| 2007-01-25 08:19:46 | DENIED BY BUILDING |
| | |
| | 1)THE EXISTING "CABANA" APPEARS TO BE A GARAGE THAT |
| | WAS CONVERTED TO LIVING SPACE WITHOUT PERMITS. |
| | |
| | 2) THE STRUCTURE IS LOCATED IN AN A5 FLOOD ZONE, WHICH |
| | REQUIRES THE FINISH FLOOR TO HAVE A BASE FLOOD |
| | ELEVATION OF 7' 6". SPECIFY THE ELEVATION OF FINISH |
| | FLOOR OF THE CABANA. SUBMIT AN ELEVATION CERTIFICATE |
| | FOR THIS AREA. |
| | |
| | 3) THE ENCLOSING OF THE GARAGE IS ADDING ADDITIONAL |
| | LIVING SPACE TO THE EXISTING RESIDENCE. THEREFORE, THE |
| | PLANS ARE REQUIRED TO BE REVIEWED PALM BEACH COUNTY TO |
| | DETERMINE IF IMPACT FEES ARE OWED. THE PLANS MUST BE |
| | STAMPED BY THEM AND A COPY OF THE RECIEPT SUBMITTED |
| | BEFORE THE PERMIT IS ISSUED. |
| | |
| | 4)WPB ADMIN CODE 106.3* PRODUCT |
| | APPROVALS. THOSE PRODUCT WHICH ARE |
| | REGULATED BY DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| | FOR JURISDICTIONAL APPROVAL. |
| | |
| | 5) A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 6) SUBMIT ENERGY CALCULATIONS FOR THE ENCLOSED GARAGE |
| | PER FBC CHAPTER 13. |
| | |
| | 7) SPECIFY THE CEILING AND WALL INSULATION ON THE |
| | PLANS. |
| | |
| | 8) WOOD SIDING, SHEATHING AND WALL FRAMING ON THE |
| | EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN |
| | 6 INCHES SHALL COMPLY WITH SECTION R319 PROTECTION |
| | AGAINST DECAY. |
| | |
| | 9)PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. |
| | |
| | 10)WPB ADMIN CODE 106.3* PRODUCT |
| | APPROVALS. THOSE PRODUCT WHICH ARE |
| | REGULATED BY DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| | FOR JURISDICTIONAL APPROVAL. |
| | |
| | 11) SHOW COMPLIANCE WITH SECTION 704 INSPECTION FOR |
| | TERMITES. |
| | IN ORDER TO PROVIDE FOR INSPECTION FOR TERMITE |
| | INFESTATION, CLEARANCE BETWEEN EXTERIOR WALL COVERINGS |
| | AND FINAL EARTH GRADE ON THE EXTERIOR OF A BUILDING |
| | SHALL NOT BE LESS THAN 6 INCHES (152 MM). |
| | EXCEPTIONS: |
| | 1.PAINT OR DECORATIVE CEMENTITIOUS FINISH LESS |
| | THAN 5 / 8 INCH (17.1 MM) THICK ADHERED DIRECTLY TO THE |
| | MASONRY FOUNDATION SIDEWALL. |
| | 2.ACCESS OR VEHICLE RAMPS WHICH RISE TO THE |
| | INTERIOR FINISH FLOOR ELEVATION FOR THE WIDTH OF SUCH |
| | RAMPS ONLY. |
| | 3.A 4-INCH (102 MM) INSPECTION SPACE ABOVE PATIO |
| | AND GARAGE SLABS AND ENTRY AREAS. |
| | 4.IF THE PATIO HAS BEEN SOIL TREATED FOR TERMITES, |
| | THE FINISH ELEVATION MAY MATCH THE BUILDING INTERIOR |
| | FINISH FLOOR ELEVATIONS ON MASONRY CONSTRUCTION ONLY. |
| | 5.MASONRY VENEERS. |
| | |
| | 12) SHOW COMPLIANCE WITH R401.3 DRAINAGE . |
| | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER |
| | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS |
| | TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO |
| | DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE |
| | GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM |
| | OF 6 INCHES (152 MM) WITHIN THE FIRST 10 FEET (3048 |
| | MM). |
| | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER |
| | PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL |
| | WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE |
| | PROVIDED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. |
| | |
| | 13) SHOW COMPLIANCE WITH R404.1.6 HEIGHT ABOVE FINISHED |
| | GRADE. |
| | CONCRETE AND MASONRY FOUNDATION WALLS SHALL EXTEND |
| | ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION AT |
| | ALL POINTS A MINIMUM OF 4 INCHES (102 MM) WHERE MASONRY |
| | VENEER IS USED AND A MINIMUM OF 6 INCHES (152 MM) |
| | ELSEWHERE. |
| | |
| | 14) SUBMIT FLORIDA PROUCT APPROVAL NUMBERS FOR THE USP |
| | CONNECTORS. |
| | |
| | 15) FENCES AND WALLS REQUIRE SEPARATE PERMITS. NOTE: |
| | THE LETTER SUBMITTED FOR THE MASORY PRIVACY WALL MUST |
| | SPECIFY A 140 MPH WINDSPEED. |
| | |
| | |