| Plan Review Stops For Permit 06120209 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2008-10-22 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-10-22 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-10-22 |
Time |
06:51 |
Sent To |
PC |
|
| Notes |
| 2008-10-22 07:48:37 | BUILDING PLAN REVIEW | | | PERMIT: 06120209 | | | ADD: 1325 9TH ST. | | | CONT: OWNER | | | TEL: (561)805-7240 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: ENERGY CALCS SUBMITTAL. | | | ACTION: DENIED | | | | | | 1) THE ENERGY CALCULATION SHEETS SUBMITTED REFERENCE | | | THE 2001 FBC. ALLL PLANS, SPECIFICATIONS, REPORTS AND | | | OTHER INFORMATION SUBMITTED AFTER OCTOBER, 1, 2004 | | | SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE. | | | | | | 2) FBC 13-103.1.2 ENERGY CODE COMPLIANCE FORMS SHALL BE | | | SIGNED BY THE BUILDING OWNER, THE | | | OWNER'S ARCHETECT OR OTHER AUTHORIZED AGENT LEGALLY | | | DESIGNATED BY THE OWNER. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-08-05 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-08-05 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-08-05 |
Time |
10:53 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-11-28 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-11-28 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-11-14 |
Time |
17:15 |
Sent To |
M |
|
| Notes |
| 2007-11-15 15:48:47 | BUILDING PLAN REVIEW | | | PERMIT:06120209 | | | ADD:1325 9TH STREET | | | CONT:JUSTINA A. MCCRAY | | | TEL: (561)805-7255 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 3RD | | | ACTION: DENIED | | | | | | 1)OK | | | 2)OK | | | 3)OK | | | 4)OK | | | 5)OK | | | | | | 6)NOTED: INDICATE WHICH ITEMS OR SYSTEMS WILL BE USED | | | FROM EACH PRODUCT APPROVAL, INCLUDING THE FASTENER | | | SPACING OR THE STORM PANELS. | | | | | | 7)OK | | | 8)OK | | | 9)OK | | | 10)OK | | | 11) OK | | | | | | NEW*************** | | | | | | 12)R802.1.6TRUSS DESIGN DRAWINGS PREPARED IN | | | CONFORMANCE WITH SEC. R802.1.6.1 SHALL BE PROVIDED TO | | | THE BUILDING OFFICIAL AND APPROVED PRIOR TO | | | INSTALLATION. | | | | | | A) INDICATE THE TYPE OF INSULATION AT THE EXTERIOR | | | WALLS. THE DRAWINGS SHOW R-19 INSULATION FOR THE ATTIC | | | AND THE ENERGY CALCULATIONS SHOW R-30 WHIC IS IT? | | | CLARIFY. | | | B)THE DRAWINGS CALL FOR 2500PSI CONCRETE FOOTINGS AND | | | THE SOIL REPORT CALLS FOR 200PSI. CLARIFY. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-07-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-07-14 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-07-14 |
Time |
05:06 |
Sent To |
PC |
|
| Notes |
| 2007-07-14 08:59:57 | BUILDING PLAN REVIEW | | | PERMIT:06120209 | | | ADD:1325 9TH STREET | | | CONT:JUSTINA A. MCCRAY | | | TEL: (561)805-7255 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW1ST | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2)OK | | | | | | 3)OK | | | | | | 4)OK | | | | | | 5)OK | | | | | | 6)106.3.3* PRODUCT APPROVALS- 2004 | | | THOSE PRODUCTS THAT ARE RGULATED BY DCA | | | RULE 9B-72 SHALL BE REVIEWED AND | | | APPROVED IN WRITTING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. PROVIDE THE PRODUCT APPROVALS | | | FOR THE HURRICANE PROTECTION OF THE GLASS BLOCKS. | | | | | | 7)OK | | | | | | 8)OK | | | | | | 9)OK | | | | | | 10)OK | | | | | | 11) OK | | | | | | NEW*************** | | | | | | 12)R802.1.6TRUSS DESIGN DRAWINGS PREPARED IN | | | CONFORMANCE WITH SEC. R802.1.6.1 SHALL BE PROVIDED TO | | | THE BUILDING OFFICIAL AND APPROVED PRIOR TO | | | INSTALLATION. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-02-08 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-02-08 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-02-08 |
Time |
08:42 |
Sent To |
PC |
|
| Notes |
| 2007-02-08 09:44:29 | BUILDING PLAN REVIEW | | | PERMIT:06120209 | | | ADD:1325 9TH STREET | | | CONT:JUSTINA A. MCCRAY | | | TEL: (561)805-7255 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW1ST | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3)THE EMERGENCY EGRESS WINDOWS SHALL REFER TO | | | SECTION R310 OF THE 2004 RESIDENTIAL BUILDING CODE OR | | | THE 2004 FBC. NOT THE 2001 FBC. | | | | | | 4)WPB AMENDMENTS 108.3*THE VALUE IS TO LOW. IF IN | | | THE OPINION OF THE BUILDING OFFICIAL, THE CLAIMED | | | VALUATION OF BUILDING, ALTERATION, STRUCTURE, | | | ELECTRICAL, GAS, MECHANICAL OR PLUMBING SYSTEMS APPEARS | | | TO BE UNDERESTIMATED ON THE APPLICATION, THE PERMIT | | | SHALL BE DENIED. FOR PERMITTING PURPOSES, VALUATION OF | | | BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE | | | TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, MECHNICAL, | | | INTERIOR FINISH, NORMAL SITE WORK, ARCHITECTURAL AND | | | DESIGN FEES EXCLUDING LAND.OUR VALUATION REFERENCE IS | | | ICC (BVD) MARSHALL-SWIFT AND MEANS COST ANALYSIS | | | SERVICES. | | | | | | 5)R807.1 ATTIC ACCESS. IN BUILDINGS WITH COMBUSTIBLE | | | CEILING OR ROOF CONSTRUCTION, AN ATTIC ACCESS OPENING | | | SHALL BE PROVIDED TO ATTIC AREAS THAT EXCEED 30 SQUARE | | | FEET AND HAVE A VERTICAL HEIGHT OF 30 INCHES OR | | | GREATER. | | | THE ROUGH-FRAME OPENING SHALL NOT BE LESS THAN 22 | | | INCHES BY 30 INCHES AND SHALL BE LOCATED IN A HALLWAY | | | OR OTHER REDAILY ACCESSIBLE LOCATION. A 30-INCH MINIMUM | | | UNOBSTRUCTED HEADROOM IN THE ATTIC SPACE SHALL BE | | | PROVIDED AT SOME POINT ABOVE THE ACCESS OPENING. SEE | | | SECTION M 1305.1.3 FOR ACCESS REQUIREMENTS WHERE | | | MECHANICAL EQUIPMENT IS LOCATED IN ATTICS. | | | | | | 6)106.3.3* PRODUCT APPROVALS- 2004 | | | THOSE PRODUCTS THAT ARE RGULATED BY DCA | | | RULE 9B-72 SHALL BE REVIEWED AND | | | APPROVED IN WRITTING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. PROVIDE THE PRODUCT APPROVALS | | | FOR THE GLASS BLOCKS. | | | | | | 7)M1506.2EXHAUST AIR FROM BATHROOMS AND TIOLET | | | ROOMS SHALL NOT BE RECIRCULATED WITHIN A RESIDENCE OR | | | TO ANOTHER DWELLING UNIT. MECHANICAL EXHAUST CAPACITY | | | FOR BATHROOMS AND TOILET ROOMS SHALL BE NO LESS THAN 50 | | | CFM INTERMITTENT OR 20 CFM CONTINOUS. | | | | | | 8)R308.4 (5)GLAZING IN DOORS AND ENCLOSURES FOR HOT | | | TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND | | | SHOWERS. GLAZING IN ANY PART OF A BUILDING WALL | | | ENCLOSING THESE XOMPARTMENTS WHERE THE BOTTOM EXPOSED | | | EDGE OF THE GLAZING IS LESS THAN 60 INCHES MEASURED | | | VERTICALLY ABOVE THE STANDING OR WALKING SURFACE. | | | | | | 9)WPB AMENDMENTS 106.1.3*THE BUILDING OFFICIAL MAY | | | ESTABLISH THROUGH DEPARTMENTAL POLICY, STANDARDS FOR | | | PLANS AND SPECIFICATIONS, IN ORDER TO PROVIDE | | | COMFORMITY TO ITS RECORD RETENTION PROGRAM,THIS | | | POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, SHAPE, | | | CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO RECORDS | | | MANAGEMENT. THE SEAL ON THE DRAWINGS ARE ILLEGIBLE. | | | 61G15-23.002A PROFESSIONAL ENGINER SHALL SIGN HIS | | | NAME AND AFFIX HIS SEAL TO ALL PLANS, SEPCIFICATIONS, | | | REPORTS, FINAL BID COCUMENTS OR OTHER DOCUMENTS | | | PREPARED OR ISSUED BY SAID REGISTRANT AND BEING FILED | | | FOR PUBLIC RECORD. | | | | | | 10)PROVIDE AN INTERIOR ELEVATION SHOWING ALL | | | DIMENTIONS OF THE LIVING SPACE CEILING INCLUDED. HOW | | | WILL THE EXISTING STRUCTURE BE SUPPORTED WHEN THE | | | EXTERIOR WALL AT THE KITCHEN AREA IS REMOVED. SHOW IN | | | DETAIL HOW THIS AREA WILL BE SUPPORTED. | | | | | | 11) | | | ) 110.2* W. P. B. ADMINISTRATIVE | | | CODE, INFORMATION THAT IS REQUIRED FOR | | | RECORD KEEPING & FOR CERTIFICATE OF | | | OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6, TABLE 601. | | | ) NUMBER OF FLOORS | | | ) NUMBER OF ROOMS | | | ) NUMBER OF BEDROOMS | | | ) SQ. FT. LIV SPACE/ FL | | | ) SQ. FT. FOOTPRINT | | | ) SQ. FT. UNDER ROOF (TOTAL) | | | ) FLOOD ZONE | | | ) FLOOD ELEVATION | | | )L.O.M.R. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-08-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-08-05 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-08-05 |
Time |
12:19 |
Sent To |
B |
|
| Notes |
| 2008-08-05 12:19:46 | | | | | | | MOVED INTERIOR PANEL./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-11-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-11-08 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-11-08 |
Time |
12:00 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-07-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-07-03 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-07-03 |
Time |
07:28 |
Sent To |
P |
|
| Notes |
| 2007-07-03 08:20:08 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1} THE DISCONNECT LOCATION ON THE RISER IS INCORRECT AN | | | DISCONNECTS NOTHING. PLEASE REDRAW AND INDICATE THE | | | CONDUIT AND WIRE SIZES. SEE 250.122 AND INSTALL THE | | | EQUIPMENT GROUND PER SAME (AFTER THE DISCONNECT AND RUN | | | TO PANEL). | | | | | | 2} THERE IS ONLY ONE A/C SYSTEM ON THE PANEL SCHEDULE, | | | TWO IN THE CALCULATIONS. PLEASE CORRELATE. | | | | | | 3} THE ELECTRICAL PANEL LOCATION IN THE KITCHEN WOULD | | | NOT COMPLY WITH THE 3' CLEARANCE REQUIREMENT OF 110.26, | | | WITH RESPECT TO THE PENINSULAR. | | | | | | 4}BATH CIRCUIT REQUIRED TO HAVE A 20 AMP CIRCUIT PER | | | 210.11(C) (3), INCLUDE IN THE PANEL SCHEDULE. | | | | | | 5} RECEPTACLE SPACING MUST COMPLY WITH 210.52(A) (1) | | | AND 210.52 (A) (2), SEE DINING ROOM AND NEW BEDROOM. | | | NOTE THE DINING ROOM MUST BE ON A SMALL APPLIANCE | | | CIRCUIT PER 210.52(B)(1). | | | | | | 6} THE ISLAND AND PENINSULAR RECEPTACLES MUST BE GFCI | | | PROTECTED PER 210.8(A)(6), INDICATE ON PLAN.. | | | | | | 7}A RECEPTACLE IS REQUIRED FOR THE SERVICING OF THE | | | CONDENSING UNITS PER 210.63. NONE IS INDICATED ON THE | | | PLAN. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-12-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-12-21 |
Time |
11:11 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-12-21 |
Time |
10:35 |
Sent To |
P |
|
| Notes |
| 2006-12-21 11:10:59 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1} SHOW THE PHYSICAL LOCATION OF ALL SERVICE EQUIPMENT | | | ON THE PLAN. 215.5. PER THE RISER DIAGRAM IT WOULD | | | APPEAR THAT A 200 AMP DISCONNECT WOULD BE REQUIRED AT | | | THE METER PER 230.70 (A) (1). | | | | | | 2} PER 110.9 AND 110.10: OBTAIN THE | | | AVAILABLE FAULT CURRENT AT THE UTILITY | | | AND CALCULATE THE SAME AT THE EQUIPMENT. | | | INDICATE THE AIC RATING FOR THE | | | EQUIPMENT IS EQUAL TO OR GREATER THAN | | | THE AVAILABLE FAULT. | | | | | | 3} PLEASE PROVIDE A PANEL SCHEDULE SO THAT | | | BRANCH/FEEDER CIRCUIT CONDUCTOR AND OVER CURRENT | | | PROTECTION COMPLIANCE MAY BE REVIEWED PER 106.3.5.4 FBC | | | AS AMENDED. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2008-10-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-10-23 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-10-23 |
Time |
16:03 |
Sent To |
B |
|
| Notes |
| 2008-10-23 16:04:04 | TO "MJACOBS" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2008-10-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-20 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-20 |
Time |
08:37 |
Sent To |
B |
|
| Notes |
| 2008-10-20 08:37:47 | TO "MJACOBS" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-08-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-14 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-14 |
Time |
11:21 |
Sent To |
M |
|
| Notes |
| 2008-08-14 11:22:18 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-07-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-31 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-31 |
Time |
10:57 |
Sent To |
M |
|
| Notes |
| 2008-07-31 10:57:44 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-12-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-04 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-04 |
Time |
11:50 |
Sent To |
M |
|
| Notes |
| 2007-12-04 11:50:58 | TO "M" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-11-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-06 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-06 |
Time |
09:11 |
Sent To |
Z |
|
| Notes |
| 2007-11-06 09:12:22 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-06-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-26 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-26 |
Time |
11:33 |
Sent To |
Z |
|
| Notes |
| 2007-06-26 11:34:23 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-12-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-18 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-18 |
Time |
13:05 |
Sent To |
E |
|
| Notes |
| 2006-12-18 13:06:01 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2007-02-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-07 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2006-12-07 15:11:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
9 |
Status |
P |
Date |
2008-10-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-10-29 |
Time |
13:47 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2008-10-29 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2008-10-29 13:48:08 | REVISION TO ENERGY CAL'S. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
P |
Date |
2008-09-08 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-09-08 |
Time |
11:58 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2008-09-08 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2008-09-08 11:59:37 | RE-STAMP |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2008-08-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-14 |
Time |
14:22 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-08-14 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2008-08-14 14:23:03 | REVISION TO MECH. PLAN AND COOLING LOAD CAL'S. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2008-08-04 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-04 |
Time |
13:51 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-08-04 |
Time |
13:50 |
Sent To |
B |
|
| Notes |
| 2008-08-04 13:58:53 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | REVISION TO MECHANICAL PLAN. | | | *** DENIED *** | | | | | | 1) THE COOLING LOAD CALCULATIONS ON FILE ARE CALLING | | | FOR 20,232 TOTAL COOLING BTU'S, THE REVISED MECHANICAL | | | PLAN EQUIPMENT SCHEDULE SHOWS 29,200 TOTAL COOLING | | | BTU'S, THE PLANS CAN ONLY CALL FOR 15% MORE TOTAL | | | COOLING BTU'S THAN THE COOLING LOAD CALCULATIONS, PER | | | 2004 FBC 13-607.1.ABC.1.1. A 2.5 TON A/C SYSTEM IS TO | | | LARGE PER THE COOLING LOAD CAL'S. PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-12-04 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-12-04 |
Time |
14:00 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-12-04 |
Time |
14:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2007-11-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-28 |
Time |
10:42 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-11-28 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2007-11-28 11:21:51 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) INFORMATION ON MECHANICAL PLAN SHOW TOTAL COOLING AT | | | 22,600 BTU'S FOR THIS 2.5 TON SYSTEM IS INCORRECT. SEE | | | ATTACHED ARI CERTIFICATE FOR THAT SYSTEM SHOWS THE | | | TOTAL COOLING IS 27,200 BTU'S. AS NOTED IN LAST REVIEW | | | 11-13-07 NOTE #1. THE COOLING LOAD CALCULATIONS ARE | | | CALLING FOR 20,232 TOTAL BTU'S AND THE CORRECT TOTAL | | | BTU,S FOR THE SYSTEM LISTED ON THE MECHANICAL PLAN IS | | | 27,200 (SEE ATTACHED ARI LISTING). THE MECHANICAL PLANS | | | CAN ONLY CALL FOR 15% MORE TOTAL BTU'S THAN THE COOLING | | | LOAD CAL'S, SEE FBC 13-607.1.ABC.1.1. PLEASE CORRECT. | | | | | | 2) TWO DIFFERENT SIZE MECHANICAL PLANS WERE SUBMITTED, | | | PLEASE INDICATE WHICH PLAN IS FOR REFERENCE AND NOT TO | | | BE USED. | | | | | | 3) BE ADVISED ONE COPY OF THE COOLING LOAD | | | CALCULATIONS, ENERGY CAL'S. AND MECHANICAL PLANS HAVE | | | BEEN RETAINED FOR OUR RECORDS, PLEASE PROVIDE TWO | | | COPIES WHEN RE-SUBMITTING. | | | | | | 4) SEE ATTACHED NOTICE FS 553.80 (2) (B) REGARDING FOUR | | | TIMES THE FEE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-11-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-13 |
Time |
09:01 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-11-13 |
Time |
09:01 |
Sent To |
B |
|
| Notes |
| 2007-11-13 09:09:36 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) THE COOLING LOAD CALCULATIONS ARE CALLING FOR 20,232 | | | TOTAL BTU'S AND THE TOTAL BTU,S LISTED ON THE | | | MECHANICAL PLAN IS 27,200 (SEE ATTACHED ARI LISTING). | | | THE MECHANICAL PLANS CAN ONLY CALL FOR 15% MORE TOTAL | | | BTU'S THAN THE COOLING LOAD CAL'S, SEE FBC | | | 13-607.1.ABC.1.1. PLEASE CORRECT. | | | | | | 2) THE MECHANICAL PLANS NEED THE PRINTED NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN, AND | | | CONTRACTOR INFORMATION IF APPLICABLE ON THEM, SEE | | | W.P.B. AMEND. 106.1.3. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-07-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-13 |
Time |
10:54 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-07-13 |
Time |
10:54 |
Sent To |
B |
|
| Notes |
| 2007-07-13 11:04:23 | *** DENIED *** | | | | | | 1) AS NOTED IN LAST REVIEW 12-22-07 NOTE #1. PLEASE | | | SHOW AN A/C EQUIPMENT LISTING ON THE MECHANICAL PLANS. | | | | | | 2) TWO DIFFERENT SETS OF THE COOLING LOAD CALCULATIONS | | | HAVE BEEN SUBMITTED, PLEASE REMOVE ONE SET. | | | | | | 3)SEE ATTACHED NOTICE FS 553.80 (2) (B) REGARDING | | | FOUR TIMES THE FEE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-12-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-12-22 |
Time |
16:39 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-12-22 |
Time |
16:39 |
Sent To |
B |
|
| Notes |
| 2006-12-22 16:42:18 | *** DENIED *** | | | 1) PLEASE SHOW AN A/C EQUIPMENT LISTING ON THE | | | MECHANICAL PLANS. | | | | | | 2) ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | SHALL BEAR THE PRINTED NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE | | | FOR THE DESIGN. PER FBC 104.2.1 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-11-13 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-11-13 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-11-13 |
Time |
07:50 |
Sent To |
M |
|
| Notes |
| 2007-11-13 07:55:05 | ****************PROVISO**************** | | | (A) 708.3.5 BUILDING DRAIN AND BUILDING SEWER | | | JUNCTION. THERE SHALL BE A TWO-WAY CLEANOUT NEAR THE | | | JUNCTION OF THE BUILDING DRAIN AND THE BUILDING SEWER. | | | | | | (B) 708.7 MINIMUM SIZE. CLEANOUTS SHALL BE THE SAME | | | NOMINAL SIZE AS THE PIPE. | | | **CLEANOUT FOR THE WASHING MACHINE SHALL BE 3 INCH. | | | THEY SERVE UP TO 4 INCHES (102MM) | | | | | | (C) 708.9 ACCESS. ACCESS SHALL BE PROVIDED TO ALL | | | CLEANOUTS. | | | **CLEANOUT FOR THE WASHING MACHINE SHALL BE 4' A.F.F. | | | | | | (D) DISHWASHER DRAIN PER FLOOR PLAN LAYOUT IS LOCATED | | | AT THE OTHER END OF TRIPLE COMPARTMENT KITCHEN SINK. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-07-13 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-07-13 |
Time |
09:48 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-07-13 |
Time |
09:48 |
Sent To |
M |
|
| Notes |
| 2007-07-13 09:51:16 | DENIED 2ND TIME | | | REFERENCE: | | | ** FBC-2004 PLUMBING. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | 1. SHEET A1: THE RESUBMITTED SANITARY RISER DIAGRAM | | | STILL DOES NOT REFLECT THE FLOOR PLAN ON SHEET A2. | | | PLEASE REFERENCE THE FOLLOWING RED LINE CORRECTIONS ON | | | SHEET A1 SANITARY RISER DIAGRAM THAT REFLECTS THE FLOOR | | | PLAN AND CORRECT THEM FOR THE NEXT RESUBMITTAL. | | | | | | A} LAV IN MASTER BATH IS BEING INDICATED IN THE | | | WRONG PLACE. | | | B} LAV IN TUB BATH IS BEING INDICATED IN THE | | | WRONG PLACE. | | | C} WASHING MACHINE IS BEING INDICATED IN THE | | | WRONG PLACE. | | | | | | ********IMPORTANT INFORMATION******** | | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | | TRANSMITTAL LETTER INDICATING HOW EACH | | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. | | | NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-12-22 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-12-22 |
Time |
14:04 |
Rev Time |
1.25 |
| Received By |
mperson |
Date |
2006-12-22 |
Time |
14:03 |
Sent To |
M |
|
| Notes |
| 2006-12-22 14:31:58 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING | | | PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. SHEET A2 SANITARY RISER DIAGRAM DOES NOT REFLECT | | | THE FLOOR PLAN, PLEASE REFERENCE THE ATTACHED CORRECTED | | | SANITARY RISER DIAGRAM TO THE PLUMBING COMMENTS | | | REFLECTING THE FLOOR PLAN THAT IS CODE COMPLIANT. | | | | | | 2. PER FBC-2004 PLUMBING THE FOLLOWING CORRECTIONS ARE | | | REQUIRED FOR THE WASHING MACHINE. | | | (A) 406.3 WASTE CONNECTIONS.THE TRAP AND | | | FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES | | | WASHER SHALL BE A MINIMUM OF 2 INCHES | | | (51MM) IN DIAMETER. THE AUTOMATIC | | | CLOTHES WASHER FIXTURE DRAIN SHALL | | | CONNECT TO A BRANCH DRAIN OR DRAINAGE | | | STACK A MINIMUM OF 3 INCHES (76MM) IN | | | DIAMETER. | | | (B) 802.4 STANDPIPES.STANDPIPES SHALL BE INDIVIDUALLY | | | TRAPPED. STANDPIPES SHALL | | | EXTEND A MINIMUM OF 18 INCHES (457MM) | | | AND A MAXIMUM OF 42 INCHES (1066MM) | | | ABOVE THE TRAP WEIR. ACCESS SHALL BE | | | PROVIDED TO ALL STANDPIPES AND DRAINS | | | FOR RODDING. PLEASE INDICATE THE STANPIPE ON THE | | | RESUBMITTED DRAWINGS. | | | (C) 708.9 ACCESS. ACCESS SHALL BE PROVIDED TO ALL | | | CLEANOUTS, ON RESUBMITTED DRAWINGS PLEASE INDICATE | | | CLEANOUT FOR WASHING MACHINE AT 4 FEET ABOVE FINNISH | | | FLOOR (4' AFF). | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-11-08 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-11-08 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-11-08 |
Time |
08:12 |
Sent To |
E |
|
| Notes |
| 2007-11-08 08:13:23 | ***APPROVED - RESUB #2*** | | | | | | | | | | | | | | | SENT TO "E" - BT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-06-26 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-06-26 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-06-26 |
Time |
16:00 |
Sent To |
E |
|
| Notes |
| 2007-06-26 16:03:09 | ***FAILED*** | | | | | | | | | 1)PREVIOUS COMMENT NOT ADDRESSED.STILL NEED TO SHOW | | | THE SETBACK DIMENSION FROM PROPOSED A/C UNIT TO | | | PROPERTY LINE. (NOTE: MAY NOT BE CLOSER THAN 1' TO THAT | | | PARTICULAR SIDE PROPERTY LINE). | | | | | | | | | CHRIS HOOPS | | | ZONING TECHNICIAN | | | 561-805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-12-16 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-12-16 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-12-16 |
Time |
10:35 |
Sent To |
I |
|
| Notes |
| 2006-12-16 10:39:30 | DENIED, | | | 1. SITEPLANS SUBMITTED DOES NOT SHOW THE LOCATION OF | | | A/C UNIT, PLEASE SHOW THE A/C UNIT ON THE TWO COPIES OF | | | SITEPLANS WITH SETBACKS. | | | NOTE: THE PROPOSED A/C SHALL NOT BE CLOSER THAN 6FT | | | FROM SIDE PROPERTY LINE. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|