| Plan Review Stops For Permit 06120464 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-03-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-03-14 |
Time |
17:29 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-03-14 |
Time |
14:42 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-02-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-02-09 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-02-09 |
Time |
10:38 |
Sent To |
PC |
|
| Notes |
| 2007-02-09 16:06:50 | BUILDING PLAN REVIEW | | | PERMIT: | | | ADD: | | | CONT: | | | TEL: (561)###-#### | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2)SHEET A-4SHOWS 5/8" AND 3/4" PLYWOOD, INDICATE | | | WHICH ONE WILL BE USED. SEE DETAIL #2 AND #3 ON SHEET | | | A-4. | | | | | | 3)THE PRODUCT APPROVAL FOR THE SHUTTERS SHALL | | | INDICATE WHICH MATERIALS WILL BE USED. CIRCLE OR | | | HI-LIGHT ALL ITEMS FROM THE PACKAGE. | | | | | | 4)R802.1.6TRUSS DESIGN DRAWINGS, PREPARED IN | | | CONFORMANCE WITH SECTION R802.1.6.1 SHALL E PROVIDED TO | | | THE BUILDING OFFICIAL AND APPROVED PRIOR TO | | | INSTALLATION. SEE THIS SECTION FOR MORE INFORMATION. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-08-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-10 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-09 |
Time |
14:49 |
Sent To |
PC |
|
| Notes |
| 2007-08-10 09:06:36 | REV OK, | | | SERVICE IS SHOWN AS EXISTING. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-03-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-09 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-09 |
Time |
16:03 |
Sent To |
P |
|
| Notes |
| 2007-03-09 17:30:58 | ELEC SERVICE IS EXISTING, NO NEW SERVICE WORK ONLY NEW | | | CIRCUITS FROM EXISTING EELCTRICAL PANEL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-12-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-29 |
Time |
07:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-28 |
Time |
18:55 |
Sent To |
P |
|
| Notes |
| 2006-12-29 07:18:51 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE SEE PLANS INDICATE A NEW SERVICE | | | HOWEVER PLEASE CORRELATE AND COMPLETE AS NEEDED. | | | PLEASE SEE RISER IS MISSING THE AIC RATINGS FOR ALL NEW | | | SERVICE EQUIPMENT. 110.9 | | | PLEASE SEE RISER SHOWS A 200A MAIN DISCONNECT PANEL | | | WITH A FEED TO THE 125A PANEL B, YET THIS PANEL B IS | | | ALSO BEING SHOWN BEING FED FROM THE METER ALSO? PLEASE | | | CLARIFY. | | | PLEASE SEE IF INDEED THIS 125A PANEL IS FED FROM THE | | | MAIN PANEL, PLEASE COMPLETE RISER WITH THE FEEDERS, | | | EQUIPMENT GROUNDING ETC. 215.5, 250.110, 250.24, | | | 250.122 ETC | | | PLEASE SEE MISSING THE LOCATION OF WHAT IS BEING SHOWN | | | AS A NEW SERVICE. 110.26, 240.24, 408.7 ETC. | | | | | | 2) NOTE: PLEASE SEE THE LOAD CALCULATIONS ARE SUBMITTED | | | FOR THE EXISTING DWELLING HOWEVER THE NEW LOADS | | | INCLUDING THE NEW REQUIRED CIRCUIT FOR THE GDO/ GARAGE | | | DOOR OPENER IS NOT INCLUDED IN THE CALCULATIONS. | | | PLEASE SUBMIT THE PANEL SCHEDULE IN WHICH THESE WILL BE | | | CIRCUITED FROM SHOWING THE MINIMUM BRANCH CIRCUIT SIZE | | | WITH THE CONDUCTOR SIZE(S) AND THE OVER CURRENT | | | PROTECTION ON CIRCUIT. | | | | | | 3) NOTE: PLEASE LIST THE 2005 NEC ON PLANS. PLEASE KNOW | | | AS INFORMATIONAL PURPOSE THE STATE ADOPTED THE NEW | | | REVISIONS TO THE 2004 FBC AND THE NEW NFPA-70 (NEC) | | | 2005 AS OF DECEMBER 8, 2006. ALL PERMIT APPLICATIONS | | | MADE AFTER THIS DATE WILL BE UNDER THESE NEW CODES. | | | | | | | | | ** PLEASE KNOW THERE ARE SOME UNANSWERED QUESTIONS | | | BASED ON THE RISER SUBMITTED. | | | ** PLEASE CALL IF THERE ARE ANY QUESTIONS, COMMENTS OR | | | IF ANY PART OF THESE NOTES ARE NOT CLEAR IN ANY WAY. | | | | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-08-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-03 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-03 |
Time |
16:32 |
Sent To |
E |
|
| Notes |
| 2007-08-03 16:33:29 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-03-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-09 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-09 |
Time |
11:17 |
Sent To |
E |
|
| Notes |
| 2007-03-09 11:17:36 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-03-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-01 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-01 |
Time |
15:59 |
Sent To |
Z |
|
| Notes |
| 2007-03-01 15:59:23 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-12-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-28 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-28 |
Time |
11:05 |
Sent To |
E |
|
| Notes |
| 2006-12-28 11:06:02 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2007-02-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-17 |
Time |
17:33 |
Sent To |
|
|
| Notes |
| 2006-12-17 17:33:59 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2007-01-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-01-06 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-01-06 |
Time |
10:57 |
Sent To |
B |
|
| Notes |
| 2007-01-06 10:58:26 | NO A/C WORK SHOWN ON THIS PLAN |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-03-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-03-14 |
Time |
07:23 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-03-14 |
Time |
07:23 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-01-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-01-06 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-01-06 |
Time |
10:50 |
Sent To |
B |
|
| Notes |
| 2007-01-06 10:56:53 | NO PLUMBING WORK SHOWN ON THIS PLAN. PLUMBING | | | CONTRACTOR SIGNED ON BUILDING PERMIT APPLICATION. SHOW | | | PLUMBING WORK TO BE DONE ON PLANS OR REMOVE FOSTER | | | PLUMBING FROM PERMIT APPLICATION. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-03-07 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2007-03-07 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2007-03-07 |
Time |
12:24 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-12-26 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-12-26 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
MMCLEAN |
Date |
2007-03-07 |
Time |
12:23 |
Sent To |
I |
|
| Notes |
| 2006-12-26 17:38:34 | DENIED, PARCEL B-2 | | | 1. PLEASE PROVIDE TWO COPIES OF SURVEYS SHOWING THE | | | PROPOSED GARAGE WITH SETBACKS. | | | 2. THE SITEPLAN SUBMITTED IS INSUFFICIENT FOR A | | | COMPLETE REVIEW. SITEPLANS MUST SHOW ALL THAT IS | | | EXISTING ON THE PROPERTY WITH SETBACKS. | | | 3. PLEASE SHOW ANY NEW A/C UNITS FOR THE PROPERTY ON | | | THE TWO COPIES OF SURVEYS. | | | 4. PLEASE SHOW THE NEW PAVERS FOR DRIVEWAY ON THE TWO | | | COPIES OF SURVEYS. | | | | | | NOTE: THE ROOF MUST FOLLOW THE GUIDELINES APPROVED, | | | PITCH 5/12MIN. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|