| Plan Review Stops For Permit 06120465 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-11-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-11-26 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-11-26 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2007-11-26 16:38:15 | REVISIONS TO SHEETS A-1 AND A-2 REMOVING THE WASHER, | | | DRYER AND TANKLESS WATER HEATER AND RELATED PLUMBING | | | AND ELECTRIC. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2007-11-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-11-14 |
Time |
18:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-11-14 |
Time |
18:26 |
Sent To |
P |
|
| Notes |
| 2007-11-14 18:43:30 | 2004 FBC | | | REVISED SHEETS A-1 AND A-2. | | | | | | DENIED BY BUILDING | | | | | | 1) THE INTENTION OF THE REVISED PLANS THAT WERE | | | SUBMITTED IS TO DELETE CERTAIN ITEMS IN THE LAUNDRY | | | ROOM ADDITION FROM THE SCOPE OF WORK. HOWEVER, THE | | | ITEMS THAT WERE TO BE ELIMINATED ARE STILL SHOWN ON THE | | | DRAWINGS. THE PROPER WAY TO SHOW THIS ON THE PLANS IS | | | TO BLANK OUT THE ITEM AND CLOUD AND NUMBER THE AREA | | | WHERE THE ITEM WAS SHOWN ON THE PLAN THAT IS BEING | | | CHANGED. FBC 106.1* CITY AMENDMENTS. PLEASE CORRECT. | | | | | | - ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-06-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-06-12 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-06-12 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2007-06-12 15:22:40 | BUILDING PROVISO | | | | | | PRIOR TO INSTALLATION, SUBMIT RAS 117 CALCULATIONS FOR | | | THE ENHANCED FASTENING AT THE PERIMETER AND CORNER ROOF | | | AREAS FOR THE FIRESTONE MODIFIED ROOF SYSTEM (NOA | | | 05-0830.10). THE INFORMATION THAT WAS SUBMITTED IS NOT | | | ACCEPTABLE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-03-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-03-27 |
Time |
17:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-03-27 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2007-03-27 17:41:37 | DENIED BY BUILDING (2ND REVIEW) | | | | | | 1) ALL OF THE ROOF SHEATHING IS REQUIRED TO BE FASTENED | | | WITH 8D RING SHANK NAILS. PLEASE REVISED NOTES ON A2 TO | | | SPECIFY 8D RING SHANK NAILS. | | | | | | 2) THE DRAINAGE PLAN IS REQUIRED TO SHOW THAT THE | | | SURFACE DRAINAGE WILL BE ROUTED TO THE STORM DRAIN OR | | | OTHER APPROVED COLLECTION POINT AND NOT ONTO ADJACENT | | | LOTS. | | | | | | 3)SHOW COMPLIANCE WITH R310.4 FOR EMERGENCY EGRESS | | | WHEN STORM PANELS ARE INSTALLED. | | | R310.4 REQUIRES AT LEAST ONE | | | MEANS OF ESCAPE FROM A DWELLING WHEN | | | SHUTTERED FOR IMPACT PROTECTION. THE | | | MEANS OF ESCAPE SHALL BE WITHIN THE | | | FIRST FLOOR OF THE DWELLING AND CAN NOT | | | BE LOCATED IN A GARAGE. OCCUPANTS IN ANY | | | PART OF THE DWELLING SHALL HAVE ACCESS | | | TO IT WITHOUT HAVING TO PASS THROUGH A | | | LOCKABLE DOOR NOT UNDER THEIR CONTROL. | | | INDICATE HOW COMPLIANCE WILL BE | | | ACHIEVED. | | | | | | 4) THE DESIGN PRESSURE FOR THE SELECTED FIRESTONE | | | MODIFIED ROOF SYSTEM IS 52.5 PSF, WHICH IS TOO LOW FOR | | | ROOF ZONES 2 AND 3. SUBMIT RAS 117 CALCULATIONS FOR | | | INCEASED FASTENER DENSITIES FOR THESE AREAS AS ALLOWED | | | BY GENERAL LIMITATION NUMBER 7 ON PAGE 34 OF THE NOA. | | | | | | 5) GLASS BLOCK INSTALLED WITH MORTAR IN ACCORDANCE WITH | | | FBC SECTION 2110 IS NOT REQUIRED TO BE PROTECTED WITH | | | STORM PANELS. | | | | | | 6) THE STORM PANEL INSTALLATION SCHEDULE SUBMITTED | | | CONTAINS SOME ERRORS. THE CALK-IN ANCHORS ARE REQUIRED | | | TO HAVE A 7/8 " EMBEDMENT, NOT 1/8". THE EDGE DISTANCE | | | REFERS TO THE SPACE BETWEEN THE EDGE OF THE OPENING AND | | | THE STORM PANEL ANCHORS. THE FASTENER SPACING IS | | | RELATED TO THE EDGE DISTANCE. SEE THE ANCHOR SPACING | | | TABLES IN THE PRODUCT APPROVAL. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-01-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-01-30 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-01-30 |
Time |
06:46 |
Sent To |
|
|
| Notes |
| 2007-01-30 12:00:03 | DENIED BY BUILDING | | | | | | 1)EXISTING COMPUTER ROOM/ BEDROOM MUST COMPLY WITH | | | R310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. BASEMENTS | | | WITH HABITABLE SPACE AND EVERY SLEEPING ROOM SHALL HAVE | | | AT LEAST ONE OPENABLE EMERGENCY ESCAPE AND RESCUE | | | OPENING. | | | IF COMPUTER ROOM IS NOT USED AS A SLEEPING ROOM, THIS | | | MUST BE SPECIFIED ON THE PLANS. | | | | | | 2)ROOF SHEATHING IS REQUIRED TO BE IN ACCORDANCE WITH | | | SECTION R803.2.3.1 OF 2006 REVISIONS TO 2004 FBC | | | RESIDENTIAL CODE. WOOD STRUCTURAL PANEL SHEATHING SHALL | | | BE FASTENED TO ROOF FRAMING WITH 8D RING-SHANK NAILS AT | | | 6 INCHES ON CENTER AT EDGES AND 6 INCHES ON CENTER AT | | | INTERMEDIATE FRAMING. SPACING OF RING-SHANK FASTENERS | | | SHALL BE 4 INCHES ON CENTER IN NAILING ZONE 3 FOR 130 | | | MPH OR GREATER DESIGNWIND SPEEDS IN ACCORDANCE WITH | | | FIGURE R803.2.3.1. PLEASE REVISE NOTES ON A2. | | | | | | 3)SPECIFY THE REQUIRED DESIGN LOADS FOR THE TRUSS TOP | | | AND BOTTOM CORDS ON THE PLANS. FBC 106.1.2 | | | | | | 4) SUBMIT A DRAINAGE PLAN SHOWING COMPLIANCE WITH | | | R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS | | | TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO | | | DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE | | | GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM | | | OF 6 INCHES (152 MM) WITHIN THE FIRST 10 FEET (3048 | | | MM). | | | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER | | | PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL | | | WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE | | | PROVIDED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. | | | | | | 5) SHOW COMPLIANCE WITH R807.1 ATTIC ACCESS . | | | IN BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF | | | CONSTRUCTION, AN ATTIC ACCESS OPENING SHALL BE PROVIDED | | | TO ATTIC AREAS THAT EXCEED 30 SQUARE FEET (2.8 M 2 ) | | | AND HAVE A VERTICAL HEIGHT OF 30 INCHES (762 MM) OR | | | GREATER. | | | THE ROUGH-FRAMED OPENING SHALL NOT BE LESS THAN 22 | | | INCHES BY 30 INCHES (559 MM BY 762 MM) AND SHALL BE | | | LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE | | | LOCATION. A 30-INCH (762 MM) MINIMUM UNOBSTRUCTED | | | HEADROOM IN THE ATTIC SPACE SHALL BE PROVIDED AT SOME | | | POINT ABOVE THE ACCESS OPENING. SEE SECTION M1305.1.3 | | | FOR ACCESS REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS | | | LOCATED IN ATTICS. | | | | | | 6) THE PRODUCT APPROVALS FOR THE DOUBLE OUTSWING FRONT | | | DOORS DO NOT HAVE GLAZING IN THE DOORS. THE PLANS SHOW | | | DOORS WITH GLAZING. PLEASE CLARIFY. | | | | | | 7) SPECIFY THE OPENING PRESSURES FOR THE NEW DOOR TO | | | THE LAUNDRY/STORAGE ROOM ON THE PLANS. | | | | | | 8) INDICATE WHICH ONE OF THE APPROVED SYSTEMS FROM THE | | | FIRESTONE MODIFIED ROOF SYSTEM NOA WILL BE INSTALLED. | | | PLEASE CIRCLE THE APPROPRIATE ONE. ALSO CIRCLE THE | | | FASTENING OPTION AND MAXIMUM DESIGN PRESSURE FOR THE | | | SELECTED SYSTEM. SUBMIT RAS 117 CALCULATIONS FOR THE | | | ENHANCED FASTENING REQUIREMENTS AT PERIMETER AND CORNER | | | AREAS, WHICH IS ALLOWED BY LIMITATION #7. | | | | | | 9) SUBMIT A KEY PLAN AND INSTALLATION SCHEDULE | | | SPECIFING THE OPENINGS THAT WILL BE SHUTTERED. SPECIFY | | | THE FASTENER TYPE AND SPACING, THE OPENING SIZES, THE | | | SPANS, EDGE DISTANCE, THE CONNECTION TYPE, PRESSURE, | | | ETC. | | | | | | 10)SUBMIT ENERGY CALCULATIONS AS REQUIRED BY 2OO4 FBC | | | CHAPTER 13. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2007-11-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-26 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-26 |
Time |
10:42 |
Sent To |
P |
|
| Notes |
| 2007-11-26 10:55:17 | SA'S AS REQUIRED PER FBC R313 ARE ON A SEPARATE STAMPED | | | SHEET. | | | NFPA-72 11.5.1.1.1 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-11-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-09 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-09 |
Time |
12:33 |
Sent To |
P |
|
| Notes |
| 2007-11-09 12:33:30 | ** PROVISO ** | | | | | | 1) NOTE:PLANS SUBMITTED FOR REVISION #3 DO NOT | | | INDICATE THE SCOPE OF WORK FOR DELETION OF TANK-LESS | | | WATER HEATER. AS PER OWNER AND SPOKE TO ARCHITECT, THE | | | TANK-LESS WATER HEATER ALONG WITH WASHER, DRYER AND | | | SINK ARE NO LONGER IN SCOPE OF WORK TO BE DONE. NO | | | ROUGH IN OR STUB OUTS FOR THESE ITEMS. | | | ** PLANS WILL STILL NEED TO BE REVISED FOR ALL ITEMS AS | | | PANEL SCHEDULE AND PLANS STILL CALL FOR WORK TO BE | | | DONE, NOT ALL WAS DELETED. *EXAMPLE TANK-LESS WH. | | | | | | 2) NOTE: THE PREVIOUS STAMPED PLANS STILL CONTAIN AN | | | ATTACHMENT FOR THE EXISTING DWELLING TO COMPLY WITH FBC | | | R313 AND NFPA-72 11.5.1.1.1 FOR SMOKE ALARMS. | | | | | | ** THESE ABOVE ITEMS SHALL ALL BE REVISED ON PLANS AND | | | SUBMITTED FOR REVIEW AND STAMPING BEFORE FINAL | | | INSPECTIONS. | | | PLANS MUST BE ON SITE FOR ALL INSPECTIONS. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTIONS SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-11-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-02 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-02 |
Time |
12:30 |
Sent To |
P |
|
| Notes |
| 2007-11-02 12:30:52 | | | | ** DENIED REVISION ** | | | | | | 1) NOTE: PLEASE SUBMIT REVISIONS WHICH INDICATE THE | | | ACTUAL ITEMS BEING REVISED. PLEASE SEE THE REVISION | | | COVER SHEET MENTIONS THE CONNECTIONS TO THE WASHER AND | | | DRYER ARE BEING DELETED, HOWEVER PLANS STILL INDICATE | | | THE NEW WASHER AND DRYER? | | | IT IS UNCLEAR WHAT IS BEING REVISED. | | | | | | 2) NOTE: PLEASE SEE THE PLANS SUBMITTED NEED TO HAVE | | | BOTH SETS SIGNED, DATED AND SEALED BY THE ARCHITECT OF | | | RECORD. | | | PLEASE SEE OF THE THREE SUBMITTED ONLY ONE CONTAINS AN | | | ORIGINAL SIGNATURE AND SEAL. | | | FBC ADMIN SECTION 106.1, 106.5. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH. | | | | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-05-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-05-11 |
Time |
12:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-05-11 |
Time |
11:55 |
Sent To |
P |
|
| Notes |
| 2007-05-11 12:21:46 | REDLINED 110.26 FOR TKLESS WH DISCONNECT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-03-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-24 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-24 |
Time |
11:08 |
Sent To |
P |
|
| Notes |
| 2007-03-24 11:39:19 | | | | | | | ****** UNSAT 2ND REVIEW****** | | | | | | ** PLEASE KNOW THAT ANY REFERENCE TO THE FBC CHAPTER 1 | | | IN THE PLAN REVIEW COMMENTS CAN BE FOUND IN THE | | | ADMINISTRATIVE SECTION OF THE 2004 FBC AS ADOPTED BY | | | THE CITY OF WEST PALM BEACH. | | | | | | 1) NOTE: PLEASE SEE MISSING DISCONNECT FOR THE NEW | | | TANKLESS WATER HEATER PER 422.30,31. | | | PLEASE SEE 110.26 FOR CLEARANCE. | | | | | | 2) NOTE: PLEASE SEE THE FBC 2004 R313.1.1 AS SMOKE | | | ALARMS ARE REQUIRE INSIDE AND OUTSIDE ALL SLEEPING | | | ROOMS. THE 2004 FBC W/ THE 2006 REVISION WAS CHANGED TO | | | REQUIRE THESE EVEN WHEN NOT DOING WORK INSIDE THE | | | EXISTING DWELLING. | | | PLEASE SHOW ON A LAYOUT OF THE EXISTING DWELLING. THESE | | | SHALL BE SHOWN AS SA FOR SMOKE ALARMS NOT SD. SMOKE | | | DETECTORS ARE DEVICES WHICH ONLY DETECT THE SMOKE AND | | | DO NOT SOUND AN ALARM. | | | SEE NFPA-72 DEFINITIONS. | | | PLEASE SEE NFPA-72 11.5.1.1.1, AND 11.8.3 FOR | | | PLACEMENT. | | | | | | 3) NOTE: PLEASE SEE THE RECEPTACLE FOR THE WASHER AS IT | | | IS WITHIN 6FT OF THE LAUNDRY SINK SHALL BE GFI | | | PROTECTED EVEN IF THIS IS A DEDICATE DEVICE.PLEASE | | | SEE THAT THIS IS REQUIRED FOR ALL RECEPTACLES WITHIN | | | 6FT OF LAUNDRY TUB WHICH ARE 15/20AMP AND 125V. | | | THIS HAS CHANGED IN THE 2005 NEC.210.8A7 | | | | | | | | | ** PLEASE CALL TO OVER COMMENTS ONCE ALL OTHER TRADES | | | ARE COMPLETED ON THEIR REVIEW. IF ALL OTHER TRADES ARE | | | OK, THEN THIS MAY BE SET UP AS A * PROVISO* WHICH | | | PERMITS ISSUANCE OF PERMIT AND REVISED PLANS WILL BE | | | REQUIRED BEFORE INSPECTION. | | | IF PLANS COME BACK WITH ANY COMMENTS FROM OTHER TRADES | | | FOR ANY REASON, PLEASE MAKE CORRECTIONS AT THIS TIME. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-03-24 11:08:57 | FROM ZONING ON 3/21 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-12-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-29 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-29 |
Time |
07:01 |
Sent To |
M |
|
| Notes |
| 2006-12-29 07:52:03 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE INDICATE ON PANEL SCHEDULE ALL NEW AND | | | EXISTING CIRCUITS AS SOME ITEMS ON PLANS ARE SHOWN AS | | | NEW AND PANEL SCHEDULE SHOWS THEM AS NEW , YET SOME | | | ITEMS ON PLANS APPEAR TO BE SHOWN NEW , YET PANEL | | | SCHEDULE DOES NOT SHOW THESE AS NEW? | | | PLEASE ALSO CLARIFY NEW SMALL APPLIANCE CIRCUIT BEING | | | SHOWN ON PANEL SCHEDULE. PLEASE SEE THIS IS BEING | | | SHOWN, YET NO WORK IS BEING SHOWN IN ANY AREAS WHICH | | | WOULD CONSIDER THIS AS A SMALL APPLIANCE CIRCUIT. | | | PLEASE SEE 210.52B1 | | | PLEASE ALSO SEE 408.4. | | | | | | 2) NOTE: PLEASE SUBMIT THE MANUFACTURES SPEC/CUT SHEETS | | | FOR THE NEW TANK LESS WATER HEATER. PLEASE BE SURE IT | | | CONTAINS A LISTING FROM NATIONALLY RECOGNIZED TESTING | | | LABORATORY AS REQUIRED PER 110.3, 90.7. | | | FBC ADMIN SECTION 106.1.2. | | | | | | 3) NOTE: PLEASE LIST THE 2005 NEC ON PLANS. PLEASE KNOW | | | AS INFORMATIONAL PURPOSE THE STATE ADOPTED THE NEW | | | REVISIONS TO THE 2004 FBC AND THE NEW NFPA-70 (NEC) | | | 2005 AS OF DECEMBER 8, 2006. ALL PERMIT APPLICATIONS | | | MADE AFTER THIS DATE WILL BE UNDER THESE NEW CODES. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-11-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-21 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-21 |
Time |
10:23 |
Sent To |
E |
|
| Notes |
| 2007-11-21 10:23:40 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-10-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-31 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-31 |
Time |
16:51 |
Sent To |
E |
|
| Notes |
| 2007-10-31 16:52:49 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-05-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-05-09 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-05-09 |
Time |
16:37 |
Sent To |
E |
|
| Notes |
| 2007-05-09 16:37:56 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-05-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-05-03 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-05-03 |
Time |
11:03 |
Sent To |
Z |
|
| Notes |
| 2007-05-03 11:04:08 | TO "Z" BOX/RESUB--NEW SHEETS FOR "Z" AND "P" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-03-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-22 |
Time |
08:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-22 |
Time |
08:09 |
Sent To |
E |
|
| Notes |
| 2007-03-22 08:09:36 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-03-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-15 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-15 |
Time |
11:53 |
Sent To |
Z |
|
| Notes |
| 2007-03-15 11:54:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-12-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-28 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-28 |
Time |
11:10 |
Sent To |
E |
|
| Notes |
| 2006-12-28 11:11:01 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-01-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-01-30 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-12-18 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2006-12-18 11:38:26 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2007-01-02 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-01-02 |
Time |
09:39 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2007-01-02 |
Time |
09:39 |
Sent To |
P |
|
| Notes |
| 2007-01-02 09:40:40 | NO MECHANICAL PLANS SUBMITTED, AND NO | | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | | THIS TIME. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
N |
Date |
2007-11-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-11-16 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-11-16 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2007-11-16 09:57:39 | PLUMBING SCOUP OF WORK WAS DELETED FROM PLANS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-05-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-05-16 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-05-16 |
Time |
09:18 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-03-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-03-27 |
Time |
07:25 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-03-27 |
Time |
07:25 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2007-01-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-01-06 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-01-06 |
Time |
12:02 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-05-07 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-05-07 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-05-04 |
Time |
15:36 |
Sent To |
I |
|
| Notes |
| 2007-05-07 15:36:38 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-03-21 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-03-21 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-03-21 |
Time |
08:44 |
Sent To |
I |
|
| Notes |
| 2007-03-21 09:00:06 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-12-27 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-12-27 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-12-27 |
Time |
07:59 |
Sent To |
I |
|
| Notes |
| 2006-12-27 08:01:52 | DENIED, | | | 1. THE SURVEYS SUBMITTED DOES NOT PROVIDE THE SIDE | | | SETBACK. | | | 2. PLEASE MARK ON THE TWO COPIES OF SURVEYS THE | | | DISTANCE OF THE NEW ADDITION FROM SIDE PROPERTY LINE. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|