Plan Review Details - Permit 06120402
| Plan Review Stops For Permit 06120402 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2007-03-21 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2007-03-21 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2007-03-21 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2007-03-21 09:36:51 | SINCE A NEW STRUCTURE ( DUPLEX)IS BEING BUILT ON THE | | | SAME LOCATION OF THE DEMOLISHED BUILDING (USED TO BE | | | 601 14TH ST) A NEW SITE ADDRESS IS REQUIRED FOR THE NEW | | | STRUCTURE. | | | THE PREVIOUS SITE ADDRESS USED FOR THE DEMOLISHED | | | BUILDING CAN NOT BE USED FOR THE NEW STRUCTURE SINCE | | | THE MAIN ENTRANCE WAS DESIGNED ON HENRIETTA AVE . THIS | | | STRUCTURE WILL RECEIVE TWO SITE ADDRESSES ,ONE FOR EACH | | | UNIT ,SINCE THIS IS A DUPLEX. | | | THE REVISED SITE PLANS MUST REFLECT THE NEW SITE | | | ADDRESSES.THE NEW SITE ADDRESSES ISSUED ARE: 1503 | | | HENRIETTA AVE AND 1507 HENRIETTA AVE, WEST PALM BEACH , | | | FL 33401 | | | THE CITY WILL SEND AN OFFICIAL NOTIFICATON LETTER WITH | | | THE NEW SITE ADDRESSES ISSUED ,TO THE PROPERTY OWNER. | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-06-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-06-01 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-05-31 |
Time |
16:32 |
Sent To |
ENG |
|
| Notes |
| 2007-06-01 08:37:51 | ***NOTE: PLANS SENT TO ENGINEERING FOR REVIEW OF | | | SIDEWALK AND APPROACH. | | | | | | BUILDING REVIEW THIRD CHECKLIST: | | | 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | | FLORIDA STATUTE. | | | | | | 2- DRAINAGE PLAN SHOWS ARROWS LEADING THE WATER TO THE | | | NEIGHBOR'S PROPERTY. WATER CAN'T BE DIVERTED TO THE | | | NEIGHBOR'S PROPERTY. REVISE PLAN AS REQUIRED. | | | | | | 3- SHEET SP-1: | | | A) SIZE OF PARKING SPACESSHOWN ON SITE PLAN DON'T | | | MATCH SPECIFICATIONS ON PARKING NOTES AT BOTTOM OF | | | PAGE. REVISE AS REQUIRED TO MATCH. | | | | | | B) SITE PLAN AND SURVEY DON'T MATCH. REVISE AS | | | REQUIRED. SEE SURVEY. | | | | | | C) REVISE ADDRESS. CORRECT ADDRESS IS 1503 AND 1507 | | | HENRIETTA AVE. | | | | | | D) DRIVEWAY TURN OUTS DETAIL DOESN'T MATCH PLANS. | | | | | | E) CLARIFY WHY INSTALLING BACK FLOW PREVENTER AND | | | WHY ONLY ON ONE DWELLING?. | | | | | | F) LOCATION OF WATER METER IS WRONG. REVISE AS | | | REQUIRED. | | | | | | G) SETBACKS SHOWN ON SITE PLAN DON'T MATCH SETBACKS | | | SHOWN ON SURVEY. REVISE AS REQUIRED. | | | | | | H) SITE PLANAND SURVEY DON'T SHOW ALL CONCRETE | | | SLABS SHOWN ON FOUNDATION PLAN. PROVIDE ALL | | | INFORMATION. | | | | | | 4- REVISE ADDRESS IN ALL DRAWINGS. | | | | | | 5- PROVIDE TWO SURVEYS WITH CORRECT ADDRESS AND CORRECT | | | DIMENSIONS. SEE FLOOR PLANS.AND SHOWING ALL CONCRETE | | | SLABS.ONLY ONE SUBMITTED THIS TIME. | | | | | | 6- SHEET S-1: | | | A) DIMENSIONS ANDCOLUMN SPACINGDON'T MATCH.SEE | | | PLANS. REVISE AS REQUIRED. | | | | | | B) THERE ARE TWO F1 FOOTING DETAILS. ONE SHOULD BE | | | F1 AND THE OTHERF2. REVISE AS REQUIRED. | | | | | | C) FOUNDATION PLAN SHOWS CONCRETE SLAB EDGE TE AND | | | TE#2. THERE IS NOT FOOTING SCHEDULE SPECIFYING WHAT ARE | | | TE AND TE#2 SPECIFICATIONS. PROVIDE INFORMATION AS | | | REQUIRED. AND CLARIFY WHY IS REAR CONCRETE SLAB SHOWN | | | WITH DOTTED LINE. | | | | | | D) DIMENSIONS DON'T MATCH THOSE DIMENSIONS SHOWN ON | | | SURVEY. REVISE AS REQUIRED. ALSO, DIMENSIONS DON'T | | | MATCH DIMENSIONS SHOWN ON FIRST FLOOR PLAN. REVISE AS | | | REQUIRED. | | | | | | E) REVISE TYP. EXT. CONT. MONOLITHIC FOOTING DETAIL. | | | BOTTOM OF FOOTING NEEDS TO BE AT LEAST 12" BELOW GRADE. | | | SEC. R403.1.4 OF 2004 FLORIDA RESIDENTIAL CODE. | | | | | | F) ENGINEER TO PROVIDE CALCULATIONS SHOWING HOW | | | VERTICAL REINFORCEMENT SHOWN IN FOUNDATION PLAN IS | | | ADEQUATE TO PROVIDE THE REQUIRED WALL LATERAL | | | STABILITY.SEE PLANS FOR COLUMN SPACING. SEC. 106.1.2 | | | CITY AMENDMENTS TO FBC 2004. | | | | | | G) ENGINEER TO READ SOIL TEST REPORT AND REVISE | | | FOUNDATION NOTES AS REQUIRED. | | | | | | 7- SHEET A-1: | | | A) WINDOWS SPECIFIEDON PLAN DON'T MATCH. | | | COORDINATE SIZE OF WINDOWS WITH WINDOW SCHEDULE AND | | | WITH EXTERIOR ELEVATIONS.ALL WINDOWS ARE KEYED AS I, | | | BUT THEY ARE DIFFERENT SIZES.ALSO,INSTALLATION | | | SCHEDULE DOESN'T SHOW ANY I SYMBOL. THEY ARE SHOWN AS | | | WINDOW 1 OR 2.ALSO, WINDOWS NOT DRAWN TO SCALE. | | | COORDINATE AND REVISE AS REQUIRED. | | | | | | B) WINDOW ON KITCHEN AREA IS NOT AN EGRESS WINDOW. | | | REVISE AS REQUIRED. | | | | | | C) REVISE WINDOW AND DOOR BUCK DETAILS.BUCK NEEDS | | | TO PROVIDE FULLWINDOW/DOOR FRAME SUPPORT. SEE SEC. | | | R613.6.2 OF 2004 FLORIDA RESIDENTIAL CODE FOR PROPER | | | WAY OF INSTALLING BUCKS. | | | | | | D) WINDOW SILL DETAIL IS WRONG. REVISE AS REQUIRED. | | | | | | E) FLOOR PLAN DOESN'T SHOW REAR CONCRETE SLAB. | | | | | | 8- SHEET A-2: | | | A) DECORATIVE SHUTTERS NOTE SAYS THAT BAHAMA | | | SHUTTERS ON 14TH STREET ONLY, BUT ALL ELEVATIONS SHOW | | | BAHAMA SHUTTERS. REVISE AS REQUIRED. | | | | | | B) WINDOW SCHEDULE SHOWS WINDOW 1 WITH TRANSOM | | | ABOVE. THERE ARE NOT WINDOWS WITH TRANSOM ABOVE SHOWN | | | ON THE EXTERIOR ELEVATIONS. REVISE AS REQUIRED. | | | | | | C) OVERHANG AT FRONT OF BUILDING IS SHOWN AS 3'-0". | | | THIS INFORMATION DOESN'T MATCHROOF PLAN AND TRUSS | | | PLAN. REVISE AS REQUIRED. | | | | | | D) PROVIDE COMPLETE DETAILS FOR INSTALLATION OF ROOF | | | BRACKETS AT ENTRY AREA. SEC. 106.1.2 CITY AMENDMENTS TO | | | FBC 2004. | | | | | | 9- SHEET A-3: | | | A) NEW NOTE IN THE MIDDLE OF PAGE STATES THAT | | | BUILDING DESIGNED PER HVHZ.HVHZREQUIRES EXPOSURE | | | "C" IN ALL DESIGN.SEE SEC. 1620.3 FBC 2004.REVISE | | | INFORMATION ON TOP LEFT OF PAGE AND REVISE ALL LOAD | | | CALCULATIONS AS REQUIRED. | | | | | | B) INFORMATION ON TOP LEFT PAGE CALLS FOR 140 MPH, | | | WHILE TRUSS AND GIRDER NOTES CALLS FOR 146 MPH. REVISE | | | AS REQUIRED. | | | | | | C) WHAT IS THE ROOF +92.0 PSFSHOWN ON TOP LEFT | | | PAGE STANDS FOR?. SEC. 106.1.2 CITY AMENDMENTS TO FBC | | | 2004. | | | | | | D) TRUSS ANCHOR SCHEDULE: | | | * ANCHORS ARE NOT KEYED CORRECTLY IN THE ROOF FRAMING | | | PLAN. | | | | | | ** REVISE H-14 CONNECTOR. NEED TO SPECIFY WOOD TO | | | MASONRY CONNECTOR. | | | | | | *** SPECIFY SIZE OF META CONNECTOR. | | | | | | **** REVISE NUMBER OF FASTENERS AND LOADS FOR WHICH | | | CONNECTORS ARE DESIGNED FOR. SEE CURRENT SIMPSON | | | CATALOGUE AND REVISE AS REQUIRED. OTHERWISE, COMPLETE | | | ENGINEERING ANALYSIS WILL BE REQUIRED FOR FASTENERS AND | | | LOADS THAT DIFFER FROM THOSE TESTED AND PUBLISHED BY | | | THE MANUFACTURE. SEC. 106.1.2 CITY AMENDMENTS TO FBC | | | 2004. | | | | | | ***** SEE TRUSS PACKAGE AND REVISE SPECIFIED CONNECTORS | | | TO RESIST THE CALCULATED LOADS. SEC. 106.1.2 CITY | | | AMENDMENTS TO FBC 2004. | | | | | | E) ROOF PLAN SHOWS TRUSSESRUNNING FRONT TO BACK BY | | | TENANT SEPARATION WALL. SEE TRUSS PLAN FOR CORRECT | | | TRUSS LAYOUT AND REVISE AS REQUIRED.AND SPECIFY ALL | | | TRUSS CONNECTORS AT BOTH ENDS. | | | | | | F) PROVIDE COMPLETE DETAILS AND SPECS FOR WOOD | | | LEDGER TO RECEIVE ROOF TRUSSES. SEE TRUSS PLAN. SEC. | | | 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | G) PROVIDE COMPLETE SPECIFICATIONS FOR CONTINUITY OF | | | TENANT SEPARATION WALL.SPECIFY TIE BEAM AND RAKE | | | BEAM. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | H) PNEUMATIC FASTENING SCHEDULE: | | | * PROVIDE ONLY THE INFORMATION THAT PERTAINS TO THIS | | | PROJECT TO AVOID CONFLICTS. | | | | | | ** COORDINATE INFORMTIONTO MATCH WITH PLANS AND | | | DETAILS. EG: CHECK ROOF SHEATHING SIZE AND BUCK DETAILS | | | AND REVISE AS REQUIRED. | | | | | | 10- PRIOR TO SUBMITTAL TO THIS OFFICE, BRING PLANS TO | | | THE FIFTH FLOOR FOR HISTORICAL APPROVAL AFTER | | | CORRECTIONS ARE DONE TO THE ORIGINAL PLANS. | | | | | | 11- SHEET A-4: | | | A) TENANT SEPARATION WALL DETAIL: | | | * PROVIDE COMPLETE INFORMATION FOR TOP PORTION OF THE | | | WALL. | | | | | | ** CLARIFY WHY SOFFIT ELEVATION VARIES? | | | | | | *** REVISE NOTE REGARDING APPROVED HURRICANE STRAPS. | | | THIS IS NOT A WOOD FRAMED WALL. | | | | | | **** CONCRETE SLAB INFORMATION DOESN'T MATCH FOUNDATION | | | PLAN. REVISE AS REQUIRED. | | | | | | ***** DETAIL FOR VERTICAL REINFORCEMENT IS DRAWN | | | INCORRRECTLY.PROVIDE COMPLETE SPECIFICATIONS FOR | | | VERTICAL REINFORCEMENT INCLUDING SPLICING ETC.SEC. | | | 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | ****** HOW ARE THE TRUSSES RESTING ON THIS WALL? | | | | | | B) WHERE DOES THE STRAP AND TIE DOWN DETAIL APPLIES | | | TO?SEC. 106.1.2CITY AMENDMENTS TO FBC 2004. | | | | | | C) TYPICAL WALL SECTION: | | | * TRUSS CONNECTOR INFORMATION TO MATCH TRUSS ANCHOR | | | SCHEDULE. | | | | | | ** SPECIFY MIN. FOOTING DEPTH AS REQUIRED BY SEC. | | | R403.1.4 OF 2004 FLORIDA RESIDENTIAL CODE. | | | | | | 12- ENERGY CALCULATIONS: | | | A) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | | INCLUDING CORRECT ADDRESS AND BUILDER. | | | | | | B) PROVIDE REVISED FORM 600A-2004 R. | | | | | | C) IF CALCULATIONS ARE NOT DONE FOR WORST CASE | | | SCENARIO, THEN THEY SHALL BE DONE WITH ACTUAL BUILDING | | | ORIENTATION. SEE SURVEY FOR CORRECT ORIENTATION. | | | | | | D) ENGINEER TO PROVIDE HIS NAME AND LICENSE NUMBER | | | AS REQUIRED BY CHAPTER 471 OF FLORIDA STATUTE. | | | | | | E) OVERHANG HEIGHT AND OVERHANG LENGTH ARE | | | INCORRECT. THEY CAN'T BE ZERO. REVISE AS REQUIRED. | | | | | | 13- ENERGY CALCULATIONS ARE TAKING THE CEILING FAN | | | CREDIT. THEREFORE NEED TO SPECIFY IN DRAWINGS CEILING | | | FAN SIZE IN ALL ROOMS AS REQUIRED BY TABLE 13-607.1.A.1 | | | FBC 2004. | | | | | | 14- PROVIDE PRODUCT APPROVAL AS REQUIRED BY RULE 9B-72 | | | FOR: | | | A) ROOF SHINGLES. | | | | | | B) PRECAST LINTELS. | | | | | | C) ALL TRUSS CONNECTORS SPECIFIED ON PLANS. | | | | | | 15- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING)ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | ***NOTE: SOME PRODUCT APPROVALS HAVE THE REVIEW STAMP | | | FROM AMD GROUP. WHO IS THIS?THE ENGINEER OF RECORD IS | | | DM & L ENGINEERING. | | | | | | 16- PROVIDE 2 SURVEYS WITH CORRECT ADDRESS. | | | | | | 17- ENGINEER WAS CHARGED 4 TIMES FEE FOR PLAN REVIEW | | | FOR MULTIPLE DENIED CHECKLIST AS REQUIRED BY FLORIDA | | | STATUTE 553.80(2)(B).SEE ATTACHED COPY.ENGINEER | | | OWES $3362.34. | | | | | | 18- TRUSS PACKAGE: | | | A) TRUSSES NEED TO BE DESIGNED USING ASCE 7-02NOT | | | ASCE 7-05.REVISE AS REQUIRED. | | | | | | B) ENGINEER TO DATE DRAWINGS WHEN SEAL IS IMPRESSED | | | AS REQUIRED BY CHAPTER 471 FLORIDA STATUTE. | | | | | | C) GENERAL DETAILS ARE TOO DARK AND ARE NOT | | | LEGIBLE. | | | | | | D) WHO'S ADM GROUP?.THIS IS NOT THE ENGINEER OF | | | RECORD. | | | | | | D) REVISED TRUSS PACKAGE TO BE SUBMITTED TO BUILDING | | | INSPECTOR AT TIME OF FRAMING INSPECTION. | | | | | | 19- SOIL TEST REPORT: | | | A) MISSING KEY PLAN SHOWING LOCATION OF BORINGS. | | | | | | B) ENGINEER TO PROVIDE THE COMPANY CERTIFICATE OF | | | AUTHORIZATION NUMBER IN THE LETTERHEAD AS REQUIRED BY | | | SEC. 61G15-23.002 OF FLORIDA ADMINISTRATIVE CODE. | | | | | | ***NOTE: | | | * PLEASE DON'T ATTACHPRODUCT APPROVALS TO PLANS. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-03-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-03-19 |
Time |
19:02 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-03-19 |
Time |
12:38 |
Sent To |
PC |
|
| Notes |
| 2007-03-19 19:03:03 | BUILDING REVIEW SECOND CHECKLIST: | | | 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT AS REQUIRED | | | BY SEC. 713.13 FLORIDA STATUTES. | | | | | | 2- PROVIDE DRAINAGE PLANS AS REQUIRED BY SEC. R401.3 | | | 2004 FLORIDA RESIDENTIAL CODE. | | | | | | 3- ENGINEER TO PROVIDE ALL HIS INFORMATION IN THE TITLE | | | BLOCK AS REQUIRED BY CHAPTER 471 FLORIDA STATUTES AND | | | FLORIDA ADMINISTRATIVE CODE SEC. 61G15-23.002. | | | INCLUDING ENGINEERING FIRM'S CERTIFICATE OF | | | AUTHORIZATION NUMBER. | | | ***NOTE: ENGINEER'S NAME DOESN'T MATCH ENGINEER'S NAME | | | SHOWN ON EMBOSSED SEAL. | | | | | | 4- SHEET SP-1: | | | A) REVISE ALL DRIVEWAY AND APPROACH NOTES. CONTACT | | | CITY OF WEST PALM BEACH ENGINEERING DEPARTMENT AT | | | (561)494-1040 FOR CITY STANDARDS. | | | | | | B) REVISE SIZE OF PARKING SPACES.NUMBER AND SIZE | | | OF PARKING SPACES DON'T MATCHNOTES AT BOTTOM OF | | | SHEET. THERE IS NOT ENOUGH ROOM TO BACK UP.CHECK | | | SPECIFIED SIZES: 14'-0" X 18'-0"?. SEE ZONING | | | COMMENTS. | | | | | | C) SHOW ALL BUILDING SETBACKS TO VERIFY COMPLIANCE | | | WITH SEC. R302 2004 FLORIDA RESIDENTIAL CODE AND TABLE | | | 704.8 2004 FBC. | | | | | | D) CLEARLY IDENTIFY PROPERTY LINES.SEC. 106.1.2 | | | CITY AMENDMENTS TO FBC 2004. | | | | | | 5- PROVIDE SOIL TEST REPORT (2 COPIES). | | | | | | 6- SHEET S-1: | | | A) COLUMN SCHEDULE AND TYPICAL NOTES IN FOUNDATION | | | PLANS DON'T MATCH.REVISE AS REQUIRED. | | | | | | B) 4" DROP IS SHOWN ON MASTER BEDROOM WINDOW INSTEAD | | | OF BEING SHOWN FOR ENTRY DOOR. REVISE AS REQUIRED. | | | | | | C) FOUNDATION NOTES AND SPECIFICATIONS SHOWN ON | | | FOUNDATION PLAN FOR WIRE MESH SIZE DON'T MATCH. REVISE | | | AS REQUIRED. | | | | | | D) DETAIL F2 DOESN'T APPLY TO THIS PROJECT.THIS IS | | | NOT WOOD FRAMING. SEE TYPE OF INTERIOR BEARING WALL. | | | | | | E) FOOTING SCHEDULE SHOWS FOOTING F2 WITH 3 #5 BARS | | | AT THE BOTTOM, WHILE DETAIL F2 SHOWS 2 #5 AT BOTTOM AND | | | 1 #5 AT TOP. REVISE AS REQUIRED. | | | | | | F) CLARIFY FOOTING SIZE F2. FOOTING SCHEDULE CALLS | | | FOR 24"X12", WHILE INTERIOR BEARING WALL SECTION ON | | | SHEET A-4 CALLS FOR 12" X 24".WHICH DIMENSION IS THE | | | WIDTH AND WHICH IS THE DEPTH OF THE FOOTING. SEC. | | | 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | G) PROVIDE ONLY THE DETAILS THAT APPLY TO THIS | | | PROJECT TO AVOID CONFUSIONS/CONFLICTS AND EXPEDITE | | | REVIEW PROCESS. | | | | | | H) DETAIL F1: SPECIFY FOOTING EMBEDMENT BELOW GRADE | | | TO VERIFY COMPLIANCE WITH SEC. R403.1.4 2004 FLORIDA | | | RESIDENTIAL CODE. | | | | | | I) WINDOW DETAIL: | | | * WHY SHOWING SHUTTERS DETAILS IF WINDOW NOTES ON | | | SHEET A-1 CALLS FOR IMPACT GLASS?. | | | ** WHY SHUTTER DETAIL SHOWS ATTACHMENT OF SHUTTER | | | TRACK TO CONCRETE SLAB IF THIS IS A WINDOW DETAIL? *** | | | REVISE BUCK DETAIL. SEE SEC. R613.6.2 2004 FLORIDA | | | RESIDENTIAL CODE FOR PROPER WAY OF ATTACHING BUCKS. | | | | | | J) ENGINEER TO PROVIDE CALCULATIONS SHOWING HOW | | | VERTICAL REINFORCING SHOWN IN FOUNDATION PLAN WILL | | | PROVIDETHE REQUIRED LATERAL SUPPORT OF THIS BUILDING. | | | SEE PLANS FOR VERTICAL REINFORCEMENT SPACING. SEC. | | | 106.1.2 CITY AMENDMENTS TO FBC 2004 AND SEC. 1609 FBC | | | 2004. | | | | | | K) DIMENSIONS SHOWN ON FOUNDATION PLANAND | | | LOCATIONS OF COLUMNS DON'T MATCH REVISE AS REQUIRED. | | | | | | 7- SHEET A-1: | | | A) PROVIDEDIMENSIONSFOR ENTRY PORCH TO DETERMINE | | | TOTAL PORCH AREA.BUILDING PERMIT VALUATION WILL BE | | | ESTIMATED AFTER SQUARE FOOTAGE ISCLARIFIED. | | | | | | B) PROVIDE COMPLETE STRUCTURAL BUCK DETAIL. SPECIFY | | | ALL BUCK FASTENERS AND SEESEC. R613.6.2 2004 FLORIDA | | | RESIDENTIAL CODE FOR PROPER BUCK INSTALLATION. BUCK | | | NEEDS TO PROVIDE FULL SUPPORT TO THE WINDOW/DOOR. | | | | | | C) SOME ROOMS DON'T HAVE COMPLETE SPECS FOR SIZE OF | | | AND TYPE OF WINDOWS.PROVIDE COMPLETE INFORMATION. | | | ALSO, SIZE OF WINDOWS ARE NOT DONE TO SCALE AND DON'T | | | MATCH EXTERIOR ELEVATIONS EITHER.REVISE AS REQUIRED. | | | | | | 8- SHEET A-2: | | | A) CLARIFY NOTE REGARDING BAHAMA SHUTTERS ON 14TH | | | STREET ONLY. ALL ELEVATIONS SHOW COLONIAL SHUTTERS. | | | INFORMATION IS MISLEADING. | | | | | | C) ELEVATIONS DON'T MATCH FLOOR PLAN.SEE REVISED | | | FLOOR PLAN FOR SIZE OF WINDOWS. REVISE AS REQUIRED. | | | | | | D) PROVIDE COMPLETE STRUCTURAL INFORMATION FOR | | | OVERHANG ABOVE ENTRY AREA. PROVIDE COMPLETE STRUCTURAL | | | SECTION/DETAIL WITH COMPLETE SPECIFICATIONS, | | | DIMENSIONS, HEIGHT, ETC.SEC. 106.1.2 CITY AMENDMENTS | | | TO FBC 2004. | | | | | | E) WINDOW SCHEDULE DOESN'T MATCH FLOOR PLAN. REVISE | | | AS REQUIRED. | | | | | | 9- SHEET A-3: | | | A) PROVIDE ONLY THE INFORMATION THAT IS RELEVANT TO | | | THIS PROJECT. THERE ARE A LOT OF NOTES AND TABLES THAT | | | DON'T APPLY TO THIS PROJECT. | | | | | | B) PIGGY BACK TRUSS DETAIL: | | | * IS THIS THE DETAIL FOR ENTRY PORCH? | | | ** WHERE ARE THE RIGHT HAND SIDE TRUSSES SUPPORTED | | | ON?. THERE IS NOT BEAM TO SUPPORT THEM.DETAIL IS | | | INCOMPLETE AND WRONG. PROVIDE COMPLETE SECTION DETAIL. | | | SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | C) TRUSS CONNECTOR SCHEDULE AND CONNECTORS SPECIFIED | | | ON ROOF FRAMING PLAN DON'T MATCH. REVISE AS REQUIRED. | | | | | | D) REVISE NUMBER AND TYPE OF FASTENERS SPECIFIED ON | | | TRUSS CONNECTOR SCHEDULE. SEE CURRENT CATALOG FOR | | | UPDATED INFORMATION. OTHERWISE, ENGINEER TO PROVIDE | | | COMPLETE ENGINEERING ANALYSIS SHOWING WHY CONNECTORS | | | ARE DIFFERENT THAN THOSE TESTED AND PUBLISHED BY THE | | | MANUFACTURER. SEC. 106.1.2 CITY AMENDMENTS TO FBC | | | 2004. | | | | | | E) MANUFACTURER FOR CONNECTORS SPECIFIED ON ROOF | | | FRAMING PLAN IS OUT OF BUSINESS. REVISE AS REQUIRED. | | | | | | F) CLEARLY IDENTIFY TRUSSES FOR WHICH UPLIFT | | | PRESSURES WERE CALCULATED. | | | | | | G) ENGINEER TO COORDINATE ALL NOTES AND CHARTS SHOWN | | | ON THIS DRAWINGS. THERE IS A LOT OF MIXED INFORMATION | | | THAT NEEDS TO BE COORDINATED.SEE 2004 FLORIDA | | | RESIDENTIAL CODE AND ALLINFORMATION SUBMITTED IN THIS | | | SHEET.PROVIDE ONLY THE REQUIRED INFORMATION.SEE | | | SECTIONS . R301 2004 FLORIDA RESIDENTIAL CODE. ALSO, | | | SEE SEC. R803.2.3.1 OF 2004 FLORIDA RESIDENTIAL CODE | | | FOR MINIMUM REQUIREMENTS FOR ROOF SHEATHING. REVISE AND | | | COORDINATE ALL INFORMATION IN SHEET A-3 TO MATCH. | | | | | | H) PNEUMATIC FASTENING SCHEDULE: PROVIDE ONLY THE | | | INFORMATION THAT APPLIES TO THIS PROJECT.CHECK/REVISE | | | SPACING FOR BUCK DETAILS FASTENING. INFORMATION DOESN'T | | | MATCH. ALSO, COORDINATE WITH PROVIDED BUCK DETAIL. | | | | | | I) ROOF FRAMING PLAN CALLS DWELLING SEPARATION WALL | | | A "FIRE WALL".SEEFBC 2004 FOR CORRECT DEFINITION | | | FOR "FIRE WALL" AND REVISE AS REQUIRED. | | | | | | J) PROVIDE COMPLETE SECTION THRU DWELLING SEPARATION | | | WALL TO SHOW COMPLIANCE WITH SEC. R317.1 2004 FLORIDA | | | RESIDENTIAL CODE. | | | | | | K) REVISE ATTIC VENTILATION CALCULATIONS AND NOTES | | | SEE SEC. R806 2004 FLORIDA RESIDENTIAL CODE FOR PROPER | | | INFORMATION. | | | | | | L) ROOF FRAMING PLAN DOESN'T MATCH EXTERIOR | | | ELEVATIONS. SEE ENTRY PORCH. REVISE AS REQUIRED. | | | | | | | | | 10- PRIOR TO SUBMITTAL TO THIS OFFICE BRING PLANS FOR | | | HISTORICAL APPROVAL AFTER CORRECTIONS ARE DONE TO THE | | | PLANS. | | | | | | 11- SHEET A-4: | | | A) REVISE INTERIOR BEARING WALL TO MATCH FLOOR PLAN. | | | REVISE SIZE OF FOOTING, WALL CONSTRUCTION, ETC. | | | * WHAT'S THE BEAM SHOWN ON TOP OF WALL? | | | ** HOW ARE TRUSSES RESTING ON THIS WALL. SEE ROOF | | | FRAMING PLAN. | | | *** WHAT'STHE HOOK SHOWN AT THE BOTTOM OF WALL | | | CONNECTING TO FOOTING. PROVIDECOMPLETE SPECS. SEC. | | | 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | B) SPECIFY FIREBLOCKING ON INTERIOR BEARING WALL | | | SECTION AS REQUIRED BY SEC. R602.8 2004 FLORIDA | | | RESIDENTIAL CODE. | | | | | | C PROVIDE DETAIL/SPECS FOR DWELLING SEPARATION AT | | | ATTIC AREA. SEC. R317.1 2004 FLORIDA RESIDENTIAL CODE. | | | | | | D) PROVIDE ALL DESIGN CRITERIA, INCLUDING ALL WIND | | | LOADS, AND LIVE AND DEAD LOADS. REFERENCE 2004 FLORIDA | | | RESIDENTIAL CODE,WHICH IS THE CODE THAT REGULATES | | | THIS BUILDING, NOT SECTIONS 1606 OF FBC 2004. SEE SEC. | | | R301 AND TABLE R301.5 OF 2004 FLORIDA RESIDENTIAL CODE. | | | REVISE AS REQUIRED. INCLUDE ALL ATTIC LIVE LOADS. | | | | | | E) PLYWOOD NAILING NOTES TO MATCH INFORMATION ON | | | SHEET A-3 AFTER APPROPRIATE REVISIONS ARE DONE. | | | | | | F) TYPICAL WALL SECTION: | | | *WHAT IS 2"X4" STRIP?. IS IT FIREBLOCKING?. ALSO, | | | VERIFY SIZE WITH SIZE OF FURRING STRIPS FOR DRYWALL | | | INSTALLATION. | | | **WHAT IS 325# SHINGLES? | | | *** ROOF SHEATHING SIZE AND TYPE TO MATCH | | | INFORMATION ON SHEET A-3 AFTER APPROPRIATE REVISIONS | | | ARE DONE. | | | **** TRUSS CONNECTOR TO MATCH INFORMATION ON SHEET | | | A-3 AFTER APPROPRIATE REVISIONS ARE DONE. | | | ***** SPECIFY FOOTING MIN. DEPTH AS REQUIRED BY SEC. | | | R 403.1.4 2004 FLORIDA RESIDENTIAL CODE. | | | ****** SPECIFY MINIMUM FINISH FLOOR AS REQUIRED BY | | | SEC. R404.1.6 2004 FLORIDA RESIDENTIALCODE. | | | | | | G) TRUSS/ WOOD CONNECTOR SCHEDULE DOESN'T APPLY TO | | | THIS PROJECT AND IS USING CONNECTORS THAT NO LONGER | | | EXIST. COMPANY IS OUT OF BUSINESS. | | | ALSO, ROOFTILE INFORMATION DOESN'T APPLY. | | | | | | | | | 12- ENERGY CALCULATIONS: | | | A) PROVIDE COMPLETE INFORMATION ON TOP OF FORM. | | | | | | B) THIS IS NOT A SINGLE FAMILY DETACHED BUILDING. | | | SEE CHAPTER 13 2004 FBC FOR PROPER TYPE OF BUILDING. | | | AND, NEED ENERGY CALCULATIONS FOR EACH DWELLING.SEE | | | DEFINITIONS ON SUBCHAPTER13-2 OF 2004 FBC. REVISE AS | | | REQUIRED.SEE SEC. 15-101.2.5.1 FBC 2004. | | | | | | C) IF CALCULATIONS ARE NOT DONE FOR WORST CASE | | | SCENARIO, THEN THEY SHALL BE DONE ON ACTUAL BUILDING | | | ORIENTATION.ENERGY CALCULATIONS SUBMITTED ARE NOT FOR | | | WORST CASE SCENARIO AND BUILDING ORIENTATION DON'T | | | MATCH ACTUAL BUILDING ORIENTATION. SEE SURVEY AND | | | REVISE AS REQUIRED. | | | | | | D) OVERHANG LENGTH AND HEIGHT ARE INCORRECT.THEY | | | CAN'T BE ZERO. REVISE AS REQUIRED. | | | | | | 13- ENERGY CALCULATIONS ARE TAKINGTHE CEILING FAN | | | CREDIT. THEREFORE NEED TO SPECIFY CEILING FAN SIZE IN | | | ALL ROOMS AS REQUIRED BY TABLE 13-607.1.A.1 FBC 2004. | | | | | | 14- PROVIDE PRODUCT APPROVAL AS REQUIRED BY RULE 9B-72 | | | FOR: | | | A) SINGLE HUNG WINDOWS.TWO DIFFERENT PRODUCT | | | APPROVALS WERE SUBMITTED. ONLY THE ONE FOR LARGE | | | MISSILE IMPACT CAN BE USED FOR OPENINGS BELOW 30'-0" | | | HIGH. PROVIDE 2 COPIES. | | | | | | B) SHINGLES. | | | | | | C) BAHAMA SHUTTERS AND COLONIAL SHUTTERS SHOWN ON | | | EXTERIOR ELEVATIONS. AND PROVIDE COMPLETE INSTALLATION | | | SCHEDULE. SEE ATTACHED INSTALLATION SCHEDULE SAMPLE. | | | PROVIDE ALL REQUIRED INFORMATION. | | | | | | D) PRECAST LINTELS. | | | | | | E) ENTRY DOORS. | | | | | | F) REAR DOORS. | | | | | | G) ALL STRUCTURAL SIMPSON OR USP CONNECTORS | | | SPECIFIED ON PLANS ANDDETAILS. | | | | | | | | | 15- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | | | | 16- DUPLEX REQUIRES TWO SEPARATE ADDRESSESAND PLANS | | | NEED TO BE REVISED SHOWING CORRECT ADDRESS.PLEASE | | | CONTACT LILLY URSU AT (561)822-1239 TO GET CORRECT | | | ADDRESS. | | | | | | 17- PROVIDE SURVEYS (TWO) SHOWING REVISED PARKING | | | SPACES.NOTE: ORIGINAL SEAL AND SIGNATURE. | | | | | | 18- ENGINEER TO SEE ATTACHED COPY OF FLORIDA STATUTE | | | REGARDING REVIEW OF DESIGN PROFESSIONAL DOCUMENTS. | | | | | | | | | ***NOTE: | | | ONE COPY OF PLANS WILL BE SEND TO THE BOARD OF | | | ENGINEERS FOR THEIR REVIEW. | | | | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-01-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-01-29 |
Time |
18:25 |
Rev Time |
5.00 |
| Received By |
jgomez |
Date |
2007-01-29 |
Time |
17:54 |
Sent To |
|
|
| Notes |
| 2007-01-29 18:59:15 | BUILDING REVIEW CHECKLIST: | | | 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT AS REQUIRED | | | BY SEC. 713.13 FLORIDA STATUTES. | | | | | | 2- PAY IMPACT FEES TO PALM BEACH COUNTY. BRING BACK | | | STAMPED DRAWINGS AND COPY OF PAID RECEIPT. | | | | | | 3- PROVIDE TRUSS DRAWINGS FOR REVIEW PRIOR TO | | | INSTALLATION. SEE SEC. R802.10 2004 FLORIDA RESIDENTIAL | | | CODE FOR ALL REQUIRED INFORMATION ON TRUSS DRAWINGS. | | | ALSO, DESIGNER OF RECORD TO REVIEW AND APPROVE THEM | | | PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | | | 4- PROVIDE DRAINAGE PLANS AS REQUIRED BY SEC. R401.3 | | | 2004 FLORIDA RESIDENTIAL CODE. | | | | | | 5- ENGINEER TO PROVIDE ALL HIS INFORMATION IN THE TITLE | | | BLOCK AS REQUIRED BY CHAPTER 471 FLORIDA STATUTES AND | | | FLORIDA ADMINISTRATIVE CODE SEC. 61G15-23.002. | | | INCLUDING ENGINEERING FIRM'S CERTIFICATE OF | | | AUTHORIZATION NUMBER. | | | | | | | | | 6- SHEET SP-1:A) REVISE ALL DRIVEWAY AND APPROACH | | | NOTES. CONTACT CITY OF WEST PALM BEACH ENGINEERING | | | DEPARTMENT AT (561)494-1040 FOR CITY STANDARDS. | | | | | | B) DRAINAGE CAP CALCS HAVE NOTHING TO DO WITH | | | PROJECT. | | | | | | C) REVISE SIZE OF PARKING SPACES. | | | | | | D) PAVEMENT DETAILS DON'T APPLY TO THIS JOB. | | | | | | E) FLOOR PLAN IS CALLED EXISTING SITE PLAN. THIS IS | | | THE PROPOSED SITE PLAN. REVISE AS REQUIRED. | | | | | | F) CLARIFY WHY BACKFLOW PREVENTER IS SHOWN FOR ONE | | | UNIT ONLY? | | | | | | 7- PROVIDE SOIL TEST REPORT (2 COPIES). | | | | | | 8- SHEET S-1:A) FOOTING SCHEDULE AND FOOTING TYPICAL | | | NOTES SHOWN ON FOUNDATION PLAN DON'T MATCH.REVISE AS | | | REQUIRED. | | | | | | B) COLUMN SCHEDULE AND TYPICAL NOTES IN FOUNDATION | | | PLANS DON'T MATCH EITHER. REVISE AS REQUIRED. | | | | | | C) ENGINEER TO SPECIFY CONCRETE SLABS JOINTS AS | | | REQUIRED BY SEC. R506.2.4 2004 FLORIDA RESIDENTIAL | | | CODE. | | | | | | D) 4" DROP IS SHOWN ON MASTER BEDROOM WINDOW INSTEAD | | | OF BEING SHOWN FOR ENTRY DOOR. REVISE AS REQUIRED. | | | | | | E) CORRECT WORDING IN CONCRETE SLAB SPECS IS 6 MIL | | | VISQUEEN (NOT JISQUEEN) REVISE AS REQUIRED. | | | | | | F) DETAIL F1 CALLS FOR WELDED WIRE MESH SPECS ON | | | FOUNDATION NOTES. WHERE ARE THE FOUNDATION NOTES? | | | | | | G) DETAIL F2 DOESN'T APPLY TO THIS PROJECT.THIS IS | | | NOT WOOD FRAMING. SEE TYPE OF INTERIOR BEARING WALL. | | | AND,SPECIFY SIZE OF FOOTING ACCORDINGTO TYPE OF | | | WALL TO BE SUPPORTED. SEC. 106.1.2CITY AMENDMENTS TO | | | FBC 2004. | | | | | | H) DETAIL F2 SHOWS 3 RE-BARS, WHILE FOOTING SCHEDULE | | | CALLS FOR 2 RE-BARS. REVISE AS REQUIRED. | | | | | | I) PROVIDE ONLY THE DETAILS THAT APPLY TO THIS | | | PROJECT TO AVOID CONFUSIONS/CONFLICTS AND EXPEDITE | | | REVIEW PROCESS. | | | | | | 9- SHEET A-1:A) PROVIDE CALCULATIONS AND DIMENSIONS | | | SHOWING HOW102SF OF COVERED ENTRY WAS ACHIEVED? PLANS | | | DON'T PROVIDE ENOUGH INFORMATION TO VERIFY SQUARE | | | FOOTAGE.BUILDING PERMIT VALUATION WILL BE ESTIMATED | | | AFTER SQUARE FOOTAGES ARE CLARIFIED. | | | | | | B) SPECIFY ATTIC ACCESS SIZE. SEC. R807 2004 FLORIDA | | | RESIDENTIAL CODE. | | | | | | C) DRAWINGS ARE INCOMPLETE: MISSING SIZE OF ENTRY | | | DOORS,CLOSET DOORS, ETC. | | | | | | D) PROVIDE COMPLETE STRUCTURAL BUCK DETAIL. SPECIFY | | | ALL BUCK FASTENERS AND SEESEC. R613.6.2 2004 FLORIDA | | | RESIDENTIAL CODE FOR PROPER BUCK INSTALLATION. BUCK | | | NEEDS TO PROVIDE FULL SUPPORT TO THE WINDOW/DOOR. | | | | | | 10- SHEET A-2:A) SPECIFY CALCULATED DESIGN PRESSURES | | | FOR ENTRY DOORS. SEC. R301 2004 FLORIDA RESIDENTIAL | | | CODE. | | | | | | B) CLARIFY NOTE REGARDING BAHAMA SHUTTERS ON 14TH | | | STREET ONLY. ALL ELEVATIONS SHOW COLONIAL SHUTTERS. | | | | | | C) ELEVATIONS DON'T MATCH FLOOR PLAN.SOME ROOMS | | | HAVE DOUBLE WINDOWS MULLED TOGETHER. REVISE AS | | | REQUIRED. | | | | | | D) PROVIDE COMPLETE STRUCTURAL INFORMATION FOR | | | OVERHANG ABOVE ENTRY AREA. PROVIDE COMPLETE STRUCTURAL | | | SECTION/DETAIL WITH COMPLETE SPECIFICATIONS, | | | DIMENSIONS, HEIGHT, ETC.SEC. 106.1.2 CITY AMENDMENTS | | | TO FBC 2004. | | | | | | E) WINDOW SCHEDULE DOESN'T MATCH FLOOR PLAN. REVISE | | | AS REQUIRED. | | | | | | 11- SHEET A-3:A) PROVIDE ONLY THE INFORMATION THAT IS | | | RELEVANT TO THIS PROJECT. THERE ARE A LOT OF NOTES AND | | | TABLES THAT DON'T APPLY TO THIS PROJECT. | | | | | | B) REVISE CODE INFORMATION.CODE THAT APPLIES TO | | | THIS PROJECT IS 2004 FLORIDA RESIDENTIAL CODE. WHEN | | | REFERENCINGASCE7,THEN, THE CORRECT EDITION IS | | | 2002, NOT 2005. REVISE AS REQUIRED. | | | | | | C) TRUSS CONNECTOR SCHEDULE AND CONNECTORS SPECIFIED | | | ON ROOF FRAMING PLAN DON'T MATCH. REVISE AS REQUIRED. | | | | | | D) REVISE NUMBER AND TYPE OF FASTENERS SPECIFIED ON | | | TRUSS CONNECTOR SCHEDULE. SEE CURRENT CATALOGUE FOR | | | UPDATED INFORMATION. OTHERWISE, ENGINEER TO PROVIDE | | | COMPLETE ENGINEERING ANALYSIS SHOWING WHY CONNECTORS | | | ARE DIFFERENT THAN THOSE TESTED AND PUBLISHED BY THE | | | MANUFACTURER. SEC. 106.1.2 CITY AMENDMENTS TO FBC | | | 2004. | | | | | | E) MANUFACTURER FOR CONNECTORS SPECIFIED ON ROOF | | | FRAMING PLAN IS OUT OF BUSINESS. REVISE AS REQUIRED. | | | | | | F) CLEARLY IDENTIFY TRUSSES FOR WHICH UPLIFT | | | PRESSURES WERE CALCULATED. | | | | | | G) PROVIDE COMPLETE STRUCTURAL DETAILS/SPECS FOR | | | ROOF ABOVE ENTRY DOORS. SEC. 106.1.2 CITY AMENDMENTS TO | | | FBC 2004. | | | | | | H) ENGINEER TO COORDINATE ALL NOTES AND CHARTS SHOWN | | | ON THIS DRAWINGS. THERE IS A LOT OF MIXED INFORMATION | | | THAT NEEDS TO BE COORDINATED.SEE 2004 FLORIDA | | | RESIDENTIAL CODE AND ALLINFORMATION SUBMITTED IN THIS | | | SHEET.PROVIDE ONLY THE REQUIRED INFORMATION.SEE | | | SECTIONS . R301 2004 FLORIDA RESIDENTIAL CODE. ALSO, | | | SEE SEC. R803.2.3.1 OF 2004 FLORIDA RESIDENTIAL CODE | | | FOR MINIMUM REQUIREMENTS FOR ROOF SHEATHING. REVISE AND | | | COORDINATE ALL INFORMATION IN SHEET A-3 TO MATCH. | | | | | | I) PNEUMATIC FASTENING SCHEDULE: PROVIDE ONLY THE | | | INFORMATION THAT APPLIES TO THIS PROJECT.CHECK/REVISE | | | SPACING FOR BUCK DETAILS FASTENING. INFORMATION DOESN'T | | | MATCH. ALSO, COORDINATE WITH PROVIDED BUCK DETAIL. | | | | | | J) ROOF FRAMING PLAN CALLS DWELLING SEPARATION WALL | | | A "FIRE WALL".SEEFBC 2004 FOR CORRECT DEFINITION | | | FOR "FIRE WALL" AND REVISE AS REQUIRED. | | | | | | K) PROVIDE COMPLETE SECTION TRUH DWELLING SEPARATION | | | WALL TO SHOW COMPLIANCE WITH SEC. R317.1 2004 FLORIDA | | | RESIDENTIAL CODE. | | | | | | L) REVISE ATTIC VENTILATION CALCULATIONS AND NOTES | | | SEE SEC. R806 2004 FLORIDA RESIDENTIAL CODE FOR PROPER | | | INFORMATION. | | | | | | | | | 12- PRIOR TO SUBMITTAL TO THIS OFFICE BRING PLANS FOR | | | HISTORICAL APPROVAL AFTER CORRECTIONS ARE DONE TO THE | | | PLANS. | | | | | | 13- SHEET A-4:A) REVISE INTERIOR BEARING WALL TO | | | MATCH FLOOR PLAN. REVISE SIZE OF FOOTING, WALL | | | CONSTRUCTION, ETC. | | | | | | B) SPECIFY FIREBLOCKING ON INTERIOR BEARING WALL | | | SECTION AS REQUIRED BY SEC. R602.8 2004 FLORIDA | | | RESIDENTIAL CODE. | | | | | | B) PROVIDE DETAIL/SPECS FOR DWELLING SEPARATION AT | | | ATTIC AREA. SEC. R317.1 2004 FLORIDA RESIDENTIAL CODE. | | | | | | C) PROVIDE ALL DESIGN CRITERIA, INCLUDING ALL WIND | | | LOADS, AND LIVE AND DEAD LOADS. REFERENCE 2004 FLORIDA | | | RESIDENTIAL CODE,WHICH IS THE CODE THAT REGULATES | | | THIS BUILDING, NOT SECTIONS 1606 OF FBC 2004. SEE SEC. | | | R301 AND TABLE R301.5 OF 2004 FLORIDA RESIDENTIAL CODE. | | | REVISE AS REQUIRED. | | | | | | D) PLYWOOD NAILING NOTES TO MATCH INFORMATION ON | | | SHEET A-3 AFTER APPROPRIATE REVISIONS ARE DONE. | | | | | | E) TYPICAL WALL SECTION: | | | * WHAT IS D-30 INSULATION? | | | ** WHAT IS 6 MIL JISQUEEN? | | | *** WHAT IS 1/2" DRYWALL STRIPS AT 16"O.C.? | | | **** WHAT IS 2"X4" STRIP?. IS IT FIREBLOCKING?. ALSO, | | | VERIFY SIZE WITH SIZE OF FURRING STRIPS FOR DRYWALL | | | INSTALLATION. | | | ***** WHAT IS 325# SHINGLES? | | | ****** ROOF SHEATHIG SIZE AND TYPE TO MATCH INFORMATION | | | ON SHEET A-3 AFTER APPROPRIATE REVISIONS ARE DONE. | | | ******* TRUSS CONNECTOR TO MATCH INFORMATION ON SHEET | | | A-3 AFTER APPROPRIATE REVISIONS ARE DONE. | | | ******** SPECIFY FOOTING MIN. DEPTH AS REQUIRED BY SEC. | | | R 403.1.4 2004 FLORIDA RESIDENTIAL CODE. | | | ********* SPECIFY MINIMUM FINISH FLOOR AS REQUIRED BY | | | SEC. R404.1.6 2004 FLORIDA RESDIENTIAL CODE. | | | | | | 14- ENERGY CALCULATIONS:A) PROVIDE COMPLETE | | | INFORMATION ON TOP OF FORM. | | | | | | B) THIS IS A MULTIFAMILY BUILDING, NOT SINGLE | | | FAMILY. SEE DEFINITIONS ON SUBCHAPTER13-2 OF 2004 | | | FBC. REVISE AS REQUIRED. THEREFORE SEPARATE ENERGY | | | CALCULATIONS ARE REQUIRED. SEE SEC. 15-101.2.5.1 FBC | | | 2004. | | | | | | C) IF CALCULATIONS ARE NOT DONE FOR WORST CASE | | | SCENARIO, THEN THEY SHALL BE DONE ON ACTUAL BUILDING | | | ORIENTATION.ENERGY CALCULATIONS SUBMITTED ARE NOT FOR | | | WORST CASE SCENARIO AND BUILDING ORIENTATION DON'T | | | MATCH ACTUAL BUILDING ORIENTATION. SEE SURVEY AND | | | REVISE AS REQUIRED. | | | | | | D) OVERHANG LENGTH AND HEIGHT ARE INCORRECT.THEY | | | CAN'T BE ZERO. REVISE AS REQUIRED. | | | | | | 16- ENERGY CALCULATIONS ARE TAKINGTHE CEILING FAN | | | CREDIT. THEREFORE NEED TO SPECIFY CEILING FAN SIZE IN | | | ALL ROOMS AS REQUIRED BY TABLE 13-607.1.A.1 FBC 2004. | | | | | | 17- PROVIDE PRODUCT APPROVAL AS REQUIRED BY RULE 9B-72 | | | FOR: | | | A) SINGLE HUNG WINDOWS.TWO DIFFERENT PRODUCT | | | APPROVALS WERE SUBMITTED. ONLY THE ONE FOR LARGE | | | MISSILE IMPACT CAN BE USED FOR OPENINGS BELOW 30'-0" | | | HIGH. PROVIDE 2 COPIES. | | | | | | B) SHINGLES. | | | | | | C) BAHAMA SHUTTERS AND COLONIAL SHUTTERS SHOWN ON | | | EXTERIOR ELEVATIONS. AND PROVIDE COMPLETE INSTALLATION | | | SCHEDULE. SEE ATTACHED INSTALLATION SCHEDULE SAMPLE. | | | PROVIDE ALL REQUIRED INFORMATION. | | | | | | D) PRECAST LINTELS. | | | | | | E) ENTRY DOORS. | | | | | | F) REAR DOORS. | | | | | | G) ALL STRUCTURAL SIMPSON OR USP CONNECTORS | | | SPECIFIED ON PLANS ANDDETAILS. | | | | | | H) WINDOW MULLIONS AND SPECIFY FASTENING. | | | | | | 18- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-05-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-05-18 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-05-18 |
Time |
14:59 |
Sent To |
M |
|
| Notes |
| 2007-05-18 16:17:16 | ** UNSAT 3RDREVIEW ** | | | | | | | | | ** PLEASE SEE THERE ARE MANY COMMENTS FROM THE PREVIOUS | | | TWO REVIEWS WHICH ARE STILL IN NEED OF ADDRESSING. ANY | | | NEW COMMENTS ARE FROM CHANGES AND INFORMATION WHICH IS | | | NOW BEING SUBMITTED FOR THE FIRST TIME FOR REVIEW. | | | | | | ** PLEASE KNOW A RESPONSE LETTER FROM THE DESIGN | | | PROFESSIONAL IS MOST HELPFUL IN THE REVIEW PROCESS. | | | | | | ***IMPORANT*** | | | PLEASE ALSO KNOW DUE TO THE PLANS NOT BEING COMPLETE AT | | | THIS TIME AND THE FOLLOWING COMMENTS FOR PLANS | | | SUBMITTED, THERE MAY BE COMMENTS ON NEXT REVIEW WHICH | | | ARE NOT ON THIS REVIEW. | | | **** DUE TO THE EXTENT OF THE ELECTRICAL COMMENTS AND | | | OTHER COMMENTS BASED ON LICENSING, ONE SET OF THE | | | ELECTRICAL PLANS ARE ONCE AGAIN BEING RETAINED. PLEASE | | | SEE COMMENTS WITH RESPECT TO FLORIDA STATUTES FOR | | | REPEAT COMMENTS. | | | | | | | | | 1) NOTE: PLEASE SEE THERE ARE SEVERAL CODE COMPLIANT | | | SECTIONS WHICH HAVE BEEN REPEATED FOR THE THIRD REVIEW | | | AND A FEE FOR THE PLAN REVIEW PORTION OF THE PERMIT FEE | | | HAS NOW BEEN ASSESSED TO THE DESIGN PROFESSIONAL AS | | | REQUIRED UNDER FS 553.80(2)(B). THIS WAS GIVEN AS A | | | NOTICE ON PREVIOUS REVIEW AS SEVERAL CODES WERE | | | REPEATED IN THE 2ND REVIEW. PLEASE KNOW THAT THIS FEE | | | IS ASSESSED TO THE DESIGN PROFESSIONAL UNDER FLORIDA | | | STATUTES AND IS NOT THE RESPONSIBILITY OF CONTRACTOR OR | | | OWNER. THE PLANS RETAINED FROM BOTH PREVIOUS REVIEWS | | | AND THIS REVIEW WILL BE SENT TO THE FLORIDA BOARD OF | | | PROFESSIONAL ENGINEERS FOR REVIEW. THE FEE OF $3000.00 | | | IS DUE BEFORE ANY PLANS MAY BE RE-SUBMITTED FOR REVIEW | | | FOR THE 4TH REVIEW. | | | ** PLEASE ALSO KNOW THAT TO DATE OF THIS REVIEW, NO ONE | | | HAS CONTACTED THIS REVIEWER TO GO OVER ANY COMMENTS OR | | | QUESTIONS. | | | | | | 2) NOTE: PLEASE SEE NOTES AS PREVIOUSLY STATED WITH | | | RESPECT TO SIGNING OF PLANS. NO SIGNATURE VERIFICATION | | | LETTER WAS LOCATED IN PLANS. | | | PLEASE SEE PLANS SEEM TO BE SIGNED WITH AN INITIAL OF | | | SOME SORT. IF THIS IS INDEED THE LEGAL SIGNATURES OF | | | THE DESIGNER OF RECORD PLEASE PROVIDE A SIGNED, DATED | | | AND SEALED LETTER WITH STATEMENT OF LEGAL SIGNATURE. | | | FS 471.025 | | | PLEASE BE SURE LETTER IS PROPERLY NOTARIZED UNDER | | | FLORIDA STATUTES 117.05. | | | PLEASE KNOW THIS LETTER WILL BE PLACED IN OUR SIGNATURE | | | FILE FOR ANY FUTURE REFERENCE AS NEEDED AND WILL NOT BE | | | NEED TO PROVIDE LETTER ON FUTURE PROJECTS. | | | ** PLEASE KNOW, THIS IS REQUIRED FOR ALL SHEETS AND FOR | | | ALL TRADE REVIEWS WHETHER OR NOT COMMENT IS MADE BY | | | OTHER REVIEWER(S). | | | | | | 3) NOTE: THIS IS THE SAME COMMENT. ONLY THE NEC WAS | | | ADDED. | | | PLEASE SEE ONLY THE 2005 NEC WAS ADDED TO PLANS. | | | PLEASE SEE THE CODES WHICH WERE REQUESTED FOR OTHERS | | | WERE NOT ADDED. PLEASE SEE THAT ALL PLANS SHALL STATE | | | THE CODE IN WHICH THEY ARE DESIGNED UNDER. THIS IS | | | SUBMITTED UNDER THE NEW CODES. 2004 FBC W/ THE 2006 | | | REVISIONS. | | | | | | 4) NOTE:THIS IS THE SAME COMMENT FROM PREVIOUS | | | REVIEW. THIS IS ONE BUILDING BY DEFINITION AND ONLY ONE | | | SERVICE IS PERMITTED AND GROUPING OF MAINS IS REQUIRED. | | | PLEASE REVISE RISER FOR NEW SINGLE SERVICE. | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE CORRELATE RISER AND PLANS SUBMITTED. PLEASE SEE | | | PLANS DO NOT INDICATE GROUPING OF MAINS AS RISER SEEMS | | | TO SHOW. PLEASE SEE MISSING SERVICE ENTRANCE CONDUCTORS | | | FOR NEW RISER. | | | PLEASE SEE THE RISER AS SHOWN IS NOT CODE COMPLIANT | | | WITH SEVERAL SECTIONS OF THE NEC. PLEASE SEE OTHER | | | COMMENTS RELEVANT TO THE RISER. | | | THIS IS ONE *BUILDING* BY DEFINITION IN THE FBC AND | | | ONLY ONE SERVICE PER 230.2 WILL BE GRANTED. PLANS SHOW | | | TWO DIFFERENT LOCATIONS/SERVICE METERS. | | | 230.70, 230.72, 240.4, 310.16, 310.15B6, ETC. PLEASE | | | SEE THE SIZE OF THE METER CAN, CAN NOT BE VERIFIED AS | | | NO LOAD CALCULATIONS WERE SUBMITTED. FBC 106.1.2, | | | 106.3.5.4(PARA 8) ADMIN SECTION. THERE ARE CURRENTLY | | | MANY SECTIONS BESIDES THE ONES NOTED BELOW WHICH COULD | | | NOT BE ALL TYPED IN THIS REVIEW. | | | | | | 5) NOTE:THIS IS THE SAME COMMENT FROM PREVIOUS | | | REVIEW. RISER STILL SHOWS THIS. THIS NOTE AND CODE | | | SECTION WILL BE APPLICABLE FOR NEW SERVICE ALSO. | | | PLEASE SEE 250.6, 250.24B AS NO EQUIPMENT GROUNDING | | | CONDUCTORS ARE PERMITTED BEFORE THE FIRST MEANS OF | | | DISCONNECT. | | | | | | 6) NOTE:AS THE SERVICE WILL CHANGE, THIS SAME COMMENT | | | FROM PREVIOUS REVIEW WILL REMAIN. PLEASE SEE AS THE | | | SERVICE IS NOT COMPLETE AND THE SERVICE ENTRANCE | | | CONDUCTORS ARE NOT SHOWN REVIEW FOR CODE COMPLIANCE CAN | | | NOT BE DONE. BASED ON THE SIZE OF THE GEC AS SHOWN IT | | | DOES NOT MEET THE SECTION OF THE CODE PREVIOUSLY | | | GIVEN. | | | PLEASE SEE 250.66 AS THE SIZE OF SERVICE MAY CHANGE | | | WHICH WILL DICTATE THE SIZE OF THE GROUNDING ELECTRODE | | | CONDUCTOR. | | | | | | 7) NOTE: SAME NOTE, NOTHING CHANGED. PLANS DO NOT | | | INDICATE THE REQUIRED RATINGS FOR MAIN(S).PLEASE SEE | | | ONLY THE BRACE RATING AND BRANCH CIRCUIT RATING IS | | | BEING SHOWN FOR SUB PANEL(S). | | | PLEASE SUBMIT THE AIC RATINGS FOR SERVICE MAINS PER | | | 110.9. | | | PLEASE SEE THE RATING AS SHOWN ON PANEL SCHEDULE WAS | | | NOTED, HOWEVER NEEDED FOR MAIN(S). | | | | | | 8) NOTE:THIS IS THE SAME COMMENT. THE PANEL SCHEDULE | | | IS NOT COMPLETE AND LOAD CALCULATIONS ARE NOT COMPLETE. | | | WHERE ARE LOADS ON SERVICE FOR EACH PANEL AND SERVICE | | | AS SHOWN ON RISER? PLEASE COMPLETE AND SUBMIT A | | | COMPLETE PANEL SCHEDULE WITH ALL MINIMUM REQUIRED | | | DEDICATED LOADS AS WELL AS COMPLETED LOAD CALCULATIONS | | | BASED ON MINIMUM REQUIREMENTS FROM THE NEC. | | | PLEASE SEE THE SMALL APPLIANCE CIRCUITS ARE NOT | | | CORRECT, SHOWS 4500VA FOR TWO CIRCUITS? | | | PLEASE SEE THE WASHER/ LAUNDRY LOADS WHICH ARE NOT | | | CORRECT FOR MINIMUM LOADS PER NEC. | | | PLEASE SEE NO LOAD IS SHOWN FOR A/C SYSTEM. NO LARGER | | | LOADS? ETC. | | | PLEASE SEE 220.40, 220.82, 220.52, 220.54, 220.60, ETC, | | | ETC. | | | FBC ADMIN SECTION 106.3.5.4 | | | | | | 9) NOTE: THIS IS THE SAME COMMENT AS THE PANEL SCHEDULE | | | STILL INDICATE THE DEDICATE BATH RECEPTACLE CIRCUIT ON | | | WITH GARAGE RECEPTACLES. PLEASE SEE PLANS AS PLANS DO | | | NOT INDICATE ANY KIND OF GARAGE?? | | | PLEASE SEE 210.52D, 210.11C3, AS NO OTHER LOADS ARE | | | PERMITTED ON THE DEDICATED BATH CIRCUIT(S). | | | | | | 10) NOTE: THIS IS THE SAME COMMENT. | | | PLEASE SEE 210.52C1 FOR MISSING REQUIRED GFI'S ALONG | | | KITCHEN COUNTER SPACE. | | | MISSING MINIMUM VA 220.52 | | | | | | 11) NOTE:THIS IS THE SAME COMMENT.PLEASE SEE THAT | | | THE PANEL SCHEDULE INDICATES THE DINING ROOM | | | RECEPTACLES ON WITH LIGHTING AND MANY OTHER AREAS WHICH | | | ARE NOT PERMITTED. | | | NO INFORMATION WAS SUBMITTED. | | | PLEASE SEE MISSING REQUIRED CIRCUITING FOR DINING ROOM | | | RECEPTS PER 210.52B1, 210.11C1, AND 220. 52B. | | | | | | 12) NOTE:THIS COMMENT WILL REMAIN AS NOTED ABOVE IN | | | NOTE #9 THERE ARE RECEPTACLES ALONG KITCHEN COUNTER | | | SPACE WHICH ARE STILL MISSING. | | | PLEASE SEE 210.8A6, AS ALL RECEPTS ALONG KITCHEN | | | COUNTER SPACE SHALL BE SHOWN AS GFI. | | | | | | 13) NOTE:THIS COMMENT REMAINS AS THE MINIMUM | | | CLEARANCES IN SOME OF THE CLOSETS ARE NOT MET. PLEASE | | | SEE 410.8 AS THE PC LIGHTING IN CLOSETS ARE NOT | | | PERMITTED AS SHOWN. THEY DO NOT MEET MINIMUM | | | CLEARANCES. | | | | | | 14) NOTE: PLEASE GO OVER PLANS AS SCALE STILL SEEMS TO | | | SHOW SOME NOT SPACED PER 210.52 | | | PLEASE SEE MISSING RECEPTS PER 210.52 FOR WALL | | | SPACES. | | | PLEASE SEE PLANS ARE STILL MISSING RECEPTACLES PER | | | 210.52 | | | | | | 15) NOTE:THIS COMMENT IS THE SAME FROM PREVIOUS | | | REVIEW. PLEASE SEE ALL SMOKE DEVICES ARE STILL BEING | | | SHOWN AS *SMOKE DETECTORS* AND SYMBOL LEGEND EVENS | | | STATES AND SHOWS THESE BEING 110V UNITS WHICH THESE | | | WOULD BE *SMOKE ALARMS* | | | PLANS SHOW BOTH?? | | | PLEASE SEE ALL SMOKE DEVICES SHALL BE SHOWN AS DEFINED | | | IN NFPA-72. PLEASE SEE IF THESE DEVICES AS SHOWN ARE | | | PART OF A LOW VOLTAGE ALARM SYSTEM WHICH CONTAINS | | | HORN/ALARM DEVICES THEN THE SD AS SHOWN FOR SMOKE | | | DETECTOR IS OK. IF THESE DEVICES AS SHOWN ARE DETECT | | | AND SOUND AN ALARM, THEN THEY SHALL BE SHOWN AS SA FOR | | | SMOKE ALARMS. | | | PLEASE ALSO SEE NFPA-72 11.5.1.1, 11.8.3 FOR LOCATIONS | | | REQUIRED INSIDE AND OUTSIDE ALL SLEEPING ROOMS. PLEASE | | | SEE SOME ROOMS DO NOT INDICATE THE DEVICE OUTSIDE THE | | | SLEEPING ROOM, YET INDICATE TWO DEVICES INSIDE ROOM? | | | PLEASE SEE OTHER ROOMS WHICH DO INDICATE A DEVICE | | | OUTSIDE ROOM, BUT STILL INDICATE TWO OR MORE INSIDE?? | | | | | | 16) NOTE: THIS COMMENT IS THE SAME. NO CORRECTION WAS | | | MADE. | | | PLEASE SEE MISSING DISCONNECTS FOR ALL A/C EQUIPMENT. | | | PLEASE SEE 440.11. STILL SHOWN AS RECEPTACLES WHICH ARE | | | NOT PERMITTED. | | | PLEASE SEE AHU CLOSET APPEARS TO SHOW TWO RECEPTS. | | | PLEASE KNOW AS PER 422.31, AHU'S SHALL NOT BE PLUGGED | | | IN. | | | | | | 17) NOTE: THIS IS THE SAME COMMENT. | | | PLEASE SEE 422.31 FOR DISCONNECTING MEANS REQUIRED FOR | | | WATER HEATER(S). | | | | | | | | | 18) NOTE: PLEASE SEE 422.13 FOR REQUIRED LOAD | | | CALCULATIONS FOR WATER HEATERS AS PREVIOUS PLANS DID | | | NOT SHOW LOADS, THIS COMMENT IS NEW NOW THAT LOADS ARE | | | SHOWN. | | | | | | 19) NOTE:THIS IS THE SAME COMMENT AS PLANS ARE STILL | | | MISSING SEVERAL CIRCUITS WHICH THE REVIEW CAN NOT | | | DETERMINE SPECIFIC USE OF SOME WHICH MAY NEED TO BE | | | DEDICATED CIRCUITS ETC. | | | PLEASE SEE SEVERAL ELECTRICAL DEVICES ON PLANS WHICH | | | ARE MISSING CIRCUITING. THERE ARE MANY ITEMS WHICH NEED | | | CIRCUITING TO REVIEW FOR CODE COMPLIANCE. | | | FBC 106.1.2, 106.3.5.4 | | | | | | 20) NOTE: THIS IS THE SAME COMMENT AS THE CODE REQUIRES | | | *ALL OUTLETS* IN BEDROOMS TO CONTAIN ARC FAULT | | | PROTECTION PLEASE SEE MISSING ARC FAULT PROTECTION FOR | | | ALL OUTLETS IN BEDROOMS. 210.12 THIS IS NOT ONLY | | | REQUIRED FOR RECEPTACLES. | | | | | | 21) NOTE:THIS IS THE SAME COMMENT FROM PREVIOUS | | | REVIEW. | | | PLEASE SEE SOME RECEPTACLES ARE NOT BEING SHOWN | | | SWITCHING THE ENTIRE RECEPTACLES WHICH IS OK, HOWEVER | | | AS NOTED ABOVE PER 210.52, THEN RECEPTACLES WOULD BE | | | REQUIRED IN ADDITION FOR GENERAL PURPOSE. | | | | | | 22) NOTE: THIS IS THE SAME COMMENT PLEASE SEE PLANS | | | APPEAR TO NOW HAVE ONE NEW RECEPTACLE FOR WHAT APPEARS | | | TO BE FOR THE DISHWASHER AND DISPOSAL BUT IT IS UNCLEAR | | | AS ONE UNIT SHOWS THIS OUTLET AS GFI AND THE OTHER NOT | | | GFI PROTECTED. PLEASE SEE 210.4, IF THESE ARE ON THE | | | SAME YOKE/DEVICE THEN A 2-POLE BREAKER IS REQUIRED. | | | PLEASE ALSO SHOW AND IDENTIFY THE RECEPTACLE FOR THESE | | | ON PLANS. | | | | | | 23) NOTE:THIS IS THE SAME COMMENT FROM PREVIOUS | | | REVIEW. PLEASE SHOW ALL ROOM AND AREA DESIGNATIONS ON | | | PLANS IN ORDER TO REVIEW SOME CIRCUITING FOR CODE | | | COMPLIANCE. | | | FBC 106.1.2 ADMIN SECTION. | | | | | | 24) NOTE:PLEASE SEE AS THE ADDRESS HAS CHANGED, | | | PLEASE ADJUST TITLE BLOCKS AND REMOVE THE OLD 601 14TH | | | ST. | | | FAC 61G15-23, 61G1-16 | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-03-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-09 |
Time |
18:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-09 |
Time |
17:41 |
Sent To |
M |
|
| Notes |
| 2007-03-09 19:00:58 | ** UNSAT 2ND REVIEW ** | | | | | | | | | ** PLEASE SEE THERE ARE MANY COMMENTS FROM THE PREVIOUS | | | REVIEW WHICH ARE STILL IN NEED OF ADDRESSING ALONG WITH | | | SEVERAL NEW COMMENTS DUE TO CHANGES IN THE PLANS | | | SUBMITTED. | | | | | | ** PLEASE KNOW A RESPONSE LETTER FROM THE DESIGN | | | PROFESSIONAL IS MOST HELPFUL IN THE REVIEW PROCESS. | | | | | | *** PLEASE ALSO KNOW DUE TO THE PLANS NOT BEING | | | COMPLETE AT THIS TIME AND THE FOLLOWING COMMENTS FOR | | | PLANS SUBMITTED, THERE MAY BE COMMENTS ON NEXT REVIEW | | | WHICH ARE NOT ON THIS REVIEW. | | | **DUE TO THE EXTENT OF THE ELECTRICAL COMMENTS AND | | | OTHER COMMENTS BASED ON LICENSING, ONE SET OF THE | | | ELECTRICAL PLANS ARE ONCE AGAIN BEING RETAINED. PLEASE | | | SEE NEW COMMENTS ADDED TO THIS REVIEW AND COMMENT WITH | | | RESPECT TO FLORIDA STATUTES FOR REPEAT COMMENTS. | | | | | | 1) NOTE:PLEASE SEE THIS MOSTLY THE SAME COMMENT. ONLY | | | A NEW SEAL WAS USED WHEN PLANS WERE SIGNED AND SEALED. | | | PLEASE SEE THAT THE MISSING CA # IS STILL NOT ON ANY | | | TITLE BLOCKS. PLEASE SEE THE PRINTED NAME IS NOT THE | | | SAME AS IN SEAL. PLEASE SEE NO LETTER FOR SIGNATURE | | | VERIFICATION WAS SUBMITTED. PLEASE SEE FLORIDA | | | ADMINISTRATIVE CODE 61G15-23.002 FOR MISSING LICENSING | | | INFORMATION REQUIRED. PLEASE SEE MISSING CERTIFICATE OF | | | AUTHORIZATION NUMBER AND SOME SHEETS ARE NOT COMPLETE | | | WITH OTHER INFORMATION AS REQUIRED. | | | FLORIDA STATUTES 471.023 | | | PLEASE SEE PLANS SEEM TO BE SIGNED WITH AN INITIAL OF | | | SOME SORT. IF THIS IS INDEED THE LEGAL SIGNATURES OF | | | THE DESIGNER OF RECORD PLEASE PROVIDE A SIGNED, DATED | | | AND SEALED LETTER WITH STATEMENT OF LEGAL SIGNATURE. | | | PLEASE BE SURE LETTER IS PROPERLY NOTARIZED UNDER | | | FLORIDA STATUTES 117.05. | | | PLEASE KNOW THIS LETTER WILL BE PLACED IN OUR SIGNATURE | | | FILE FOR ANY FUTURE REFERENCE AS NEEDED AND WILL NOT BE | | | NEED TO PROVIDE LETTER ON FUTURE PROJECTS. | | | ** PLEASE KNOW, THIS IS REQUIRED FOR ALL SHEETS AND FOR | | | ALL TRADE REVIEWS WHETHER OR NOT COMMENT IS MADE BY | | | OTHER REVIEWER(S). | | | | | | 2) NOTE: PLEASE SEE ONLY THE 2005 NEC WAS ADDED TO | | | PLANS. PLEASE SEE THE CODES WHICH WERE REQUESTED FOR | | | OTHERS WERE NOT ADDED. PLEASE SEE THAT ALL PLANS SHALL | | | STATE THE CODE IN WHICH THEY ARE DESIGNED UNDER. THIS | | | IS SUBMITTED UNDER THE NEW CODES. 2004 FBC W/ THE 2006 | | | REVISIONS. | | | | | | PLEASE SEE THE FOLLOWING CODES SHALL BE STATED ON | | | PLANS. | | | NFPA-70 2005, 2002 NFPA-72 | | | PLEASE KNOW BASED ON THE FACT THAT THE PLANS WERE | | | SUBMITTED FOR PERMITTING AFTER THE DATE OF DEC 8TH, | | | 2006, THE PLANS SHALL BE DESIGNED UNDER THE 2005 NEC. | | | | | | 3) NOTE: PLEASE CORRELATE RISER AND PLANS SUBMITTED. | | | PLEASE SEE PLANS DO NOT INDICATE GROUPING OF MAINS AS | | | RISER SEEMS TO SHOW. PLEASE SEE MISSING SERVICE | | | ENTRANCE CONDUCTORS FOR NEW RISER. | | | PLEASE SEE THE RISER AS SHOWN IS NOT CODE COMPLIANT | | | WITH SEVERAL SECTIONS OF THE NEC. PLEASE SEE OTHER | | | COMMENTS RELEVANT TO THE RISER. | | | THIS IS ONE *BUILDING* BY DEFINITION IN THE FBC AND | | | ONLY ONE SERVICE PER 230.2 WILL BE GRANTED. PLANS SHOW | | | TWO DIFFERENT LOCATIONS/SERVICE METERS. | | | 230.70, 230.72, 240.4, 310.16, 310.15B6, ETC. PLEASE | | | SEE THE SIZE OF THE METER CAN, CAN NOT BE VERIFIED AS | | | NO LOAD CALCULATIONS WERE SUBMITTED. FBC 106.1.2, | | | 106.3.5.4(PARA 8) ADMIN SECTION. THERE ARE CURRENTLY | | | MANY SECTIONS BESIDES THE ONES NOTED BELOW WHICH COULD | | | NOT BE ALL TYPED IN THIS REVIEW. | | | | | | 4) NOTE:THIS IS THE SAME COMMENT FROM PREVIOUS | | | REVIEW. | | | PLEASE SEE 250.6, 250.24B AS NO EQUIPMENT GROUNDING | | | CONDUCTORS ARE PERMITTED BEFORE THE FIRST MEANS OF | | | DISCONNECT. | | | | | | 5) NOTE: THIS IS THE SAME COMMENT FROM PREVIOUS REVIEW. | | | PLEASE SEE AS THE SERVICE IS NOT COMPLETE AND THE | | | SERVICE ENTRANCE CONDUCTORS ARE NOT SHOWN REVIEW FOR | | | CODE COMPLIANCE CAN NOT BE DONE. BASED ON THE SIZE OF | | | THE GEC AS SHOWN IT DOES NOT MEET THE SECTION OF THE | | | CODE PREVIOUSLY GIVEN. | | | PLEASE SEE 250.66 AS THE SIZE OF SERVICE MAY CHANGE | | | WHICH WILL DICTATE THE SIZE OF THE GROUNDING ELECTRODE | | | CONDUCTOR. | | | | | | 6) NOTE: NO, PLEASE SEE ONLY THE BRACE RATING AND | | | BRANCH CIRCUIT RATING IS BEING SHOWN. | | | PLEASE SUBMIT THE AIC RATINGS FOR SERVICE MAINS PER | | | 110.9. | | | PLEASE SEE THE RATING AS SHOWN ON PANEL SCHEDULE WAS | | | NOTED, HOWEVER NEEDED FOR MAIN(S). | | | | | | 7) NOTE:THIS IS THE SAME COMMENT. PANEL SCHEDULE IS | | | COMPLETELY BLANK FOR LOAD CALCULATIONS AND FOR LOAD ON | | | SERVICE FOR EACH PANEL AND SERVICE AS SHOWN ON RISER. | | | PLEASE COMPLETE AND SUBMIT A COMPLETE PANEL SCHEDULE | | | WITH ALL MINIMUM REQUIRED DEDICATED LOADS AS WELL AS | | | COMPLETED LOAD CALCULATIONS BASED ON MINIMUM | | | REQUIREMENTS FROM THE NEC. | | | PLEASE SEE 220.40, 220.82, 220.52, 220.54, 220.60, ETC, | | | ETC. | | | FBC ADMIN SECTION 106.3.5.4 | | | | | | 8) NOTE: THIS IS THE SAME COMMENT AS THE PANEL SCHEDULE | | | STILL INDICATE THE DEDICATE BATH RECEPTACLE CIRCUIT ON | | | WITH GARAGE RECEPTACLES. PLEASE SEE PLANS AS PLANS DO | | | NOT INDICATE ANY KIND OF GARAGE?? | | | PLEASE SEE 210.52D, 210.11C3, AS NO OTHER LOADS ARE | | | PERMITTED ON THE DEDICATED BATH CIRCUIT(S). | | | | | | 9) NOTE: THIS IS THE SAME COMMENT. | | | PLEASE SEE 210.52C1 FOR MISSING REQUIRED GFI'S ALONG | | | KITCHEN COUNTER SPACE. | | | MISSING MINIMUM VA 220.52 | | | | | | 10) NOTE:THIS IS THE SAME COMMENT.PLEASE SEE THAT | | | THE PANEL SCHEDULE INDICATES THE DINING ROOM | | | RECEPTACLES ON WITH LIGHTING AND MANY OTHER AREAS WHICH | | | ARE NOT PERMITTED. | | | NO INFORMATION WAS SUBMITTED. | | | PLEASE SEE MISSING REQUIRED CIRCUITING FOR DINING ROOM | | | RECEPTS PER 210.52B1, 210.11C1, AND 220. 52B. | | | | | | 11) NOTE:THIS COMMENT WILL REMAIN AS NOTED ABOVE IN | | | NOTE #9 THERE ARE RECEPTACLES ALONG KITCHEN COUNTER | | | SPACE WHICH ARE STILL MISSING. | | | PLEASE SEE 210.8A6, AS ALL RECEPTS ALONG KITCHEN | | | COUNTER SPACE SHALL BE SHOWN AS GFI. | | | | | | 12) NOTE: THIS COMMENT REMAINS AS THE MINIMUM | | | CLEARANCES IN SOME OF THE CLOSETS ARE NOT MET. PLEASE | | | SEE 410.8 AS THE PC LIGHTING IN CLOSETS ARE NOT | | | PERMITTED AS SHOWN. THEY DO NOT MEET MINIMUM | | | CLEARANCES. | | | | | | 13) NOTE: PLEASE GO OVER PLANS AS SCALE STILL SEEMS TO | | | SHOW SOME NOT SPACED PER 210.52 | | | PLEASE SEE MISSING RECEPTS PER 210.52 FOR WALL | | | SPACES. | | | | | | 14) NOTE:THIS COMMENT IS FROM PREVIOUS REVIEW. PLEASE | | | SEE ALL SMOKE DEVICES ARE STILL BEING SHOWN AS *SMOKE | | | DETECTORS* AND SYMBOL LEGEND EVENS STATES AND SHOWS | | | THESE BEING 110V UNITS WHICH THESE WOULD BE *SMOKE | | | ALARMS* | | | PLEASE SEE ALL SMOKE DEVICES SHALL BE SHOWN AS DEFINED | | | IN NFPA-72. PLEASE SEE IF THESE DEVICES AS SHOWN ARE | | | PART OF A LOW VOLTAGE ALARM SYSTEM WHICH CONTAINS | | | HORN/ALARM DEVICES THEN THE SD AS SHOWN FOR SMOKE | | | DETECTOR IS OK. IF THESE DEVICES AS SHOWN ARE DETECT | | | AND SOUND AN ALARM, THEN THEY SHALL BE SHOWN AS SA FOR | | | SMOKE ALARMS. | | | PLEASE ALSO SEE NFPA-72 11.5.1.1, 11.8.3 FOR LOCATIONS | | | REQUIRED INSIDE AND OUTSIDE ALL SLEEPING ROOMS. PLEASE | | | SEE SOME ROOMS DO NOT INDICATE THE DEVICE OUTSIDE THE | | | SLEEPING ROOM, YET INDICATE TWO DEVICES INSIDE ROOM? | | | PLEASE SEE OTHER ROOMS WHICH DO INDICATE A DEVICE | | | OUTSIDE ROOM, BUT STILL INDICATE TWO OR MORE INSIDE?? | | | | | | 15) NOTE: THIS COMMENT IS THE SAME. NO CORRECTION WAS | | | MADE. | | | PLEASE SEE MISSING DISCONNECTS FOR ALL A/C EQUIPMENT. | | | PLEASE SEE 440.11. | | | PLEASE SEE AHU CLOSET APPEARS TO SHOW TWO RECEPTS. | | | PLEASE KNOW AS PER 422.31, AHU'S SHALL NOT BE PLUGGED | | | IN. | | | | | | 16) NOTE: THIS IS THE SAME COMMENT. | | | PLEASE SEE 422.31 FOR DISCONNECTING MEANS REQUIRED FOR | | | WATER HEATER(S). | | | | | | 17) NOTE: OK. | | | | | | 18) NOTE: OK. | | | | | | ** NEW NOTES** | | | | | | 19) NOTE: PLEASE SEE SEVERAL ELECTRICAL DEVICES ON | | | PLANS WHICH ARE MISSING CIRCUITING. THERE ARE MANY | | | ITEMS WHICH NEED CIRCUITING TO REVIEW FOR CODE | | | COMPLIANCE. | | | FBC 106.1.2, 106.3.5.4 | | | | | | 20) NOTE: PLEASE SEE MISSING ARC FAULT PROTECTION FOR | | | ALL OUTLETS IN BEDROOMS. 210.12 THIS IS NOT ONLY | | | REQUIRED FOR RECEPTACLES. | | | | | | 21) NOTE: PLEASE SEE SOME RECEPTACLES ARE NOT BEING | | | SHOWN SWITCHING THE ENTIRE RECEPTACLES WHICH IS OK, | | | HOWEVER AS NOTED ABOVE PER 210.52, THEN RECEPTACLES | | | WOULD BE REQUIRED IN ADDITION FOR GENERAL PURPOSE. | | | | | | 22) NOTE: PLEASE SEE PLANS APPEAR TO NOW HAVE ONE NEW | | | RECEPTACLE FOR WHAT APPEARS TO BE FOR THE DISHWASHER | | | AND DISPOSAL BUT IT IS UNCLEAR AS ONE UNIT SHOWS THIS | | | OUTLET AS GFI AND THE OTHER NOT GFI PROTECTED. PLEASE | | | SEE 210.4, IF THESE ARE ON THE SAME YOKE/DEVICE THEN A | | | 2-POLE BREAKER IS REQUIRED. | | | PLEASE ALSO SHOW AND IDENTIFY THE RECEPTACLE FOR THESE | | | ON PLANS. | | | | | | 23) NOTE: PLEASE SHOW ALL ROOM AND AREA DESIGNATIONS ON | | | PLANS IN ORDER TO REVIEW SOME CIRCUITING FOR CODE | | | COMPLIANCE. | | | FBC 106.1.2 ADMIN SECTION. | | | | | | 24) NOTE: PLEASE SEE FLORIDA STATUTES 553.80(2)(B) WITH | | | RESPECT TO DESIGN PROFESSIONALS AND REPEAT COMMENTS FOR | | | CODE COMPLIANCE. | | | PLEASE KNOW THAT DUE TO THE AMOUNT OF ELECTRICAL | | | COMMENTS PLANS WILL BE RETAINED BY THIS OFFICE. PLEASE | | | KNOW PLANS WILL BE SUBMITTED TO THE FLORIDA BOARD OF | | | PROFESSIONAL ENGINEERS FOR REVIEW ITEMS ON PLANS AND | | | MISSING LICENSE AS REQUIRED UNDER THE FLORIDA STATUTES | | | AND FLORIDA ADMINISTRATIVE CODE. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-12-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-17 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-17 |
Time |
15:25 |
Sent To |
Z |
|
| Notes |
| 2006-12-17 16:22:02 | *** UNSAT *** | | | | | | *** PLEASE KNOW DUE TO THE PLANS NOT BEING COMPLETE AT | | | THIS TIME AND ALSO THE FOLLOWING COMMENTS FOR PLANS | | | SUBMITTED, THERE MAY BE COMMENTS ON NEXT REVIEW WHICH | | | ARE NOT ON THIS REVIEW. | | | **DUE TO THE EXTENT OF THE ELECTRICAL COMMENTS AND | | | OTHER COMMENTS BASED ON LICENSING, ONE SET OF THE | | | ELECTRICAL PLANS ARE BEING RETAINED BY THIS OFFICE. | | | | | | 1) NOTE:PLEASE SEE FLORIDA ADMINISTRATIVE CODE | | | 61G15-23.002 FOR MISSING LICENSING INFORMATION | | | REQUIRED. PLEASE SEE MISSING CERTIFICATE OF | | | AUTHORIZATION NUMBER AND SOME SHEETS ARE NOT COMPLETE | | | WITH OTHER INFORMATION AS REQUIRED. | | | FLORIDA STATUTES 471.023 | | | PLEASE ALSO SEE 61G15-23.001 FOR MINIMUM SIZE OF SEAL. | | | THE SIZE AS SHOWN ON PLANS DO NOT APPEAR TO BE LARGE | | | ENOUGH? | | | PLEASE SEE PLANS SEEM TO BE SIGNED WITH AN INITIAL OF | | | SOME SORT. IF THIS IS INDEED THE LEGAL SIGNATURES OF | | | THE DESIGNER OF RECORD PLEASE PROVIDE A SIGNED, DATED | | | AND SEALED LETTER WITH STATEMENT OF LEGAL SIGNATURE. | | | PLEASE BE SURE LETTER IS PROPERLY NOTARIZED UNDER | | | FLORIDA STATUTES 117.05. | | | PLEASE KNOW THIS LETTER WILL BE PLACED IN OUR SIGNATURE | | | FILE FOR ANY FUTURE REFERENCE AS NEEDED AND WILL NOT BE | | | NEED TO ROVIDE LETTER ON FUTURE PROJECTS. | | | ** PLEASE KNOW, THIS IS REQUIRED FOR ALL SHEETS AND FOR | | | ALL TRADE REVIEWS WHETHER OR NOT COMMENT IS MADE BY | | | OTHER REVIEWER(S). | | | | | | 2) NOTE: PLEASE SEE THE FOLLOWING CODES SHALL BE STATED | | | ON PLANS. | | | NFPA-70 2005, 2002 NFPA-72 | | | PLEASE KNOW BASED ON THE FACT THAT THE PLANS WERE | | | SUBMITTED FOR PERMITTING AFTER THE DATE OF DEC 8TH, | | | 2006, THE PLANS SHALL BE DESIGNED UNDER THE 2005 NEC. | | | | | | 3) NOTE: PLEASE CORRELATE RISER AND PLANS SUBMITTED. | | | PLANS AND PERMIT APPLICATION IS FOR A DUPLEX DWELLING | | | UNIT TO BE BUILT, (NOT YET APPROVED OR DISAPPROVED BY | | | ZONING) YET RISER SHOWS SINGLE METER AND PLANS SHOW | | | TWO? | | | PLEASE SEE RISER AS SHOWN MAY NOT FEED PANELS AS SHOWN. | | | PLEASE SEE 240.21C FOR TAPPED CONDUCTORS. | | | PLEASE SEE THE SIZE OF THE METER CAN, CAN NOT BE | | | VERIFIED AS NO LOAD CALCULATIONS WERE SUBMITTED. FBC | | | 106.1.2, 106.3.5.4(PARA 8) ADMIN SECTION. THERE ARE | | | CURRENTLY MANY SECTIONS BESIDES THE ONES NOTED BELOW | | | WHICH COULD NOT BE ALL TYPED IN THIS REVIEW. | | | | | | 4) NOTE: PLEASE SEE 250.6, 250.24B AS NO EQUIPMENT | | | GROUNDING CONDUCTORS ARE PERMITTED BEFORE THE FIRST | | | MEANS OF DISCONNECT. | | | | | | 5) NOTE: PLEASE SEE 250.66 AS THE SIZE OF SERVICE MAY | | | CHANGE WHICH WILL DICTATE THE SIZE OF THE GROUNDING | | | ELECTRODE CONDUCTOR. | | | | | | 6) NOTE: PLEASE SUBMIT THE AIC RATINGS FOR SERVICE | | | MAINS PER 110.9. | | | PLEASE SEE THE RATING AS SHOWN ON PANEL SCHEDULE WAS | | | NOTED, HOWEVER NEEDED FOR MAIN(S). | | | | | | 7) NOTE: PLEASE COMPLETE AND SUBMIT A COMPLETE PANEL | | | SCHEDULE WITH ALL MINIMUM REQUIRED DEDICATED LOADS AS | | | WELL AS COMPLETED LOAD CALCULATIONS BASED ON MINIMUM | | | REQUIREMENTS FROM THE NEC. | | | PLEASE SEE 220.40, 220.82, 220.52, 220.54, 220.60, ETC, | | | ETC. | | | FBC ADMIN SECTION 106.3.5.4 | | | | | | 8) NOTE: PLEASE SEE 210.52D, 210.11C3,A S NO OTHER | | | LOADS ARE PERMITTED ON THE DEDICATED BATH CIRCUIT(S). | | | | | | 9) NOTE: PLEASE SEE 210.52C1 FOR MISSING REQUIRED GFI'S | | | ALONG KITCHEN COUNTER SPACE. | | | MISSING MINIMUM VA 220.52 | | | | | | 10) NOTE: PLEASE SEE MISSING REQUIRED CIRCUITING FOR | | | DINING ROOM RECEPTS PER 210.52B1, 210.11C1, AND 220. | | | 52B. | | | | | | 11) NOTE: PLEASE SEE 210.8A6, AS ALL RECEPTS ALONG | | | KITCHEN COUNTER SPACE SHALL BE SHOWN AS GFI. | | | | | | 12) NOTE: PLEASE SEE 410.8 AS THE PC LIGHTING IN | | | CLOSETS ARE NOT PERMITTED AS SHOWN. THEY DO NOT MEET | | | MINIMUM CLEARANCES. | | | | | | 13) NOTE: PLEASE SEE MISSING RECEPTS PER 210.52 FOR | | | WALL SPACES. | | | | | | 14) NOTE: PLEASE SEE ALL SMOKE DEVICES SHALL BE SHOWN | | | AS DEFINED IN NFPA-72. PLEASE SEE IF THESE DEVICES AS | | | SHOWN ARE PART OF A LOW VOLTAGE ALARM SYSTEM WHICH | | | CONTAINS HORN/ALARM DEVICES THEN THE SD AS SHOWN FOR | | | SMOKE DETECTOR IS OK. IF THESE DEVICES AS SHOWN ARE | | | DETECT AND SOUND AN ALARM, THEN THEY SHALL BE SHOWN AS | | | SA FOR SMOKE ALARMS. | | | PLEASE ALSO SEE NFPA-72 11.5.1.1, 11.8.3 FOR LOCATIONS | | | REQUIRED INSIDE AND OUTSIDE ALL SLEEPING ROOMS. PLEASE | | | SEE SOME ROOMS DO NOT INDICATE THE DEVICE OUTSIDE THE | | | SLEEPING ROOM, YET INDICATE TWO DEVICES INSIDE ROOM? | | | PLEASE SEE OTHER ROOMS WHICH DO INDICATE A DEVICE | | | OUTSIDE ROOM, BUT STILL INDICATE TWO OR MORE INSIDE?? | | | | | | 15) NOTE: PLEASE SEE MISSING DISCONNECTS FOR ALL A/C | | | EQUIPMENT. PLEASE SEE 440.11. | | | PLEASE SEE AHU CLOSET APPEARS TO SHOW TWO RECEPTS. | | | PLEASE KNOW AS PER 422.31, AHU?S SHALL NOT BE PLUGGED | | | IN. | | | | | | 16) NOTE: PLEASE SEE 422.31 FOR DISCONNECTING MEANS | | | REQUIRED FOR WATER HEATER(S). | | | | | | 17) NOTE: PLEASE CLARIFY ROOMS WHICH INDICATE A J-BOX | | | FOR "PUT-FAN" AS STATED ON PLANS. PLEASE CLARIFY WHAT | | | THIS IS? SYMBOL LEGEND DOES NOT ELABORATE ON THIS. | | | | | | 18) NOTE: PLEASE KNOW SEPARATE PLANS, AND PERMIT | | | APPLICATIONS REQUIRED FOR LOW VOLTAGE , PHONE, CATV OR | | | BURGLAR ALARM SYSTEMS. | | | | | | ** PLEASE KNOW SERVICE AND PROPOSED STRUCTURE MAY BE | | | GREATLY AFFECT BY ANY POSSIBLE ZONING COMMENTS FOR | | | SERVICE. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2007-06-06 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-06-06 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-06-06 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2007-06-06 09:38:06 | ** FAILED ** | | | | | | 1. SIDEWALK ALONG ON HENRIETA AVE SHOULD BE 5 FEET WIDE | | | INSTEAD OF 4.7 FEET. | | | 2. ALL SIDE WALK, DRIVEWAY, APPROACHES IN CITY'S RIGHT | | | OF WAY MUST BE APPROVED FROM WINDEL PALMER, 494-1040, | | | 1000 45TH STREET | | | 3. PLEASE SHOW LOCATIONS OF DRIVEWAY, APPROACHES ON THE | | | DRAWING. | | | 4. MUST MEET CITY'S STANDARDS FOR | | | DRIVEWAY,APPROACH,SIDEWALK ETC.,YOU CAN GET A C.D. FOR | | | ALL CITY'S STANDARDS FROM 1000 45TH STREET | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-05-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-18 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-18 |
Time |
11:56 |
Sent To |
E |
|
| Notes |
| 2007-05-18 11:57:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-05-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-15 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-15 |
Time |
11:14 |
Sent To |
Z |
|
| Notes |
| 2007-05-15 11:14:40 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-03-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-09 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-09 |
Time |
14:01 |
Sent To |
E |
|
| Notes |
| 2007-03-09 14:02:16 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-03-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-03 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-03 |
Time |
14:05 |
Sent To |
Z |
|
| Notes |
| 2007-03-03 14:05:50 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-01-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-01-29 |
Time |
18:59 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2006-12-17 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2006-12-17 14:40:33 | TO "SFR" "E" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-05-21 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-05-21 |
Time |
08:55 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-05-21 |
Time |
08:55 |
Sent To |
P |
|
| Notes |
| 2007-05-21 08:58:48 | *** DENIED *** | | | 1) SEE TITLE BLOCK ON PLANS SHOW THE WRONG JOB ADDRESS, | | | PLEASE CORRECT. | | | | | | 2) AS NOTED IN LAST TWO REVIEWS 3-12-07 NOTE #3 AND | | | 12-19-07 NOTE #2. PLEASE SEE THE COOLING LOAD | | | CALCULATIONS ARE CALLING FOR 13,331 SENSIBLE BTU'S, THE | | | MECHANICAL PLANS ARE CALLING FOR 24,800 SENSIBLE BTU'S, | | | THE PLANS CAN ONLY CALL FOR 15% MORE SENSIBLE BTU'S | | | THAN THE COOLING LOAD CALCULATIONS, SEE 2004 FBC | | | 13-607.1.ABC.1.1 (12-8-06 REVISION). PLEASE CORRECT. | | | | | | 3) AS NOTED IN LAST REVIEW 3-12-07 NOTE #5. SEE ENERGY | | | CALCULATIONS #15 IS TAKING THE CF (CEILING FAN) CREDIT, | | | ELECTRICAL PLANS SHOW FUTURE FANS, CREDIT MAY NOT BE | | | TAKEN FOR FUTURE WORK, SEE 2004 FBC 13-607.2.A.3.1. | | | PLEASE CORRECT. | | | | | | 4) ENERGY CALCULATIONS ARE FOR 2292 SQUARE FEET (BOTH | | | UNITS) BUT LINES 12, 13, AND 14 SHOW ONLY ONE A/C | | | SYSTEM, ONE HEATER AND ONE WATER HEATER, . WILL NEED TO | | | SHOW TWO OF EACH OR SUBMIT TWO SEPARATE ENERGY | | | CALCULATIONS FOR EACH UNIT AND CORRECT TOTAL SQUARE | | | FEET, PLEASE CORRECT. | | | | | | 5) ENERGY CALCULATIONS LINE 12 SHOWS 29,200 TOTAL | | | COOLING BTU'S., MECHANICAL PLANS EQUIPMENT LISTING | | | SHOWS 33,200 TOTAL COOLING BTU'S., THE TWO MUST | | | COINCIDE PLEASE CORRECT. | | | | | | 6) ENERGY CALCULATIONS LINE 13 SHOWS 34.000 TOTAL | | | HEATING BTU'S., MECHANICAL PLANS SHOW 24,000 TOTAL | | | HEATING BTU'S., THE TWO MUST COINCIDE PLEASE CORRECT. | | | | | | 7) PLEASE SEE ELECTRICAL REVIEW NOTE #1 AS THIS ALSO | | | APPLIES TO THE MECHANICAL REVIEW. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-03-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-12 |
Time |
09:41 |
Rev Time |
1.15 |
| Received By |
tgordon |
Date |
2007-03-12 |
Time |
09:41 |
Sent To |
P |
|
| Notes |
| 2007-03-12 10:04:24 | *** DENIED *** | | | 1) SEE MECHANICAL PLANS PAGE MEP-2 OF 2 "A/C NOTES", | | | 10,000 TOTAL, 1410KW, AND 13,331 SENS, IS INCORRECT FOR | | | A THREE TON A/C SYSTEM, PLEASE OBTAIN THE | | | MANUFACTURER'S SPECIFICATION'S AND INTER THE CORRECT | | | INFORMATION. | | | | | | 2) COULD NOT FIND THE TRANE A/C SYSTEM LISTED ON THE | | | PLANS IN THE ARI DIRECTORY, PLEASE SUBMIT DETAILED | | | MANUFACTURER'S SPECIFICATION'S AND INSTALLATION | | | INSTRUCTIONS FOR A/C SYSTEM TO BE INSTALLED. | | | | | | 3) AS NOTED IN LAST REVIEW 12/19/06 NOTE #2. PLEASE SEE | | | THE MANUAL J CALCULATIONS ARE CALLING FOR A SMALLER A/C | | | SYSTEM THEN THE MECHANICAL PLANS ARE, THEIR FORTHE | | | PLANS WOULD NEED TO LIST A SMALLER A/C SYSTEM TO BE | | | INSTALLED, SEE 2004 FBC 13-607.ABC.1.1. | | | | | | 4) AS NOTED IN LAST REVIEW 12/19/06 NOTE #3. THE ENERGY | | | CALCULATIONS SUBMITTED ARE INCORRECT, PLEASE SUBMIT | | | CORRECTED ENERGY CALCULATIONS, SEE 2004 FBC 13-101.2. | | | | | | 5) SEE ENERGY CALCULATIONS #15 IS TAKING THE CF CREDIT, | | | ELECTRICAL PLANS SHOW FUTURE FANS, CREDIT MAY NOT BE | | | TAKEN FOR FUTURE WORK. | | | | | | 6) PLEASE SEE YELLOW HIGH LIGHTS ON ENERGY CALCULATIONS | | | AND MECHANICAL PLANS, PLEASE CORRECT. | | | | | | 7) AS NOTED IN LAST REVIEW 12/19/06 NOTE #4.THE 12X6 | | | RETURN AIR TRANSFER GRILLS TO THE BEDROOMS ARE TO | | | SMALL. BALANCED RETURN AIR MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY INCREASING THE | | | RETURN TRANSFER ONE AND ONE HALF TIMES THE CROSS | | | SECTIONAL AREA (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING AND THE DOOR | | | HAVING AT LEAST AN UNRESTRICTED 1 INCHUNDERCUT TO | | | ACHIEVE PROPER RETURN AIR BALANCE. | | | (B)TRANSFER GRILLES SHALL USE 50 SQUARE INCHES (OF | | | GRILLE AREA) TO 100 CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND USING AN | | | UNRESTRICTED 1-INCH UNDERCUTTING OF DOORS TO ACHIEVE | | | PROPER RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE REQUIRED TO MEET | | | THESE REQUIREMENTS FOR PROPER BALANCED RETURN AIR | | | EXCLUDING BATHROOMS, CLOSETS, STORAGE ROOMS AND LAUNDRY | | | ROOMS, EXCEPT THAT ALL SUPPLY AIR INTO THE MASTER SUITE | | | SHALL BE INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | 8) MECHANICAL PLANS NOW SHOW NEW 12X12 GRILLS AND | | | UNKNOWN DUCTS (YELLOW HIGH LIGHTED) IN EACH ROOM, | | | PLEASE REMOVE OR CORRECT. | | | | | | 9) SEE TITLE BLOCK ON PLANS IS SHOWING D M & L | | | ENGINEERING CORP. "C.O.A. #10784" . CHECKED DBPR WEB | | | SITE AND FOUND NO C. O. A. NUMBER OR COMPANY LISTED. | | | SEE FAC 61G15-23.002 (2) AND COMPLY. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-12-19 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-12-19 |
Time |
11:11 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-12-19 |
Time |
11:11 |
Sent To |
Z |
|
| Notes |
| 2006-12-19 11:39:10 | *** DENIED *** | | | 1) DM&L ENGINEERING CORP. NEED THEIR CERTIFICATE OF | | | AUTHORIZATION NUMBER IN THE TITLE BLOCK, SEE FAC | | | 61G15-23.002. | | | | | | 2) MANUAL J CALCULATIONS ARE CALLING FOR 13,331 | | | SENSIBLE BTU'S., THE MECHANICAL PLANS ARE CALLING FOR | | | 26,200 SENSIBLE BTU'S., THE PLANS CAN ONLY CALL FOR 20% | | | MORE THAN THE MANUAL J CAL'S., SEE 2004 FBC | | | 13-607.ABC.1.1. | | | | | | 3) ENERGY CALCULATIONS ARE CALLING FOR 10,000 BTU | | | COOLING SYSTEM AND 10,000 BTU (=2.9 KW) HEATING SYSTEM, | | | THE MECHANICAL PLANS ARE CALLING FOR 34,000 BTU COOLING | | | AND 10 KW (=34,000 BTU) HEATING. THE ENERGY CAL'S. AND | | | MECHANICAL PLANS MUST COINCIDE, PLEASE CORRECT. | | | | | | 4) THE RETURN AIR TRANSFER GRILLS TO THE BEDROOMS ARE | | | TO SMALL, | | | BALANCED RETURN AIR MAY BE ACHIEVED BY. | | | (B)TRANSFER GRILLES SHALL USE 50 | | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | | CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND | | | USING AN UNRESTRICTED 1-INCH | | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | | RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2007-05-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-05-23 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-05-23 |
Time |
08:26 |
Sent To |
B |
|
| Notes |
| 2007-05-23 08:36:18 | DENIED; | | | 1. RISER DIAGRAM; | | | A) TUB NOT VENTED | | | B) KITCHEN SINK NEED A VENT | | | C)EXTRA BATHROOM ON RISER DIAGRAM | | | 2. PLUMBING NOTES; | | | A) NOTE 5, DELETE AIR CHAMBERS FROM NOTE, NO | | | REFERENCE TO AIR CHAMBERS IN PLUMBING CODE. | | | B) NOTE 9 CHANGE NOTE TO " WASTE LINES 3" AND | | | LARGER CAN SLOP 1/8" PER FT, PIPE 2 1/2 " TO SLOP 1/4 " | | | PER FT. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-03-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-03-14 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-03-14 |
Time |
13:35 |
Sent To |
B |
|
| Notes |
| 2007-03-14 14:05:56 | DENIED; | | | 1. CA# MISSING FROM TITLE BLOCK | | | 2. PLUMBING NOTES;NOTE# 5. WATER HAMMER ARRESTORS TO | | | BE USED PER FBC-2004 PLUMBING SECTION 604.9. AIR | | | CHAMBERS ARE NOT AND ENGINEERED AND APPROVED PRODUCT. | | | NOTE# 9HORIZONTAL DRAIN LINES TO SLOPE PER TABLE | | | 704.1 PIPES LESS THAN 2 1/2" IN DIAMETER OR SMALLER | | | MUST SLOPE 1/4" PER FT. NOTE #12 GAS PIPING IS A | | | SEPARATE PERMIT. PLANS MUST BE SUBMITED BY THE PLUMBING | | | CONTRACTOR IF NATURAL GAS IS BEING USED. REMOVE NOTE 12 | | | FROM PLANS. | | | 3. RISER DIAGRAM;BATHROOM #2 SHOWER NOT VENTED. FLOOR | | | PLAN SHOWS ALL SHOWERS, RISER DIAGRAM CALLS THEM TUBS | | | PLEASE COORDINATE. BOTH MASTER BATHROOMS ARE ON THE | | | RISER DIAGRAM. ONLY ONE SHOULD BE SHOWN IF EACH UNIT | | | HAS IT'S OWN SEWER. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-12-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-12-26 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-12-26 |
Time |
07:54 |
Sent To |
B |
|
| Notes |
| 2006-12-26 09:01:47 | DENIED; | | | 1. CERTIFICATE OF AUTHORIZATION NUMBER IS REQUIRED TO | | | BE IN THE TITLE BLOCK SEE FAC 61G15-23.002. | | | 2. SANITARY RISER DIAGRAM DOES NOT MATCH FLOOR PLAN. | | | A. MISSING PLUMBING FIXTURE (LAVATORY) | | | B. AUTOMATIC CLOTHES WASHER BRANCH DRAIN TO BE | | | 3" SECTION 406.3 | | | C. ALL BATHROOMS HAVE TUBS NOT SHOWERS. | | | D. PLEASE INDICATE IF EACH UNIT HAS IT'S OWN | | | SEWER CONNECTION. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2007-05-17 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-05-17 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-05-17 |
Time |
08:12 |
Sent To |
I |
|
| Notes |
| 2007-05-17 08:14:16 | ***FAILED*** | | | | | | | | | 1)THE SURVEY SHALL BE UPDATED TO SHOW THE | | | NEWLY-PROPOSED SITE PLAN. | | | | | | 2)LANDSCAPE PLANS SHALL INCLUDE A DATA TABLE, PLANT | | | LIST, ETC. VERIFYING COMPLIANCE WITH ARTICLE XIV OF THE | | | CITY'S ZONING AND LAND DEVELOPMENT REGULATIONS.(I.E. | | | 1 SHADE TREE PER 1600 SQ. FT. OF OPEN SPACE, 1 | | | FLOWERING TREE PER 6400 SQ. FT., 1 SHRUB PER 500 SQ. | | | FT., XERISCAPE TABLE, ETC.) | | | | | | 3)SURVEYS NEED TO MATCH SITE PLANS. | | | | | | 4)REVISED PALNS NEED TO BE REVIEWED AND STAMPED BY | | | HISTORIC PRESERVATION DIVISION. | | | | | | 5)AT LEAST 1 SHADE OF FLOWERING TREE SHALL BE | | | PLANTED FOR EVERY 30 LINEAR FEET ON THE PERIMETER OF | | | THE PROPERTY. | | | | | | 6)A STRIPING DETAIL, IN CONFORMANCE WITH THE CITY'S | | | ZONING AND LAND DEVELOPMENT REGULATIONS, SHALL BE | | | PROVIDED ON THE PLANS. | | | | | | | | | CHRIS HOOPS | | | ZONING TECHNICIAN | | | 561-805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-03-07 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-03-07 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-03-07 |
Time |
15:54 |
Sent To |
I |
|
| Notes |
| 2007-03-07 16:03:54 | ***FAILED*** | | | | | | 1) WHEN PARKING IS PROVIDED OFF OF AN ALLEY, AT LEAST | | | 24 FEET OF BACK-OUT SPACE SHALL BE PROVIDED.AS THE | | | ALLEY IS ONLY 10 FEET IN WIDTH, AN ADDITIONAL 14 FEET | | | SHALL BE PROVIDED ON PRIVATE PROPERTY.THIS SPACE IS | | | IN ADDITION TO, AND BEHIND, THE PARKING SPACES. | | | | | | 2) THE SITE PLAN SHOWS THE SIDEWALK LOCATED ON PRIVATE | | | PROPERTY, WHILE THE SURVEY INDICATES IT IS WITHIN THE | | | RIGHT-OF-WAY.PLEASE ENSURE THAT ALL PLANS ARE | | | CONSISTENT AND PLEASE IDENTIFY THE PROPERTY LINE MORE | | | CLEARLY ON THE SITE PLAN. | | | | | | 3) THE SURVEY SHALL BE UPDATED TO SHOW THE | | | NEWLY-PROPOSED SITE PLAN. | | | | | | 4) PLEASE PROVIDE DIMENSION OF THE SIDE SETBACK. | | | | | | 5) PLEASE PROVIDE THE DIMENSION FROM THE PROPERTY LINE | | | TO THE A/C UNITS.MECHANICAL EQUIPMENT IS ONLY | | | PERMITTED TO EXTEND 4 FEET IN A REQUIRED SETBACK. | | | | | | 6) THE PROJECT INFO TABLE SHOWS 2 PARKING SPACES AT 14 | | | FEET X 18 FEET.....HOWEVER, THESE ARE NOWHERE ON THE | | | SITE PLAN.ADJUST TABLE ACCORDINGLY. | | | | | | 7) SIGNED/SEALED LANDSCAPE PLANS, BY A LICENSED | | | LANDSCAPE ARCHITECT, SHALL BE PROVIDED.LANDSCAPE | | | PLANS SHALL INCLUDE A DATA TABLE, PLANT LIST, ETC. | | | VERIFYING COMPLIANCE WITH ARTICLE XIV OF THE CITY'S | | | ZONING AND LAND DEVELOPMENT REGULATIONS. (I.E. 1 SHADE | | | TREE PER 1600 SQ. FT. OF OPEN SPACE, 1 FLOWERING TREE | | | PER 6400 SQ. FT., 1 SHRUB PER 500 SQ. FT., XERISCAPE | | | TABLE, ETC.) | | | | | | 8) VEHICULAR USE AREAS (I.E. PARKING LOTS) SHALL BE | | | SCREENED FROM ADJACENT RESIDENTIAL DEVELOPMENT BY A | | | WALL OF AT LEAST 36 INCHES IN HEIGHT. | | | | | | 9) A 5 FOOT LANDSCAPE BUFFER SHALL BE PROVIDED BETWEEN | | | VEHICULAR USE AREAS AND THE PUBLIC RIGHT-OF-WAY. | | | HEDGES AND AT LEAST 1 SHADE TREE SHALL BE PLANTED | | | WITHIN THIS BUFFER. | | | | | | 10) AT LEAST 1 SHADE OF FLOWERING TREE SHALL BE PLANTED | | | FOR EVERY 30 LINEAR FEET ON THE PERIMETER OF THE | | | PROPERTY. | | | | | | 11) THE LANDSCAPE PLAN SHALL MATCH THE SITE PLAN. | | | | | | 12) A STRIPING DETAIL, IN CONFORMANCE WITH THE CITY'S | | | ZLDRS, SHALL BE PROVIDED ON THE PLANS. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-12-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-12-21 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-12-21 |
Time |
15:06 |
Sent To |
P |
|
| Notes |
| 2006-12-21 15:19:02 | DENIED, | | | 1. THE PROPOSED DRIVEWAY WITHIN THE FRONT PROPERTY ON | | | 14TH STREET WILL EXCEED THE 1000SQ OR 75% OF LANDSCAPE | | | WITHIN THE FRONT SETBACK. | | | 2. THE ALLOWABLE SQUARE FOOTAGE CAN ONLY BE 12.5SQ FT | | | WIDE. | | | 3. THE DRIVEWAY FROM ALLEY CAN BE RECONSTRUCTED TO | | | ALLOW MORE PARKING SPACE. | | | 4. THE SIDE SETBACK ON HENRIETTA MUST BE 10% OF THE LOT | | | DEPT OF 130FT. (13FT). | | | 5. PLEASE PROVIDE TWO COPIES OF SURVEYS AND SITEPLANS | | | TO REFLECT THE SIDE SETBACK; SEC 94-75, CORNER: 12.5FT; | | | TEN FEET IF LOT IS LESS THAN 60FT WIDE AND SIDE; FIVE | | | FEET MINIMUM. | | | 6. THE PROPOSED A/C UNITS MUST BE SHOWN ON THE TWO | | | COPIES OF SITEPLAN AND SURVEYS. | | | 7. THE PROPOSED A/C UNITS MUST BE BUFFED BY LANDSCAPE. | | | | | | | | | NOTE: SHALL FOLLOW THE LANDSCAPE REQUIREMENTS SEC | | | 94-442(2). | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
|