Plan Review Details - Permit 06120344
Plan Review Stops For Permit 06120344
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-02-05 Cont ID  
Sent By shill Date 2007-02-05 Time 17:20 Rev Time 0.00
Received By shill Date 2007-02-05 Time 17:20 Sent To  
Notes
2007-02-05 17:22:51****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 _XX_4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT.NO ANCHOR SCHEDULE SUBMITTED, AND
 PRODUCT APPROVAL DOES NOT HAVE ANY ANCHORING CIRCLED.
 YOU MAY CIRCLE ANCHORING ON THE PRODUCT APPROVAL IF YOU
 ARE USING A "WORST CASE", FOR BOTH SUBSTRATE AND SPAN.
 NOTE ANCHOR SPACING ON THE FLOOR PLAN AS WELL.
  
 FOR HOLLOW BLOCK, YOU HAVE CIRCLED ANCHOR TYPE AND
 PRESSURE WHICH IS NOT ALLOWED.IT DOES NOT APPEAR THAT
 YOU HAVE ANY SPANS THAT LONG, WHY HAVE YOU CIRCLED
 THIS?THE PURPOSE OF CIRCLING THINGS ON THE PRODUCT
 APPROVAL IS TO DETERMINE CODE COMPLIANCE FOR THAT
 PARTICULAR JOB.IF YOU PLAN TO USE MULTIPLE ANCHOR
 SPACINGS AND DETAILS, THE SCHEDULE IS REQUIRED.PLEASE
 CONTACT ME IF YOU NEED ASSISTANCE.
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-01-25 Cont ID  
Sent By shill Date 2007-01-25 Time 13:20 Rev Time 0.00
Received By shill Date 2007-01-25 Time 13:20 Sent To  
Notes
2007-01-25 13:21:09****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH
 THE CLERK OF COURTS BEFORE A PERMIT CAN BE ISSUED,
 FS713.13.
  
 ____2.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN
 PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE
 DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY
 AN ENGINEER. DOCUMENTS PREPARED BY AN ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED
 ORIGINALS FAC61G15-23.002.
  
 ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 _XX_4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT.
  
 _XX_5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.
  
 ____6.ON THE PRODUCT APPROVAL, MARK WHICH DETAILS
 APPLY TO THIS JOB.PLEASE USE INK RATHER THAN A
 HIGHLIGHTER.
  
 ____7.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC
 R310.
  
 ____8.PROVIDE A FLOOR PLAN SHOWING WHERE THE
 SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH
 CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 4
 ABOVE.
  
 _XX_9.DECLARE EXPOSURE CATEGORY FBC1609.6.2.1(2)
 AND BUILDING HEIGHT.NOTE THAT THE DEFINITION FOR
 EXPOSURE C HAS CHANGED EFFECTIVE DECEMBER 8, 2006
 FBC1609.4.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-02-05 Cont ID  
Sent By adarroug Date 2007-02-05 Time 15:53 Rev Time 0.00
Received By adarroug Date 2007-02-05 Time 15:53 Sent To B
Notes
2007-02-05 15:53:36TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-01-25 Cont ID  
Sent By shill Date 2007-01-25 Time 13:21 Rev Time 0.00
Received By shill Date 2006-12-15 Time 15:59 Sent To  
Notes
2006-12-15 15:59:32TO "MISC" BOX#1


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved