Plan Review Details - Permit 06120539
Plan Review Stops For Permit 06120539
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-05-13 Cont ID  
Sent By rmcdouga Date 2009-05-13 Time 10:24 Rev Time 0.00
Received By rmcdouga Date 2009-05-13 Time 10:24 Sent To  
Notes
2009-05-13 11:21:38REVISED SHEETS 1 AND 3
  
 SEE PROVISO FROM REVIEW #2

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-06-29 Cont ID  
Sent By mjacobs Date 2007-06-29 Time 17:49 Rev Time 0.00
Received By mjacobs Date 2007-06-29 Time 16:58 Sent To PC
Notes
2007-06-29 17:25:26BUILDING PROVISO:
 TO BE IN PLACE AT C.O.:
  
 1) 424.2.17.1 OUTDOOR SWIMMING POOLS.
 OUTDOOR SWIMMING POOLS SHALL BE PROVIDED
 WITH A BARRIER COMPLYING WITH
 424.2.17.1.1 THROUGH 424.2.17.1.14.
  
 424.2.17.1.5 CHILD SAFETY BARRIER
 ASTM D5034 100 LB TENSILE STREGTH
 ASTM D3787 150 LB BALL BURST STRENGTH
  
 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED.
 SPAS AND HEATED SWIMMING POOLS SHALL BE
 EQUIPPED WITH A COVER DESIGNED TO
 MINIMIZE HEAT LOSS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-01-04 Cont ID  
Sent By mjacobs Date 2007-01-04 Time 09:59 Rev Time 0.00
Received By mjacobs Date 2007-01-04 Time 06:52 Sent To PC
Notes
2007-01-04 09:59:27BUILDING PLAN REVIEW
 PERMIT:06120539
 ADD:6678 HANNAH COVE
 CONT: OWNER
 TEL: (561)697-9288
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 1ST
 ACTION: DENIED
  
 1)ALL SWIMMING POOLS SHALL COMPLY WITH FBC-2004 SEC.
 424.2 AND SEC.R4101.
  
 2)THE CLAINED VALUAATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES,VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST EXCLUDING
 LAND VALUE. OUR VALUATION REFERENCE IS ICC (BVD),
 MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES PER
 108.3*.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2009-05-13 Cont ID  
Sent By rmcdouga Date 2009-05-13 Time 11:22 Rev Time 0.00
Received By rmcdouga Date 2009-05-13 Time 11:22 Sent To  
Notes
2009-05-13 11:23:16REVISED SHEETS 1 AND 3

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-06-22 Cont ID  
Sent By btrobaug Date 2007-06-18 Time 09:25 Rev Time 0.00
Received By btrobaug Date 2007-06-18 Time 15:52 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-01-03 Cont ID  
Sent By btrobaug Date 2007-01-03 Time 11:22 Rev Time 0.33
Received By btrobaug Date 2007-01-03 Time 11:13 Sent To P
Notes
2007-01-03 11:22:10 
  
 NONCOMPLIANT
  
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 PLEASE SUBMIT DETAILS FOR THE PANEL
 SHOWN ON THE SCHEMATIC, FEEDER AND CONDUIT SIZE AND
 TYPE, PANEL RATING AND OCP,
 PANEL SCHEDULE AND COMPUTED LOAD, ETC.
 IF AN ELECTRIC HEATER IS TO BE INSTALLED, PLEASE
 PROVIDE A CALCULATION INCLUDING ALL ADDED LOADS
 IMPOSED, ALL EXISTING
 LOADS AND THE EXISTING OR PROPOSED SERVICE
 SPECIFICATIONS PER 215.15.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
  
  
  

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2007-06-29 Cont ID  
Sent By mperson Date 2007-06-29 Time 15:31 Rev Time 0.00
Received By mperson Date 2007-06-29 Time 15:31 Sent To PC
Notes
2007-06-29 15:32:10NOTE: POOL HEATER IS AN ELECTRIC HEAT PUMP.

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2007-01-03 Cont ID  
Sent By mperson Date 2007-01-03 Time 14:15 Rev Time 0.00
Received By mperson Date 2007-01-03 Time 14:15 Sent To B
Notes
2007-01-03 14:20:55DENIED
 REFERENCE: FBC-2004 SEC. 424.2 OR FBC-2004 SEC. R4101
 SWIMMING POOLS
  
 PLEASE REFERENCE PLUMBING PLAN REVIEW COMMENTS #3, #4,
 AND #6
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2009-05-13 Cont ID  
Sent By rmcdouga Date 2009-05-13 Time 11:26 Rev Time 0.00
Received By rmcdouga Date 2009-05-13 Time 09:04 Sent To  
Notes
2009-05-13 09:05:34INCOMING TO RESIDENTIAL SWIMMING POOLS

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-09-07 Cont ID  
Sent By adarroug Date 2007-09-07 Time 10:21 Rev Time 0.00
Received By adarroug Date 2007-09-07 Time 10:21 Sent To P
Notes
2007-09-07 10:22:00TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-06-11 Cont ID  
Sent By adarroug Date 2007-06-11 Time 09:11 Rev Time 0.00
Received By adarroug Date 2007-06-11 Time 09:11 Sent To E
Notes
2007-06-11 09:12:10TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-06-08 Cont ID  
Sent By adarroug Date 2007-06-08 Time 11:13 Rev Time 0.00
Received By adarroug Date 2007-06-08 Time 11:13 Sent To Z
Notes
2007-06-08 11:13:43TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-12-28 Cont ID  
Sent By adarroug Date 2006-12-28 Time 08:53 Rev Time 0.00
Received By adarroug Date 2006-12-28 Time 08:53 Sent To E
Notes
2006-12-28 08:53:59TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-01-04 Time   Rev Time 0.00
Received By adarroug Date 2006-12-20 Time 11:40 Sent To  
Notes
2006-12-20 11:41:10TO "Z" BOX

Review Stop P PLUMBING
Rev No 4 Status P Date 2009-05-13 Cont ID  
Sent By rmcdouga Date 2009-05-13 Time 11:26 Rev Time 0.00
Received By rmcdouga Date 2009-05-13 Time 11:26 Sent To  
Notes
2009-05-13 11:26:41REVISED SHEETS 1 AND 3

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-09-25 Cont ID  
Sent By mperson Date 2007-09-25 Time 15:54 Rev Time 0.00
Received By mperson Date 2007-09-25 Time 15:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-06-29 Cont ID  
Sent By mperson Date 2007-06-29 Time 14:19 Rev Time 0.33
Received By mperson Date 2007-06-29 Time 14:19 Sent To G
Notes
2007-06-29 15:30:58DENIED 2ND TIME
 REFERENCE:
 ** FBC-2004 SECTION 424.2 OR R4101 SWIMMING POOLS **
 FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ARE STILL
 IN NEED OF ADDRESSING ALONG WITH SOME NEW COMMENTS,
 SOME BASED ON PLANS NOW SUBMITTED, NEW DOCUMENTS BEING
 REVIEWED FOR THE FIRST TIME AND SOME NEW COMMENTS NOT
 MADE ON PREVIOUS REVIEWS.
  
 ** PLEASE SEE THE NOTES BELOW ARE TAKEN DIRECTLY FROM
 PREVIOUS REVIEW WITH A NO, OK OR A NO/OK.
 THESE WILL BE FOR THE EXACT NUMERICAL NOTATION OF THE
 PREVIOUS REVIEW NOTES.
  
 A **NO** IS IF THE COMMENT WAS NOT FULLY ADDRESSED
 AND/OR FURTHER EXPLANATION OR CHANGES IN PLANS OR
 DOCUMENTS ARE STILL NEEDED. THIS REVIEWER WILL TRY TO
 BETTER EXPLAIN NOTE ABOVE PREVIOUS REVIEW COMMENT.
  
 AN **OK** WILL BE LABELED AS SUCH ON THE SAME NUMERICAL
 COMMENT AND WILL HAVE OLD NOTE REMOVED FROM COMMENTS.
  
 A **NO/OK** MEANS PART OF THE COMMENT MAY HAVE BEEN
 ADDRESSED, HOWEVER NOT ALL OF THE PREVIOUS REVIEW
 COMMENT MAY HAVE BEEN FULLY ADDRESSED.
  
 ** PLEASE SEE ANY NEW NOTES WILL BE ADDED TO THE END OF
 THE PREVIOUS REVIEW COMMENTS AND NOTED AS SUCH.
  
 1. **OK**
  
 2. **NO/OK** FBC-2004 SEC. 424.6.6 OR FBC-2004
 RESIDENTIAL SEC. R4101.6.6: ENTRAPMENT
 PROTECTION FOR SUCTION INLETS. PLEASE
 SUBMIT AN ENGINEERED TABLE FOR "VENT
 PIPE MAXIMUM LENGTH" INDICATING PUMP
 SIZES, AVERAGE FLOW, AND MAXIMUM LENGTH
 OF THE 1-1/2" PVC VENT PIPE, FROM
 WHERE IT STARTS TO WHERE IT ENDS UP,
 COMPLYING WITH THE THREE SECOND RELEASE.
 NOTE: THE RESUBMITTED TABLE IS OK FOR THE 1-1/2 HP
 FEATURE BUT DOES NOT PROVIDE FOR THE 2-1/2 HP
 RECIRCULATING PUMP.THE RESUBMITTED TABLE ONLY GOES TO
 2 HP.
  
 3 **NO** FBC-2004 SEC. 424.2.14.1, OR
 FBCR-2004 SEC. R4101.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. (MANUFACTURE
 SHEETS REQUIRED, PLEASE SUBMIT)
 NOTE: THE RESUBMITTED MANUFACTURER SHEETS DO NOT
 INDICATE AN INDICATION OF A RECOGNIZED TESTING AGENCY.
 ALSO AN ONLINE SEARCH FOR A LISTING OF THE HEAT PUMP
 CAME UP UNSUCCESSFUL.
  
 4 **OK**
  
 5. **OK**
  
 6. **OK**
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-01-03 Cont ID  
Sent By mperson Date 2007-01-03 Time 13:48 Rev Time 0.33
Received By mperson Date 2007-01-03 Time 13:48 Sent To G
Notes
2007-01-03 14:08:18DENIED
 REFERENCE: FBC-2004 SEC. 424.2 OR FBC-2004 SEC. R4101
 SWIMMING POOLS
  
 THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING
 PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1) COMPLY WITH FBC-2004 SEC 424.2, OR
 FBCR-2004 SEC R4101 PRIVATE SWIMMING
 POOLS. (PLEASE ADD TO NOTES)
  
 2) FBC-2004 SEC. 424.6.6 OR FBC-2004
 RESIDENTIAL SEC. R4101.6.6: ENTRAPMENT
 PROTECTION FOR SUCTION INLETS. PLEASE
 SUBMIT AN ENGINEERED TABLE FOR "VENT
 PIPE MAXIMUM LENGTH" INDICATING PUMP
 SIZES, AVERAGE FLOW, AND MAXIMUM LENGTH
 OF THE 1-1/2" PVC VENT PIPE, FROM
 WHERE IT STARTS TO WHERE IT ENDS UP,
 COMPLYING WITH THE THREE SECOND RELEASE.
  
 3) FBC-2004 SEC. 424.2.14.1, OR
 FBCR-2004 SEC. R4101.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. (MANUFACTURE
 SHEETS REQUIRED, PLEASE SUBMIT)
  
 4) FBC-2004 SEC. 424.2.14.2, OR
 FBCR-2004 SEC. R4101.14.2 WATER
 RETENTION, PROVIDE A POSITIVE MEANS OF
 RETAINING WATER IN THE HEATER WHEN PUMP
 IS SHUT OFF.(MANUFACTURE SHEETS
 REQUIRED, PLEASE SUBMIT)
  
 5) PLEASE IDENTIFY THE VACUUM, SKIMMER, AND FEATURE
 PUMP MAIN DRAINS IN POOL AND PLEASE ADD FEATURE PUMP TO
 POOL DATA.
  
 6) PLEASE NOTE ON RESUBMITTAL IF HEAT PUMP IS GAS OR
 ELECTRIC.
  
 ***IMPORTANT INFORMATION
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2007-06-08 Cont ID  
Sent By choops Date 2007-06-08 Time 15:59 Rev Time 0.00
Received By choops Date 2007-06-08 Time 15:59 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2006-12-27 Cont ID  
Sent By mmclean Date 2006-12-27 Time 14:24 Rev Time 0.00
Received By mmclean Date 2006-12-27 Time 14:24 Sent To I
Notes
2006-12-27 14:29:12DENIED,
 1. PLEASE SUBMIT TWO COPIES OF SURVEYS SHOWING THE
 PROPOSED POOL AND DECK WITH SETBACKS.(FROM WATER'S EDGE
 TO PROPERTY LINE AND DECK TO PROPERTY LINE).
 2. NO SURVEYS WERE SUBMITTED AND POOL PLANS IS
 INSUFFICENT FOR A COMPLETE ZONING REVIEW.
 3. SEC094-304(B), EVERY SWIMMINGPOOL SHALL BE
 ENCLOSED BY A FENCE OR SIMILIAR STRUCTURE WHICH IS
 INSTALLED TO OBSTRUCT ACCESS BY PERSONS OTHER THAN THE
 OWNERS OR OCCUPANTS OF THE RESIDENCE WITHIN WHICH
 SWIMMING POOL IS LOCATED.BARRIERS OR FENCES SHALL BE
 AT LEAST FOUR FEET IN HEIGHT ABOVE GRADE.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720
  