Plan Review Details - Permit 06120556
Plan Review Stops For Permit 06120556
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2007-11-16 Cont ID  
Sent By jwitmer Date 2007-11-16 Time 10:36 Rev Time 0.77
Received By jwitmer Date 2007-11-16 Time 10:36 Sent To PC
Notes
2007-11-16 10:37:25CLARIFICATION LETTER FROM DESIGNER OF RECORD FOR TRUSS
 STRAPS.OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2007-08-14 Cont ID  
Sent By jwitmer Date 2007-08-14 Time 16:05 Rev Time 2.22
Received By jwitmer Date 2007-08-14 Time 16:05 Sent To PC
Notes
2007-08-14 16:06:12REVISION# 4.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-07-06 Cont ID  
Sent By jwitmer Date 2007-07-06 Time 10:05 Rev Time 0.77
Received By jwitmer Date 2007-07-06 Time 10:05 Sent To PC
Notes
2007-07-06 10:08:42DEMO PARTIAL SLAB, AND BEARING WALLS. PLANS INDICATE
 NEW MONO SLAB AND COLUMNS. BUILDING PROVISO:
 BUILD BACK TO COMPLY WITH A-2 PER 2004 FBC-PLUMBING
 TABLE 403.1 RESTROOMS REQUIRED!

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-05-09 Cont ID  
Sent By jwitmer Date 2007-05-09 Time 13:41 Rev Time 2.22
Received By jwitmer Date 2007-05-09 Time 13:41 Sent To FIRE
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-04-12 Cont ID  
Sent By jwitmer Date 2007-04-12 Time 11:26 Rev Time 3.33
Received By jwitmer Date 2007-04-12 Time 11:26 Sent To  
Notes
2007-04-12 11:45:35BUILDING PLAN REVIEW
 PERMIT: 06120556
 ADD: 437 NORTHWOOD
 CONT: MEITZ-JUNIOR GENERAL CONT
 TEL: (561)719-2765
  
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE/
 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 2NDREVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2 ) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF
 THE COURT.
 NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS
 NOT ACTUALLY
 COMMENCED WITHIN 90 DAYS AFTER THE RECORDING THEREOF,
 SUCH NOTICE IS
 NULL & VOID. NOTE: 713.13(6)THE POSTING OF THE NOTICE
 OF COMMENCEMENT
 AT THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 3-5 COMPLIED.
  
 6) BUILDING PROVISO:
 ) 109.3.10* IMPACT OF CONSTRUCTION.
 ALL CONSTRUCTION ACTIVITY REGULATED BY
 THIS CODE SHALL BE PERMORMED IN A MANNER
 SO AS NOT TO ADVERSELY IMPACT THE
 CONDITION OF ADJACENT PROPERTY, UNLESS
 SUCH ACTIVITY IS PERMITTED TO AFFECT
 SAID PROPERTY PURSUANT TO A CONSENT BY
 THE APPLICABLE PROPERTY OWNER, UNDER
 TERMS & CONDITIONS AGREEABLE TO THE
 APPLICABLE PROPERTY OWNER.THIS INCLUDES
 BUT IS NOT LIMITED TO THE CONTROL OF
 DUST, NOISE, WATER OR DRAINAGE RUN-OFF,
 DEBRIS, AND THE STORAGE OF CONSTRUCTION
 MATERIALS. NEW CONSTRUCTION ACTIVITY
 SHALL NOT ADVERSELY IMPACT HISTORIC
 SURFACE WATER DRAINAGE FLOWS SERVING
 ADJACENT PROPERTIES, & MAY REQUIRE
 SPECIAL DRAINAGE DESIGN COMPLYING WITH
 ENGINEERING STANDARDS TO PRESERVE THE
 POSITIVE PATTERNS OF THE AFFECTED SITES.ACCORDINGLY,
 DEVELOPERS, CONTRACTORS,
 AND OWNERS OF ALL NEW RESIDENTIAL
 DEVELOPMENT, INCLUDING ADDITIONS, POOLS,
 PATIOS, DRIVEWAYS, DECKS, OR SIMILAR
 ITEMS, ON EXISTING PROPERTIES RESULTING
 IN A DECREASE IN EXCESS OF 800SQ FT OF
 PERMEABLE LAND AREA ON ANY PARCELL SHALL
 AS A PERMIT CONDITION, PROVIDE A
 PROFESSIONALLY PREPARED DRAINAGE PLAN
 CLEARLY INDICATING COMPLIANCE WITH THIS
 PARAGRAPH. UPON COMPLETION OF THE
 IMPROVEMENT, A CERTIFICATE FROM A
 LICENSED ENGINEER SHALL BE SUBMITTED TO
 THE INSPECTOR IN ORDER TO RECEIVE
 APPROVAL OF THE FINAL INSPECTION.
  
 7A- 7I) COMPLIED.
  
 7J)2ND REQUEST, SHEET A-2 INDICATES TWO ARCH DETAILS,
 PLEASE PROVIDE A CUTSECTION THROUGH WHERE THESE ARCHES
 ARE TO BE USED.
 106.1.2* ADDITIONAL INFORMATION REQUIRED.
  
 7K) 2ND REQUEST THE PLANS INDICATE THE AT THE REAR OF
 THE BUILDING PAVERS ARE TO BE RAMPED UP TO THE
 BUILDING, PLEASE PROVIDE THE LENGTH OF RAMP AND THE
 HIGTH OF THE RAMP. IF IT EXCEEDS 6" IN HEIGTH OR 72" IN
 LENGTH:
 11.4.8.5. HANDRAILS: IF A RAMP HAS
 A RISE GREATER THAN 6" OR A HORIZONTAL
 PROJECTION GREATER THAN 72", THEN IT
 SHALL HAVE HANDRAILS ON BOTH SIDES.
  
 8A-C) COMPLIED.
  
 8D) 2ND REQUEST, PLANS DO NOT IDENTIFY THE TYPE OF 2X8
 TO BE USED AS RAFTERS, PROVIDE THE TYPE OF SPECIES OF
 WOOD.
 106.1.2*ADDITIONAL INFORMATION REQUIRED.
  
 9)COMPLIED.
  
 10) COMPLIED.
  
 11) YALE ORGON FL6648 NOW IS MISSING AL-FAROOQ
 EVALUATION REPORT AND TECHNICAL DRAWINGS W97-24 (3
 SHEETS)
  
 12-15) COMPLIED.
  
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-01-22 Cont ID  
Sent By jwitmer Date 2007-01-22 Time 10:14 Rev Time 2.22
Received By jwitmer Date 2007-01-22 Time 10:14 Sent To  
Notes
2007-01-22 13:24:11BUILDING PLAN REVIEW
 PERMIT: 06120556
 ADD: 437 NORTHWOOD
 CONT: MEITZ-JUNIOR GENERAL CONT
 TEL: (561)719-2765
  
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE/
 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2 ) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF
 THE COURT.
 NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS
 NOT ACTUALLY
 COMMENCED WITHIN 90 DAYS AFTER THE RECORDING THEREOF,
 SUCH NOTICE IS
 NULL & VOID. NOTE: 713.13(6)THE POSTING OF THE NOTICE
 OF COMMENCEMENT
 AT THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 3) JILL K. RISSER-BUILDING DESIGN.
 FL S S 481.223(1) (A) FLORIDA STAUTES, PROHIBITS A
 PERSON FROM KNOWINGLY PRACTICING
 ARCHITECTURE UNLESS THAT PERSON IS IN AN ARCHITECT OR A
 REGISTERED ARCHITECT.
 SEE DIVISION OF ADMINISTRATIVE HEARINGS CASE N0.
 03-0489.
  
 4) PLEASE PROVIDE A SURVEY OF THIS LOT WITH THE
 PLACEMENT OF STRUCTURE.
 106.1.2*/ TABLE 601, TABLE 602 & TABLE 704.8. SIGNATURE
 OF THE PROVIDED SURVEY IS A COPY NOT AN ORIGINAL.
  
 5)110.2* W. P. B. ADMINISTRATIVE
 CODE, INFORMATION THAT IS REQUIRED FOR
 RECORD KEEPING & FOR CERTIFICATE OF
 OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PERMIT WAS ISSUED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C1) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601.
 C2) LEVEL OF ALTERATION: LEVEL 1, LEVEL 2 OR LEVEL 3?
 D) THE DESIGN OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED, WHETHER THE SPRINKLER SYSTEM
 IS REQUIRED.
 F) ANY SPECIAL STIPULATIONS & CONDITIONS
 OF THE BUILDING PERMIT.
 G) NUMBER OF UNITS
 H) NUMBER OF FLOORS
  
 6) NOTE 109.3.10* IMPACT OF CONSTRUCTION.
 ALL CONSTRUCTION ACTIVITY REGULATED BY
 THIS CODE SHALL BE PERMORMED IN A MANNER
 SO AS NOT TO ADVERSELY IMPACT THE
 CONDITION OF ADJACENT PROPERTY, UNLESS
 SUCH ACTIVITY IS PERMITTED TO AFFECT
 SAID PROPERTY PURSUANT TO A CONSENT BY
 THE APPLICABLE PROPERTY OWNER, UNDER
 TERMS & CONDITIONS AGREEABLE TO THE
 APPLICABLE PROPERTY OWNER.THIS INCLUDES
 BUT IS NOT LIMITED TO THE CONTROL OF
 DUST, NOISE, WATER OR DRAINAGE RUN-OFF,
 DEBRIS, AND THE STORAGE OF CONSTRUCTION
 MATERIALS. NEW CONSTRUCTION ACTIVITY
 SHALL NOT ADVERSELY IMPACT HISTORIC
 SURFACE WATER DRAINAGE FLOWS SERVING
 ADJACENT PROPERTIES, & MAY REQUIRE
 SPECIAL DRAINAGE DESIGN COMPLYING WITH
 ENGINEERING STANDARDS TO PRESERVE THE
 POSITIVE PATTERNS OF THE AFFECTED SITES.ACCORDINGLY,
 DEVELOPERS, CONTRACTORS,
 AND OWNERS OF ALL NEW RESIDENTIAL
 DEVELOPMENT, INCLUDING ADDITIONS, POOLS,
 PATIOS, DRIVEWAYS, DECKS, OR SIMILAR
 ITEMS, ON EXISTING PROPERTIES RESULTING
 IN A DECREASE IN EXCESS OF 800SQ FT OF
 PERMEABLE LAND AREA ON ANY PARCELL SHALL
 AS A PERMIT CONDITION, PROVIDE A
 PROFESSIONALLY PREPARED DRAINAGE PLAN
 CLEARLY INDICATING COMPLIANCE WITH THIS
 PARAGRAPH. UPON COMPLETION OF THE
 IMPROVEMENT, A CERTIFICATE FROM A
 LICENSED ENGINEER SHALL BE SUBMITTED TO
 THE INSPECTOR IN ORDER TO RECEIVE
 APPROVAL OF THE FINAL INSPECTION.
  
 7)SHEET# 1;
 7A) THE PLANS INDICATE TO REUSE THE EXISTING
 SIDE GLASS WINDOWS, ARE THEY BEING MOVED? 106.1.2*
  
 7B) ENTRY BEAM DETAIL INDICATES NEW FOOTINGS, WHERE IS
 THE PROPERTY LINE,
 DO THEY PROTRUDE PAST THE PROPERTY LINE? OR ARE THE
 COLULMNS OFFSET?
  
 7C) PLANS INDICATE A RESTROOM WITH THE DOOR SWINGING
 INTO THE CLEAR FLOOR SPACE REQUIRED FORTHE LAV.
 11-4.19.3
 CLEAR FLOOR SPACE.
 A CLEAR FLOOR SPACE 30 INCHES BY 48 INCHES (760 MM BY
 1219 MM)
 COMPLYING WITH SECTION 11-4.2.4 SHALL BE PROVIDED IN
 FRONT OF A LAVATORY
 TO ALLOW FORWARD APPROACH. SUCH CLEAR FLOOR SPACE SHALL
 ADJOIN OR OVERLAP
 AN ACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM OF 19
 INCHES (485 MM)
 UNDERNEATH THE LAVATORY (SEE FIGURE 11-32 ).
  
 7D) RESTROOM TURNING RADIUS:
 11-4.22.3 CLEAR FLOOR SPACE.
 THE ACCESSIBLE FIXTURES AND CONTROLS REQUIRED IN
 SECTIONS 11-4.22.4 , 11-4.22.5 , 11-4.22.6 AND
 11-4.22.7 SHALL BE ON AN ACCESSIBLE ROUTE. AN
 UNOBSTRUCTED TURNING SPACE COMPLYING WITH SECTION
 11-4.2.3 SHALL BE PROVIDED WITHIN AN ACCESSIBLE TOILET
 ROOM. THE CLEAR FLOOR SPACE AT FIXTURES AND CONTROLS,
 THE ACCESSIBLE ROUTE, AND THE TURNING SPACE MAY
 OVERLAP.
  
 7E) PLANS INDICATE A 42" HIGH BASE CABINET WITH SINK
 AND UNDER COUNTER REFRIGARATOR. SINKS:
 11-4.24.2 SINKS, HEIGHT. SINKS SHALL
 BE MOUNTED WITH THE COUNTER NO HIGHER
 THAN 34" ABOVE THE FINISH FLOOR.
 11-4.24.3 KNEE CLEARANCE THAT IS AT
 LEAST 27" HIGH 30" WIDE, AND 19" DEEP
 SHALL BE PROVIDED UNDERNEATH SINKS.
 11-4.24.5 CLEAR FLOOR SPACE.
 A CLEAR FLOOR SPACE AT LEAST 30 INCHES BY 48 INCHES
 (760 MM BY 1219 MM) COMPLYING WITH SECTION 11-4.2.4
 SHALL BE PROVIDED IN FRONT OF A SINK TO ALLOW FORWARD
 APPROACH. THE CLEAR FLOOR SPACE SHALL BE ON AN
 ACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM OF 19
 INCHES (485 MM) UNDERNEATH THE SINK
 .
 7F)AT THE REAR OF THE BUILDING THERE APPEARS TO BE A
 NEW WINDOW,A EXISTING DOOR AND A PAIR OF FRENCH
 DOORS. PLEASE PROVIDE IF THIS IS A FRAME WALL OR A
 PORTION FRAME AND CBS? 106.1.2*.
  
 7G) AT THE REAR OF THE BUILDING THERE APPEARS TO BE AN
 EXTERIOR SHOWROOM , TO GAIN ACCESS YOU HAVE TO GO
 THROUGH A 2'-6" DOOR THAT WILL BE REPLACED.11-4.13.5
 DOORWAYS, MINIMUM CLEAR WIDTH:
 DOORWAY SHALL HAVE A MINI-
 MUM CLEAR OPENING OF 32" WITH THE DOOR
 OPEN 90 DEGREES, MEASURED BETWEEN THE
 FACE OF THE DOOR AND THE OPPOSITE STOP.
  
 7H) THERE IS A NOTE INDICATING PARAPET WALL CAPS TO BE
 ADDED TO ALL EXISTING WALLS WHERE APPLICABLE? PLEASE
 EXPLAIN THIS STATEMENT? 106.1.2* ADDITIONAL INFORMATION
 REQUIRED.
  
 7I) PLANS INDICATE RIGID FOAM BOARD INSULATION MAY BE
 ADDED TO THE EXTERIOR OF THE ROOF.
 IS THE ROOF BEING REPLACED? NO ROOFING CONTRACTOR IS
 SIGNED ON. G.C. CAN NOT DO FLAT ROOFS.
 OUT OF THE SCOPE OF THEIR LICENSE. FL S S
 489.113(3)(B)QUALIFICATIONS FOR PRACTICE;
 RESTRICTIONS.
  
 7J) PLANS INDICATE (2) ARCH DESIGNS, THERE IS NO
 REFRENCE AS TO WHERE THEY WILL BE USED?
  
 7K) PLANS INDICATE AT THE REAR OF THE BUILDING PAVER
 ARE TO BE RAMPED UP TO THE BUILDING AT A RATE NOT TO
 EXCEED
 1/12 INCHES.
 11-4.8.4.(2) LANDINGS. ALL LANDINGS
 ON RAMPS SHALL NOT BE LESS THAN 60"
 CLEAR, & THE BOTTOM OF EACH RAMP SHALL
 HAVE NOT LESS THAN 72" OF STRAIGHT &
 LEVEL CLEARENCE.
 11.4.8.5. HANDRAILS: IF A RAMP HAS
 A RISE GREATER THAN 6" OR A HORIZONTAL
 PROJECTION GREATER THAN 72", THEN IT
 SHALL HAVE HANDRAILS ON BOTH SIDES.
  
 7L) THE PLANS INDICATE THE PRESSURES FOR WINDOWS AND
 DOORS, PLEASE PROVIDE ALSO FOR THE FLAT ROOF ZONES 1,2
 & 3.
 TABLE 1609.2B, WHAT IS THE WIDTH OF "A"?
  
 8) SHEET # 2:
 8A) PLANS INDICATE THERE IS A CHOICE OF STRUCTURAL
 STEEL COLUMNS OF 6"X6" PT. PLANS ARE TO SHOW ONE OR THE
 OTHER NOT A CHOICE.
  
 8B)IF THE SECTION THROUGH THE PERGOLA IS SECTION "A"
 PLEASE PROVIDE A SECTION THROUGH AS SHOWN AS "B" MARKED
 ON PLAN?
  
  
 8C) THE DESIGN CRITERIA FOR THE EXISTING BUILDING IS
 FOR AN ENCLOSED BUILDING, PLEASE PROVIDE THE DESIGN
 CRITERIA FOR THE
 PERGOLA? 2004 FL. BLD CODE 1603.1.4 THE FOLLOWING
 INFORMATION RELATED TO WIND
 SHALL BE SHOWN ON THE CONSTRUCTION
 DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT, IS THIS DESIGNED AS
 OPEN?
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 8D) PLANS DO NOT IDENTIFY THE TYPE OF 2X8 TO USE AS
 RAFTERS. PROVIDE THE SPECIES OF WOOD, AND GRADE.
  
 8E) PLANS IDENTIFY THE SIZE OF THE BOTTOM STEEL PLATE
 BUT NOT THE UPPER PLATE IDENTIFIED ON THE PLAN?
  
 9) WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 10)PRODUCT APPROVALS SUBMITTED WITH PERMIT
 APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 11) PRODUCT APPROVAL: YALE ORGON " LA FRANCIS"
 IS MISSING THE FLORIDA COVERSHEET.
  
 12) YKK AP AMERICA "20D NARROW STILE"
 IS MISSING THE FLORIDA COVERSHEET.
  
 13) EASTERN METAL SUPPLY: STORM SHUTTERS
 MISSING THE TECHNICAL SHEETS THAT ACCOMPANY EVALUATION
 REPORT,PLEASE PROVIDE 1-17.
 ONCE THE TECHNICAL SHEETS ARE OBTAINED HIGHLIGHT WHICH
 SYSTEMS TO BE USED. ALSO HIGHLIGHT WHICH ANCHOR
 APPLICATION SHALL BE USED.
 THE THIRD ITEM THE CITY WILL REQUIRE IS WHERE THE STORM
 SHUTTERS WILL BE LOCATED ON SITE?
  
 14) TAMKO ROOFING- MODIFIED BITUMEN ROOF SYSTEM IS FOR
 A WOOD NON-INSULATED ROOF,
 HIGHLIGHTED IS OPTION# 1 WHICH PROVIDES -60.0 PSF,
 WHEREAS ZONE (3) THE PRESSURE IS (-89).
 PROVIDE ENHANCED ROOF FASTER DENSITIES, CALCULATIONS
 FROM RAS 117.
  
 15) THE NEW EXTERIOR SHOWROOM MAY REQUIRE IMPACT FEES,
 TO BE REVIEWED BY COUNTY,
 BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2007-05-11 Cont ID  
Sent By dpalmer Date 2007-05-11 Time 11:21 Rev Time 0.00
Received By dpalmer Date 2007-05-11 Time 10:12 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2007-05-02 Cont ID  
Sent By dpalmer Date 2007-05-02 Time 11:40 Rev Time 0.00
Received By dpalmer Date 2007-05-02 Time 09:52 Sent To  
Notes
2007-05-02 11:41:01*** UNSAT **
  
 1) NOTE: PLEASE SEE THE ENERGY CALCULATIONS FOR TRACK
 LIGHTING SHALL INCLUDE THELOAD BASED ON 30VA PER
 LINEAR FOOT OR THE VA PER FIXTURE WHICH EVER IS
 GREATER. PLANS APPEAR TO SHOW THE TRACK AS LINE VOLTAGE
 OF 120V WITH LOW VOLTAGE TRACK HEADS AS THE PLANS DO
 NOT INDICATE LV TRANSFORMERS AT ANY LOCATIONS ON PLANS
 ON THE LINE SIDE OF THE TRACK ITSELF. THE TOTAL IN THE
 ENERGY CALCULATIONS MUST BE THE GREATER OF THE TWO,
 UNLESS USING LV TRANSFORMERS ON THE LINE SIDE OF THE
 TRACK CONNECTIONS WHICH LIMITS THE LOAD ON THE TRACK.
 **PLEASE SEE 13-415.1.ABC.1.2
  
 ** PLEASE KNOW AS THIS IS A STATUTORY REQUIREMENT, THE
 ENERGY CALCULATIONS MUST CORRECT.
 ** PLEASE SEE THE OWNER/OWNER AGENT DID NOT SIGN THE
 CALCULATIONS.
 ** IF THIS IS THE ONLY COMMENT ONCE ALL TRADES ARE
 DONE, THEN THE CORRECTED CALCULATIONS MAY BE BROUGHT
 IN. IF THE PLANS ARE REVISED, THEN THIS WILL NEED TO BE
 DONE ONE ALL THE REVIEWS ARE DONE AND PLANS WOULD BE
 RESUBMITTED.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-03-25 Cont ID  
Sent By dpalmer Date 2007-03-25 Time 10:46 Rev Time 0.00
Received By dpalmer Date 2007-03-25 Time 09:20 Sent To  
Notes
2007-03-25 10:46:53 
  
 ****** UNSAT 2ND REVIEW******
  
 ** PLEASE KNOW THAT ANY REFERENCE TO THE FBC CHAPTER 1
 IN THE PLAN REVIEW COMMENTS CAN BE FOUND IN THE
 ADMINISTRATIVE SECTION OF THE 2004 FBC AS ADOPTED BY
 THE CITY OF WEST PALM BEACH.
  
 ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW STILL
 NEED TO BE ADDRESSED ALONG WITH NEW COMMENTS BASED ON
 CHANGES ON PLANS.
  
  
 1) NOTE:PLEASE SEE THE ENERGY CALCULATIONS NEED TO BE
 SEALED SO THAT THE SEAL IS CLEAR AND VISIBLE WITH ALL
 INFORMATION ON SAID SEAL AS REQUIRED PER FAC
 61G15-23.001, FS 471.025
 THIS IS THE SAME COMMENT FROM PREVIOUS REVIEW, AS THE
 SAME SHEETS WERE SUBMITTED BACK WHICH ARE DATED OCT OF
 06.
 PLEASE SEE THE NEXT COMMENT.
  
 2) NOTE:RESPONSE MENTIONS THIS CONTAINS 2-8INCH BLOCK
 WALLS WHICH DOES NOT NECESSARILY DEFINE THIS AS
 SEPARATE *BUILDING* BY DEFINITION. THIS IS THE RATE
 WALL ALONG WITH THE STRUCTURE WHICH MUST BE COLLAPSIBLE
 ON BOTH SIDES WITHOUT AFFECTING THE STRUCTURAL
 INTEGRITY OF THE OTHER STRUCTURE. PLEASE CLARIFY THIS
 ON PLANS.
 PLEASE SEE THE ENERGY CALCULATIONS SUBMITTED ARE THE
 SAME METHOD *A* WHICH DOES NOT PROVIDE THE INPUT DATA
 REPORT WHICH IS REQUIRED AS NOTED ON PAGE ONE OF THE
 SHEETS. PLEASE ALSO SEE THAT THE PLANS SEEM TO BE
 TAKING PRESCRIPTIVE METHODS OF *C* AND ALSO TABLE *C*?
  
 PLEASE SEE THE EXTERIOR LIGHTING SHALL CORRELATE WITH
 THE EXTERIOR LIGHTING ON PLANS.
 PLEASE CLARIFY THAT THIS IS ONE INDIVIDUAL BUILDING AS
 DEFINED IN THE FBC FIRST, THEN PLEASE COORDINATE THE
 METHODS.
 PLEASE SEE THE LIGHTING AS SHOWN ON PLANS IS TO
 CORRELATE WITH THE INPUT DATA REPORT. PLEASE ALSO SEE
 13-415.2.ABC.1.2 SUB PARAGRAPH 3.
  
 ** AS NOTED ON PREVIOUS REVIEW. IF THIS IS PART OF A
 BUILDING IN EXCESS OF 5KSQ FT THEN THE REQUIREMENTS OF
 13-415.1.ABC.1.1, .1.2 AND .1.3 SHALL BE MET. PLEASE
 KNOW HOWEVER INFORMATION FOR 13-415.2 IS REQUIRED AS
 THE LIGHTING PERFORMANCE LEVELS NEED TO BE STATED TO
 MEET THE NEW REQUIREMENTS.
 THE SURVEY SUBMITTED LENDS TO THAT THIS IS SEPARATE
 BUILDING WHICH SHOWS A PROPERTY LINE, HOWEVER WALL
 RATINGS ARE NOT CLEAR AND STRUCTURAL ELEMENTS ARE NOT
 CLEAR AT THIS TIME.
 PLEASE SUBMIT A FIXTURE LEGEND FOR LIGHTING FIXTURES TO
 BE INSTALLED AND CORRELATE WITH THE IDENTIFICATION ON
 PLANS.
 NOT ENOUGH INFORMATION ON LIGHTING ALLOWANCES IS
 PROVIDED.
  
 3) NOTE: PLEASE SUBMIT AND SHOW ALL CIRCUITING ON PLANS
 AND CORRELATE WITH A PANEL SCHEDULE WHICH IS REQUIRED
 TO BE SUBMITTED. PLEASE SEE SOME CIRCUITS ARE MISSING
 CIRCUITING, ALTHOUGH MOST WERE DONE. THE PLANS ARE
 REDLINED WITH SOME OF THE CIRCUITING MISSING. 408.4,
 310.16, 240.4
 FBC 106.1.2, 106.3.5.1.2 ADMIN SECTION.
  
 4) NOTE: PLEASE SEE THE RISER IS NOW SHOWING NEW
 CONDUCTORS WHICH HAVE INCREASED FROM THE PREVIOUS PLANS
 HOWEVER THE SERVICE ENTRANCE CONDUCTORS AND FEEDERS ARE
 NOT LARGE ENOUGH. PLEASE SEE 310.16 FOR SIZING. MAY NOT
 USE 310.15B6 AS THIS IS NOT RESIDENTIAL.
 310.16, 240.4, ETC
 5) NOTE: ONLY NOTED, THE SEPARATE SERVICE WILL DEPEND
 ON THE *SEPARATE BUILDING DEFINITION* SEEMS TO BE OK.
  
 7) NOTE: PLEASE SEE THE PLANS NOW NOTE AND SHOW
 EMERGENCY AND EXIT LIGHTS , YET THE NOTE ON THE PLANS
 MENTIONS CIRCUITING TO BE PER 700.12E, AND THESE ARE ON
 A SEPARATE CIRCUIT? PLEASE SEE TEXT TAKEN FROM NEC.
 **THE BRANCH CIRCUIT FEEDING THE UNIT EQUIPMENT SHALL
 BE THE SAME BRANCH CIRCUIT AS THAT SERVING THE NORMAL
 LIGHTING IN THE AREA AND CONNECTED AHEAD OF ANY LOCAL
 SWITCHES.**
 PLEASE KNOW IF TRYING TO MEET THE EXCEPTION THE LOCK ON
 DEVICE SHALL BE AN INTEGRAL PART OF THE BREAKER, NOT
 ONE THAT ONLY SNAPS INTO PLACE OR CAN BE EASILY REMOVED
 OR FALL OFF WHEN PANEL COVER IS REMOVED.
 110.3, 90.4.
  
 8) NOTE: PLEASE 220.43B FOR LOADS TO BE SHOWN FOR TRACK
 LIGHTING. PLEASE SEE THE PLANS INDICATE 18FT OF TRACK
 AND AT 200VA PER FT, HOWEVER THIS WOULD BE 3600VA,
 PLANS SHOW 1800VA.
 PLEASE CORRECT.
  
 9) NOTE: PLEASE SEE THAT ALL CONTINUOUS LOADS ARE TO BE
 SHOWN AT 125%, BUT THIS IS ONLY THE CONTINUOUS LOADS.
 PLEASE SEE SOME OF THE LOADS AT THE TOP OF THE LOAD
 CALCULATIONS ARE SHOWN, BUT NOT ALL AS REQUIRED IN THE
 CALCULATIONS.
 PLEASE SEE SOME LOADS LIKE THE REFRIGERATOR AND THE
 WATER COOLER AND THE CU DO NOT NEED TO BE SHOWN AT
 125%.
 PLEASE CALL TO GO OVER IF NEED BE.
 215.3, 230.42 ETC.
 220.
  
 10) NOTE: PLEASE SEE 600.5, AS THIS REQUIRES A SIGN
 CIRCUIT AND LOADS TO BE SHOWN FOR THIS CIRCUIT
 ACCORDINGLY. PLEASE SEE THIS CIRCUIT IS NOT PERMITTED
 TO CONTAIN ANY OTHER LOADS ON THIS DEDICATE CIRCUIT
 INCLUDING OUTSIDE/EXTERIOR LIGHTING.
  
 11) NOTE: PLEASE VERIFY THE OVER CURRENT
 PROTECTION/WIRE SIZES AND THE SIZE OF THE WATER HEATER.
 THIS UNIT IS BEING SHOWN AS A 20GALLON UNIT WITH 40AMP
 OCP AND #8 CONDUCTORS.
 PLEASE SEE 422.13 AS THE MINIMUM LOADS, OCP, BRANCH
 CIRCUIT IS TO BE FIGURED AT 125%,BUT SECTION 422.11E3
 DOES LIMIT THE OCP AT 150%.
 PLEASE ADJUST THE OCP AND LOADS. IF THERE ARE
 QUESTIONS, PLEASE CALL.
 PLEASE SEE THE NEC HANDBOOK AS THIS GIVES THIS
 INFORMATION.
  
 12) NOTE: PLEASE VERIFY THE MAXIMUM OCP FOR THE AIR
 HANDLER UNIT, SHOWS 60A OCP ON AN 8KW UNIT. PLEASE SEE
 MANUFACTURES SPECS. (MOST LIKELY 50AMP). THIS WOULD
 AVOID REVISING AT ALTER DATE.
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-01-14 Cont ID  
Sent By dpalmer Date 2007-01-14 Time 08:33 Rev Time 0.00
Received By dpalmer Date 2007-01-14 Time 07:35 Sent To  
Notes
2007-01-14 08:37:19** UNSAT **
  
 1) NOTE: PLEASE SEE FLORIDA STATUTES 481.229, 481.221,
 PLANS ARE NOT PERMITTED TO BE DONE BY A DESIGNER UNLESS
 LICENSED UNDER THE SECTIONS AS NOTED AT A MINIMUM.
 PLEASE SEE THAT THE PLANS SHALL BE DONE BY AN ARCHITECT
 AT A MINIMUM. PLEASE SEE THE ELECTRICAL PLANS ARE NOT
 SIGNED, DATED OR SEALED BY A RESPONSIBLE PERSON
 LICENSED UNDER FS 481 OR 471.
 PLEASE CONTACT THE FLORIDA BOARD OF ARCHITECTS OR THE
 STATE?S LEGAL COUNSEL TO THE BOARD IF THERE ARE
 QUESTIONS REGARDING THE SCOPE OF WORK PERMITTED.
 CONTACT INFORMATION IS AVAILABLE IF NEEDED.
 THIS IS A COMMERCIAL SPACE FOR PUBLIC USE AND THE
 VALUE EXCEEDS $25K.
 ** THIS COMMENT IS REQUIRED WHETHER OR NOT COMMENT IS
 MADE BY ANY OTHER REVIEWER(S). ONE COPY OF PLANS ARE
 BEING RETAINED BY THIS OFFICE.
  
 2) NOTE: PLEASE SEE THAT ALL CODES SHALL BE STATED ON
 PLANS FOR THE DESIGNS WHICH THEY ARE UNDER.
 PLEASE KNOW AS THIS WAS SUBMITTED FOR PERMIT AFTER
 DECEMBER 8TH, 2006, THE FOLLOWING NEW CODES ARE
 RELEVANT.
 2006 REVISIONS TO THE 2004 FBC.
 2005 NFPA-70
 PLEASE SEE THE OTHER CODES WHICH ARE REQUIRED TO BE
 STATED ON PLANS FOR ELECTRICAL ARE:
 2002 NFPA-72 AND 2003 NFPA-101.
  
 3) NOTE: PLEASE SEE THE ENERGY CALCULATIONS NEED TO BE
 SEALED SO THAT THE SEAL IS CLEAR AND VISIBLE WITH ALL
 INFORMATION ON SAID SEAL AS REQUIRED PER FAC
 61G15-23.001, FS 471.025
  
 4) NOTE: PLEASE CLARIFY THAT THIS IS ONE INDIVIDUAL
 BUILDING AS DEFINED IN THE FBC. PLEASE SEE DEFINITIONS
 AS IF THIS IS PART OF A "BUILDING" WHICH IS LARGER THAN
 5K SQ FT THEN THE REQUIREMENTS OF 13-415.1.ABC.1.1,
 .1.2 AND .1.3 SHALL BE MET.
 PLEASE KNOW HOWEVER INFORMATION FOR 13-415.2 IS
 REQUIRED AS THE LIGHTING PERFORMANCE LEVELS NEED TO BE
 STATED TO MEET THE NEW REQUIREMENTS.
 THE SURVEY SUBMITTED LENDS TO THAT THIS IS SEPARATE
 BUIDLING WHICH SHOWS A PROPERTY LINE, HOWEVER WALL
 RATINGS ARE NOT CLEAR AND STRUCTURAL ELEMENTS ARE NOT
 CLEAR AT THIS TIME.
 PLEASE SUBMIT A FIXTURE LEGEND FOR LIGHTING FIXTURES TO
 BE INSTALLED AND CORRELATE WITH THE IDENTIFICATION ON
 PLANS.
 NOT ENOUGH INFORMATION ON LIGHTING ALLOWANCES IS
 PROVIDED.
  
 5) NOTE: PLEASE SUBMIT AND SHOW ALL CIRCUITING ON PLANS
 AND CORRELATE WITH A PANEL SCHEDULE WHICH IS REQUIRED
 TO BE SUBMITTED.
 PLEASE SEE THAT SOME ITEMS FOR CODE COMPLIANCE CAN NOT
 BE VERIFIED AT THIS TIME.
 408.4, 310.16, 240.4
 FBC 106.1.2, 106.3.5.1.2 ADMIN SECTION.
  
 6) NOTE: PLEASE SEE THE RISER IS MISSING THE SERVICE
 ENTRANCE CONDUCTORS AS REQUIRED.
 310.16, 240.4, ETC
 PLEASE SEE THAT THE 1/0'S WHICH ARE BEING SHOWN TO THE
 PANEL DO NOT MEET MINIMUM CODE FOR SIZE OF THE SERVICE
 AS SHOWN.
 PLEASE SEE 310.16, 240.4 FOR MINIMUM SIZES REQUIRED.
 FBC 106.1.2, 106.3.5.1.2
  
 7) NOTE: PLEASE SEE PLANS STATE THE SERVICE MAY CONTAIN
 AN OPTIONAL METER MAIN PANEL OUTSIDE, THIS IS OK;
 HOWEVER PLEASE KNOW THAT IF THIS IS THE OPTION TAKEN,
 PLANS WILL BE REQUIRED TO BE REVISED TO SHOW ACTUAL
 INSTALLATION(S).
  
 8) NOTE: PLEASE SEE THE PLANS ALSO MENTIONS OPTIONAL
 EXIT LIGHTS AND THE SECTION GIVEN ON THE FBC DOES NOT
 PRESENT AN EXCEPTION TO THIS. PLEASE EXPLAIN RATIONAL
 FOR TRYING TO MEET AN EXCEPTION AND STATE WHAT SECTIONS
 GIVE THIS. PLEASE SEE THE SECTION GIVEN STATES THAT
 ILLUMINATION SHALL BE PROVIDED.
 PLEASE SEE NFPA-101 7.8 AND 7.9 AS MEANS OF EGRESS
 LIGHTING IS REQUIRED TO THE PUBLIC RIGHT OF WAY. (FLOOR
 AREAS 1FT CANDLE MIN).
 PLEASE SEE NOTES FROM THE FIRE MARSHAL'S REVIEW AND
 BUILDING REVIEW WHICH MAY EXTEND TO THIS.
 PLEASE KNOW IN EITHER CASE THE EM/EXT LIGHT SHALL BE
 CIRCUITED PER 700.12E.
  
 9) NOTE: PLEASE SEE NOTES ON PLANS MENTIONS A FIRE
 ALARM SYSTEM SHALL BE INSTALLED. PLEASE KNOW THAT EVEN
 THOUGH THIS WILL BE UNDER A SEPARATE PERMIT, THE BASE
 SYSTEM SHALL BE SHOWN AT THIS TIME WITH ALL LEVELS FOR
 STROBES INTENSITIES AND SOUNDING LEVELS STATED ON
 PLANS.
 PLEASE SEE FBC 11-4.28.1,.2,AND .3(4) FOR MINIMUM
 LEVELS WHEN A FA SYSTEM IS INSTALLED.
  
 10) NOTE: PLEASE SUBMIT COMPLETE LOAD CALCULATIONS FOR
 THIS SPACE BASED ON A COMMERCIAL BUILDING.
 PLEASE SEE NEC 220.12, 220.14, 220.43(A) & (B), 220.44
 ETC.
 PLEASE ALSO SEE THAT ALL CONTINUOUS LOADS SHALL BE
 SHOWN AT 125% 215.3, 230.42 ETC.
 PLEASE SEE THE LOADS AS SHOWN FOR THE LIGHTING SHALL BE
 SIZED BASED ON THE MAXIMUM LEVELS FOR A 15A CIRCUIT.
 PLEASE SEE THE 15AMP CIRCUITS ARE BEING SHOWN WITH
 LOADS OF 2KW ON EACH WHICH EXCEEDS THE RATINGS OF
 THESE.
 (TYPICAL MAX 1440VA 15A/1920VA 20A) HOWEVER PLEASE SEE
 THE CODE SECTIONS GIVEN FOR PERMITTED LOADS. ALSO NEC
 210
  
 11) NOTE: PLEASE SEE MISSING SHOW WINDOW RECEPTACLES
 PER 210.62 AND LOADS PER 220.43.
  
 12) NOTE: PLEASE SEE 600.5FOR THE SIZE AND LOADS
 REQUIRED TO BE FIGURED FOR THE SIGN CIRCUIT(S).
  
 13) NOTE: PLEASE SEE EXTERIOR SPACE IS BEING NOTED AS A
 SHOW ROOM IN A PERGOLA AREA; PLEASE STATE WET LOCATIONS
 FOR FIXTURE, BOXES AND WIRING METHODS.
 FBC 106.1.2
 NEC 300
  
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2007-05-07 Cont ID  
Sent By mawillia Date 2007-05-07 Time 11:41 Rev Time 0.00
Received By mawillia Date 2007-05-07 Time 11:26 Sent To  
Notes
2007-05-07 11:41:30*****APPROVED*****
 ALL COMMENTS TAKEN FROM THE PREVIOUS FIRE PLAN REVIEWS
 HAVE BEEN ADDRESSED; PLAN SHEETS A-2 AND E-1 WERE
 STAMPED, INITIALED, AND DATED.
  
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2007-04-11 Cont ID  
Sent By mawillia Date 2007-04-11 Time 17:10 Rev Time 0.00
Received By mawillia Date 2007-04-11 Time 16:53 Sent To  
Notes
2007-04-11 17:10:35*****DENIED*****
 THE FOLLOWING COMMENTS TAKEN FROM THE PREVIOUS FIRE
 PLAN REVIEW STILL NEED TO BE ADDRESSED.CAPS INDICATE
 HOW COMMENTS ARE TO BE ADDRESSED
  
  
  
 02.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.ADD
 TO SHEET D-1
  
 03.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS
 SHALL BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT
 OR MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. ADD
 TO SHEET D-1
  
 04.THE DEMOLITION OF EXISTING AND/OR THE STOCKING OF
 NEW BUILDING MATERIALS & SUPPLIES SHALL NOT INTERFERE
 OR HINDER WITH ACCESS TO OR EXIT FROM THE STRUCTURE, OR
 THE VICINITY OF THE STRUCTURE (INCLUDING FIRE LANES).
 ADD TO SHEET D-1
  
 05.DISPLAY THE NUMERICAL ADDRESS ON THE APPROPIATE
 EXTERIOR ELEVATION FRONTING NORTHWOOD ROAD.AS PER
 WEST PALM BEACH CODE, NUMERALS SHALL BE NO LESS THAN 6"
 IN HEIGHT AND 1" IN WIDTH.INSERT THE ADDRESS NUMBER,
 SHEET A-2, FRONT ELEVATION
  
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS WHEN RESUBMITTING,
 INCLUDE A RESPONSE LETTER INDICATING HOW/WHERE EACH
 ITEM WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-02-06 Cont ID  
Sent By mawillia Date 2007-02-06 Time 18:29 Rev Time 0.00
Received By mawillia Date 2007-02-06 Time 18:29 Sent To  
Notes
2007-02-06 19:11:02*****DENIED*****
  
  
 01.THE 2003 EDITION OF NFPA 101, LIFE SAFETY CODE,
 SHALL BE REFERENCED.
  
 02.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 03.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS
 SHALL BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT
 OR MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION.
  
 04.THE DEMOLITION OF EXISTING AND/OR THE STOCKING OF
 NEW BUILDING MATERIALS & SUPPLIES SHALL NOT INTERFERE
 OR HINDER WITH ACCESS TO OR EXIT FROM THE STRUCTURE, OR
 THE VICINITY OF THE STRUCTURE (INCLUDING FIRE LANES).
  
 05.DISPLAY THE NUMERICAL ADDRESS ON THE APPROPIATE
 EXTERIOR ELEVATION FRONTING NORTHWOOD ROAD.AS PER
 WEST PALM BEACH CODE, NUMERALS SHALL BE NO LESS THAN 6"
 IN HEIGHT AND 1" IN WIDTH.
  
 06.INDICATE THE OCCUPANCY TYPE FOR THIS STRUCTURE.
 I.E. BUSINESS, MERCANTILE, ASSEMBLY, ETC.
  
 07.AS BASED UPON THE OCCUPANCY CLASSIFICATION, AN
 EXIT SIGN LIGHT (WITH BATTERY BACK-UP CAPABILITY) THAT
 IS READILY VISIBLE FROM ANY DIRECTION MAY BE REQUIRED.
 THE REQUIREMENT OF AN EXIT SHALL NOT APPLY TO EXISTING
 BUILDINGS, PROVIDED THAT THE OCCUPANCY CLASSIFICATION
 DOES NOT CHANGE.
  
 08.ARE THERE ANY FIRE SPRINKLER AND/OR FIRE ALARM
 SYSTEM FOR THIS STRUCTURE?IF SO, HOW WILL THEY BE
 AFFECTED BY THE SCOPE OF WORK?
  
 09.INDICATE LOCATION OF THE 2A:10BC FIRE
 EXTINGUISHER(S) WHICH SATISFIES THE 75' TRAVEL DISTANCE
 REQUIREMENT.
  
 10.INDICATE THE INTERIOR FINISH CLASSIFICATION FOR
 WALL AND CEILINGS IN THE EXITS, EXIT ACCESS CORRIDORS,
 AND IN ALL OTHER AREAS.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS WHEN RESUBMITTING,
 INCLUDE A RESPONSE LETTER INDICATING HOW/WHERE EACH
 ITEM WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2007-11-14 Cont ID  
Sent By adarroug Date 2007-11-14 Time 08:50 Rev Time 0.00
Received By adarroug Date 2007-11-14 Time 08:50 Sent To P
Notes
2007-11-14 08:50:26TO "KSTEVENS" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-08-07 Cont ID  
Sent By ssherman Date 2007-08-07 Time 17:35 Rev Time 0.00
Received By ssherman Date 2007-08-07 Time 17:35 Sent To B
Notes
2007-08-07 17:35:51TO JW DESK

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-08-07 Cont ID  
Sent By mmiller Date 2007-08-07 Time 17:34 Rev Time 0.00
Received By mmiller Date 2007-08-07 Time 17:33 Sent To M
Notes
2007-08-07 17:34:16SENT TO TOM GORDON'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-07-02 Cont ID  
Sent By adarroug Date 2007-07-02 Time 16:15 Rev Time 0.00
Received By adarroug Date 2007-07-02 Time 16:15 Sent To B
Notes
2007-07-02 16:15:57TO "JWITMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-05-03 Cont ID  
Sent By adarroug Date 2007-04-26 Time 16:27 Rev Time 0.00
Received By adarroug Date 2007-04-26 Time 16:27 Sent To  
Notes
2007-05-03 16:28:14TO "COMM" BD#23--EXPEDITED REVIEW--

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-04-26 Cont ID  
Sent By adarroug Date 2007-04-26 Time 15:59 Rev Time 0.00
Received By adarroug Date 2007-04-26 Time 15:59 Sent To  
Notes
2007-05-02 09:10:01TO "COMM" BD#23
2007-05-01 12:01:03 
  
 ***EXPEDITED PLAN REVIEW PER RB***
2007-05-01 11:03:22 
 5/1/07PLANS WITH JULIA BABCOCK FOR ZONING REVIEW.
 JULIA WILL RETURN TO AISHA UPON COMPLETION.
2007-04-26 15:59:54WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-03-22 Cont ID  
Sent By adarroug Date 2007-03-22 Time 11:32 Rev Time 0.00
Received By adarroug Date 2007-03-22 Time 11:32 Sent To  
Notes
2007-03-22 11:34:33TO "COMM" BD#7

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-02-06 Cont ID  
Sent By jbabcock Date 2007-01-31 Time 08:13 Rev Time 0.00
Received By mawillia Date 2006-12-20 Time 13:01 Sent To  
Notes
2007-01-11 10:22:44TO "COMM" BD#47
2006-12-20 13:02:16WAITING FOR "COMM" BD

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2007-08-08 Cont ID  
Sent By tgordon Date 2007-08-08 Time 08:21 Rev Time 0.25
Received By tgordon Date 2007-08-08 Time 08:21 Sent To  
Notes
2007-08-08 08:23:05REVISION TO MECH. PLAN PAGE MP-1.
 *** PROVISO ***
 1) PROVIDE 354 CFM'S OF OUTSIDE AIR, PER CONVERSATION
 WITH JEFFREY BRASSEUR.
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2007-05-11 Cont ID  
Sent By tgordon Date 2007-05-11 Time 08:03 Rev Time 0.20
Received By tgordon Date 2007-05-11 Time 08:03 Sent To E
Notes
2007-05-11 08:07:43*** PROVISO ***
 1) PROVIDE 354 CFM'S OF OUTSIDE AIR, PER CONVERSATION
 WITH JEFFREY BRASSEUR.
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2007-05-02 Cont ID  
Sent By tgordon Date 2007-05-02 Time 16:28 Rev Time 0.30
Received By tgordon Date 2007-05-02 Time 16:28 Sent To  
Notes
2007-05-02 16:39:58*** DENIED ***
 1) AS REQUESTED IN LAST REVIEW 4-5-07 NOTE #3, ENERGY
 CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT ALSO, PER
 2004 FBC 13-600.3.ABC.2.
  
 2) NEED OUTSIDE AIR CALCULATIONS, THE CALCULATIONS MAY
 BE PROVISO-ED IF YOU AGREE TO 354 CFM'S OUTSIDE AIR,
 AND THE ENERGY CAL'S ARE SIGNED, IF OTHER REVIEWS
 REQUIRE PLANS TO BE REDONE THEN PLEASE ADD THE OUTSIDE
 AIR CAL'S. TO THE REVISED MECHANICAL PLANS.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2007-04-05 Cont ID  
Sent By tgordon Date 2007-04-05 Time 12:10 Rev Time 0.30
Received By tgordon Date 2007-04-05 Time 12:10 Sent To  
Notes
2007-04-05 12:30:57*** DENIED ***
 1) COOLING LOAD CALCULATIONS ARE CALLING FOR 36,429
 SENSIBLE BTU'S (ESTIMATED 4 TONS), THE MECHANICAL PLANS
 ARE CALLING FOR A 2.5 TON A/C SYSTEM WHICH IS TO SMALL,
 THE PLANS CAN NOT CALL FOR LESS THAN THE COOLING LOAD
 CALCULATIONS, SEE 2004 FBC 13-607.1.ABC.1.1.
  
 2) PART OF THE ENERGY CALCULATIONS IS MISSING, PLEASE
 CORRECT.
  
 3)ENERGY CALCULATIONS NEED TO BE SIGNED BY
 OWNER/AGENT ALSO, PER 2004 FBC 13-600.3.ABC.2.
  
 4) RETURN AIR NEEDS TO BE PROVIDED FOR THE OFFICE, SEE
 2004 FBC/M 601.4.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-01-19 Cont ID  
Sent By tgordon Date 2007-01-19 Time 15:38 Rev Time 0.30
Received By tgordon Date 2007-01-19 Time 15:38 Sent To  
Notes
2007-01-19 15:42:32*** DENIED ***
 1) MECHANICAL PERMIT #06120557 APPLIED FOR BUT NO
 MECHANICAL PLANS WERE SUBMITTED FOR REVIEW. PLEASE
 SUBMIT MECHANICAL PLANS FOR REVIEW, PER 2004 FBC WPB
 AMEND. 106.3.5.1.4.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 4 Status P Date 2007-11-15 Cont ID  
Sent By jleech Date 2007-11-15 Time 08:47 Rev Time 0.00
Received By jleech Date 2007-11-15 Time 08:46 Sent To B
Notes
2007-11-15 08:51:08REVISED DRAWINGS WITH A LETTER. CHANGED BATHROOM WALL
 AND FLOOR FINISH FROM TILE TO CONCRETE CLEAR CEILER.

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-05-10 Cont ID  
Sent By kstevens Date 2007-05-10 Time 10:18 Rev Time 0.00
Received By kstevens Date 2007-05-10 Time 10:18 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-04-07 Cont ID  
Sent By kstevens Date 2007-04-07 Time 11:04 Rev Time 0.00
Received By kstevens Date 2007-04-07 Time 11:04 Sent To  
Notes
2007-04-07 11:13:22DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
 FBC-2004 CHAPTER 11
  
 FROM PREVIOUS REVIEW:
  
 1. OK
 2. OK
  
 3. SHT 1 TOILET ROOM SHALL BE ACCESSIBLE. SHOW THE
 FOLLOWING:
 A. OK
 B. OK
 C. OK
 D. OK
 E. 11-4.19.4 EXPOSED PIPES & SURFACES - ***NOT
 ADDRESSED
 F. 11-4.19.5 FAUCETS - ***NOT ADDRESSED
  
 4. OK
 5. OK
 6. OK
 7. OK.
  
 8. TABLE 403.1 A DRINKING FOUNTAIN IS REQUIRED, AND
 DEPENDING ON THE OCCUPANCY, A SERVICE SINK MAY BE
 REQUIRED.-OK, BUT A DETAIL SHOWING COMPLIANCE WITH
 SECTION 11-4.15 AND ALL SUBSECTIONS AS WELL AS SECTION
 11-4.15.1.3(10)(A) PROVISIONS FOR THOSE WHO HAVE
 DIFFICULTY BENDING OR STOOPING.
  
 9. SUBMIT A SANITARY RISER DIAGRAM. SHOW ALL PIPE
 SIZES, TRAPS AND VENTS. SECTION 106.3.5.1.3.-OK,
 BUT THE DRINKING FOUNTAIN IS NOT VENTED. SECTION
 901.2.1.
  
 10. OK
 11. OK
  
 **********NEW COMMENT***********
  
 1B. AN RPZV BACKFLOW IS REQUIRED ON THE WATER SERVICE
 TO THE BUILDING. IF EXISTING PLEASE INDICATE ON THE
 PLUMBING PLAN. SECTION 608.13.2.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-02-05 Cont ID  
Sent By kstevens Date 2007-02-05 Time 17:09 Rev Time 0.00
Received By kstevens Date 2007-02-05 Time 17:09 Sent To  
Notes
2007-02-05 17:34:42DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
 FBC-2004 CHAPTER 11
  
 1. SUBMIT AN EXISTING FLOOR PLAN SHOWING THE EXTENT OF
 THE DEMOLITION.SECTION 106.1
  
 2. INDICATE THE OCCUPANCE OF THE SPACE SO THAT MINIMUM
 FACILITIES CAN BE DETERMINED. TABEL 403.1.
  
 3. SHT 1 TOILET ROOM SHALL BE ACCESSIBLE. SHOW THE
 FOLLOWING:
 A. 11-4.16.2 CLEAR FLOOR SPACE
 B. 11-4.16.5 FLUSH CONTROLS
 C. 11-4.19.2 HEIGHT & CLEARANCES
 D. 11-4.19.3 CLEAR FLOOR SPACE
 E. 11-4.19.4 EXPOSED PIPES & SURFACES
 F. 11-4.19.5 FAUCETS
  
 4. THE WATER CLOSET SHALL BE 18" OFF THE WALL TO THE
 CENTERLINE OF THE FIXTURE. (FIG. 28).
  
 5. THE LAV SHALL BE A MINIMUM 15" OFF THE WALL TO THE
 CENTERLINE OF THE FIXTURE. (30" MINIMUM BETWEEN THE
 CENTERLINE OF THE W/C TO THE CENTERLINE OF THE LAV.).
 SECTION 405.3.1.
  
 6. THE TOILET ROOM SHALL SHOW AN UNOBSTRUCTED TURNING
 AREA. SECTION 11-4.22.3.
  
 7. THE TOILET ROOM DOOR SHALL NOT SWING INTO THE FLOOR
 SPACE REQUIRED FOR ANY DIXTURE. SECTION 11-4.23.2.
  
 8. TABLE 403.1 A DRINKING FOUNTAIN IS REQUIRED, AND
 DEPENDING ON THE OCCUPANCY, A SERVICE SINK MAY BE
 REQUIRED.
  
 9. SUBMIT A SANITARY RISER DIAGRAM. SHOW ALL PIPE
 SIZES, TRAPS AND VENTS. SECTION 106.3.5.1.3
  
 10. SUBMIT A WATER RISER DIAGRAM. SHOW ALL PIPE SIZES,
 VALVES, AND, IF REQUIRED, WATER HAMMER ARRESTORS.
 SECTIONS 106.3.5.1.3 & 604.9.
  
 11. THE WALLS OF ALL PUBLIC RESTROOMS SHAL BE SMOOTH,
 HARD & NONABSORBENT. SECTION 1210.2PLEASE SUBMIT A
 FINISH SCHEDULE INDICATING THE FINISH OF THE RESTROOM.
 SECTION 106.1.1.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 3 Status P Date 2007-05-01 Cont ID  
Sent By jbabcock Date 2007-05-01 Time 17:41 Rev Time 0.00
Received By jbabcock Date 2007-05-01 Time 17:41 Sent To I
Notes
2007-05-01 17:45:05PERMIT APPROVED WITH PROVISO, PLANTERS SHALL REMAIN OR
 BE INSTALLED IN THE FRONT FACADE. LANDSCAPE BUFFER (5
 FEET) AND GREEN AREA SHALL REMAIN AS SHOWN ON SITE PLAN
 (DATED 4/25/2007)

Review Stop Z ZONING
Rev No 2 Status F Date 2007-04-04 Cont ID  
Sent By jbabcock Date 2007-04-04 Time 16:25 Rev Time 0.00
Received By jbabcock Date 2007-04-04 Time 16:25 Sent To I
Notes
2007-04-04 16:27:51PLANNING AND ZONING ***FAILED***
  
 THE FOLLOWING COMMENTS WERE GENERATED FROM THE LAST
 REVIEW AND WERE NOT MET OR RESPONDED TO AS PART OF THE
 RESUBMITTAL:
  
  
 IN ADDITION TO THE ITEMS THAT SHALL BE RESUBMITTED,
 PLEASE RESPOND TO THE FOLLOWING COMMENTS IN WRITING:
  
 1.PROVIDE DIMENSIONS OF WINDOWS ON THE REVISED
 ELEVATIONS AND WHEREVER APPLICABLE.
  
 PURSUANT TO SECTION 94-213 D (5) STOREFRONTS ARE
 REQUIRED ON THE FRONTAGE LINES AND SHALL BE DIRECTLY
 ACCESSIBLE FROM SIDEWALKS. EACH STOREFRONT MUST HAVE
 CLEAR GLAZED AREAS, EQUAL TO A MINIMUM OF 70 PERCENT OF
 ITS FACADE, BETWEEN TWO AND EIGHT FEET FROM THE GROUND.
 IF THE COST OF A RENOVATION MEETS OR EXCEEDS 50 PERCENT
 OF THE ASSESSED VALUE PER THE COUNTY PROPERTY
 APPRAISER'S OFFICE OF THAT AFFECTED PORTION OF THE
 STRUCTURE PRIOR TO THE COMMENCEMENT THEREOF, THE
 RENOVATION MUST COMPLY WITH THE STOREFRONT CODE
 REQUIREMENT FOR CLEAR GLAZED AREAS.
  
 ACCORDING TO PALM BEACH COUNTY PROPERTY APPRAISER, THE
 ASSESSED VALUE OF THE PROPERTY AT 437 NORTHWOOD IS
 $90,703 WHILE THE ESTIMATED VALUE FOR THIS BUILDING
 PERMIT IS $135,650. THEREFORE, THE VALUE OF THE
 RENOVATION EXCEEDS 50 PERCENT OF THE ASSESSED VALUE PER
 THE COUNTY PROPERTY APPRAISER?S CALCULATION AND SECTION
 94-213 D (5) APPLIES.
  
 FURTHERMORE, THE PROPOSED WINDOWS ARE REQUIRED TO MEET
 ARCHITECTURAL STANDARDS PURSUANT TO SECTION 94-213 D
 (7), (8), (9), AND (13).
  
 2. PROVIDE SIGNED AND SEALED LANDSCAPING PLANS.
  
 PURSUANT TO SECTION 94-210 D (8)LANDSCAPE
 REGULATIONS: ALL PROPERTIES SHALL BE BROUGHT INTO
 COMPLIANCE WITH THE LANDSCAPE REGULATIONS PROVIDED IN
 THIS CHAPTER AT SUCH TIME THAT A BUILDING PERMIT IS
 ISSUED FOR WORK VALUED AT $5,000.00 OR MORE. THE
 PLANNING DIRECTOR SHALL HAVE AUTHORITY TO GRANT A
 ONE-TIME, THREE MONTH EXTENSION.
  
 PURSUANT TO SECTION 94-443 B (1)THE APPLICANT IS
 REQUIRED TO PROVIDE A LANDSCAPE BUFFER STRIP AT LEAST
 FIVE FEET WIDE ALONG THE ENTIRE EDGE OF PROPERTY WHEN
 ADJACENT TO A PUBLIC THOROUGHFARE, AND WHEN ADJACENT TO
 NONRESIDENTIAL ZONING DISTRICTS. AS SHOWN ON THE SITE
 PLAN, THERE IS LIMITED OPPORTUNITY FOR LANDSCAPING.
 REVIEW SECTION 94-442 FOR ALTERNATIVES.(SEE ARTICLE
 XIV FOR DETAILED LANDSCAPING SPECIFICATIONS).
  
 3. PROVIDE MECHANICAL EQUIPMENT DIMENSIONS ON SURVEY
 AND DETAIL OF SCREENING IN ORDER TO ILLUSTRATE THAT THE
 NEW EQUIPMENT WILL MEET THE LISTED REQUIREMENTS.
  
 THE PROPOSED MECHANICAL EQUIPMENT (NEW A/C COMP. AS
 SHOWN ON FLOOR PLAN) IS REQUIRED TO MEET SECTION 94-305
 (B)(4) MECHANICAL EQUIPMENT. MECHANICAL EQUIPMENT MAY
 NOT PROJECT MORE THAN FOUR FEET INTO A SETBACK. WINDOW
 AIR-CONDITIONING UNITS MAY NOT PROJECT MORE THAN 18
 INCHES INTO A REQUIRED SIDE SETBACK. IN ADDITION,
 MECHANICAL EQUIPMENT IS REQUIRED TO MEET SECTION 94-213
 (D)(15)MECHANICAL SYSTEMS AND SATELLITE AND
 COMMUNICATION DEVICES SHALL BE SCREENED FROM VIEW BY
 LANDSCAPING OR BUILT ELEMENTS DESIGNED AS AN INTEGRAL
 PART OF THE BUILDING ARCHITECTURE.
  
 4. PROVIDE PROPOSED FENCE DETAIL AS PART OF YOUR
 RESUBMITTAL.
  
 FENCING IS NOTED ON THE PERMIT DESCRIPTION BUT THERE
 ARE NO PLANS ILLUSTRATING THE PROPOSED FENCING. PLEASE
 NOTE THAT THE PROPOSED FENCE MUST MEET SECTION 94-213 D
 (3). THE EXISTING FENCE DOES NOT MEET CODE.
  
 5. PROVIDE INFORMATION ON THE PROPOSED USE THAT WILL
 OCCUPY THE STRUCTURE.
  
 6. IS SIGNAGE PROPOSED? IF SO, PLEASE BE ADVISED THAT
 ALL PROPOSED SIGNAGE MUST MEET THE STANDARDS OF SECTION
 94-213 (E)
  
 IF YOU NEED ADDITIONAL INFORMATION, CONTACT:
  
 JULIA BABCOCK
 PLANNER
 CITY OF WEST PALM BEACH
 (561)822-1442

Review Stop Z ZONING
Rev No 1 Status F Date 2007-01-31 Cont ID  
Sent By jbabcock Date 2007-01-31 Time 08:13 Rev Time 0.00
Received By jbabcock Date   Time   Sent To I
Notes
2007-01-31 08:12:06IN ADDITION TO THE ITEMS THAT SHALL BE RESUBMITTED,
 PLEASE RESPOND TO THE FOLLOWING COMMENTS IN WRITING.
  
 1.PROVIDE DIMENSIONS OF WINDOWS ON THE REVISED
 ELEVATIONS AND WHEREVER APPLICABLE.
  
 PURSUANT TO SECTION 94-213 D (5) STOREFRONTS ARE
 REQUIRED ON THE FRONTAGE LINES AND SHALL BE DIRECTLY
 ACCESSIBLE FROM SIDEWALKS. EACH STOREFRONT MUST HAVE
 CLEAR GLAZED AREAS, EQUAL TO A MINIMUM OF 70 PERCENT OF
 ITS FACADE, BETWEEN TWO AND EIGHT FEET FROM THE GROUND.
 IF THE COST OF A RENOVATION MEETS OR EXCEEDS 50 PERCENT
 OF THE ASSESSED VALUE PER THE COUNTY PROPERTY
 APPRAISER'S OFFICE OF THAT AFFECTED PORTION OF THE
 STRUCTURE PRIOR TO THE COMMENCEMENT THEREOF, THE
 RENOVATION MUST COMPLY WITH THE STOREFRONT CODE
 REQUIREMENT FOR CLEAR GLAZED AREAS.
  
 ACCORDING TO PALM BEACH COUNTY PROPERTY APPRAISER, THE
 ASSESSED VALUE OF THE PROPERTY AT 437 NORTHWOOD IS
 $90,703 WHILE THE ESTIMATED VALUE FOR THIS BUILDING
 PERMIT IS $135,650. THEREFORE, THE VALUE OF THE
 RENOVATION EXCEEDS 50 PERCENT OF THE ASSESSED VALUE PER
 THE COUNTY PROPERTY APPRAISER?S CALCULATION AND SECTION
 94-213 D (5) APPLIES.
  
 FURTHERMORE, THE PROPOSED WINDOWS ARE REQUIRED TO MEET
 ARCHITECTURAL STANDARDS PURSUANT TO SECTION 94-213 D
 (7), (8), (9), AND (13).
  
 2. PROVIDE SIGNED AND SEALED LANDSCAPING PLANS.
  
 PURSUANT TO SECTION 94-210 D (8)LANDSCAPE
 REGULATIONS: ALL PROPERTIES SHALL BE BROUGHT INTO
 COMPLIANCE WITH THE LANDSCAPE REGULATIONS PROVIDED IN
 THIS CHAPTER AT SUCH TIME THAT A BUILDING PERMIT IS
 ISSUED FOR WORK VALUED AT $5,000.00 OR MORE. THE
 PLANNING DIRECTOR SHALL HAVE AUTHORITY TO GRANT A
 ONE-TIME, THREE MONTH EXTENSION.
  
 PURSUANT TO SECTION 94-443 B (1)THE APPLICANT IS
 REQUIRED TO PROVIDE A LANDSCAPE BUFFER STRIP AT LEAST
 FIVE FEET WIDE ALONG THE ENTIRE EDGE OF PROPERTY WHEN
 ADJACENT TO A PUBLIC THOROUGHFARE, AND WHEN ADJACENT TO
 NONRESIDENTIAL ZONING DISTRICTS. AS SHOWN ON THE SITE
 PLAN, THERE IS LIMITED OPPORTUNITY FOR LANDSCAPING.
 REVIEW SECTION 94-442 FOR ALTERNATIVES.(SEE ARTICLE
 XIV FOR DETAILED LANDSCAPING SPECIFICATIONS).
  
 3. PROVIDE MECHANICAL EQUIPMENT DIMENSIONS ON SURVEY
 AND DETAIL OF SCREENING IN ORDER TO ILLUSTRATE THAT THE
 NEW EQUIPMENT WILL MEET THE LISTED REQUIREMENTS.
  
 THE PROPOSED MECHANICAL EQUIPMENT (NEW A/C COMP. AS
 SHOWN ON FLOOR PLAN) IS REQUIRED TO MEET SECTION 94-305
 (B)(4) MECHANICAL EQUIPMENT. MECHANICAL EQUIPMENT MAY
 NOT PROJECT MORE THAN FOUR FEET INTO A SETBACK. WINDOW
 AIR-CONDITIONING UNITS MAY NOT PROJECT MORE THAN 18
 INCHES INTO A REQUIRED SIDE SETBACK. IN ADDITION,
 MECHANICAL EQUIPMENT IS REQUIRED TO MEET SECTION 94-213
 (D)(15)MECHANICAL SYSTEMS AND SATELLITE AND
 COMMUNICATION DEVICES SHALL BE SCREENED FROM VIEW BY
 LANDSCAPING OR BUILT ELEMENTS DESIGNED AS AN INTEGRAL
 PART OF THE BUILDING ARCHITECTURE.
  
 4. PROVIDE PROPOSED FENCE DETAIL AS PART OF YOUR
 RESUBMITTAL.
  
 FENCING IS NOTED ON THE PERMIT DESCRIPTION BUT THERE
 ARE NO PLANS ILLUSTRATING THE PROPOSED FENCING. PLEASE
 NOTE THAT THE PROPOSED FENCE MUST MEET SECTION 94-213 D
 (3). THE EXISTING FENCE DOES NOT MEET CODE.
  
 5. PROVIDE INFORMATION ON THE PROPOSED USE THAT WILL
 OCCUPY THE STRUCTURE.
  
 6. IS SIGNAGE PROPOSED? IF SO, PLEASE BE ADVISED THAT
 ALL PROPOSED SIGNAGE MUST MEET THE STANDARDS OF SECTION
 94-213 (E)
  
 IF YOU NEED ADDITIONAL INFORMATION, CONTACT:
  
 JULIA BABCOCK
 PLANNER
 CITY OF WEST PALM BEACH
 (561)822-1442