALSO DOES NOT INDICATE THE CORECT AMOUNT | | | OF OPENINGS FOR THE 8 UNIT STRUCTURE. | | | | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-11-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-11-30 |
Time |
16:37 |
Rev Time |
4.44 |
| Received By |
jwitmer |
Date |
2007-11-30 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2007-11-30 16:43:57 | BUILDING PLAN REVIEW | | | PERMIT: 06120586 | | | ADD: 1800 EMBASSYDR | | | CONT: E. W. REED, INC. | | | TEL: (305)218-0900 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | NOV. 30,2007 | | | | | | 2NDREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3)FBC 1802.2.1 QUESTIONABLE SOILS, 1802.2.1 | | | QUESTIONABLE SOIL. WHERE THE SAFE-SUSTAINING POWER OF | | | THE SOIL IS IN DOUBT, OR WHERE A LOAD-BEARING VALUE | | | SUPERIOR TO THAT SPECIFIED IN THIS CODE IS CLAIMED, THE | | | BUILDING OFFICIAL SHALL REQUIRE THAT THE NECESSARY | | | INVESTIGATION BE MADE. SUCH INVESTIGATION SHALL COMPLY | | | WITH THE PROVISIONS OF SECTIONS 1802.4 THROUGH 1802.6 | | | . | | | | | | 4 ) BUILDING PROVISO: 109.3.10* IMPACT OF CONSTRUCTION. | | | ALL CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL | | | BE PERMORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT | | | THE CONDITION OF ADJACENT PROPERTY, UNLESS SUCH | | | ACTIVITY IS PERMITTED TO AFFECT SAID PROPERTY PURSUANT | | | TO A CONSENT BY THE APPLICABLE PROPERTY OWNER, UNDER | | | TERMS & CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY | | | OWNER.THIS INCLUDES | | | BUT IS NOT LIMITED TO THE CONTROL OF DUST, NOISE, WATER | | | OR DRAINAGE RUN-OFF, DEBRIS, AND THE STORAGE OF | | | CONSTRUCTION MATERIALS. NEW CONSTRUCTION ACTIVITY SHALL | | | NOT ADVERSELY IMPACT HISTORIC SURFACE WATER DRAINAGE | | | FLOWS SERVING ADJACENT PROPERTIES, & MAY REQUIRE | | | SPECIAL DRAINAGE DESIGN COMPLYING WITH ENGINEERING | | | STANDARDS TO PRESERVE THE POSITIVE PATTERNS OF THE | | | AFFECTED SITES. ACCORDINGLY, DEVELOPERS, CONTRACTORS, | | | AND OWNERS OF ALL NEW RESIDENTIAL DEVELOPMENT, | | | INCLUDING ADDITIONS, POOLS, PATIOS, DRIVEWAYS, DECKS, | | | OR SIMILAR ITEMS, ON EXISTING PROPERTIES RESULTING IN A | | | DECREASE IN EXCESS OF 800SQ FT OF | | | PERMEABLE LAND AREA ON ANY PARCELL SHALL AS A PERMIT | | | CONDITION, PROVIDE A PROFESSIONALLY PREPARED DRAINAGE | | | PLAN CLEARLY INDICATING COMPLIANCE WITH THIS PARAGRAPH. | | | UPON COMPLETION OF THE IMPROVEMENT, A CERTIFICATE FROM | | | A LICENSED ENGINEER SHALL BE SUBMITTED TO THE INSPECTOR | | | IN ORDER TO RECEIVE APPROVAL OF THE FINAL INSPECTION. | | | | | | 5 )BUILDING PROVISO: 109.3.10.1 HURICANE PROTECTION. IT | | | SHALL BE UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION | | | RELATED MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE | | | OR OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 | | | HRS. AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS SHALL BE | | | EITHER | | | REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN SUCH A | | | MANNER AS TO MINIMIZE THE DANGER OF SUCH CONSTRUCTION | | | MATERIALS, EQUIPMENT AND DEBRIS CAUSING DAMAGE TO | | | PERSONS OR PROPERTY FROM HIGH | | | WINDS. ANY PERSONS WHO FAILS TO COMPLY TO REMOVE OR | | | SECURE THE CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS | | | WITHIN 24 HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED | | | SHALL BE SUBJECT TO A FINE NOT TO | | | EXCEED $500.00. IN ADDITION TO THE ABOVE, A LICENSED | | | CONTRACTOR WHO VIOLATES THIS SECTION SHALL BE SUBJECT | | | TO DISCIPLINE PURSUANT TO SECTION 113 OF THIS CHAPTER. | | | | | | 6) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | 7-15) COMPLIED. | | | | | | | | | 16) PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE STATE. IF THE | | | PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT AN | | | APPLICATION FOR LOCAL PRODUCT APPROVAL OR SITE SPECIFIC | | | FORM PER RULE 9B-72. SEE ATTACHMENT. | | | WWW.FLORIDABUILDING.ORG | | | | | | 17)FL BLD CODE 1609.1.4: COMPONENTS & CLADDING, | | | PROVIDE 2 COPIES(3 IF THRESHOLD OR RESIDENT INSPECTOR) | | | OF PRODUCT TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) WINDOWS: | | | CASEMENT | | | HORIZONTAL ROLLERS | | | MULLIONS | | | B) DOORS: | | | EXTERIOR HOLLOW CORE METAL DOORS | | | SLIDING GLASS DOORS | | | SECTIONAL GARAGE DOORS | | | C) EXTERIOR WALL LOUVERS | | | D) TRUSS ANCHORS | | | E) ROOFING ASSEMBLIES | | | BUILT UP OR MODIFIED | | | ROOF TILE UNDERLAYMENTS | | | ROOF TILE | | | ROOF TILE ADHESIVES | | | THIS ROOF IS MISSING OR NOT IN | | | COMPLIANCE WITH THE FOLLOW ITEMS: | | | | | | X___ CONTRACTOR DID NOT PROVIDE THE MEAN | | | | | | ROOF HEIGHT. | | | | | | ___ CONTRACTOR DID NOT INDICATE THE ROOF | | | PITCH. | | | | | | X___ CONTRACTOR FAILED TO INDICATE WHICH | | | SYSTEM TO BE USED. | | | | | | X___ THE SYSTEM PROVIDED HAS A LOW | | | PRESSURE FOR ZONE ___ . | | | | | | X___ THE SYSTEM PROVIDED STATES | | | LIMITATION# 7, SHOULD THE FASTENER | | | RESISTANCE BE LESS THAN THAT | | | REQUIRED, AS DETERMINED BY THE | | | BUILDING OFFICIAL, A REVISED | | | FASTENER SPACING, PREPARED , SIGNED | | | AND SEALED BY A FLORIDA REGISTERED | | | PROFESSIONAL ENGINEER, REGISTERED | | | ARCHITECT OR REGISTERED ROOF | | | CONSULTANT MAY BE SUBMITTED. | | | | | | X___THE SYSTEM PROVIDED INDICATES | | | LIMITATION# 9, NO ENHANCED | | | FASTENING ALLOWED. | | | | | | 18-21) COMPLIED | | | | | | 22) 1714.5.5.1 MULLIONS. | | | MULLIONS, OTHER THAN MULLIONS WHICH ARE AN INTEGRAL | | | PART OF A WINDOW OR GLASS DOOR ASSEMBLY TESTED AND | | | LABELED IN ACCORDANCE WITH SECTION 1714.5.2.1 , SHALL | | | BE TESTED BY AN APPROVED TESTING LABORATORY OR BE | | | ENGINEERED IN ACCORDANCE WITH ACCEPTED ENGINEERING | | | PRACTICE. BOTH METHODS SHALL USE PERFORMANCE CRITERIA | | | CITED IN SECTIONS 1714.5.5.2 , 1714.5.5.3 AND | | | 1714.5.5.4 . | | | | | | 1714.5.5.2 LOAD TRANSFER. | | | MULLIONS SHALL BE DESIGNED TO TRANSFER THE DESIGN | | | PRESSURE LOADS APPLIED BY THE WINDOW AND DOOR | | | ASSEMBLIES TO THE ROUGH OPENING SUBSTRATE. | | | | | | 23-25) COMPLIED. | | | | | | 26)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 27) NEW COMMENT SEE ENERGY CALCULATIONS ON FORM | | | 600A-2001 PLEASE CORRECT TO THE 2004 VERSION. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-01-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-01-23 |
Time |
07:14 |
Rev Time |
5.55 |
| Received By |
jwitmer |
Date |
2007-01-23 |
Time |
07:14 |
Sent To |
|
|
| Notes |
| 2007-01-23 08:05:51 | BUILDING PLAN REVIEW | | | PERMIT: 06120586 | | | ADD: 1800 EMBASSYDR | | | CONT: E. W. REED, INC. | | | TEL: (305)218-0900 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1STREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF | | | THE COURT. | | | NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS | | | NOT ACTUALLY | | | COMMENCED WITHIN 90 DAYS AFTER THE RECORDING THEREOF, | | | SUCH NOTICE | | | IS NULL & VOID. NOTE: 713.13(6)THE POSTING OF THE | | | NOTICE OF COMMENCEMENT | | | AT THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. ) | | | 110.2* W. P. B. ADMINISTRATIVE | | | CODE, INFORMATION THAT IS REQUIRED FOR | | | RECORD KEEPING & FOR CERTIFICATE OF | | | OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6, TABLE 601. | | | SHEET A-1 INDICATES III MISSING "A OR B" | | | D) THE DESIGN OCCUPANT LOAD, SEE 1004. | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | | IS REQUIRED. | | | F) ANY SPECIAL STIPULATIONS & CONDITIONS | | | OF THE BUILDING PERMIT. | | | G ) NUMBER OF UNITS | | | H ) NUMBER OF FLOORS | | | 1 ) NUMBER OF BEDROOMS | | | J ) NUMBER OF ROOMS | | | K ) NUMBER OF BEDROOMS | | | L ) SQ. FT. LIV SPACE/ FL | | | M ) SQ. FT. FOOTPRINT | | | N ) SQ. FT. UNDER ROOF (TOTAL) | | | O ) OCCUPANT LOAD | | | | | | 3)FBC 1802.2.1 QUESTIONABLE SOILS, | | | 1802.2.1 QUESTIONABLE SOIL. | | | WHERE THE SAFE-SUSTAINING POWER OF THE SOIL IS IN | | | DOUBT, OR WHERE A | | | LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED IN THIS | | | CODE IS CLAIMED, | | | THE BUILDING OFFICIAL SHALL REQUIRE THAT THE NECESSARY | | | INVESTIGATION BE MADE. | | | SUCH INVESTIGATION SHALL COMPLY WITH THE PROVISIONS OF | | | SECTIONS | | | 1802.4 THROUGH 1802.6 . | | | | | | 4 ) 109.3.10* IMPACT OF CONSTRUCTION. | | | ALL CONSTRUCTION ACTIVITY REGULATED BY | | | THIS CODE SHALL BE PERMORMED IN A MANNER | | | SO AS NOT TO ADVERSELY IMPACT THE | | | CONDITION OF ADJACENT PROPERTY, UNLESS | | | SUCH ACTIVITY IS PERMITTED TO AFFECT | | | SAID PROPERTY PURSUANT TO A CONSENT BY | | | THE APPLICABLE PROPERTY OWNER, UNDER | | | TERMS & CONDITIONS AGREEABLE TO THE | | | APPLICABLE PROPERTY OWNER.THIS INCLUDES | | | BUT IS NOT LIMITED TO THE CONTROL OF | | | DUST, NOISE, WATER OR DRAINAGE RUN-OFF, | | | DEBRIS, AND THE STORAGE OF CONSTRUCTION | | | MATERIALS. NEW CONSTRUCTION ACTIVITY | | | SHALL NOT ADVERSELY IMPACT HISTORIC | | | SURFACE WATER DRAINAGE FLOWS SERVING | | | ADJACENT PROPERTIES, & MAY REQUIRE | | | SPECIAL DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE | | | POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY, | | | DEVELOPERS, CONTRACTORS, | | | AND OWNERS OF ALL NEW RESIDENTIAL | | | DEVELOPMENT, INCLUDING ADDITIONS, POOLS, | | | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR | | | ITEMS, ON EXISTING PROPERTIES RESULTING | | | IN A DECREASE IN EXCESS OF 800SQ FT OF | | | PERMEABLE LAND AREA ON ANY PARCELL SHALL | | | AS A PERMIT CONDITION, PROVIDE A | | | PROFESSIONALLY PREPARED DRAINAGE PLAN | | | CLEARLY INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE | | | IMPROVEMENT, A CERTIFICATE FROM A | | | LICENSED ENGINEER SHALL BE SUBMITTED TO | | | THE INSPECTOR IN ORDER TO RECEIVE | | | APPROVAL OF THE FINAL INSPECTION. | | | | | | 5 ) 109.3.10.1 HURICANE PROTECTION. | | | IT SHALL BE UNLAWFUL FOR ANY PERSON TO | | | ALLOW CONSTRUCTION RELATED MATERIALS | | | EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR | | | OTHERWISE UNSECURED AT A CONSTRUCTION | | | SITE FROM 24 HRS. AFTER A HURRICANE | | | WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN | | | LIFTED. ALL SUCH CONSTRUCTION MATERIALS, | | | EQUIPMENT AND DEBRIS SHALL BE EITHER | | | REMOVED FROM THE CONSTRUCTION SITE OR | | | SECURED IN SUCH A MANNER AS TO MINIMIZE | | | THE DANGER OF SUCH CONSTRUCTION | | | MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM HIGH | | | WINDS. | | | ANY PERSONS WHO FAILS TO COMPLY TO | | | REMOVE OR SECURE THE CONSTRUCTION | | | MATERIALS EQUIPMENT AND DEBRIS WITHIN | | | 24 HRS AFTER A HURRICANE WATCH HAS BEEN | | | ISSUED SHALL BE SUBJECT TO A FINE NOT TO | | | EXCEED $500.00. | | | IN ADDITION TO THE ABOVE, A LICENSED | | | CONTRACTOR WHO VIOLATES THIS SECTION | | | SHALL BE SUBJECT TO DISCIPLINE PURSUANT | | | TO SECTION 113 OF THIS CHAPTER. | | | | | | 6) WPB ADMIN CODE 106.3* PRODUCT | | | APPROVALS. THOSE PRODUCT WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | 7)SHEET A-3 INDICATES TOWNHOUSE STYLE CONSTRUCTION. | | | NOTE THESE UNITS ARE CLASSIFIED AS A R-2 EITHER CONDOS | | | OR RENTAL UNITS AND WILL REVIEWED AS SUCH. | | | | | | 8) SHEETS A-4- A-5 PLANS INDICATE WINDOWS OVER TUB | | | AREAS IN BOTH CASES NO NOTES ON THE WINDOW SCHEDULE | | | INDICATING A HAZARDOUS LOCATION. | | | 2406.3(5)5.GLAZING IN DOORS AND ENCLOSURES FOR HOT | | | TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND | | | SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL | | | ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED | | | EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1524 MM) | | | ABOVE A STANDING SURFACE. | | | | | | 9) SHEET A-5 PLEASE PROVIDE A SECTION THROUGH POWDER | | | ROOM 102. | | | 1208.2(2) | | | 2.IF ANY ROOM IN A BUILDING HAS A SLOPED CEILING , | | | THE PRESCRIBED CEILING HEIGHT FOR THE ROOM IS REQUIRED | | | IN ONE-HALF THE AREA THEREOF. ANY PORTION OF THE ROOM | | | MEASURING LESS THAN 5 FEET (1524 MM) FROM THE FINISHED | | | FLOOR TO THE CEILING SHALL NOT BE INCLUDED IN ANY | | | COMPUTATION OF THE MINIMUM AREA THEREOF. | | | | | | 10)A-7 INDICATES THE USE OF THE 1& 2 FAMILY | | | RESIDENTIAL CODE WITH CODE SECTIONS R312.1 & R312.2 | | | PLEASE CORRECT THESE UNITS ARE AS STATED R-2 NOT R-3. | | | | | | 11) SHEET A-9 DETAIL"B" PLEASE MAKE NOTE OF THE ASTM | | | C-1063 THE NAILING ON HORIZONTAL FRAMING MEMBERS TO BE | | | AT 4" ON CENTER WITH A MINIMUM OF 1 3/4" NAILING INTO | | | FRAMING MEMBER. | | | | | | 12) SHEET A-9 DETAIL "A" PLEASE PROVIDE CALCULATIONS | | | FOR VENTILATION AND MEETING THE REQUIREMENTS OF : | | | 1203.2 THE NET FREE VENTILATING AREA SHALL NOT BE LESS | | | THAN 1 / 150 OF THE AREA OF THE SPACE VENTILATED, WITH | | | 50 PERCENT OF THE REQUIRED VENTILATING AREA PROVIDED BY | | | VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE | | | TO BE VENTILATED AT LEAST 3 FEET (914 MM) ABOVE EAVE OR | | | CORNICE VENTS WITH THE BALANCE OF THE REQUIRED | | | VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. | | | | | | 13)SHEET A-10 DETAIL # 1 AGAIN MAKES REFRENCE TO THE | | | RESIDENTIAL CODE PLEASE CORRECT, THIS IS A R-2 | | | OCCUPANCY NOT R-3. | | | | | | 14)SHEET A-12 DETAIL# 1 PLEASE REMOVE REFENCE TO THE | | | ONE AND TWO FAMILY RESIDENTIAL CODE ALSO A-13. | | | | | | 15) 1609.1.4 PROTECTION OF OPENINGS. | | | IN WIND-BORNE DEBRIS REGIONS, EXTERIOR | | | GLAZING THAT RECEIVES POSITIVE PRESSURE | | | IN THE LOWER 60 FEET (18.3 M) IN | | | BUILDINGS SHALL BE ASSUMED TO BE | | | OPENINGS AND THE BALANCE OF GLAZED | | | OPENINGS IN THE REST OF THE BUILDING | | | SHALL BE ASSUMED TO BE ZERO UNLESS SUCH | | | GLAZING THAT RECEIVES POSITIVE PRESSURE | | | IS IMPACT RESISTANT OR PROTECTED WITH AN | | | IMPACT RESISTANT COVERING MEETING THE | | | REQUIREMENTS OF SSTD 12, ASTM E 1886 AND | | | ASTM E 1996, OR MIAMI-DADE TAS 201, 202 | | | AND 203 REFERENCED THEREIN AS FOLLOWS: | | | 1.GLAZED OPENINGS LOCATED WITHIN 30 | | | FEET (9.1 M) OF GRADE SHALL MEET THE | | | REQUIREMENTS OF THE LARGE MISSILE TEST. | | | 2.GLAZED OPENINGS LOCATED MORE THAN | | | 30 FEET (9.1 M) ABOVE GRADE SHALL MEET | | | THE PROVISIONS OF THE SMALL MISSILE | | | TEST. | | | | | | 16) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 17)FL BLD CODE 1609.1.4: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) WINDOWS: | | | CASEMENT | | | HORIZONTAL ROLLERS | | | MULLIONS | | | B) DOORS: | | | EXTERIOR HOLLOW CORE METAL DOORS | | | SLIDING GLASS DOORS | | | SECTIONAL GARAGE DOORS | | | C) EXTERIOR WALL LOUVERS | | | D) TRUSS ANCHORS | | | E) ROOFING ASSEMBLIES | | | BUILT UP OR MODIFIED | | | ROOF TILE UNDERLAYMENTS | | | ROOF TILE | | | ROOF TILE ADHESIVES | | | THIS ROOF IS MISSING OR NOT IN | | | COMPLIANCE WITH THE FOLLOW ITEMS: | | | | | | X___ CONTRACTOR DID NOT PROVIDE THE MEAN | | | | | | ROOF HEIGHT. | | | | | | ___ CONTRACTOR DID NOT INDICATE THE ROOF | | | PITCH. | | | | | | X___ CONTRACTOR FAILED TO INDICATE WHICH | | | SYSTEM TO BE USED. | | | | | | X___ THE SYSTEM PROVIDED HAS A LOW | | | PRESSURE FOR ZONE ___ . | | | | | | X___ THE SYSTEM PROVIDED STATES | | | LIMITATION# 7, SHOULD THE FASTENER | | | RESISTANCE BE LESS THAN THAT | | | REQUIRED, AS DETERMINED BY THE | | | BUILDING OFFICIAL, A REVISED | | | FASTENER SPACING, PREPARED , SIGNED | | | AND SEALED BY A FLORIDA REGISTERED | | | PROFESSIONAL ENGINEER, REGISTERED | | | ARCHITECT OR REGISTERED ROOF | | | CONSULTANT MAY BE SUBMITTED. | | | | | | X___THE SYSTEM PROVIDED INDICATES | | | LIMITATION# 9, NO ENHANCED | | | FASTENING ALLOWED. | | | | | | 18) PLEASE PROVIDE INFORMATION AS TO TYPE OF MATERIAL | | | TO BE USED ON RIDGE AND HIP | | | BOARDS AND ATTACHMENT METHOD. CONCRETE TILE 1507.3: | | | 1507.3.7 ATTACHMENT. | | | CLAY AND CONCRETE ROOF TILES SHALL BE FASTENED IN | | | ACCORDANCE WITH SECTION 1609 OR IN ACCORDANCE WITH | | | FRSA/RTI INSTALLATION MANUAL, 4TH EDITION. | | | | | | 1507.3.8 APPLICATION. | | | TILE SHALL BE APPLIED ACCORDING TO THE MANUFACTURER?S | | | INSTALLATION INSTRUCTIONS OR RECOMMENDATIONS OF THE | | | FRSA/RTI 07320, 4TH EDITION. | | | | | | 19) 1503.3.6 PROTECTION AGAINST DECAY & | | | TERMITES. CONDENSATE LINES & ROOF DOWN | | | SPOUTS SHALL DISCHARGE AT LEAST 1 FT. | | | AWAY FROM THE STRUCTURE SIDEWALL, | | | WHETHER BY UNDERGROUND PIPING, TAIL EX- | | | TENSIONS, OR SPLASH BLOCKS. | | | | | | 20) S- SHEETS DO NOT PROVIDE BUCK DETAILS FOR WINDOWS, | | | DOORS OR GARAGE SECTIONAL DOOR. | | | 1714.5.4.1 ANCHORING REQUIREMENTS. | | | WINDOW AND DOOR ASSEMBLIES SHALL BE ANCHORED IN | | | ACCORDANCE WITH THE PUBLISHED MANUFACTURER?S | | | RECOMMENDATIONS TO ACHIEVE THE DESIGN PRESSURE | | | SPECIFIED. SUBSTITUTE ANCHORING SYSTEMS USED FOR | | | SUBSTRATES NOT SPECIFIED BY THE FENESTRATION | | | MANUFACTURER SHALL PROVIDE EQUAL OR GREATER ANCHORING | | | PERFORMANCE AS DEMONSTRATED BY ACCEPTED ENGINEERING | | | PRACTICE. | | | | | | 21) 1714.5.4.2 MASONRY, CONCRETE OR OTHER STRUCTURAL | | | SUBSTRATE. | | | WHERE THE WOOD SHIM OR BUCK THICKNESS IS LESS THAN 1 1 | | | / 2 INCHES (38 MM), WINDOW AND DOOR ASSEMBLIES SHALL BE | | | ANCHORED THROUGH THE MAIN FRAME OR BY JAMB CLIP OR | | | SUBFRAME SYSTEM, IN ACCORDANCE WITH THE MANUFACTURER?S | | | PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE | | | SECURELY FASTENED DIRECTLY INTO THE MASONRY, CONCRETE | | | OR OTHER STRUCTURAL SUBSTRATE MATERIAL. UNLESS | | | OTHERWISE TESTED, BUCKS SHALL EXTEND BEYOND THE | | | INTERIOR FACE OF THE WINDOW OR DOOR FRAME SUCH THAT | | | FULL SUPPORT OF THE FRAME IS PROVIDED. SHIMS SHALL BE | | | MADE FROM MATERIALS CAPABLE OF SUSTAINING APPLICABLE | | | LOADS, LOCATED AND APPLIED IN A THICKNESS CAPABLE OF | | | SUSTAINING APPLICABLE LOADS. ANCHORS SHALL BE PROVIDED | | | TO TRANSFER LOAD FROM THE WINDOW OR DOOR FRAME TO THE | | | ROUGH OPENING SUBSTRATE. | | | WHERE THE WOOD BUCK THICKNESS IS 1 1 / 2 INCHES (38 MM) | | | OR GREATER, THE BUCK SHALL BE SECURELY FASTENED TO | | | TRANSFER LOAD TO THE MASONRY, CONCRETE OR OTHER | | | STRUCTURAL SUBTRATE AND THE BUCK SHALL EXTEND BEYOND | | | THE INTERIOR FACE OF THE WINDOW OR DOOR FRAME. WINDOW | | | AND DOOR ASSEMBLIES SHALL BE ANCHORED THROUGH THE MAIN | | | FRAME OR BY JAMB CLIP OR SUBFRAME SYSTEM OR THROUGH THE | | | FLANGE TO THE SECURED WOOD BUCK IN ACCORDANCE WITH THE | | | MANUFACTURER?S PUBLISHED INSTALLATION INSTRUCTIONS. | | | UNLESS OTHERWISE TESTED, BUCKS SHALL EXTEND BEYOND THE | | | INTERIOR FACE OF THE WINDOW OR DOOR FRAME SUCH THAT | | | FULL SUPPORT OF THE FRAME IS PROVIDED. SHIMS SHALL BE | | | MADE FROM MATERIALS CAPABLE OF SUSTAINING APPLICABLE | | | LOADS, LOCATED AND APPLIED IN A THICKNESS CAPABLE OF | | | SUSTAINING APPLICABLE LOADS. ANCHORS SHALL BE PROVIDED | | | TO TRANSFER LOAD FROM THE WINDOW OR DOOR FRAME ASSEMBLY | | | TO THE SECURED WOOD BUCK | | | | | | 22) 1714.5.5.1 MULLIONS. | | | MULLIONS, OTHER THAN MULLIONS WHICH ARE AN INTEGRAL | | | PART OF A WINDOW OR GLASS DOOR ASSEMBLY TESTED AND | | | LABELED IN ACCORDANCE WITH SECTION 1714.5.2.1 , SHALL | | | BE TESTED BY AN APPROVED TESTING LABORATORY OR BE | | | ENGINEERED IN ACCORDANCE WITH ACCEPTED ENGINEERING | | | PRACTICE. BOTH METHODS SHALL USE PERFORMANCE CRITERIA | | | CITED IN SECTIONS 1714.5.5.2 , 1714.5.5.3 AND | | | 1714.5.5.4 . | | | | | | 1714.5.5.2 LOAD TRANSFER. | | | MULLIONS SHALL BE DESIGNED TO TRANSFER THE DESIGN | | | PRESSURE LOADS APPLIED BY THE WINDOW AND DOOR | | | ASSEMBLIES TO THE ROUGH OPENING SUBSTRATE. | | | | | | 23) S-4 PLEASE UPDATE ACI-318 AND ACI- 530 TO THE | | | REFRENCED STANDARDS IN CHAPTER 35. | | | | | | 24)SHEET E-1 VS M-1 2ND FLOOR HAL 201 BE AWARE OF THE | | | CLOSENESS OF SMOKE DETECTORS TO RETURN AIR VENTS. | | | | | | 25) SHEET A-5 INDICATES AN OPTION BEDROOM# 4, WHERE AS | | | BOTH THE MECHANICAL AND ELECTRICAL ARE MISSING THIS | | | OPTION. PLEASE PROVIDE AND SMOKE DETECTORS. | | | | | | 26)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-07-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-07-24 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-07-24 |
Time |
09:19 |
Sent To |
PC |
|
| Notes |
| 2008-07-24 09:20:02 | ** DENIED REVIEW ** | | | | | | ** THERE ARE COMMENTS WHICH COME FROM PREVIOUS REVIEW | | | COMMENTS HOWEVER THEY ARE NEW BASED ON INFORMATION NOW | | | ON PLANS. | | | THERE ARE ALSO SOME REPEAT COMMENTS | | | | | | 1) NOTE: PLEASE SEE THE NEW SERVICE ENTRANCE CONDUCTORS | | | WHICH ARE NOW BEING SHOWN ARE NOT COMPLETE. NO CONDUIT | | | SIZE IS SHOWN. THE REVIEW FOR CODE COMPLIANCE FOR | | | CONDUIT FILL CAN NOT BE DONE. (TABLE 9) | | | | | | 2) NOTE: PLEASE ALSO SEE THE NEW SERVICE ENTRANCE | | | CONDUCTORS DO NOT MEET THE MINIMUM SIZE REQUIRED PER | | | 240.4B FOR DEVICES OVER 800AMPS. | | | PLEASE ADJUST. 310.16 | | | | | | 3) NOTE: PLEASE SUPPLY AIC RATING OF THE 1200AMP MAIN | | | AS PREVIOUSLY REQUESTED. | | | 110.9. | | | PLANS NOTE AIC RATING OF PANELS AND BREAKERS HOWEVER | | | DOES NOT INDICATE MAIN RATING. | | | | | | 4) NOTE: PLEASE SEE UNIT B ON E-3 WHICH IS SHOWING SD | | | FOR SMOKE DETECTOR. THIS CAN BE REDLINED AND DOES NOT | | | NEED TO REPRINT SHEETS AT THIS TIME. | | | | | | | | | | | | IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-11-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-29 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-28 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2007-11-29 12:29:06 | ** DENIED 2ND REVIEW ** | | | | | | ** PLEASE KNOW AS STATED ON PREVIOUS REVIEW AS THERE | | | WERE CHANGES WHICH WERE NEEDED AND ITEMS NOT SUBMITTED | | | ON PREVIOUS PLANS THERE MAY BE NEW COMMENTS GENERATED | | | ON THE 2ND REVIEW. | | | ** PLEASE SEE THESE ARE COMMENTS BASED ON THE PLANS | | | SUBMITTED AND SOME ITEMS FROM PREVIOUS REVIEW WHICH | | | STILL NEED TO BE ADDRESSED ALONG WITH NEW COMMENTS. | | | | | | | | | 1) NOTE: PLEASE SEE AS MENTIONED ON PREVIOUS REVIEW | | | NOTE # 27 THE ADDRESS WAS YET TO BE DETERMINED AND LOOK | | | FOR COMMENTS FROM THE ADDRESSING REVIEWER. | | | PLEASE SEE THE NEW ADDRESS OF 1810 EMBASSY DR WAS | | | GENERATED. AS THESE ARE NOT FEE SIMPLE TOWNHOUSES AND | | | PLANS HAVE HAD CHANGES INDICATING THIS, PLEASE ADJUST | | | ADDRESS IN TITLE BLOCKS TO 1810. | | | | | | 2) NOTE: PLEASE SEE AS PREVIOUSLY MENTIONED IN NOTE #2, | | | PLEASE BE SURE ALL SMOKE ALARMS MEET NFPA-72 11.8.3 | | | WHICH REQUIRES ALL SMOKE DEVICES TO BE A MINIMUM OF 3FT | | | FROM BATH DOORS AND 20FT FROM COOKING APPLIANCES. THERE | | | ARE EXCEPTIONS FOR COOKING APPLIANCES IF DEVICE IS OF A | | | PHOTO-ELECTRIC TYPE AND/OR RESETTING TYPE. | | | PLEASE SEE UNIT A MASTER BEDROOM FOR EXAMPLE. | | | | | | 3) NOTE: PLEASE SEE PREVIOUS NOTES # 3, #4 AND #10. | | | PLEASE SEE THERE ARE STILL SOME AREAS WHERE SOME GFI | | | RECEPTACLES DO NOT MEET 210.52C1-5 AND 210.8A6. | | | PLEASE SEE E-2 UNIT A, ISLAND FOR ONE EXAMPLE. (GFI) | | | PLEASE SEE E-2 UNIT A,PENINSULAR AND SEPARATE SPACES | | | AND COUNTER SPACE FOR EXAMPLE. | | | | | | 4) NOTE: PLEASE SEE PREVIOUS NOTE #8 FOR LISTING OF ALL | | | RELEVANT CODES WHICH WERE REQUIRED TO BE ADJUSTED AND | | | PLACED ON PLANS. | | | RESPONSE WAS THAT ALL CODES WERE ADDED TO A AND SHEET | | | E-4, WHICH WAS OK AND CORRECT HOWEVER PLEASE SEE E-2 | | | AND E-3 AS THE 2002 NFPA-70 ( NEC) IS STILL REFERENCED | | | IN NOTES. | | | PLEASE ADJUST. | | | | | | 5) NOTE: PLEASE KNOW AS MENTIONED IN PREVIOUS REVIEW | | | NOTES #11,12 ETC THE SERVICE WAS CHANGED FROM PREVIOUS | | | PLANS AND NEW COMMENTS ARE NOW BEING MADE. | | | PLEASE SEE THE FOLLOWING COMMENTS FOR SERVICE RISER: | | | NOTES 6-11 | | | | | | 6) NOTE: PLEASE SEE MISSING CONDUITS FROM FPL TO | | | SERVICE. AS FPL DOES NOT INSTALL THESE CONDUITS, THESE | | | FALL UNDER THE NEC AND SIZING REQUIREMENTS FOR | | | SERVICE. | | | ***IMPORTANT: PLEASE VERIFY WITH THE FPL SERVICE | | | PLANNER THAT THE SERVICE ENTRANCE CONDUCTORS ARE | | | ACTUALLY GOING TO BE PULLED IN AND INSTALLED BY FPL. | | | ALMOST ALL PROJECTS WHERE AN ON-SITE TRANSFORMER IS | | | BEING INSTALLED BY FPL THE CONDUITS AND CONDUCTORS | | | INCLUDING SERVICE ENTRANCE CONDUCTORS FROM SERVICE TO | | | TRANSFORMER ARE BEING REQUIRED TO BE INSTALLED BY THE | | | ELECTRICAL CONTRACTOR AND WILL BE THE RESPONSIBILITY OF | | | THE OWNER. PLEASE KNOW AS MENTIONED ABOVE, IF CONDUITS | | | AND CONDUCTORS ARE INSTALLED BY ELECTRICAL CONTRACTOR, | | | THESE WILL BOTH FALL UNDER THE NEC AND ARE NEEDED TO BE | | | SHOWN ON PLANS/SERVICE RISER. | | | PLEASE OBTAIN LETTER FROM THE SERVICE PLANNER IF THESE | | | WILL BE INSTALLED BY FPL. | | | FBC 106.3.5.1.2, 106.1.2 | | | | | | 7) NOTE: PLEASE SEE THE CONDUIT SIZE IS MISSING FOR | | | FEEDERS TO UNITS AND ARE UNABLE TO REVIEW AT THIS TIME | | | FOR CODE COMPLIANCE. PLEASE SEE CONDUIT FILL TABLE IN | | | CHAPTER 9 (C). | | | FBC 106.3.5.1.2 | | | | | | 8) NOTE: PLEASE SEE THE CONDUIT FOR HOUSE PANEL IS TOO | | | SMALL FOR CONDUCTORS ARE SHOWN. NO CONSIDERATION HAS | | | BEEN GIVEN FOR LENGTH AT THIS TIME. | | | PLEASE ADJUST SIZE OF CONDUIT. | | | FBC 106.3.5.1.2 | | | | | | 9) NOTE: PLEASE SEE THE SERVICE METER CENTER IS BEING | | | SHOWN AS 1160AMPS WHICH IS NOT A STANDARD SIZE PER | | | 240.6. PLEASE PROVIDE THE STANDARD SIZE OF EQUIPMENT. | | | FBC106.3.5.1.2 | | | | | | 10) PLEASE SEE THE METER CENTER DOES NOT INDICATE ANY | | | MAIN AS REQUIRED PER 230.70, 230.71. | | | FBC 106.3.5.1.2 | | | | | | 11) PLEASE SEE NO AIC RATING(S) FOR MAINS AND BREAKERS | | | ARE INDICATED AS REQUIRED.110.9, FBC 106.1.2, | | | 106.3.5.1.2 | | | | | | 12) NOTE: PLEASE SEE PREVIOUS REVIEW NOTE # 23 | | | REQUESTED COMPLETED LOAD CALCULATIONS WHICH WERE | | | SUBMITTED HOWEVER PLEASE SEE 422.13 AS THE WATER | | | HEATERS ARE NOW CONSIDERED A CONTINUOUS LOAD UNDER THE | | | NEW CODE AND IS REQUIRED TO BE FIGURED AT 125%. | | | PLEASE ADJUST CALCULATIONS. | | | FBC 106.3.5.1.2 | | | | | | 13) NOTE: PLEASE SEE PREVIOUS NOTES #14 AND #28 AS | | | ROOMS ARE AREAS NEEDED TO BE SHOWN ON PLANS, | | | SPECIFICALLY DINING AREAS/ROOMS. PLEASE SEE AS | | | PREVIOUSLY NOTED THE DINING AREAS AND/OR ROOMS SHALL BE | | | ON ONE OR MORE OF THE SMALL APPLIANCE CIRCUITS. | | | PLEASE SEE E-3 UNIT B OPTION AS THE DINING RECEPTACLES | | | ARE BEING SHOWN ON A GENERAL LIGHTING CIRCUIT WHICH IS | | | NOT PERMITTED. | | | | | | 14) NOTE: PLEASE SEE THE LOCATION OF THE ELECTRICAL | | | SERVICE IS OF CONCERN. PLEASE SEE BASED ON THE SIZE OF | | | SUCH EQUIPMENT AND BASED ON THE SCALE AND LOCATION AS | | | SHOWN ON PLANS THERE SEEMS THERE WILL BE AN ISSUE FOR | | | MINIMUM WORKING CLEARANCES AND PROTECTION OF EQUIPMENT. | | | AS THE LOCATION HAS A DRIVEWAY/PARKING AREA IS RIGHT IN | | | FRONT OF EQUIPMENT, NOT ONLY WILL THE EQUIPMENT REQUIRE | | | MINIMUM CLEARANCES, BUT ALSO PROTECTION BY BOLLARDS TO | | | PREVENT DAMAGE. PLEASE PROVIDE MINIMUM CLEARANCES, | | | BOLLARD DETAIL, SITE DETAIL INCLUDED WITH THE ELEVATION | | | DETAIL. | | | PLEASE SEE BASED ON SCALE THE EQUIPMENT AS THIS IS VERY | | | LARGE IN NATURE MAY PROTRUDE INTO DRIVE AREA. | | | 110.26 | | | | | | 15) NOTE: PLEASE PROVIDE INFORMATION AND ELECTRICAL | | | PLANS FOR HOUSE PANEL AND EQUIPMENT. | | | PLEASE SEE THAT NO PANEL SCHEDULE WAS SUBMITTED WITH | | | OVER CURRENT PROTECTION, CIRCUITS, CONDUCTORS ETC. | | | PLEASE SEE NO ELECTRICAL PLANS WERE SUBMITTED SHOWING | | | LOCATION OF ELECTRICAL ON HOUSE PANEL. | | | FBC 106.3.5.1.2 | | | NEC 2005 240.4, 310.16 ETC | | | | | | 16) NOTE: PLEASE SEE 408.4, PLEASE PROVIDE MORE | | | SPECIFIC DESIGNATIONS ON CIRCUITS AS SHOWN ON PANEL | | | SCHEDULES. | | | PLEASE SEE THE USE OF * GENERAL LIGHTING* SHOULD SHOW | | | OR INDICATE THE ROOMS AND AREAS IN WHICH THESE CIRCUITS | | | FEED. FOR EXAMPLE: BEDROOM #2 LIGHTING, LIVING ROOM | | | LTS/RECEPTS ETC. | | | THIS WAS A CHANGE IN THE 2005 CODE WHICH REQUIRES MORE | | | SPECIFIC DETAILS. | | | PLEASE ALSO SEE THE CIRCUITING AS SHOWN FOR UNIT *B* | | | INDICATES CIRCUITING TO PANEL *A*. | | | THESE DESIGNATIONS SEEM TO BE A MISPRINT AND SHOULD BE | | | *B-3*, B27, B21 ETC. | | | 408.4. | | | FBC 106.3.5.1.2, 106.5 | | | | | | 17) NOTE: PLEASE SHOW ON SITE ELECTRICAL PLANS THE | | | LOCATIONS OF ALL CONDENSING UNITS, DISCONNECTS AND GFI | | | RECEPTACLES. | | | 440.11, 110.26, 210.63, 210.8 | | | FBC 106.1.2 | | | | | | 18) NOTE: PLEASE SEE PREVIOUS NOTE #24 FOR 210.52. | | | THERE IS STILL SOME RECEPTACLES MISSING AND NOT LOCATED | | | AS REQUIRED PER 210.52. | | | PLEASE SEE SOME OF THESE ARE REDLINED ON ONE OF THE SET | | | OF PLANS. | | | PLEASE SEE MISSING RECEPTACLES WITHIN 6FT OF DOORWAY | | | OPENINGS. | | | PLEASE ALSO KNOW THAT PERMANENT RAIL AREAS ARE | | | CONSIDERED WALL SPACE. | | | | | | 19) NOTE: PLEASE SEE NOTICE TO FS 553.80(2)(B) WITH | | | RESPECT TO REPEAT COMMENTS FOR CODE COMPLIANCE. THIS IS | | | ONLY A NOTICE GIVEN AT THIS TIME. | | | | | | ** ONCE AGAIN AS THERE ARE SOME ITEMS NOT YET SUBMITTED | | | FOR REVIEW THERE MAY BE NEW COMMENTS GENERATED ON THE | | | NEXT REVIEW AS THESE ITEMS CAN NOT BE REVIEWED AT THIS | | | TIME. | | | | | | *** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-01-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-01-12 |
Time |
18:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-01-12 |
Time |
17:18 |
Sent To |
|
|
| Notes |
| 2007-01-12 18:52:49 | ** UNSAT ** | | | | | | ** PLEASE SEE THESE ARE COMMENTS BASED ON THE PLANS | | | SUBMITTED. PLEASE SEE THAT THERE MAY BE COMMENTS ON THE | | | NEXT REVIEW WHICH MAY BE NEW AS SOME INFORMATION AS | | | SHOWN ON THESE PLANS WILL BE CHANGING SYSTEMS. | | | | | | ** PLEASE SEE ANY REFERENCES IN PLAN REVIEW NOTES TO | | | CHAPTER 1 OF THE FBC AS THAT WHICH IS ADOPTED BY THE | | | CITY OF WEST PALM BEACH. | | | | | | 1) NOTE: PLEASE SEE PLANS ARE BEING SUBMITTED AND | | | LABELED AS TOWNHOUSE UNITS, HOWEVER PLEASE SEE IF THESE | | | ARE INDEED FEE SIMPLE "TOWNHOUSES" AS PER FBC | | | DEFINITIONS, PLEASE SEE REQUIREMENTS OF THE FBC AND | | | ELECTRICAL CODE WHICH WOULD CHANGE MANY ITEMS IN THE | | | DESIGN AND PLEASE KNOW SEPARATE PERMIT APPLICATIONS, | | | PLANS AND FEES WOULD BE REQUIRED ON EACH FEE SIMPLE | | | TOWNHOUSE. PLEASE SEE AS ALL UNITS ARE CONNECTED BY A | | | COMMON AREA AND ONE BUILDING THIS DOES NOT SEEM | | | POSSIBLE. | | | PLEASE KNOW THE PLANS AS SUBMITTED IS FOR ONE BUILDING | | | AND PLEASE SEE COMMENTS FOR ELECTRICAL SERVICE(S) AS | | | SUBMITTED. | | | | | | PLEASE SEE COMMENTS FROM OTHER TRADES | | | FBC ADMIN SECTION 106.1.2 FOR ADDITIONAL INFORMATION. | | | | | | 2) NOTE: PLEASE SEE NFPA-72 11.8.3 WHICH REQUIRES ALL | | | SMOKE DEVICES TO BE A MINIMUM OF 3FT FROM BATH DOORS | | | AND 20FT FROM COOKING APPLIANCES. THERE ARE EXCEPTIONS | | | FOR COOKING APPLIANCES IF DEVICE IS OF AN PHOTOELECTRIC | | | TYPE AND/OR RESETTING TYPE. | | | | | | 3) NOTE: PLEASE SEE SOME RECEPTACLES SPACED ALONG | | | KITCHEN COUNTER SPACE. IT APPEARS SOME NEED TO BE | | | RELOCATED TO MEET 210.52C1 | | | | | | 4) NOTE: PLEASE SEE ALL RECEPTACLES SERVING KITCHEN | | | COUNTER SPACE SHALL BE SHOWN AS GFI/GFI PROTECTED. | | | 210.8A6. | | | | | | 5) NOTE: PLEASE SEE NO RECEPTACLE BEING SHOWN FOR THE | | | DISPOSAL FOR DISCONNECTING MEANS. | | | 422.31 | | | | | | 6) NOTE: PLEASE CLARIFY THE TYPE FIRE PROTECTION BEING | | | INSTALLED FOR BUILDING. PLEASE SEENFPA-72 11-5.1.1, | | | 11.8.3. PLEASE SEE NFPA-72 DEFINITIONS AS PLANS CALL | | | FOR SD FOR SMOKE DETECTORS THIS IS OK, HOWEVER PLEASE | | | KNOW IF THESE ARE INDEED SMOKE DETECTORS AS DEFINED IN | | | NFPA72, THESE WOULD BE DEVICES WHICH ONLY DETECT AND | | | WOULD SIGNAL TO OTHER ALARM/HORN DEVICES. NO ALARM HORN | | | DEVICES ARE SHOWN. PLEASE INDICATE IF PART OF A FUTURE | | | LV FA SYSTEM. | | | PLEASE KNOW AS PER SECTIONS GIVEN IF THESE ARE INDEED | | | DEVICES WHICH DETECT AND ALSO SOUND AN ALARM, THEN THEY | | | WOULD BE LABELED AS SA FOR SMOKE ALARMS. | | | PLEASE KNOW AS OF OCT 06 IT CAME TO OUR ATTENTION AT | | | THE SOUTHERN SECTION IAEI MEETING FROM NFPA THAT IF | | | UNITS ARE INDEED DEVICES WHICH DETECT AND SOUND AN | | | ALARM, PLANS SHOULD SHOW THEM AS SA'S AND THIS IS NOT | | | NEW CODE. THIS HAS BEEN AN ACCEPTED METHOD IN THE PAST | | | TO SHOW SD FOR BOTH HOWEVER ALL PLANS SINCE OCT 06 | | | SHOULD BE CHANGING IF AND WHERE APPLICABLE. PLEASE SEE | | | SECTIONS OF THE FBC AS STATED ON PLANS WHICH ACTUALLY | | | CONTAIN THE WORDING OF SMOKE ALARMS IN THE FBC. | | | IF PART OF A LV FIRE/SECURITY SYSTEM PLEASE INDICATE AS | | | SUCH. PLEASE SHOW DEVICES THEN FOR SOUNDING. PLEASE | | | ALSO SEE MISSING SMOKE DETECTION/ SMOKE ALARM DEVICE IN | | | UNIT "C" FIRST FLOOR. | | | | | | 7) NOTE: PLEASE SEE FBC 2004 13-103.1.1.1 WHICH | | | REQUIRES THE TYPE OF RECESSED LIGHTS TO BE INSTALLED. | | | PLEASE NOTE ON PLANS ACCORDINGLY AND INDICATE | | | FIXTURES. | | | | | | 8) NOTE: PLEASE BE SURE PLANS REFLECT THE CODES IN | | | WHICH THE DESIGN IS UNDER AND PERMITTED UNDER. PLEASE | | | LIST THE FOLLOWING AT A MINIMUM FOR ELECTRICAL SHEETS | | | AND ARCHITECTURAL SHEETS. | | | 2005 NFPA-70 (NEC), 2002-NFPA-72 NATIONAL FIRE ALARM | | | CODE | | | ** PLEASE KNOW FOR INFORMATIONAL PURPOSE, AS OF | | | DECEMBER 8TH, 2006 THE STATE OF FLORIDA ADOPTED THE | | | 2006 REVISIONS TO THE 2004 FBC AND THE 2005 NFPA-70( | | | NEC). AS THIS PROJECT WAS SUBMITTED FOR PERMIT BEFORE | | | THIS DATE, THIS PROJECT IS UNDER THE PREVIOUS CODES AS | | | STATED ABOVE. PLEASE SEE THAT THERE ARE STRUCTURAL | | | DESIGN CHANGES ALSO DONE UNDER THE NEW 2006 REVISIONS | | | TO THE FBC. PLEASE SEE BUILDING REVIEW NOTES FOR DESIGN | | | PRESSURES ETC. (NOTED FOR INFORMATION ONLY) | | | | | | 9) NOTE: PLEASE SEE THE HWH IS BEING SHOWN WITH | | | RECEPTACLE FOR THE CONNECTION OF THIS UNIT WHICH IS NOT | | | PERMITTED. PLAN NEEDS TO SHOW A DISCONNECT/J-BOX IF | | | BREAKER IS GOING TO BE USED TO MEET THE CODE. PLEASE | | | SEE EXCEPTIONS FOR WITHIN SITE. | | | 422.30, 4220.31 | | | | | | 10) NOTE: PLEASE SEE MISSING GFI RECEPTS FOR KITCHEN | | | PENINSULAR PER 210.52C3, 210.8A6 | | | | | | 11) NOTE: PLEASE SEE THE FOLLOWING COMMENT, HOWEVER | | | PLEASE STILL SEE RISER DOES NOT INDICATE ANY MAIN | | | DISCONNECT FOR SERVICE. THE FOLLOWING COMMENT AND HOW | | | PLANS WILL BE SUBMITTED WILL DICTATE WHAT TYPE OF | | | SERVICE AND HOW MUCH WILL CHANGE; HOWEVER IN EITHER | | | CASE MAINS ARE REQUIRED. | | | 230.70, 230.71, 240.4 ETC | | | | | | 12) NOTE: PLEASE SEE AS THIS IS ONE BUILDING; PLEASE | | | SEE 230.2 AS THE PROPOSED SERVICESFOR EACH UNIT ARE | | | NOT GRANTED AS SHOWN ON PLANS. PLEASE REVISE SERVICE | | | RISER DIAGRAM FOR GROUPING OF MAINS INTO ONE SERVICE. | | | PLEASE KNOW IF THESE ARE SUBMITTED AS TRUE | | | TOWNHOUSES/FEE SIMPLE, PROPERTY LINES, SEPARATE PERMIT | | | APPLICATIONS ETC, AND THEN INDIVIDUAL SERVICES TO EACH | | | UNIT MAY BE PERMITTED. THIS WILL CHANGE RISER AS SHOWN | | | OR NOT? | | | PLEASE REVISE RISER DIAGRAM. | | | | | | 13) NOTE: PLEASE SEE RISER AS SHOWN NOW SHOWS AN | | | EQUIPMENT GROUNDING CONDUCTOR FROM THE METER TO THE | | | PANEL. WITHOUT SHOWING MAIN ON RISER IT IS NOT POSSIBLE | | | TO CORRECTLY DETERMINE THE LOCATION OF THE EGC. PLEASE | | | SEE 250.6, 250.24B AS THE EGC IS NOT PERMITTED BEFORE | | | THE FIRST MEANS OF DISCONNECT. | | | | | | 14) NOTE: PLEASE SHOW ALL ROOMS AND AREA DESIGNATIONS | | | ON PLANS. PLEASE COMPLETE ALL CIRCUITING ON PLANS AND | | | CORRELATE WITH THE PANEL SCHEDULES SUBMITTED. PLEASE | | | SEE THERE ARE SOME ITEMS WHICH CAN NOT BE REVIEWED FOR | | | CODE COMPLIANCE AT THIS TIME DUE TO THIS INFORMATION | | | NOT SHOWN. | | | NEC 408.4, 310.16, 240.4 ETC. | | | FBC 106.1.2, 106.3.5.1.2 ADMIN SECTIONS. | | | | | | 15) NOTE: PLEASE SEE 250.66 FOR SIZING OF THE GROUNDING | | | ELECTRODE CONDUCTOR. DEPENDING ON THE SERVICE AND WHAT | | | THE BUILDING FINALLY COMES DOWN TO AND THE SIZE OF THE | | | SERVICE, THIS WILL DETERMINE THE SIZE OF THE GEC. | | | PLEASE SEE THE 150A METER AS SHOWN INDICATES A 1/0? | | | | | | 16) NOTE: PLEASE KNOW BASED ON SOME OF THE CIRCUITING | | | AT THIS TIME NOT BEING SHOWN; PLEASE BE SURE TO SEE | | | 210.12 FOR AFCI PROTECTED CIRCUITS. THIS APPEARS TO BE | | | ADDRESSED, BUT CAN NOT BE CONFIRMED AT THIS TIME. | | | | | | 17) NOTE: PLEASE SEE MISSING THE REQUIRED GFI FOR SOME | | | CONDENSING UNITS PER 210.63, 210.8A3 (UNIT "A"). | | | | | | 23) NOTE: PLEASE SEE SUBMIT COMPLETE LOAD CALCULATIONS | | | FOR SERVICE. 220.84, 220.12, 220.42, 220.44 ETC. PLEASE | | | KNOW DEPENDING ON THE NEW SERVICE AND LOAD, | | | CONSIDERATION OF 230.2 WILL BE REVIEWED, HOWEVER PLEASE | | | KNOW AT THIS TIME THE SINGLE METER/SERVICE FOR EACH IS | | | OK, HOWEVER IF ONE MAIN AND A METER BANK IS INSTALLED | | | FOR MULTI-FAMILY/CONDO SERVICE, THISH WILL REQUIRE | | | CALCULATIONS FOR SUCH. | | | | | | 24) NOTE:PLEASE SEE 210.52 FOR AREAS FOR REQUIRED | | | RECEPTS WHICH ARE MISSING ON PLANS. PLEASE SEE UNIT | | | "A/B" ETC. | | | PLEASE SEE ONE SET OF PLANS ARE REDLINED FOR LOCATIONS | | | WHICH ARE MISSING DEVICES WITHIN 6FT OF DOOR, 2FT OR | | | MORE OF WALL SPACE AND HALLWAYS AS NOTED. | | | | | | 25) NOTE: PLEASE COMPLETE RISER DIAGRAM WITH ALL | | | FEEDERS TO UNITS AND CORRELATE WITH THE OVER CURRENT | | | PROTECTION DEVICES OF THAT FOR EACH UNIT ONCE RISER IS | | | FINALIZED. | | | 215.5, 310.16, 240.4 ETC. | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | 26) NOTE: PLEASE INDICATE THE EQUIPMENT GROUNDING | | | CONDUCTORS FROM MAINS TO EACH UNIT PER 250.122. | | | 250.24B, 250.110, ETC. (WHERE REQUIRED AND | | | APPLICABLE). | | | | | | 27) NOTE: PLEASE SEE THAT THE ADDRESS FOR THIS PROJECT | | | SHALL BE PLACED ON THE TITLE BLOCKS. PLEASE KNOW AT | | | THIS TIME, THIS IS A MULTI-FAMILY SINGLE BUILDING WITH | | | THE ADDRESS OF 1800 EMBASSY DR. PLEASE SEE NOTE FROM | | | ADDRESSING REVIEWER FOR ADDRESS?S ALSO DEPENDING ON HOW | | | THESE ARE BEING PERMITTED AND SUBMITTED. | | | THIS IS NOT AND HAS NOT BEEN SUBMITTED AS TOWNHOUSES, | | | OR CONDO'S. | | | FAC 61G15-23.002, FAC 61G1-16.004 | | | | | | 28) NOTE: PLEASE CLARIFY DINING ROOM/AREA ON PLANS SO | | | THAT ONCE CIRCUITING IS SHOWN COMPLIANCE WITH 210.52B1, | | | 210.11C1 AND 220.52 CAN BE VERIFIED. | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
F |
Date |
2008-07-11 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2008-07-11 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2008-07-11 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2008-07-11 13:32:34 | PLEASE PROVIDE FOLLOWING INFO: | | | | | | 1. FIRST FLOOR ELEVATION, CENTER LINE OF ROAD , | | | SIDEWALK ELEVATION MUST MEET FL BLDG CODE, PLEASE SHOW | | | ON THE DRAWINGS. | | | YOUR RESPOSEFOR REV 2 NOT ENOUGH,YOU NEED TO PROVE | | | IN A DOCUMENTS/CALCULATIONS THATYOU HAVE CONSIDERED | | | FLOOD ZONE OF THISAREA,&5, 10, 25, 100 YEARRAIN | | | FLOOD CRITERIA, AND CROWN OF THE ROAD HAVE BEEN | | | CONSIDERED. FIRST FLOOR ELEVATION SHOULD BE HIGHER THAN | | | CROWN OF THE ROAD BY ATLEAST 1 FOOT. ORIGINAL PLANS | | | WERE APROVED IN 1970'S PER YOUR LETTER BUT THAT IS, | | | TOO LONG TIME TO CONTINUE IN EFFECT, NORMALLYITIS A | | | 5 YEAR PERMIT LIMIT. IF YOU DO NOT BUILD IN 5 YEARS YOU | | | NEED TO RE APPLY UNLESS YOU HAVE A LETTER ALLOWING YOU | | | TO BUILD ANY TIME. | | | | | | OUR RESPONSE FOR REV 3FOR YOUR LETTER OF 5/28/08 FROM | | | DOUG WINTER COMP., INC.WE NEED A RESPONSE FROM MOCK | | | ROOS FOR YOUR LETTER OF 5/13/08 TO MOCK ROOS. | | | | | | 2. PLEASE PROVIDE A COPY OF SFWMD PERMIT, GEO TECH | | | REPORT., | | | OUR RESPONSE FOR REV 2 :AGAIN,SFWMD PERMIT IS GOOD | | | FOR FIVE YEARS. | | | | | | OUR RESPONSE FOR REV 3 FOR YOUR LETTER 5/28/08: SINCE | | | MOCK ROOS IS REVIEWING STORM WATER CALS, LET MOCK ROOS | | | DECIDE. | | | | | | | | | 3.PLEASE SHOW STORM WATER CALCULATIONS, WHAT CRITERIA | | | YOU ASSUMEDFOR RUNOFF CAL.,, LIKE 1" OVER ENTIRE SITE | | | OR2.5"CRITERIA, ? PLEASE SHOW ON DRAWINGPERVIOUS | | | AREA, LIKE GREEN, LAKES, ETC,IMPERVIOUS AREA. | | | | | | OUR RESPONSEFOR REV 2:AGAIN YOU ARE SAYING IN YOUR | | | LETTER THAT IT IS PART OF THE MASTER PLAN OF 1970'S. | | | WELL,1970 IS WAY TOO BACK.PLEASE PROVIDE THE STORM | | | WATER QUALITY CALCULATIONS. WE NEED EX-FILTRATION | | | TRENCH CALCULATION ALSO. | | | | | | OUR RESPONSE FOR REV 3 FOR YOUR LETTER 5/28/08: WE NEED | | | STORM WATER QUALITY CALS.MOCK-ROOS REVIEWS IT. YOU | | | NEED TO SUBMIT STORM WATER QUALITY CALS TO 1000 45TH | | | STREET ENGINEERING, SO THEY COULD GIVE IT TO MOCK ROOS | | | FOR REVIEW.WE DO NOT ISSUE PERMIT UNTIL 1000 45TH | | | ST. ENGINEERING APPROVES. | | | | | | 4WATER & SEWER PLANS MUST BE APPROVED FROM 45TH | | | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED. | | | | | | OUR RESPONSEFOR REV 3: MANNY G. PUT ARED STAMP WITH | | | HIS SIGNATURE WHEN HE APPROVES YOUR DRAWINGS. WE DID | | | NOT SEE STAMPS ON YOUR DRAWINGS YET. | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2007-12-04 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-12-04 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-12-04 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2007-12-04 11:15:35 | PLEASE PROVIDE FOLLOWING INFO: | | | | | | 1. FIRST FLOOR ELEVATION, CENTER LINE OF ROAD , | | | SIDEWALK ELEVATION MUST MEET FL BLDG CODE, PLEASE SHOW | | | ON THE DRAWINGS. | | | YOUR RESPOSE NOT ENOUGH,YOU NEED TO PROVE IN A | | | DOCUMENTS/CALCULATIONS THATYOU HAVE CONSIDERED FLOOD | | | ZONE OF THISAREA,&5, 10, 25, 100 YEARRAIN FLOOD | | | CRITERIA, AND CROWN OF THE ROAD HAVE BEEN CONSIDERED. | | | FIRST FLOOR ELEVATION SHOULD BE HIGHER THAN CROWN OF | | | THE ROAD BY ATLEAST 1 FOOT. ORIGINAL PLANS WERE APROVED | | | IN 1970'S PER YOUR LETTER BUT THAT IS,TOO LONG TIME | | | TO CONTINUE IN EFFECT, NORMALLYITIS A5 YEAR | | | PERMIT LIMIT. IF YOU DO NOT BUILD IN 5 YEARS YOU NEED | | | TO RE APPLY UNLESS YOU HAVE A LETTER ALLOWING YOU TO | | | BUILD ANY TIME,WE DO NOT THINK SO. | | | | | | 2. PLEASE PROVIDE A COPY OF SFWMD PERMIT, GEO TECH | | | REPORT., | | | OUR RESPONSE:AGAIN,SFWMD PERMIT IS GOOD FOR FIVE | | | YEARS. | | | | | | 3.PLEASE SHOW STORM WATER CALCULATIONS, WHAT CRITERIA | | | YOU ASSUMEDFOR RUNOFF CAL.,, LIKE 1" OVER ENTIRE SITE | | | OR2.5"CRITERIA, ? PLEASE SHOW ON DRAWINGPERVIOUS | | | AREA, LIKE GREEN, LAKES, ETC,IMPERVIOUS AREA. | | | OUR RESPONSE:AGAIN YOU ARE SAYING IN YOUR LETTER THAT | | | IT IS PART OF THE MASTER PLAN OF 1970'S.WELL,1970 | | | IS WAY TOO BACK.PLEASE PROVIDE THE STORM WATER | | | QUALITY CALCULATIONS. WE NEED EX-FILTRATION TRENCH | | | CALCULATION ALSO. | | | | | | 4. PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR SITE | | | SO, WE CANSEE THE BEST PIPE TO CONNECT WITH THE STORM | | | WATERFROM ALL OTHER STORM WATER PIPES. PLEASE SHOW | | | DETAIL OF THE CONTROL STRUCTURES WITH ELEVATIONS, | | | NOTCHES, BLEEDING ELEVATION, ETC | | | | | | 5. POLLUTION PREVENTION DETAILS,CLOTHES USED FOR SILT | | | ETC., PLANS SHOWING SILT FENCE AROUND THE SITE | | | OUR RESPONSE: YOU NEED SILT FENCE ON SOUTH SIDE AND | | | EAST SIDE ALSO. SILT FENCE SHOULD BE ALL AROUND THE | | | PROPERTY LINE PER FDEP. | | | | | | 6. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH | | | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED. | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2007-01-25 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-01-25 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-01-25 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2007-01-25 15:21:06 | PLEASE PROVIDE FOLLOWING INFO: | | | | | | 1. PLEASE SHOW STANDARDS NOTES OF CITY OF WPB ON | | | DRAWINGSFOR SIDEWALK WIDTH , ITS SLOPE, DRIVEWAY, | | | PARKING, HANDICAP PARKING, PAINTPER CITY CODES ETC.,, | | | MUST MEET PER ADA,,ETC., | | | 2. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE | | | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION | | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | | 3. FIRST FLOOR ELEVATION, CENTER LINE OF ROAD , | | | SIDEWALK ELEVATION MUST MEET FL BLDG CODE, PLEASE SHOW | | | ON THE DRAWINGS. | | | 4. PLEASE PROVIDE A COPY OF SFWMD PERMIT, GEO TECH | | | REPORT., | | | 5.PLEASE SHOW STORM WATER CALCULATIONS, WHAT CRITERIA | | | YOU ASSUMEDFOR RUNOFF CAL.,, LIKE 1" OVER ENTIRE SITE | | | OR2.5"CRITERIA, ?PERVIOUS AREA, LIKE GREEN, | | | LAKES, ETC,IMPERVIOUS AREA CAL., | | | 6. WHAT IS THE SITE AREA, YOU ARE DEVELOPING FOR THIS | | | PROJECT ONLY ? SO, WE CAN CHECK PERVIOUS, IMPERVIOUS | | | CAL. | | | 7. HOW YOU CONNECT TO THE STORM WATER PIPES IN YOUR | | | SITE? ITS DETAILS.PLEASE SHOW ALL STORM WATER PIPES | | | AROUND YOUR SITE SO, WE CANSEE THE BEST PIPE TO | | | CONNECT WITH THE STORM WATERFROM ALL OTHER STORM | | | WATER PIPES. PLEASE SHOW DETAIL OF THE CONTROL | | | STRUCTURES WITH ELEVATIONS, NOTCHES, BLEEDING | | | ELEVATION, ETC DID YOU USE EXFILTRATION TRENCH ? | | | 8. POLLUTION PREVENTION DETAILS,CLOTHES USED FOR SILT | | | ETC., PLANS SHOWING SILT FENCE AROUND THE SITE | | | 9. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH | | | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED 11. | | | ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND YOUR | | | SITE FOR STORM WATER DRAIN. | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-07-22 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-07-22 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-07-22 |
Time |
15:18 |
Sent To |
E |
|
| Notes |
| 2008-07-22 15:28:28 | *****PROVISO***** | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE | | | BEEN ADDRESSED;PLAN SHEETS A-1 AND A-6 WERE STAMPED, | | | INITIALED, AND DATED.PLAN SHEETS E-2 AND E-3 TO BE | | | FIRE-STAMPED WHEN THE ELECTRICAL EXAMINER HAS BEEN | | | SATISFIED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-12-12 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-12-12 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-12-12 |
Time |
12:20 |
Sent To |
|
|
| Notes |
| 2007-12-12 12:31:12 | *****UNSAT***** | | | | | | THE FOLLOWING COMMENTS (OF 13) FROM THE PREVIOUS FIRE | | | PLAN REVIEW STILL NEED TO BE ADDRESSED: | | | | | | | | | 01.THE COMPLETE ADDRESS OF WHERE THE SCOPE OF WORK | | | WILL BE CONDUCTED SHALL BE IN THE TITLE BLOCK OF EACH | | | SUBMITTED PLAN SHEET. THE NUMBER 1810 (NOT 1800) SHOWS | | | UP IN OUR SYSTEM AS THE NUMERICAL FOR THIS PROJECT | | | SITE.LILI URSU MAY BE CONTACTED AT 561-822-1239 FOR | | | ADDRESS MATTERS. | | | | | | 05.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | ACKNOWLEDGE THE COMMENT ON AN APPROPIATE PLAN SHEET; | | | PLEASE BE ADVISED THAT NFPA 241 INCLUDES NEW | | | CONSTRUCTION. | | | | | | 06.THE CONSTRUCTION OPERATION AND /OR THE STOCKING OF | | | NEW BUILDING MATERIALS & SUPPLIES SHALL NOT INTERFERE | | | OR HINDER EMERGENCY ACCESS RESPONSE TO THE SAID | | | PROPERTY OR THE VICINITY THEREOF.ADD TO GENERAL | | | NOTES, SHEET A-0 | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH COMMENT WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-02-15 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-02-15 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-02-15 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2007-02-15 15:01:02 | *****DENIED***** | | | | | | | | | 01.THE COMPLETE ADDRESS OF WHERE THE SCOPE OF WORK | | | WILL BE CONDUCTED SHALL BE IN THE TITLE BLOCK OF EACH | | | SUBMITTED PLAN SHEET. | | | | | | 02.PLEASE SUBMIT THE FOLLOWING INFORMATION: | | | *CONSTRUCTION TYPE* OCCUPANCY TYPE*BUILDING HEIGHT | | | * BUILDING SQUARE FOOTAGE *INTERIOR FINISH | | | CLASSIFICATIONS * ANY OTHER PERTINENT INFORMATION TO | | | ASSIST IN THE PLAN REVIEW. | | | | | | 03.WILL THE STRUCTURE HAVE A FIRE ALARM AND/OR FIRE | | | SPRINKLER SYSTEM?IF SO, PROVIDE A LAYOUT OF THE FIRE | | | PROTECTION SYSTEM(S) FOR REVIEW. | | | | | | 04.NFPA 101 - 2003 EDITION AND THE FORIDA FIRE | | | PREVENTION CODE - 2004 EDITION SHALL BE REFERENCED. | | | | | | 05.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 06.THE CONSTRUCTION OPERATION AND /OR THE STOCKING OF | | | NEW BUILDING MATERIALS & SUPPLIES SHALL NOT INTERFERE | | | OR HINDER EMERGENCY ACCESS RESPONSE TO THE SAID | | | PROPERTY OR THE VICINITY THEREOF. | | | | | | 07.THE SITE PLAN (SHEET A-1) DOES NOT SHOW ANY FIRE | | | HYDRANTS.INDICATE THE LOCATION OF FIRE HYDRANT(S) | | | WITHIN 300 FEET OF THE STRUCTURE.PLEASE BE ADVISED | | | THAT AN ADDITIONAL HYDRANT MAY BE REQUIRED IF THIS | | | DISTANCE IS GREATER THAN 500 FEET. | | | | | | 08IT APPEARS THAT THIS STRUCTURE WILL BE SETBACK | | | FROM EMBASSY DRIVE.IF THIS TRUE, AS PER WEST PALM | | | BEACH CODE, A MONUMENT SIGN OR MARQUEE SHALL POST THE | | | ADDRESS RANGE FOR THE DEVELOPMENT.THESE NUMBERS SHALL | | | BE NO LESS THAN 6" IN HEIGHT AND NO LESS THAN 1" IN | | | WIDTH. | | | | | | 09.PLEASE INDICATE ON PLANS THAT ALL FIRE RATED DOORS | | | (103,108,111) SHALL BE EQUIPPED WITH SELF CLOSING | | | DEVICES AND SHALL POSTIVELY CLOSE UPON RELEASE. | | | | | | 10.ON THE APPROPIATE EXTERIOR ELEVATION SHEET, | | | DISPLAY THE ADDRESS FOR THE UNITS. | | | | | | 11.PLEASE BE ADVISED THAT SMOKE DETECTORS (SD) ARE | | | TIED INTO A FIRE ALARM SYSTEM.SMOKE ALARMS (SA), ON | | | THE OTHER HAND, RECEIVE THEIR OPERATING POWER FROM THE | | | BUILDING ELECTRICAL SYSTEM.SEE ELECTRICAL SHEETS. | | | | | | 12.SMOKE ALARMS ARE TO BE ARRANGED SO THAT THE | | | OPERATION OF ANY SMOKE ALARMSHALL CAUSE THE ALARM IN | | | ALL SMOKE ALARMS WITHIN THE DWELLING UNIT TO SOUND. | | | | | | 13.A FIRE HYDRANT IS SHOWN ON SHEET LP-1 BUT NOT ON | | | SHEET A-1.IS THIS AN EXISTING HYDRANT OR A PROPOSED | | | HYDRANT TO BE INSTALLED? | | | | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH COMMENT WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-06-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-20 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-20 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2008-06-23 09:52:24 | TO "COMM" BD#62 | | 2008-06-20 10:52:32 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-11-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-07 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-07 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2007-11-21 11:06:03 | TO "COMM" BD#7/PLANS ON RACK | | 2007-11-07 14:13:44 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-02-15 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-02-15 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-12-20 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2007-01-11 10:12:57 | TO "COMM" BD#31 | | 2006-12-20 16:43:20 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-06-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-06-24 |
Time |
13:58 |
Rev Time |
1.30 |
| Received By |
tgordon |
Date |
2008-06-24 |
Time |
13:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-11-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-27 |
Time |
08:14 |
Rev Time |
1.15 |
| Received By |
tgordon |
Date |
2007-11-27 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2007-11-27 08:23:55 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) ENERGY CALCULATIONS NEED TO BE ON FORM 600A-04R, PER | | | 2004 FBC 13-600.3.A, (12-8-06 REVISION). NOT 2001. | | | | | | 2 ENERGY CALCULATIONS NEED TO BE SIGNED BY THE PREPARER | | | AND THE OWNER/AGENT, PER 2004 FBC 13-600.3.ABC.2. | | | | | | 3) COULD NOT FIND THE A/C SYSTEMS LISTED ON THE | | | MECHANICAL PLANS (PAGE M-1 & M-2) ON THE ARI DIRECTORY | | | WEB SITE. PLEASE SUBMIT THE ARI REFERENCE NUMBER OR A | | | COPY OF THE ARI PERFORMANCE CERTIFICATE, SEE 2004 FBC | | | 13-607.1.ABC.3.1.1. | | | | | | 4) LAST REVIEW 1-22-07 NOTE #7 STATED THE RETURN AIR | | | TRANSFER DUCTS WERE UNDER SIZED, THIS WAS IN REFERENCE | | | TO THE FLEX DUCTS NOT THE GRILLS, PLEASE BE ADVISED IF | | | THEY REMAIN THE SAME A PRESSURE DIFFERENTIAL TEST WILL | | | BE DONE AT FINAL INSPECTION AND CORRECTIONS MAY BE | | | REQUIRED, SEE 2004 FBC/R M1602.4. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-01-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-01-22 |
Time |
08:51 |
Rev Time |
1.15 |
| Received By |
tgordon |
Date |
2007-01-22 |
Time |
08:51 |
Sent To |
P |
|
| Notes |
| 2007-01-22 09:15:11 | *** DENIED *** | | | 1) SEE ELECTRICAL REVIEW NOTE #1, PLEASE CORRECT. | | | | | | 2) SEE ENERGY CALCULATIONS TOTAL COOLING BTU'S 264,000, | | | AND PLANS ARE SHOWING 8 UNITS AT 59,000 = 472,000 TOTAL | | | BTU'S, THE TWO MUST COINCIDE, PLEASE CORRECT. | | | | | | 3) PLEASE SUBMIT MANUAL J CALCULATIONS FOR MODEL "A" | | | ONE UNIT ONLY 2081 SQUARE FEET, AND MODEL "B" ONE UNIT | | | ONLY 2157 SQUARE FEET. | | | | | | 4) FORTH BEDROOM OPTION IS MISSING FROM MECHANICAL | | | PLANS PAGE M-2, PLEASE CORRECT. | | | | | | 5) SEE PAGE M-2 FIRST FLOOR PLAN POWER ROOM #102, | | | EXHAUST UP TO ATTIC, EXHAUST AIR MUST DISCHARGE TO THE | | | OUTDOORS, SEE 2004 FBC/M 501.2. PLEASE CORRECT. | | | | | | 6) SEE PAGE M-1 FIRST FLOOR PLAN, THE CLOTHES DRYER | | | VENT MAY NOT DISCHARGE ON TO THE A/C CONDENSER UNIT, | | | SEE 2004 FBC/M 401.5.2. PLEASE CORRECT. | | | | | | 7) RETURN AIR TRANSFER DUCTS TO ALL ROOM ARE | | | UNDER-SIZED, BALANCED RETURN AIR MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-07-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-07-21 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-07-21 |
Time |
10:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-12-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-12-03 |
Time |
18:49 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-12-03 |
Time |
18:49 |
Sent To |
|
|
| Notes |
| 2007-12-03 18:53:36 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | 1. OK | | | 2. OK | | | 3. OK | | | 4. OK | | | | | | 5. SUBMIT WATER RISER DIAGRAMS FOR EACH UNIT TYPE. SHOW | | | ALL PIPE SIZES, VALVES AND WATER HAMMER ARRESTORS | | | REQUIRED BY SECTION 604.9. (WASH MACHINES, DISH | | | WASHERS, & ICE MAKERS). WATER HAMMER ARRESTORS SHALL BE | | | LOCATED IN AN "EFFECTIVE RANGE", (NOT IN THE CEILING), | | | PER PDI-WH 201 AND MANUF. INSTALLATION INSTRUCTIONS. | | | SECTION 106.3.5.1.3(3)(13). | | | ****RESPONSE NOTED, BUT THE RISER FOR BOTH UNITS "A" | | | &"B" BOTH SHOW THE WATER LINE AS IT ENTERS INSIDE THE | | | BUILDING CHANGING TO 1/2" THEN CHANGES TO 1" TO THE | | | HEATER ETC. PLEASE CLARIFY. ALSO SHUT OFF VALVES SHALL | | | BE INSTALL ON THE SUPPLY LINE TO EACH HOSE BIBB. | | | SECTION 606.2(2). | | | | | | 6. OK | | | 7. OK - INFORMATIONAL | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-02-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-02-06 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-02-06 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2007-02-06 10:30:31 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | 1. SHT P-1 UNIT A SANITARY RISER DIAGRAM. THE AUTOMATIC | | | CLOTHES WASHER FIXTURE SHALL CONNECT TO A BRANCH DRAIN | | | OR DRAINAGE STACK A MINIMUM OF 3" IN DIAMETER. SECTION | | | 406.3.--THE FITTING SHOWN AT THE TOP OF THE STACK | | | IS NOT APPROVED. THERE SHOULD BE A WYE DOWNSTREAM AND A | | | SWEEP ABOVE THE WYE TO CONNECT THE THREE BATHROOM | | | GROUPS. (SEE RED LINE EXAMPLE ON ONE SET OF PLANS). | | | | | | 2. SHT P-1 WATER HEATER DETAIL, IF A BACKFLOW PREVENTOR | | | IS REQUIRED, THEN THERMAL EXPANSION CONTROL WILL BE | | | REQUIRED PER SECTION 607.3.2. | | | | | | 3. SHT P-2 UNIT B SANITARY RISER DIAGRAM. THE AUTOMATIC | | | CLOTHES WASHER FIXTURE SHALL CONNECT TO A BRANCH DRAIN | | | A MINIMUM OF 3" IN DIAMETER. SECTION 406.3.--THE | | | TUB AND THE WATER CLOSET AT THE BASE OF THE STACK ARE | | | NOT VENTED. SECTION 901.2.1.--ONLY THE FIXTURES | | | WITHIN THE BATHROOM GROUP SHALL CONNECT TO THE | | | WET-VENTED HORIZONTAL BRANCH DRAIN. ANY ADDITIONAL | | | FIXTURES SHALL DISCHARGE DOWNSTREAM OF THE WET VENT. | | | SECTION 909.1. THE SECOND FLOOR MASTER BATH & BATH #2 | | | SHALL CONNECT DOWNSTREAM OF THE BATHROOM FIXTURES IN | | | OPTIONAL BATHROOM #4. THE AAV FOR OPTIONAL BATHROOM #4 | | | SHALL BE INSTALLED FOR THE BRANCH LINE FOR THE BATHROOM | | | ONLY. AS SHOWN IT IS VENTING ONLY THE LAV. (SEE RED | | | LINE EXAMPLES ON ONE SET OF PLANS). | | | | | | 4. MORE INFORMATION IS REQUIRED. ARE THE UNITS TO BE | | | INDIVIDUALLY METERED? IF THERE IS A SINGLE WATER METER, | | | AN RPZV BACKFLOW WILL BE REQUIRED. SECTION 608.13.2. | | | PLEASE CLARIFY. SECTION 106.1.1. | | | | | | 5. SUBMIT WATER RISER DIAGRAMS FOR EACH UNIT TYPE. SHOW | | | ALL PIPE SIZES, VALVES AND WATER HAMMER ARRESTORS | | | REQUIRED BY SECTION 604.9. (WASH MACHINES, DISH | | | WASHERS, & ICE MAKERS). WATER HAMMER ARRESTORS SHALL BE | | | LOCATED IN AN "EFFECTIVE RANGE", (NOT IN THE CEILING), | | | PER PDI-WH 201 AND MANUF. INSTALLATION INSTRUCTIONS. | | | SECTION 106.3.5.1.3(3)(13) | | | | | | 6. SUBMIT PLUMBING FLOOR PLANS FOR EACH UNIT SHOWING | | | THE SANITARY, WATER, P/T DISCHARGE LINE, EMERGENCY W/H | | | PAN DRAIN LINE, THE WATER SERVICE, AND SANITARY SEWER | | | LOCATIONS. SECTION 106.3.5.1.3(4)(10). | | | | | | 7. AN IRRIGATION PERMIT AND PLANS ARE REQUIRED. SECTION | | | 105.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2008-07-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2008-06-26 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2008-07-03 08:38:35 | ***FAILED*** | | | | | | 1) SITE PLAN APPROVAL HAS EXPIRED.A NEW APPLICATION | | | SHALL BE SUBMITTED FOR AN INFORMAL SITE PLAN REVIEW TO | | | THE CITY'S PLANNING AND ZONING DEPARTMENT.AS SHOWN IN | | | THE ATTACHED LETTER TO MR. JON SCHMIDT, DATED JUNE 20, | | | 2008, NO EXTENSION MAY BE GRANTED AS THE APPLICATION | | | HAS ALREADY BEEN ISSUED A PREVIOUS EXTENSION, AND HAS | | | EXPIRED. | | | | | | 2) TWO (2) COPIES OF A CURRENT/ACCURATE SURVEY WAS NOT | | | SUBMITTED WITH THE PACKAGE. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-12-18 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-12-18 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-12-18 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2007-12-18 15:35:53 | ***FAILED*** | | | | | | 1) SITE PLAN APPROVAL HAS EXPIRED.A NEW APPLICATION | | | SHALL BE SUBMITTED FOR AN INFORMAL SITE PLAN REVIEW TO | | | THE CITY'S PLANNING AND ZONING DEPARTMENT. | | | | | | 2) TWO (2) COPIES OF A CURRENT/ACCURATE SURVEY WAS NOT | | | SUBMITTED WITH THE PACKAGE. | | | | | | 3) PLEASE REMOVE ONE OF THE SITE PLANS EACH CONTAIN | | | DIFFERENT INFORMATION.IT WOULD PROBABLY BE BEST TO | | | COPY THE SITE DATA TABLE, ETC. ONTO SHEE A-1 AND REMOVE | | | SHEET SP-1. | | | | | | 4) THE CIVIL PLANS DO NOT MATCH THE SITE/LANDSCAPE | | | PLANS.THE CIVIL PLANS SHOW A SIDEWALK CONNECTING THE | | | HC SPACE TO THE END UNIT. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-01-25 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-01-25 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-01-25 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2007-01-25 15:09:29 | ***FAILED*** | | | | | | 1)PLEASE CLARIFY AS TO WHETHER OR NOT THE TWO (2) | | | SURFACE PARKING SPACES WILL BE PROVIDED NEAR EMBASSY | | | DRIVE.THESE SPACES ARE SHOWN ON THE LANDSCAPE PLANS, | | | BUT NOT ON THE SITE PLAN, NOR THE CIVIL PLANS.PLEASE | | | ENSURE THAT ALL PLANS ARE CONSISTENT. | | | | | | 2) PLEASE NOTE ON THE PLANS THAT THE FENCE WILL BE | | | PROVIDED UNDER A SEPARATE PERMIT.....AS A SEPARATE | | | PERMIT WILL BE REQUIRED.PLEASE PROVIDE A DETAIL | | | ELEVATION OF THE PROPOSED FENCE.UPON APPLYING FOR THE | | | FENCE PERMIT, A COMPLETED AND SIGNED EASEMENT RELEASE | | | FORM SHALL BE PROVIDED FROM THE CITY'S PUBLIC UTILITIES | | | DEPARTMENT.AS THE FENCE IS PROPOSED TO CROSS AN | | | EASEMENT, EASEMENT RELEASES SHALL BE PROVIDED FROM ALL | | | OF THE UTILITY COMPANIES (ADELPHIA, FP&L, FLORIDA | | | PUBLIC UTILITIES, AND BELLSOUTH). | | | | | | 3) A DATA TABLE SHALL BE PROVIDED ON THE SITE PLAN | | | PROVIDING ALL THE NECESSARY CODE COMPLIANT INFORMATION. | | | PLEASE CONTACT ME FOR A LIST OF THE NECESSARY DATA. | | | | | | 4) PLEASE DESIGNATE THE SHADE TREES AND FLOWERING TREES | | | WITHIN THE PLANT LIST. | | | | | | 5) THE PLANT LIST DOES NOT CORRESPOND TO THE LANDSCAPE | | | CALCULATION TABLE AS FAR AS THE NUMBER OF TREES/SHRUBS, | | | ETC. | | | | | | 6) NOT ALL PAVEMENT IS SHOWN ON THE CIVIL PLANS (I.E. | | | SIDEWALKS, PATIOS, ETC.). | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT JOHN ROACH, SENIOR | | | PLANNER, AT (561) 822-1435. |
|
|
|