| Plan Review Stops For Permit 06120303 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-12-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-12-19 |
Time |
14:53 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2006-12-19 |
Time |
14:53 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-12-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-12-12 |
Time |
15:25 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2006-12-12 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2006-12-12 16:00:30 | BUILDING REVIEW CHECKLIST: | | | 1-COPY OF CONTRACTOR'S PROPOSAL TO THE OWNERINCLUDES | | | 1/4" INSULATION. SELECTED APPROVED ASSEMBLYON NOA | | | #03-0501.02 IS FOR A NON-INSULATED ASSEMBLY. CLARIFY IF | | | INSTALLING INSULATEDOR NON-INSULATED SYSTEM AND | | | PROVIDE CORRESPONDING INFORMATION. | | | | | | 2- FROM SELECTED ASSEMBLY SPECIFY FASTENING OPTION AS | | | REQUIRED BY CITY POLICY FOR RE-ROOFING PERMITS TO | | | VERIFY MAXIMUM DESIGN PRESSURES. SEE ATTACHED COPY OF | | | CITY POLICY. | | | | | | 3- PROVIDE RAS 117 CALCULATIONSAS REQUIRED BY GENERAL | | | LIMITATION #7 FOR ENHANCED FASTENING AT PERIMETER AND | | | CORNER AREAS. SEE TABLE 1609.6B FOR REQUIRED DESIGN | | | PRESSURES. SEE GENERAL LIMITATION #7 ON LAST PAGE OF | | | NOA TO SEE REQUIRED INFORMATION TO BE SUBMITTED. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
|