| 2007-01-25 15:26:19 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2004 |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 |
| | |
| | SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY |
| | |
| | _XX_1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH |
| | THE CLERK OF COURTS BEFORE A PERMIT CAN BE ISSUED, |
| | FS713.13. |
| | |
| | ____2.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN |
| | PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE |
| | DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY |
| | AN ENGINEER. DOCUMENTS PREPARED BY AN ENGINEER AND |
| | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED |
| | ORIGINALS FAC61G15-23.002. |
| | |
| | ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION |
| | APPROVAL. |
| | |
| | _XX_4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE |
| | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN |
| | ANOTHER FORMAT.MOST OF THE INFORMATION IS ON THE |
| | SCHEDULE, BUT SOME IS MISSING (SUCH AS SF OPENING SIZE, |
| | WHICH DETAIL, ETC.). PLEASE CONTACT ME IF YOU HAVE |
| | QUESTIONS OR WOULD LIKE TO DISCUSS. |
| | |
| | ____5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL |
| | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. |
| | |
| | ____6.ON THE PRODUCT APPROVAL, MARK WHICH DETAILS |
| | APPLY TO THIS JOB.PLEASE USE INK RATHER THAN A |
| | HIGHLIGHTER. |
| | |
| | ____7.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC |
| | R310. |
| | |
| | ____8.PROVIDE A FLOOR PLAN SHOWING WHERE THE |
| | SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH |
| | CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 4 |
| | ABOVE. |
| | |
| | _XX_9.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2). |
| | NOTE THAT THE DEFINITION FOR EXPOSURE C HAS CHANGED |
| | EFFECTIVE DECEMBER 8, 2006 FBC1609.4.SEE ATTACHED |
| | AERIAL. |
| | |
| | _XX_ 10.THE SUBSTRATE IS NOTED AS CBS, BUT 9" IS FOR |
| | CONCRETE, NOT HOLLOW BLOCK.ANCHOR SPACING IS NOT |
| | COMPLIANT FOR HOLLOW BLOCK. |
| | |
| | _XX_ 11.THE SCHEDULE WHICH YOU PROVIDED STATES |
| | ASCE7-98; CORRECT REFERENCE IS ASCE7-02, FBC35. |
| | |
| | |
| | |
| | |
| | |
| | |