| Plan Review Stops For Permit 06120334 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2006-12-13 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-12-13 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-12-13 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2006-12-13 11:40:32 | UNITY OF TITLE RECEIVED.PERMIT OK. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2007-02-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-04 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2007-02-04 18:36:47 | *** PLANS ARE NOT FOR ELECTRICAL REVIEW, HOWEVER SEE | | | THAT TWO SETS OF PLANS ARE IN FACT PHOTO-COPIES OF | | | SIGNED, AND SELED PLANS WHICH IS STRICLY PROHIBITED | | | UDNER FAC 61G15-23.002 AND FS 471.025. | | | ALL SETS AND ALL DOCUMENTS SHALL CONTAIN ORIGINAL | | | SIGNATURES, DATES AND SEALS. | | | | | | THIS WAS SENT OT THE ENGINEERING REVIEWER. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
P |
Date |
2007-03-01 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-03-01 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-03-01 |
Time |
09:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
F |
Date |
2007-02-08 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-02-08 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-02-08 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2007-02-08 14:53:32 | PROCESSING ON HOLD UNTIL CIVIL PROVIDES THE P.E. SEALED | | | & SIGN DRAWINGS., PER MATHEW HAROLD, P E OF CRAVEN & | | | THOMPSION | | | | | | RASIK CHOKSHI 805-6723 | | 2007-02-05 11:41:36 | ENGINEERING IS TO REVIEW BY 2/, 2/9 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2007-02-02 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-02-02 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-02-02 |
Time |
13:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2006-12-21 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2006-12-21 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2006-12-21 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2006-12-21 14:29:00 | PLEASE PROVIDE FOLLOWING INFO: | | | | | | 1. PLEASE SHOW STANDARDS NOTES OF CITY OF WPB ON | | | DRAWINGSFOR SIDEWALK WIDTH , ITS SLOPE, DRIVEWAY, | | | PARKING, HANDICAP PARKING, PAINTPER CITY CODES ETC.,, | | | MUST MEET PER ADA,,ETC., | | | 2. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE | | | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION | | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | | 3. FIRST FLOOR ELEVATION, CENTER LINE OF ROAD , | | | SIDEWALK ELEVATION MUST MEET FL BLDG CODE, PLEASE SHOW | | | ON THE DRAWINGS. | | | 4. PLEASE PROVIDE A COPY OF SFWMD PERMIT, & GEOTECH | | | REPORT | | | 5.PLEASE SHOW STORM WATER CALCULATIONS, WHAT CRITERIA | | | YOU ASSUMEDFOR RUNOFF CAL.,, LIKE 1" OVER ENTIRE SITE | | | OR2.5"CRITERIA, ?PERVIOUS AREA, LIKE GREEN, | | | LAKES, ETC,IMPERVIOUS AREA CAL., | | | 6. WHAT IS THE SITE AREA, YOU ARE DEVELOPING FOR THIS | | | PROJECT ONLY ? SO, WE CAN CHECK PERVIOUS, IMPERVIOUS | | | CAL. | | | 7. HOW YOU CONNECT TO THE STORM WATER PIPES IN YOUR | | | SITE? ITS DETAILS.PLEASE SHOW ALL STORM WATER PIPES | | | AROUND YOUR SITE SO, WE CANSEE THE BEST PIPE TO | | | CONNECT WITH THE STORM WATERFROM ALL OTHER STORM | | | WATER PIPES. PLEASE SHOW DETAIL OF THE CONTROL | | | STRUCTURES WITH ELEVATIONS, NOTCHES, BLEEDING | | | ELEVATION, ETC DID YOU USE EXFILTRATION TRENCH ? | | | 8.PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND YOUR | | | SITE FOR STORM WATER DRAIN. | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-02-23 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-02-23 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-02-23 |
Time |
10:44 |
Sent To |
ENG |
|
| Notes |
| 2007-02-23 10:46:47 | *****APPROVED***** | | | | | | | | | PLAN SHEET SP-1 WAS STAMPED, INITIALED, AND DATED WITH | | | PROVISO. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-02-13 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-02-13 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-02-13 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2007-02-13 11:13:40 | ******DENIED****** | | | | | | | | | | | | 1.THE COMPLETE ADDRESS OF WHERE THE SCOPE OF WORK | | | WILL BE CONDUCTED SHALL BE IN THE TITLE BLOCK OF EACH | | | SUBMITTED PLAN SHEET. | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2007-01-03 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-01-03 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-01-03 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2007-01-03 15:16:59 | *****PROVISO***** | | | | | | | | | | | | | | | 1.CONSTRUCTION AND/OR DEMOLITION OPERATIONS SHALL NOT | | | HINDER OR INTERFERE WITH EMERGENCY RESPONSE ACCESS TO | | | THE SAID PROPERTY OR VICINITY THEREOF (INCLUDING FIRE | | | LANES). | | | | | | 2.VERIFY THAT THE NUMERICAL ADDRESS FOR THE STRUCTURE | | | IS POSTED BEFORE, DURING, AND AFTER | | | CONSTRUCTION/DEMOLITION OPERATIONS.AS PER WEST PALM | | | BEACH CODE, THE NUMERALS SHALL BE NO LESS THAN 6" IN | | | HEIGHT AND 1" IN WIDTH PLAINLY VISIBLE FROM NORTH | | | AUSTRALIAN AVENUE. | | | | | | 3.SEPARATE PLANS AND PERMIT WILL BE REQUIRED FOR ANY | | | INTERIOR ALTERATION OR REMODEL. | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-02-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-23 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-23 |
Time |
10:15 |
Sent To |
FIRE |
|
| Notes |
| 2007-02-23 10:16:44 | TO "MWILLIAMS' DESK/PER "RBROWN" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-02-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-22 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-22 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2007-02-22 10:16:30 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-01-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-19 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-19 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2007-01-30 10:38:25 | TO "COMM" BD#28 | | 2007-01-19 08:30:51 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-01-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-02 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-15 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2006-12-15 15:58:32 | TO "ENG" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-02-06 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2007-02-06 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2007-02-06 |
Time |
14:22 |
Sent To |
I |
|
| Notes |
| 2007-02-06 14:24:15 | PLANNING AND ZONING : ***PASSED WITH PROVISO*** | | | | | | 1. 2/06/07PASSED W/ PROVISO, SHEET C-7 HC PARKING | | | DETAIL SHALL COMPLY WITH SHEET SP-1 STRIPPING DETAIL. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT. | | | | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | OFFICE: (561) 822-1443 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-01-02 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2007-01-02 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2007-01-02 |
Time |
16:02 |
Sent To |
I |
|
| Notes |
| 2007-01-02 16:12:50 | PLANNING ANDZONING: ****FAILED**** | | | | | | | | | 1.PROVIDE RESPONSE TO COMMENTS IN WRITING. | | | | | | 2.THE SITE PLAN/ENGINEERING PLAN NEED TO MATCH THE | | | APPROVED SITE PLAN BY THE PLANNING AND ZONING | | | DEPARTMENT.THE APPROVAL LETTER IS DATED AUGUST 11, | | | 2006.I HAVE ATTACHED A COPY FOR YOUR REFERENCE. | | | | | | FOR INSTANCE, SHEET C-4 SHOWS THE PARKING ON THE SOUTH | | | EAST CORNER AS A PARKING SPACE.THIS SPACE IS SUPPOSED | | | TO BE DESIGNATED AS A BACK-UP SPACE ONLY. IN ADDITION, | | | ON THE AREA JUST SOUTH OF THE ENTRYWAY TO THE COVERED | | | PARKING, IT SHOWS AS 3 PARKING SPACES.THE APPROVED | | | PLAN SHOWS 4 PARKING SPACES.PLEASE REVISE ALL | | | DOCUMENTION TO MATCH THE APPROVED PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ME. | | | | | | LINDA MIA FRANCO, SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1435 | | | EMAIL: [email protected] |
|
|