Plan Review Details - Permit 06120446
Plan Review Stops For Permit 06120446
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-12-17 Cont ID  
Sent By rmcdouga Date 2007-12-17 Time 08:39 Rev Time 0.00
Received By rmcdouga Date 2007-12-17 Time 07:06 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-10-11 Cont ID  
Sent By rmcdouga Date 2007-10-11 Time 14:17 Rev Time 0.00
Received By rmcdouga Date 2007-10-11 Time 14:17 Sent To  
Notes
2007-10-11 13:47:592004 FBC
 ENCLOSE CARPORT
  
 DENIED BY BUILDING
  
 1)713.13(2) F.S.THE NOTICE OF
 COMMENCEMENT MUST BE RE-RECORDED BECAUSE
 THE DESCRIBED IMPROVEMENT OR
 CONSTRUCTION DID NOT COMMENCE WITHIN 90
 DAYS OF RECORDING.
  
 2) IMPACT FEES. THE PLANS SHALL BE TAKEN
 TO PALM BEACH COUNTY BUILDING DEPARTMENT
 FOR IMPACT FEE ASSESSMENT. THEY SHALL BE
 STAMPED AT THAT OFFICE AND A COPY OF THE
 PAID RECEIPT SUBMITTED TO THE CITY OF
 WEST PALM BEACH DEPT OF CONSTRUCTION
 SERVICES BEFORE A PERMIT CAN BE ISSUED.
  
 3)WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 - ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-08-20 Cont ID  
Sent By rmcdouga Date 2007-08-20 Time 18:03 Rev Time 0.00
Received By rmcdouga Date 2007-08-16 Time 10:26 Sent To  
Notes
2007-08-16 10:57:552004 FBC
 ENCLOSE CARPORT TO FLORIDA ROOM
  
 DENIED BY BUILDING
  
 1) THE NOTICE OF COMMENCEMENT HAS EXPIRED AND WILL BE
 NEED TO BE RE-RECORDED BEFORE THE PERMIT IS ISSUED.
 THIS CAN BE DONE AFTER THE PLANS HAVE BEEN APPROVED BY
 ALL THE TRADES.
 THE WORK ON THE PROJECT IS REQUIRED TO START WITHIN 90
 DAYS OF THE DATE THE PERMIT IS ISSUED.
  
 2) BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY.THE PLANS MUST BE
 STAMPED AND THE RECEIPT ATTACHED TO THE APPLICATION.
 233-5025 IS THE CO. IMPACT FEE DEPARTMENT'S NUMBER.
  
 3) SHOW COMPLIANCE WITH FBC R 302.1 AND 302.2 FROM
 COMMENTS NUMBER 3 AND 4 OF THE PREVIOUS REVIEW. SPECIFY
 ON THE SITE PLAN ON SHEET 2 THAT THERE ARE NO
 STRUCTURES WITHIN 6' OF THE CARPORT ON THE ADJACENT LOT
 AT THE SIDE WITH THE 4' 7-1/2 " DISTANCE TO THE
 PROPERTY LINE OR SPECIFY ONE HOUR FIRE RATED WALLS WITH
 NO OPENINGS.
  
 4) SHOW COMPLIANCE WITH R403.1.4 WHICH REQUIRES ALL
 EXTERIOR FOOTINGS TO BE A MINIMUM OF 12 INCHES BELOW
 GRADE.
  
 5) SHOW COMPLIANCE WITH R404.1.6 WHICH REQUIRES THE
 CONCRETE FOUNDATION WALL TO EXTEND 6 INCHES ABOVE ABOVE
 THE ADJACENT FINISH GRADE.
  
 6) SHOW COMPLIANCE WITH FBC RESIDENTIAL SECTION 704,
 WHICH REQUIRES A MINIMUM 6 INCH INSPECTION SPACE
 BETWEEN THE FINISH GRADE AND THE EXTERIOR STUCCO
 VENEER. THE EXCEPTIONS ALLOW A 4 INCH INSPECTION SPACE
 ABOVE PATIO SLABS AND ENTRY AREAS.
  
 7) SPECIFY THE PROPOSED FINISH FLOOR ELEVATION AT THE
 ENCLOSED CARPORT AND THE EXISTING RESIDENCE. FBC*
 106.1.2
  
 8) IF VAPOR RETARDER REQUIRED BY R506.2.3 CAN NOT BE
 INSTALLED, THE SLAB WILL BE REQUIRED TO BE TREATED WITH
 A WATERPROOF SEALER.
  
 9) THE ENERGY CALCULATION FORM IS REQUIRED TO BE SIGNED
 BY THE OWNER/AGENT PER FBC CHAPTER 13.
  
 10) THE WALL SECTIONS ON SHEET 4 SPECIFIES R-30
 INSULATION BETWEEN THE 2 X 6 ROOF JOISTS. THE R-VALUE
 FOR 5-1/2" INSULATION IS R-19. PLEASE REVISE THE WALL
 SECTIONS AND THE ENERGY CALC. FORM FOR THE SINGLE
 ASSEMBLY FRAME CEILING.
  
 11)WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 - ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-01-31 Cont ID  
Sent By rmcdouga Date 2007-01-31 Time 14:16 Rev Time 0.00
Received By rmcdouga Date 2007-01-31 Time 14:16 Sent To  
Notes
2007-01-31 14:15:00DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY.THE PLANS MUST BE
 STAMPED AND THE RECEIPT ATTACHED TO THE APPLICATION.
 233-5025
  
 3) SHOW COMPLIANCE WITH R302.1 EXTERIOR WALLS. EXTERIOR
 WALLS SEPARATED BY LESS THAN 6 FEET (1828 MM) SHALL
 HAVE NOT LESS THAN A ONE-HOUR FIRE-RESISTIVE RATING
 WITH EXPOSURE FROM BOTH SIDES. PROJECTIONS SHALL NOT
 EXTEND TO A POINT CLOSER THAN 4 FEET (1220 MM) FROM AN
 ADJACENT PROJECTION OR WALL.
 EXCEPTION : DETACHED GARAGES ACCESSORY TO A DWELLING
 LOCATED WITHIN 2 FEET (610 MM) OF A LOT LINE SHALL BE
 PERMITTED TO HAVE ROOF EAVE PROJECTIONS NOT EXCEEDING 4
 INCHES (102 MM).
 PROJECTIONS EXTENDING INTO THE 6-FOOT (1829 MM)
 SEPARATION DISTANCE SHALL HAVE NOT LESS THAN 1-HOUR
 FIRE-RESISTIVE CONSTRUCTION ON THE UNDERSIDE. THE ABOVE
 PROVISIONS SHALL NOT APPLY TO WALLS WHICH ARE
 PERPENDICULAR TO A LINE EXTENDING FROM THE POINT FROM
 WHICH THE SEPARATION DISTANCE HAS BEEN MEASURED RUNNING
 AND PARALLEL TO THE PROPERTY LINE.
 EXCEPTION: TOOL AND STORAGE SHEDS, PLAYHOUSES AND
 SIMILAR STRUCTURES ARE NOT REQUIRED TO PROVIDE WALL
 PROTECTION BASED ON LOCATION ON THE LOT. THE ADDITION
 IS LESS THAN 6 FEET FROM THE PROPERTY LINE ON ONE SIDE.
 PROVIDE A SITE PLAN WHICH INDICATES THE DISTANCE TO
 STRUCTURE ON THE ADJACENT PROPERTY AT THIS LOCATION.
  
 4)R302.2 OPENINGS.
 OPENINGS SHALL NOT BE PERMITTED IN THE EXTERIOR WALL OF
 A DWELLING OR ACCESSORY BUILDING THAT IS SEPARATED FROM
 AN ADJACENT BUILDING BY A DISTANCE OF LESS THAN 6 FEET
 (1828 MM). THIS DISTANCE SHALL BE MEASURED
 PERPENDICULAR TO THE LINE USED TO DETERMINE THE
 SEPARATION DISTANCE.
  
 5)SHOW COMPLIANCE WITH R403.1.4 MINIMUM DEPTH. ALL
 EXTERIOR FOOTINGS SHALL BE PLACED AT LEAST 12 INCHES
 (305 MM) BELOW THE UNDISTURBED GROUND SURFACE.
  
 6)SHOW COMPLIANCE WITH R404.1.6 HEIGHT ABOVE FINISHED
 GRADE.
 CONCRETE AND MASONRY FOUNDATION WALLS SHALL EXTEND
 ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION AT
 ALL POINTS A MINIMUM OF 4 INCHES (102 MM) WHERE MASONRY
 VENEER IS USED AND A MINIMUM OF 6 INCHES (152 MM)
 ELSEWHERE.
  
 7) SHOW COMPLIANCE WITH SECTION 704 INSPECTION FOR
 TERMITES.
 IN ORDER TO PROVIDE FOR INSPECTION FOR TERMITE
 INFESTATION, CLEARANCE BETWEEN EXTERIOR WALL COVERINGS
 AND FINAL EARTH GRADE ON THE EXTERIOR OF A BUILDING
 SHALL NOT BE LESS THAN 6 INCHES (152 MM). EXCEPTIONS:
 1.PAINT OR DECORATIVE CEMENTITIOUS FINISH LESS
 THAN 5 / 8 INCH (17.1 MM) THICK ADHERED DIRECTLY TO THE
 MASONRY FOUNDATION SIDEWALL.
 2.ACCESS OR VEHICLE RAMPS WHICH RISE TO THE
 INTERIOR FINISH FLOOR ELEVATION FOR THE WIDTH OF SUCH
 RAMPS ONLY.
 3.A 4-INCH (102 MM) INSPECTION SPACE ABOVE PATIO
 AND GARAGE SLABS AND ENTRY AREAS.
 4.IF THE PATIO HAS BEEN SOIL TREATED FOR TERMITES,
 THE FINISH ELEVATION MAY MATCH THE BUILDING INTERIOR
 FINISH FLOOR ELEVATIONS ON MASONRY CONSTRUCTION ONLY.
 5.MASONRY VENEERS.
  
 8)INDICATE THE FINISH FLOOR ELEVATION OF THE EXISTING
 HABITABLE SPACE AND THE FINISH FLOOR OF THE ENCLOSED
 CARPORT. FBC* 106.1.2.
  
 9) SPECIFY THE CEILING HEIGHT IN THE ENCLOSED CARPORT.
 SEE 601.3 (4) FBC EXISTING BUILDING CODE AND R 305.
  
 10) SHOW COMPLIANCE WITH R506.2.3 VAPOR RETARDER. A 6
 MIL (0.006 INCH; 152 ?M) POLYETHYLENE OR APPROVED VAPOR
 RETARDER WITH JOINTS LAPPED NOT LESS THAN 6 INCHES (152
 MM) SHALL BE PLACED BETWEEN THE CONCRETE FLOOR SLAB AND
 THE BASE COURSE OR THE PREPARED SUBGRADE WHERE NO BASE
 COURSE EXISTS.
 EXCEPTION: THE VAPOR RETARDER MAY BE OMITTED:
 1.FROM GARAGES, UTILITY BUILDINGS AND OTHER
 UNHEATED ACCESSORY STRUCTURES.
 2.FROM DRIVEWAYS, WALKS, PATIOS AND OTHER FLATWORK
 NOT LIKELY TO BE ENCLOSED AND HEATED AT A LATER DATE.
 3.WHERE APPROVED BY THE BUILDING OFFICIAL, BASED
 ON LOCAL SITE CONDITIONS.
  
 11)SHOW COMPLIANCE WITH R806.1 VENTILATION REQUIRED.
  
 ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE
 CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF
 RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE
 SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE
 ENTRANCE OF RAIN. VENTILATING OPENINGS SHALL BE
 PROVIDED WITH CORROSION-RESISTANT WIRE MESH, WIT H 1 /
 8 INCH (3.2 MM) MINIMUM TO ? INCH (6.4 MM) MAXIMUM
 OPENINGS. CONTINOUS SOFFIT VENTS WILL BE NEEDED IN
 ORDER TO PROVIDE VENTILATION TO RAFTER SPACES.
  
 12)R703.6.1 EXTERIOR USE OF PORTLAND CEMENT PLASTER
 SHALL COMPLY WITH THE APPLICATION REQUIREMENTS OF ASTM
 C 926.ASTM C 926 REQUIRES STUCCO TO BE 7/8" THICK
 WHEN APPLIED VERTICALLY OVER A METAL PLASTER BASE.
  
 13) SPECIFY THE CONNECTORS FOR THE ROOF RAFTERS TO THE
 EXTERIOR FRAME WALLS AND BEAM. SEE R301.1 FOR CONTINOUS
 LOAD PATH.
  
 14)ON SHEET 1 THE BUILDING HEIGHT LESS THAN 60 FEET
 STATEMENT REFERS TO THE SBC. PLEASE CORRECT TO FBC.
  
 15) THE FOUNDATION PLAN ON SHEET 2 SPECIFIES SECTIONS
 A, B AND C ON 3. THESE SECTIONS ARE LOCATED ON SHEET 4.
 PLEASE CORRECT.
  
 16)THE DOOR NOTE ON THE FOUNDATION HAS AN ARROW
 POINTING TO WHAT APPEARS TO BE THE ANCHOR BOLT
 LOCATIONS. PLEASE CLARIFY.
  
 17) THE WHITE OUT ON SEVERAL OF THE SHEETS IS NOT
 ALLOWED ON SIGNED AND SEALED DRAWINGS. SEE FS 471.025.
  
 18)CHECK THE WIND PRESSURES FOR THE OPENING ON SHEET
 1. THE NEGATIVE AND POSITIVE DESIGN OPENING PRESSURES
 APPEAR TO BE REVERSED. THE NEGATIVE PRESSURES SHOULD BE
 HIGHER THAN THE POSITIVE ONES. THE NEGATIVE PRESSURE
 FOR THE WINDOW OPENINGS IN WALL ZONE 4 IS MORE THAN
 SPECIFIED. SEE TABLE R301.2(2).
  
 19) THE ENERGY CALCULATIONS THAT WERE SUBMITTED ARE ON
 THE WRONG FORMS.THE REQUIRED FORM IS 600C-04 R FOR
 SOUTH CLIMATE ZONES 7, 8 AND 9. THE FORMS ARE REQUIRED
 TO BE SIGNED BY THE PREPARER AND THE OWNER/AGENT.
  
 20)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE.
  
 21)WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 22)THE PRODUCT APPROVAL FOR THE EXTERIOR CONTAINS
 THREE DIFFERENT NOAS. SUBMIT TWO COPIES OF PRODUCT
 APPROVAL FOR THE DOOR THAT WILL BE INSTALLED.
  
 23) THE PRODUCT APPROVAL FOR THE TRACO SERIES 2100
 WINDOW IS MISSING THE FIRST PAGE OF THE DRAWINGS WHICH
 SPECIFIES THE DESIGN PRESSURES. THE STATE WEBSITE LISTS
 NOA # 05-0729.03 FOR THIS WINDOW. THE FL# IS 6585.
 SUBMIT COMPLETE PRODUCT APPROVALS.
  
 24) R301.2.1.2 INTERNAL PRESSURE.
 WINDOWS IN BUILDINGS LOCATED IN WIND-BORNE DEBRIS
 REGIONS SHALL HAVE GLAZED OPENINGS PROTECTED FROM
 WIND-BORNE DEBRIS OR THE BUILDING SHALL BE DESIGNED AS
 A PARTIALLY ENCLOSED BUILDING IN ACCORDANCE WITH THE
 FLORIDA BUILDING CODE, BUILDING . SUBMIT PRODUCT
 APPROVALS FOR THE STORM PANELS. SPECIFY THE OPENINGS
 THAT WILL BE SHUTTERED, THE FASTENER TYPE AND SPACING,
 THE CONNECTION TYPES, EDGE DISTANCE, ETC.
  
 25) PROVIDE THE FIRM LICENSE NUMBER OF THE
 ARCHITECTURAL/DESIGN FIRM LISTED IN THE TITLE BLOCK OF
 THE PLANS AS REQUIRED BY STATE STATUTES FS 471 AND
 481.
  
 26) ADDRESS COMMENT OF OTHER TRADES.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-09-26 Cont ID  
Sent By dpalmer Date 2007-09-26 Time 15:50 Rev Time 0.00
Received By dpalmer Date 2007-09-26 Time 15:40 Sent To B
Notes
2007-09-26 15:51:58** 2ND PROVISO **
  
 IF PLANS COME BACK FOR ANY COMMENTS FROM OTHER TRADES ,
 PLEASE CORRECT AT THIS TIME.
  
  
 ** CONDITION ISSUED FOR PERMIT ISSUANCE WHICH MUST BE
 DONE BEFORE FIRST ROUGH ELECTRICAL INSPECTION.
  
 1) NOTE: PLEASE SEE THE EXISTING DWELLING MUST MEET THE
 FBC R313 FOR THE EXISTING SLEEPING ROOMS INSIDE AND
 OUTSIDE TO BE BROUGHT UP TO CODE FOR SMOKE ALARM
 DEVICES.
 PLANS NEED TO SHOW IF THESE ARE NEW OR EXISTING MEETING
 THE CURRENT NFPA-72 11.5.1.1, 11.8.3
 PLEASE ALSO KNOW THAT THESE WILL ALSO BE REQUIRED TO
 MEET NEC 210.12 FOR ARC FAULT PROTECTION.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-08-13 Cont ID  
Sent By dpalmer Date 2007-08-13 Time 18:43 Rev Time 0.00
Received By dpalmer Date 2007-08-13 Time 18:22 Sent To B
Notes
2007-08-13 18:45:55NOTE ADDED:
 IF PLANS ARE RETURNED FOR ANY OTHER COMMENTS (BUILDING
 REVIEW) PLEASE ADDRESS AT THIS TIME.
2007-08-13 18:43:46** PROVISO **
  
 ** CONDITION ISSUED FOR PERMIT ISSUANCE WHICH MUST BE
 DONE BEFORE FIRST ROUGH ELECTRICAL INSPECTION.
  
 1) NOTE: PLEASE SEE THE EXISTING DWELLING MUST MEET THE
 FBC R313 FOR THE EXISTING SLEEPING ROOMS INSIDE AND
 OUTSIDE TO BE BROUGHT UP TO CODE FOR SMOKE ALARM
 DEVICES.
 PLANS NEED TO SHOW IF THESE ARE NEW OR EXISTING MEETING
 THE CURRENT NFPA-72 11.5.1.1, 11.8.3
 PLEASE ALSO KNOW THAT THESE WILL ALSO BE REQUIRED TO
 MEET NEC 210.12 FOR ARC FAULT PROTECTION.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-12-28 Cont ID  
Sent By mmiller Date 2007-08-07 Time 17:54 Rev Time 0.00
Received By dpalmer Date 2006-12-28 Time 11:53 Sent To M
Notes
2006-12-28 14:47:19** UNSET **
  
 1) NOTE: PLEASE CLARIFY IF THE ENGINEERED SIGNED ON
 PLANS IS PART OF WHAT APPEARS TO BE AN
 ARCHITECTURE/CONSTRUCTION FIRM OFFERING ARCHITECTURAL/
 ENGINEERING SERVICE. PLEASE SEE FLORIDA STATUTES
 471.023 AND 481.219 AND EITHER WOULD REQUIRE A FIRM
 LICENSE NUMBER WHICH IS ALSO KNOWN AS A CERTIFICATE OF
 AUTHORIZATION NUMBER.
  
 2) NOTE: PLEASE SEE THE PLANS ARE REQUIRED TO STATE THE
 CODE IN WHICH THE ELECTRICAL IS UNDER. PLEASE KNOW AS
 THIS PERMIT WAS APPLIED FOR AFTER DEC 7TH, THE NEW 2005
 NEC WAS ADOPTED BY THE STATE STARTING 12/8/06. PLEASE
 LIST THE CODE ON PLANS AS THE FBCIS SHOWN.
 PLEASE INDICATE THIS ON THE ELECTRICAL SHEETS.
 FBC 106.1.2, 106.3.5.4
  
 3) NOTE: PLEASE SEE THE NEW ROOM SHALL CONTAIN A METHOD
 OF CONTROLLING LIGHTING FOR INGRESS INTO THE NEW ROOM
 FROM THE OUTSIDE. PLEASE SEE THIS CAN BE DONE WITH A
 3-WAYOR OTHER OPTION.
 210.70 , LS 101 7.8
  
 4) NOTE: PLEASE SEE THERE ARE SEVERAL AREAS ON PLANS
 WHICH CONTAIN WHITE-OUT ON PLANS AND CONTAIN OTHER
 LOCATIONS WITH HAND DRAWN CHANGESEITHER OF WHICH ARE
 PERMITTED. PLEASE SEE FS 471.025
 PLEASE RE-PRINT PLANS WITH CHANGES ALREADY MADE
 ACCORDINGLY.
  
  
  
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
  
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-12-13 Cont ID  
Sent By adarroug Date 2007-12-13 Time 09:18 Rev Time 0.00
Received By adarroug Date 2007-12-13 Time 09:18 Sent To B
Notes
2007-12-13 09:18:33TO "RMCDOUGAL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-09-20 Cont ID  
Sent By adarroug Date 2007-09-20 Time 16:07 Rev Time 0.00
Received By adarroug Date 2007-09-20 Time 16:07 Sent To Z
Notes
2007-09-20 16:09:04TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-08-07 Cont ID  
Sent By mmiller Date 2007-08-07 Time 17:51 Rev Time 0.00
Received By mmiller Date 2007-08-07 Time 17:51 Sent To Z
Notes
2007-08-07 17:51:26SENT TO CHRIS HOOP'SDESK MMILLER

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-12-28 Cont ID  
Sent By adarroug Date 2006-12-28 Time 10:29 Rev Time 0.00
Received By adarroug Date 2006-12-28 Time 10:29 Sent To E
Notes
2006-12-28 10:30:34TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-01-31 Cont ID  
Sent By rmcdouga Date 2007-01-31 Time 14:16 Rev Time 0.00
Received By rmcdouga Date 2006-12-17 Time 15:34 Sent To  
Notes
2006-12-17 15:34:25TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-12-29 Cont ID  
Sent By tgordon Date 2006-12-29 Time 08:15 Rev Time 0.20
Received By tgordon Date 2006-12-29 Time 08:15 Sent To B
Notes
2006-12-29 08:16:36NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop Z ZONING
Rev No 3 Status P Date 2007-09-25 Cont ID  
Sent By choops Date 2007-09-25 Time 13:19 Rev Time 0.00
Received By choops Date 2007-09-25 Time 13:19 Sent To E
Notes
2007-09-25 13:20:59PROVISO:1) NONCONFORMING CARPORT WITH RESPECT TO THE
 MINIMUM SIDE SETBACK OF 5 FOOT, MAY BE ENCLOSED,
 HOWEVER, MAY NOT CREATE A NEW NONCONFORMITY OR INCREASE
 THE EXISTING NONCONFORMITY.MAY NOT BE LOCATED CLOSER
 THAN 4' 7 1/2" TO THE PROPERTY LINE.OVERHANGS SHALL
 NOT EXCEED THREE (3) FEET.2)ENCLOSED CARPORT MUST
 MAINTAIN INTERIOR ACCESS WITH EXISTING STRUCTURE.

Review Stop Z ZONING
Rev No 2 Status P Date 2007-08-09 Cont ID  
Sent By choops Date 2007-08-09 Time 15:32 Rev Time 0.00
Received By choops Date 2007-08-09 Time 15:32 Sent To E
Notes
2007-08-09 15:37:05PROVISO:NONCONFORMING CARPORT WITH RESPECT TO THE
 MINIMUM SIDE SETBACK OF 5 FOOT, MAY BE ENCLOSED,
 HOWEVER, MAY NOT CREATE A NEW NONCONFORMITY OR INCREASE
 THE EXISTING NONCONFORMITY.MAY NOT BE LOCATED CLOSER
 THAN 4' 7 1/2" TO THE PROPERTY LINE.OVERHANGS SHALL
 NOT EXCEED THREE (3) FEET.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-12-26 Cont ID  
Sent By mmclean Date 2006-12-26 Time 16:24 Rev Time 0.00
Received By mmclean Date 2006-12-26 Time 16:24 Sent To I
Notes
2006-12-26 16:34:15DENIED,
 1. THE EXISTING SURVEYS DOES NOT PROVIDE THE SIDE
 SETBACK OF THE EXISTING CARPORT.
 2. PLEASE PROVIDE THE SETBACK FOR THE EXISTING CARPORT
 ON TWOC COPIES OF SURVEYS..
 3. THE SITEPLANS SUBMITTED DOES NOT PROVIDE THE
 SETBACKS OF THE EXISTING CARPORT (SIDES).
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720