| Plan Review Stops For Permit 06120570 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2007-11-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-11-08 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-11-08 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2007-11-08 13:25:06 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBEXISTING BUILDING CODE 2004 | | | FBC R RESIDENTIAL 2004 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | | | | FROM PREVIOUS LISTS: | | | | | | 1.)PROVIDE INFORMATION ABOUT THE EXISTING DOOR. | | | PROVIDE A DESCRIPTION: | | | | | | IS THE EXISTING DOOR GLAZED? | | | DIMENSIONS OF GLAZING IN THE EXISTING DOOR | | | | | | THIS IS THE SIXTH REQUEST FOR INFORMATION IN REGARDS TO | | | THE EXISTING DOOR.PLEASE PROVIDE REQUESTED | | | INFORMATION. | | | | | | THE PLAN STATES "CHANGEOUT 1 DOOR OPENING NO SIZE | | | CHANGE FIBERGLASS DOOR GLAZED."I UNDERSTAND THAT THE | | | OPENING SIZE IS NOT CHANGING.THIS STATEMENT DOES NOT | | | ADDRESS MY VERY SPECIFIC QUESTIONS IN REGARDS TO THE | | | GLAZING.PROVIDE THE REQUESTED INFORMATION, IS THE | | | EXISTING DOOR GLAZED?IF IT IS, PROVIDE DIMENSIONS OF | | | THE GLAZING IN THE EXISTING DOOR. | | | | | | NUMEROUS NOTES REFER TO THE 25% RULE.ALTHOUGH THE 25% | | | RULE CAN BE APPLIED, THIS IS FOR REPLACEMENT GLAZING | | | ONLY.YOU CANNOT ADD NEW GLAZED OPENINGS OR INCREASE | | | THE AREA OF GLAZING. | | | | | | TO GET THIS PERMIT, YOU MUST EITHER PROVIDE HURRICANE | | | SHUTTER INFORMATION OR PROVIDE THE INFORMATION | | | REQUESTED SO THAT CODE COMPLIANCE CAN BE DETERMINED. | | | | | | IF YOU DO NOT UNDERSTAND THIS CORRECTION, PLEASE CALL | | | ME FOR ASSISTANCE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2007-04-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-04-30 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-04-30 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2007-04-30 16:00:30 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBEXISTING BUILDING CODE 2004 | | | FBC R RESIDENTIAL 2004 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | | | | 1.)PROVIDE INFORMATION ABOUT THE EXISTING DOOR. | | | PROVIDE A DESCRIPTION: | | | | | | SIZE OF DOOR | | | IS THE EXISTING DOOR GLAZED? | | | DIMENSIONS OF GLAZING IN THE EXISTING DOOR | | | | | | THIS IS THE FIFTH REQUEST FOR INFORMATION IN REGARDS TO | | | THE EXISTING DOOR.PLEASE PROVIDE REQUESTED | | | INFORMATION. | | | | | | THE PLAN STATES "CHANGEOUT 1 DOOR OPENING NO SIZE | | | CHANGE FIBERGLASS DOOR GLAZED."I UNDERSTAND THAT THE | | | OPENING SIZE IS NOT CHANGING.THIS STATEMENT DOES NOT | | | ADDRESS MY VERY SPECIFIC QUESTIONS IN REGARDS TO THE | | | GLAZING.PROVIDE THE REQUESTED INFORMATION, IS THE | | | EXISTING DOOR GLAZED?IF IT IS, PROVIDE DIMENSIONS OF | | | THE GLAZING IN THE EXISTING DOOR. | | | | | | NUMEROUS NOTES REFER TO THE 25% RULE.NOTE THAT THIS | | | DOES NOT APPLY ON APPLICATONS AFTER JANUARY,2007. | | | | | | TO GET THIS PERMIT, YOU MUST EITHER PROVIDE HURRICANE | | | SHUTTER INFORMATION OR PROVIDE THE INFORMATION | | | REQUESTED SO THAT CODE COMPLIANCE CAN BE DETERMINED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2007-03-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-03-23 |
Time |
18:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-03-23 |
Time |
18:07 |
Sent To |
|
|
| Notes |
| 2007-03-23 18:07:33 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBEXISTING BUILDING CODE 2004 | | | FBC R RESIDENTIAL 2004 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | | | | 1.)PROVIDE INFORMATION ABOUT THE EXISTING DOOR. | | | PROVIDE A DESCRIPTION: | | | | | | SIZE OF DOOR | | | IS THE EXISTING DOOR GLAZED? | | | DIMENSIONS OF GLAZING IN THE EXISTING DOOR | | | | | | THIS IS THE FOURTH REQUEST FOR INFORMATION IN REGARDS | | | TO THE EXISTING DOOR.PLEASE PROVIDE REQUESTED | | | INFORMATION. | | | | | | NEW COMMENT: | | | | | | 2.) FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED, | | | FAC9B72, WWW.FLORIDABUILDING.ORG.THE FLORIDA STATE | | | PRODUCT APPROVAL PROVIDED IS EXPIRED, FBC2001 RATHER | | | THAN FBC2004. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-03-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-03-08 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-03-08 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2007-03-08 13:59:44 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBEXISTING BUILDING CODE 2004 | | | FBC R RESIDENTIAL 2004 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | | | | 1.)PROVIDE INFORMATION ABOUT THE EXISTING DOOR. | | | PROVIDE A DESCRIPTION: | | | | | | SIZE OF DOOR | | | IS THE EXISTING DOOR GLAZED? | | | DIMENSIONS OF GLAZING IN THE EXISTING DOOR | | | | | | THIS IS THE THIRD REQUEST FOR INFORMATION IN REGARDS TO | | | THE EXISTING DOOR.PLEASE PROVIDE REQUESTED | | | INFORMATION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-02-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-02-20 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-02-20 |
Time |
17:06 |
Sent To |
|
|
| Notes |
| 2007-02-20 17:07:29 | ***CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBEXISTING BUILDING CODE 2004 | | | FBC R RESIDENTIAL 2004 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | | | | FROM PREVIOUS LIST, NOT ADDRESSED: | | | | | | WINDOW OR DOOR PERMIT APPLICATION, ONLY CHECKED ITEMS | | | APPLY | | | | | | | | | _XX_4. IS THE EXISTING DOOR A GLAZED DOOR? | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-01-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-01-26 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-01-26 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2007-01-26 16:34:15 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBEXISTING BUILDING CODE 2004 | | | FBC R RESIDENTIAL 2004 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | | | | WINDOW OR DOOR PERMIT APPLICATION, ONLY CHECKED ITEMS | | | APPLY | | | | | | ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH | | | THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13. | | | | | | ____2.PROVIDE BUILDING HEIGHT.DESIGN PRESSURES | | | FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE DESIGNED | | | USING ASCE7, FBC1609.1.1. DOCUMENTS PREPARED BY AN | | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED SEALED ORIGINALS FAC61G15-23.002. | | | | | | ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION | | | APPROVAL. | | | | | | _XX_4.IMPACT PROTECTION REQUIRED,FBC1609.1.4.IF | | | LESS THAN 25% OF THE TOTAL GLAZED AREA IS BEING | | | REPLACED, PROVIDE CALCULATIONS FBC EB507.3.IS THE | | | EXISTING DOOR A GLAZED DOOR? | | | | | | ____5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | | | ____6.PROVIDE A FLOOR PLAN SHOWING: WINDOW | | | LOCATIONS, SIZES, WINDOW TYPE, ROOM DESIGNATIONS.NOTE | | | EXISTING CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE | | | FOR BEDROOMS, FBC R310, FBC EB 505.1. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-11-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-07 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-07 |
Time |
16:09 |
Sent To |
B |
|
| Notes |
| 2007-11-07 16:10:08 | TO "SHILL' DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-04-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-30 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-30 |
Time |
11:17 |
Sent To |
B |
|
| Notes |
| 2007-04-30 11:17:38 | TO "SHILL' DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-03-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-23 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-23 |
Time |
11:37 |
Sent To |
B |
|
| Notes |
| 2007-03-23 11:37:25 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-03-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-07 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-07 |
Time |
10:00 |
Sent To |
B |
|
| Notes |
| 2007-03-07 10:00:34 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-02-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-15 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-15 |
Time |
16:12 |
Sent To |
B |
|
| Notes |
| 2007-02-15 16:12:38 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-01-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-01-26 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-12-21 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2006-12-21 15:11:42 | TO "MISC" BOX#1 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|