| Plan Review Stops For Permit 06120094 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2008-05-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-05-08 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-05-08 |
Time |
14:40 |
Sent To |
PC |
|
| Notes |
| 2008-05-08 15:00:08 | BUILDING SUBMITTAL CHECKLIST. | | | | | | 1- PROVIDE PRODUCT APPROVAL FOR ENTRY DOOR UNDER A | | | SEPARATE PERMIT AS AGREED WITH OWNER (ELIZABETH | | | DEWOODY)ON PROVISO DATED 4-20-07.PROVISO ALLOWED | | | TO ISSUE THE HOUSE PERMIT WITHOUT HAVING TO PAY | | | RE-SUBMITTAL FEES.PRODUCT APPROVAL SUBMITTED AT THAT | | | TIME WAS NOT GOOD FOR 3'-6" X 8'-0" ENTRY DOOR AS SHOWN | | | ON PLANS. | | | | | | ***NOTE: WHEN APPLYING FOR ENTRY DOOR SEPARATE | | | PERMIT, PLEASE MAKE SURE THE FOLLOWING IS PROVIDED: | | | 2- PRODUCT APPROVAL SUBMITTED NOW STILLIS NOT GOOD | | | FOR SIZE OF DOOR SHOWN ON PLANS. NEED TOPROVIDE | | | PRODUCT APPROVAL FOR SIZE AND TYPE OF DOOR AS SHOWN ON | | | PLANS. | | | | | | 3- PRODUCT APPROVAL NEEDS TO BE REVIEWED AND APPROVED | | | IN WRITING (NOT SIGNING AND SEALING)BY THE DESIGNER | | | OF RECORD AS REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS | | | TO FBC 2004 PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2008-04-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-04-01 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-04-01 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2008-04-01 10:10:28 | PLANS RE-STAMPING. | | | | | | REMAINDER: PROVIDE INFORMATION REQUESTED ON PROVISO | | | DATED 4-20-07 TO AVOID UNNECESSARY DELAYS. SEE ATTACHED | | | COPY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2008-03-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-03-20 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-03-20 |
Time |
16:54 |
Sent To |
E |
|
| Notes |
| 2008-03-20 17:00:12 | PLANS RE-STAMPING BUILDING REVIEW CHECKLIST. | | | | | | 1- PLANS NEED TOHAVE ARCHITECT'S ORIGINAL SIGNATURE, | | | NOT RUBBER STAMP.CHAPTER 481 FLORIDA STATUTE AND SEC. | | | 61G1-16.003 FLORIDA ADMINISTRATIVE CODE. | | | | | | 2- REMAINDER: PROVIDE ALLITEMS REQUESTED ON PROVISO | | | TO AVOID UNNECESSARY DELAYS. SEE ATTACHED PROVISO | | | COPY. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-06-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-06-05 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-06-05 |
Time |
10:04 |
Sent To |
Z |
|
| Notes |
| 2007-06-05 10:52:25 | BUILDING REVISION OK.NEED TO PROVIDE INFORMATION | | | REQUIRED ON PROVISO DATED 4/20/07. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-04-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-04-20 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-04-20 |
Time |
07:37 |
Sent To |
PC |
|
| Notes |
| 2007-04-20 13:40:37 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1- PROVIDE COMPLETE INFORMATION FOR ENTRY DOOR PRODUCT | | | APPROVAL UNDER A SEPARATE PERMIT AS AGREED WITH THE | | | OWNER (MRS. ELIZABETH DEWOODY) ON PHONE CONVERSATION. | | | | | | 2- SURVEY WAS REVISED TO READ FLOOD ZONE B. CORRECT | | | FLOOD ZONE IS A5. REVISE AS REQUIRED. | | | | | | 3- SOIL TEST REPORT NEEDS TO HAVE FIRM'S CERTIFICATE OF | | | AUTHORIZATION NUMBER AS REQUIRED BYSEC. 61G15-23.002 | | | OF FLORIDA ADMINISTRATIVE CODE. | | | | | | 4- ALL ARCHITECT'S LETTERS TO HAVE ARCHITECT'S ORIGINAL | | | SEAL, SIGNATURE AND DATE AS REQUIRED BY CHAPTER 481 | | | FLORIDA STATUTES. COPIES ARE NOT ALLOWED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-04-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-04-10 |
Time |
18:58 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-04-10 |
Time |
07:47 |
Sent To |
PC |
|
| Notes |
| 2007-04-10 18:59:00 | BUILDING REVIEW SECOND CHECKLIST: | | | 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT AS REQUIRED | | | BY SEC. 713.13 FLORIDA STATUTE. | | | | | | 2- PROVIDE COPY OF IMPACT FEES PAID RECEIPT AS | | | REQUESTED ON PREVIOUS CHECKLIST. | | | | | | 3- FLAT ROOF NOA #04-0506.03: | | | A) SPECIFY ON SHEET 16WHICH FASTENING OPTION IS | | | GOING TO BE USED AS REQUIRED BY CITY POLICY FOR ROOFING | | | PERMITS. SEE ATTACHED COPY. | | | | | | B) PROVIDE RAS 117 CALCULATIONS OR NAIL ENHANCING | | | FOR PERIMETER AND CORNER AREAS AS REQUIRED BY GENERAL | | | LIMITATION #7. SEE PAGE 19 OF NOA SUBMITTED. | | | | | | 4-DESIGNER OF RECORD NEED TO SPECIFY CONCRETE TILE | | | SPECIFIC FASTENING AS REQUIRED BY SEC. 106.1.1.2 OF | | | CITY AMENDMENTS TO FBC 2004. PRODUCT APPROVAL IS ONLY | | | TO VERIFY THAT PRODUCT MEETS DESIGNER OF RECORDDESIGN | | | CRITERIA. | | | | | | 5- PROVIDE PRODUCT APPROVAL AS REQUIRED BY RULE 9B-72 | | | FOR: | | | A) POCKET FRENCH SLIDING GLASS DOORS AS SHOWN ON | | | PLANS.NOA #02-0306.01 SUBMITTED IS NOT FOR POCKET | | | DOORS AND DOOR IS SMALLER THAN SIZE SPECIFIED ON PLANS. | | | THEREFORE, IT DOESN'T WORK FOR THIS HOUSE. | | | | | | B) 3'-6" X 8'-0" INSWING ENTRY DOOR AS SHOWN ON | | | PLANS.NOA #02-0129.10 SUBMITTED DOOR IS SMALLER THAN | | | SIZE SPECIFIED ON PLANS AND NOA IS EXPIRED ALSO. | | | | | | C) FIXED WINDOWS. NOA #03-0428.03 SUBMITTED IS | | | SUPERSEDED ACCORDING TO DADE COUNTY PRODUCT APPROVAL | | | WEBSITE. SEE ATTACHED COPY. NEED CURRENT NOA. | | | | | | 6- DESIGNEROF RECORD TO REVIEW AND APPROVE IN WRITING | | | ALL PRODUCT APPROVALSAS REQUIRED BY SEC. 106.3.3 CITY | | | AMENDMENTS TO FBC 2004. | | | ***NOTE: DESIGNEROF RECORD TO MAKE SURE PRODUCT | | | APPROVALS COVERTYPE AND SIZE OF PRODUCT SPECIFIED ON | | | PLANS AND IS NOT EXPIRED TO AVOID FURTHER DENIALS AND | | | EXPEDITE THE REVIEW PROCESS. | | | | | | 7- PROVIDE COMPLETE SPECIFICATIONS AND UL LISTING FOR | | | BBQ DESIGNED TO BE INSTALLED IN THE LOGGIA. OTHERWISE, | | | DELETE FROM DRAWINGS AND APPLY FOR SUCH PERMIT AT TIME | | | OF INSTALLATION. | | | | | | 8- REVISE ALL SECTIONS/DETAILS THAT SHOW CORRECT RAIN | | | DOWNSPOUTS TO COMPLY WITH SEC. R320.7 2004 FLORIDA | | | RESIDENTIAL CODE.ILLUSTRATED RAIN LEADERS ARE NOT | | | SHOWN CORRECTLY. | | | | | | 9- CONNECTORS P AND O SHOWN ON SHEETS-2DON'T MEET | | | THE UPLIFT LOADS SPECIFIED ON PLANS. REVISE/CLARIFY AS | | | REQUIRED. | | | | | | 10- SHEET S-4: | | | A) CLARIFY GRAVITY LOADS. WHY ATTIC LIVE LOAD FOR | | | ATTIC WITHOUT STORAGE IS NONCONCURRENT, WHILE ATTIC | | | LIVE LOAD WITH STORAGE IS CONCURRENT. SEC. 106.1.2 CITY | | | AMENDMENTS TO FBC 2004. | | | | | | 11- SOIL TEST REPORTTO HAVE ORIGINALENGINEER'S | | | SIGNATURE,DATE AND THE ENGINEERING FIRM'S CERTIFICATE | | | OF AUTHORIZATION NUMBER AS REQUIRED BY CHAPTER 471 AND | | | FLORIDA ADMINISTRATIVE CODE SEC. 61G15-23.002. | | | | | | 12-A) SURVEY TO HAVE ORIGINAL SIGNATURE, NOT COPY AS | | | REQUIRED BY CHAPTER 472 FLORIDA STATUTE. | | | B) PROVIDE COMPLETE INFORMATION FOR FLOOD MAP, | | | INCLUDING DATE OF MAP (MARCH 1ST. 1979). | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-01-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-01-23 |
Time |
17:53 |
Rev Time |
4.00 |
| Received By |
jgomez |
Date |
2007-01-23 |
Time |
17:53 |
Sent To |
|
|
| Notes |
| 2007-01-23 17:55:52 | BUILDING REVIEW CHECKLIST: | | | 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT AS REQUIRED | | | BY SEC. 713.13 FLORIDA STATUTES. | | | | | | 2- PAY IMPACT FEES TO PALM BEACH COUNTY. NEED TO BRING | | | BACK STAMPED PLANS AND COPY OF PAID RECEIPT. | | | | | | 3- TRUSSES WILL BE REQUIRED FOR REVIEW PRIOR TO | | | INSTALLATION. SEE SEC. R802.10 OF 2004 FLORIDA | | | RESIDENTIAL CODE FOR REQUIRED INFORMATION TO BE ON | | | TRUSS DRAWINGS. DESIGNER OF RECORD TO REVIEW AND | | | APPROVE THEM PRIOR TO SUBMITTAL. | | | | | | 4- PROVIDE DRAINAGE PLANS AS REQUIRED BY SEC. R401.3 | | | 2004 FLORIDA RESIDENTIAL CODE. | | | | | | ***NOTE: SEE SURVEY FOR FINISH FLOOR ELEVATIONS ON | | | ADJACENT PROPERTIES AND PROPOSED FINISH FLOOR ELEVATION | | | FOR THIS HOUSE TO AVOID DIVERTING WATER TO ADJACENT | | | PROPERTIES. | | | | | | 5- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE | | | 9B-72 FOR: | | | A) FLAT ROOF SYSTEM. SEE ATTACHED COPY OF CITY | | | POLICY FOR ROOFING PERMITS FOR REQUIRED INFORMATION. | | | FOR FLAT ROOF SYSTEMS NEED TO SELECT SPECIFIC APPROVED | | | ASSEMBLY AND FASTENING OPTION. IN ADDITION CHECK IF | | | SYSTEM IS LIMITED BY GENERAL LIMITATION #7 OR #9 | | | (LIMITATION #9 CAN'T BE INSTALLED IN THIS AREA) AND | | | PROVIDE REQUIRED INFORMATION ALSO. SEE GENERAL | | | LIMITATIONS ON PRODUCT APPROVAL SUBMITTED. | | | | | | B) POCKET FRENCH SLIDING GLASS DOORS AS SHOWN ON | | | PLANS. | | | | | | C) PARALAM BEAMS AS SHOWN ON PLANS. | | | | | | D) PRECAST LINTELS AS SHOWN ON PLANS. | | | | | | E) CONCRETE FLAT ROOF TILE.NOA 01-0417.09 EXPIRED | | | ON 06/07/2006.NEED CURRENT PRODUCT APPROVAL. ALSO, | | | SPECIFY TILE FASTENING. IF USING POLYFOAM FOR | | | ATTACHMENT, THEN PROVIDE PRODUCT APPROVAL FOR | | | POLYFOAM. | | | | | | F) GARAGE DOOR. ES LEGACY REPORT #2318 SUBMITTED | | | STATES THAT THIS REPORT BELONGS TO FLORIDA PRODUCT | | | APPROVAL FL674. THERE ARE NOT RECORDS FOR FL674.GO TO | | | WWW.FLORIDABUILDING.ORG TO VERIFY INFORMATION. PROVIDE | | | CURRENT GARAGE DOOR PRODUCT APPROVAL. | | | | | | G) 3'-6" X 8'-0"***INSWING*** MAHOGANY ENTRY DOOR | | | AS SHOWN ON PLANS. | | | | | | H) 3'-0" X 6'-8"***INSWING*** ENTRY DOOR AT GUEST | | | SUITE AS SHOWN ON PLANS. | | | | | | I) ENTRY DOOR SIDELITES. | | | | | | J) DOOR AND WINDOW STRUCTURAL MULLIONS AND SPECIFY | | | FASTENING. | | | | | | K) FIXED WINDOWS AS SHOWN ON PLANS. | | | | | | 6- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | | | | 7- PROVIDE MANUFACTURER'S SPECS THAT ALLOWS DECORATIVE | | | CHIMNEY CAPS. THEN, PROVIDE COMPLETE SPECS SUCH AS | | | CLEARANCES, MATERIALS ETC. SEC. 106.1.2 CITY AMENDMENTS | | | TO FBC 2004. | | | | | | 8- PROVIDE COMPLETE STRUCTURAL SECTION THRU FIREPLACE | | | AND CHIMNEY. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | 9- PROVIDE COMPLETE SPECIFICATIONS AND UL LISTING FOR | | | BBQDESIGNED TO BE INSTALLED IN THE LOGGIA. SEC. | | | 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | 10- SHEET A-0:A) NAME OF SOIL TEST ENGINEER DOESN'T | | | MATCH NAME OF COMPANY WHO SUBMITTED THE SOIL TEST | | | REPORT. REVISE AS REQUIRED. | | | | | | B) NAME OF SURVEYOR DOESN'T MATCH NAME OF SURVEYOR | | | WHO SUBMITTED SURVEY. REVISE AS REQUIRED. | | | | | | C) PROPOSED FINISH FLOOR ELEVATIONS DON'T MATCH | | | PROPOSED FINISH FLOOR ELEVATIONS SHOWN ON SURVEY. | | | REVISE EITHER ONE TO MATCH. | | | | | | 11- SHEET A-1:NOTE BY LOGGIA AREA CALLS FOR CENTER | | | LINE OF FIREPLACE AND CABANA DOORS. WHERE IS THE | | | FIREPLACE?. REVISE AS REQUIRED. | | | | | | 12-PROVIDE HANDRAIL AND GUARDRAILS DETAILS SHOWING | | | DESIGN LOADS COMPLIANCE AS REQUIRED BYSEC. 1607.7.1 | | | FBC 2004 AND SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | 13- CONTRACTOR'S WORKER'S COMPENSATION INSURANCE IS | | | EXPIRED. UPDATE INFORMATION WITH PERMIT CLERK. | | | | | | 14- EXTERIOR ELEVATIONS, WALL SECTIONS AND DETAIL CALL | | | FOR DIFFERENT ROOF SHEATHING SIZE. SOME CALL FOR 3/4" | | | PLYWOOD AND SOME CALL FOR 5/8" PLYWOOD. REVISE THEM ALL | | | AS REQUIRED TO MATCH. | | | | | | 15- SPECIFY FIREBLOCKING INALL WALL SECTIONS AS | | | REQUIRED BY SEC. R602.8 OF 2004 FLORIDA RESIDENTIAL | | | CODE. | | | | | | 16- PROVIDE COMPLETE SPECS AND INSTALLATION FOR | | | COLONIAL SHUTTERS SHOWN ON ELEVATIONS.SEC. 106.1.2 | | | CITY AMENDMENTS TO FBC 2004 ANDSEC. R301 FOR WIND | | | LOADS. AND, CLARIFY IF DECORATIVE SHUTTERS OR | | | STRUCTURAL SHUTTERS. STRUCTURAL SHUTTERS REQUIRE | | | PRODUCTAPPROVAL AND COMPLETE INSTALLATION SCHEDULE. | | | | | | 17- PROVIDE ATTIC VENTILATION CALCULATIONS AND VENT | | | SIZES AND LOCATION TO COMPLY WITH SEC. R806 OF 2004 | | | FLORIDA RESIDENTIAL CODE. | | | | | | 18- PROVIDE SPECIFICATIONS FOR GARAGE INTERIOR DOOR TO | | | COMPLY WITH SEC. R309.1 2004 FLORIDA RESIDENTIAL CODE. | | | | | | 19- PROVIDE SPECIFICATIONS FOR RAIN DOWNSPOUTS TO | | | COMPLY WITH SEC. R320.7 2004 FLORIDA RESIDENTIAL CODE. | | | | | | 20-MASTER WALK-IN-CLOSET; SPECIFY SIZE OF ATTIC | | | ACCESS TO COMPLY WITH SEC. R807 2004 FLORIDA | | | RESIDENTIAL CODE. | | | | | | 21- WALL SECTIONS: SPECIFY MINIMUM FOOTING DEPTH BELOW | | | GRADE AND MINIMUM. HEIGHT ABOVE GRADE AS REQUIRED BY | | | SEC. R403.1.4ANDSEC. R404.1.6OF 2004 FLORIDA | | | RESIDENTIAL CODE. | | | | | | 22- WINDOW AND DOOR DETAILS ON SHEET A-12 DON'T APPLY | | | TO THIS JOB. DELETE AS REQUIRED.PROVIDE ONLY THE | | | DETAILS THAT APPLY TO THIS JOB. | | | | | | 23- SHEET S-2:A) THERE ARE SOME DETAILSTHAT ARE | | | KEYED FOR SHEET S-6. THERE IS NOT SHEET S-6. REVISE AS | | | REQUIRED.EG: 3/S-6 AND 4/S-6. | | | | | | B) CONNECTORS M AND N ARE FOR WOOD TO WOOD | | | CONNECTIONS. NEED TO SPECIFY WOOD TO MASONRY CONNECTORS | | | AS REQUIRED.SEE SIMPSON CATALOGUE FOR PROPER MASONRY | | | CONNECTOR AND TYPE AND NUMBER OF FASTENERS.OTHERWISE, | | | PROVIDE COMPLETE ENGINEERING ANALYSIS FOR CONNECTORS | | | AND FASTENERS THAT ARE DIFFERENT THAN THOSE TESTED AND | | | PUBLISHED BY THE MANUFACTURER. SEC. 106.1.2 CITY | | | AMENDMENTS TO FBC 2004. | | | | | | C) SPECIFY SPECIFIC SIMPSON HANGER FOR STAIRS 2X12 | | | CARRIAGES. | | | | | | D) SPECIFY CONNECTORS FOR GIRDER TRUSSES ENDS BY | | | STAIRWAY AND GIRDER TRUSS END BYFAMILY ROOM AREA. SEE | | | PLANS FOR COMMENTS. | | | | | | 24- SHEET S-3:A) COORDINATE LOCATION OF ATTIC ACCESS | | | BY MASTER BEDROOM WITH ARCHITECTURAL DRAWINGS. | | | | | | B) WHERE ARE DETAILS 2/S-6. THEREIS NOT SHEET | | | S-6. | | | | | | C) SPECIFY UPLIFT LOAD AND CONNECTOR FOR GIRDER | | | TRUSS RESTING ON CHIMNEY SIDE. SEE PLANS FOR COMMENTS. | | | | | | D) CLARIFY DETAIL 4/S-5 KEYED ON LEFT BOTTOM CORNER | | | OF GUEST SUITE ROOF.DETAIL 4/S-5 IS FOR A BUCKET | | | DETAIL. CLARIFY/REVISE AS REQUIRED. | | | | | | E) SPECIFY LEDGER SIZE AND FASTENERS AROUND CHIMNEY | | | TO RECEIVE ROOF TRUSSES. SEE PLANS. | | | | | | 25- SHEET S-4:A) REVISE STRUCTURAL NOTES. CLEARLY | | | INDICATE DESIGN CRITERIA AS REQUIRED BY SEC. R301 OF | | | 2004 FLORIDA RESIDENTIAL CODE. INCLUDE ALL LOADS | | | INCLUDING LIVE AND DEAD LOADS. AND, ATTIC LIVE LOADS | | | FOR ATTIC WITH STORAGE AND ATTICS WITHOUT STORAGE AS | | | REQUIRED BY TABLE R301.5 2004 FLORIDA RESIDENTIAL CODE. | | | SPECIFY ALL LOADS. EG:ALL DEAD LOADS PLUS 30PSF LIVE | | | LOAD FOR ROOF IS NOT PROVIDING ALL NECESSARY | | | INFORMATION. REVISE ALL INFORMATION AS REQUIRED. | | | | | | B) INCLUDE 2004 FLORIDA RESIDENTIAL CODE WHICH IS | | | THE CODE THAT APPLIES TO ONE AND TWO FAMILY DWELLINGS. | | | | | | C) NOTE I REFERS TO SOIL TEST REPORT BY ARDAMAN AND | | | ASSOCIATES. THIS IS NOT THE SOIL TEST REPORT SUBMITTED | | | WITH PLANS. REVISE/COORDINATE AS REQUIRED. SEE PROVIDED | | | SOIL TEST REPORT. | | | | | | 26- ENERGY CALCULATIONS:A) REVISE CONDITIONED AREA TO | | | MATCH ARCHITECTURAL DRAWINGS. | | | | | | B) REVISE UNDER ATTIC AREA. SEE ARCHITECTURAL | | | PLANS. | | | | | | C) CLARIFY WHERE ARE THE SINGLE ASSEMBLY AREAS. | | | | | | D) REVISE INFORMATION ON TOP OF FORM.THE | | | PERMITTING OFFICE IS WEST PALM BEACH NOT PALM BEACH | | | COUNTY AND THE CORRECT JURISDICTION # IS 604700 NOT | | | 601000. | | | | | | 27- SURVEY SUBMITTED;A) SURVEY TO HAVE ORIGINAL | | | SIGNATURE (NOT COPY) AS REQUIRED BY CHAPTER 472 FLORIDA | | | STATUTES. | | | | | | B) PROPERTY IS LOCATED ON FLOOD ZONE "B" NOT "A5". | | | SEE MAP DATED MARCH 1, 1979.REVISE AS REQUIRED. | | | | | | C) PROVIDE COMPLETE INFORMATION FOR FLOOD MAP. | | | INCLUDE SUFFIX AND DATE OF MAP . | | | | | | D) SURVEY IS MISSING THE DIMENSIONS FOR THE COVERED | | | REAR PORCH. | | | | | | 28- SOIL TEST REPORT SUBMITTED: A) ENGINEER TO PROVIDE | | | ORIGINAL SIGNATURE, NOT COPY AS REQUIRED BY CHAPTER 471 | | | FLORIDA STATUTES AND FLORIDAADMINISTRATIVE CODE. | | | | | | B) NEED THE FIRM'S CERTIFICATE OF AUTHORIZATION | | | NUMBER IN THE LETTERHEAD AS REQUIRED BY SEC. | | | 61G15-23.002 OF FLORIDA ADMINISTRATIVE CODE. | | | | | | | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
F |
Date |
2008-11-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-11-12 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-11-12 |
Time |
15:02 |
Sent To |
PC |
|
| Notes |
| 2008-11-12 15:06:36 | | | | | | | REVISION DENIED | | | | | | THE PLANS SUBMITTED FOR RESTAMP ARE IN FACT A REVISION. | | | A CHANGE WAS HAND DRAWN IN THE BATHROOM (106) AND NOT | | | NOTED IN THE REVISION BOX. | | | ALSO ATTACHED ARE COMMENTS FROM THE LAST REVISION FROM | | | DEWEY PALMER, THE ELECTRICAL REVIEWER OF RECORD. DIRECT | | | FURTHER COMMUNICATIONS TO HIM. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2008-04-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-04-10 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-04-10 |
Time |
10:34 |
Sent To |
PC |
|
| Notes |
| 2008-04-10 10:36:07 | REDLINED DISCONNECT PER 110.26. | | | | | | STILL NEED REVISED PLANS FOR FINAL INCLUDING REVISED | | | PANEL SCHEDULES FOR CIRCUITS ETC. 408.4, 240.4, 310.16 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2008-04-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-04-01 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2008-04-10 08:34:54 | ELEC FOR RE-STAMP ONLY. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2008-03-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-03-21 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-03-21 |
Time |
09:07 |
Sent To |
M |
|
| Notes |
| 2008-03-21 09:07:48 | ** DENIEDREVIEW ** | | | | | | | | | 1) NOTE:PLANS ARE BEING SUBMITTED FOR RE-STAMP ONLY. | | | PLEASE SEE FLORIDA STATUTES 481.221 AS A *RUBBER-STAMP* | | | MAY NOT BE USED IN LIEU OF ORIGINAL SIGNATURE. | | | PLEASE BE SURE TO SUBMIT PLANS ACCORDINGLY. | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-05-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-05-18 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-05-18 |
Time |
16:38 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-04-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-04-17 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-04-17 |
Time |
12:01 |
Sent To |
M |
|
| Notes |
| 2007-04-17 12:02:05 | REDLINED A/C DISC TO BE PER 110.26 | | | PLANS OK, STAMPED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-03-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-21 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-21 |
Time |
07:55 |
Sent To |
M |
|
| Notes |
| 2007-03-21 12:59:37 | | | | ** UNSAT ** | | | | | | 1) NOTE: PLEASE SEE PREVIOUS REVIEW WHICH REQUESTED THE | | | AIC RATINGS FOR THE SERVICE EQUIPMENT AND PLANS NOW | | | INDICATE THE RATINGS FOR THE PANELS ONLY. PLEASE | | | INDICATE THE RATINGS FOR MAINS ALSO. | | | 110.9 | | | FBC 106.1.2 | | | | | | 2) NOTE: PLEASE SEE RISER WHICH SHOWS PANEL A-1 AS 100A | | | AND PANEL A-1 WHICH IS SHOWN AS 150AMP. | | | PLEASE CORRELATE. | | | FBC 106.1.2 | | | | | | 3) NOTE: PLEASE SEE THAT THE IDENTIFICATION OF THE | | | RECESSED LIGHTS WAS ADDED HOWEVER ONLY FOR THE IC | | | RATING. PLEASE SEE THE SECTION AS STATED ALSO REQUIRES | | | FIXTURES TO BE AIR TIGHT. | | | FBC 13-606.1.ABC.1.2.4 | | | | | | 4) NOTE: PLEASE CLARIFY WHERE THE RECESSED LIGHTING IS | | | FIGURED INTO THE LOAD CALCULATIONS AT THE MAXIMUM | | | NUMBER OF FIXTURES TIME THE NUMBER OF FIXTURES? | | | 220.3B4 | | | | | | 5) NOTE: PLEASE SEE THE PANEL SCHEDULE WHICH STILL LIST | | | MANY CIRCUITS AS *GENERAL*. | | | PLEASE SEE THE FOLLOWING TEXT WHICH IS EXTRACTED FROM | | | THE NEC COMMENTARY FOR 408.4. | | | | | | *CODE TO REQUIRE THAT THE IDENTIFICATION FOR EVERY | | | CIRCUIT SUPPLIED BY A PANEL-BOARD OR SWITCHBOARD BE | | | LEGIBLE AND CLEARLY STATE THE SPECIFIC PURPOSE FOR | | | WHICH THE CIRCUIT IS USED. CIRCUITS USED FOR THE SAME | | | PURPOSE MUST BE IDENTIFIED AS TO THEIR LOCATION. FOR | | | EXAMPLE, SMALL APPLIANCE BRANCH CIRCUITS CAN SUPPLY | | | OUTLETS IN THE KITCHEN, DINING ROOM, AND KITCHEN | | | COUNTERTOPS. IDENTIFYING THE CIRCUITS AS SMALL | | | APPLIANCE BRANCH CIRCUITS IS NOT ACCEPTABLE; INSTEAD, | | | THEY SHOULD BE IDENTIFIED AS ``KITCHEN WALL | | | RECEPTACLES,'' ``DINING ROOM FLOOR RECEPTACLE,'' OR | | | ``KITCHEN COUNTERTOP RECEPTACLES LEFT OF SINK.'' | | | CIRCUIT DIRECTORIES CONTAINING MULTIPLE ENTRIES WITH | | | ONLY ``LIGHTS'' OR ``OUTLETS'' DO NOT PROVIDE THE | | | SUFFICIENT DETAIL REQUIRED BY THIS SECTION.* | | | PLEASE KNOW IF THIS WAS THE ONLY COMMENT THIS COULD | | | HAVE BEEN REVISED, HOWEVER PLEASE INDICATE THE | | | ESTIMATED LOCATIONS AT THIS TIME PER DESIGNER. IT IS | | | KNOWN THAT THESE WILL MOST LIKELY BE INSTALLED | | | DIFFERENTLY AND MAY BE REVISED AT A LATER DATE. | | | 408.4, 310.16, 240.4 ETC | | | FBC 106.3.5.4 | | | | | | | | | ** PLEASE KNOW THAT SOME OF THESE COMMENTSWERE MADE | | | FROM THE PREVIOUS REVIEW AND SOME MAY HAVE BEEN | | | REDLINED OR SET UP AS A PROVISO, HOWEVER SOME CAN NOT. | | | PLEASE ADDRESS ALL AT THIS TIME AND IF THERE ARE ANY | | | COMMENTS, QUESTIONS, PLEASE CALL TO GO OVER. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-12-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-06 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-05 |
Time |
19:12 |
Sent To |
Z |
|
| Notes |
| 2006-12-06 09:16:04 | **** UNSAT **** | | | | | | 1) NOTE: PLEASE SEE THAT PLANS SHALL STATE THE | | | FOLLOWING MINIMUM CODES. | | | 2002 NFPA-70 (NEC), 2002 NFPA-72. | | | | | | 2) NOTE: PLEASE INDICATE THE MINIMUM AIC RATINGS FOR | | | ALL SERVICE EQUIPMENT. IT IS NOTED THAT THE SUB PANELS | | | INDICATE 10K , HOWEVER MAINS SHOULD CONTAIN THE MINIMUM | | | RATINGS ALSO. | | | PLEASE SEE 110.9 FBC 106.1.2 ADMIN SECTION. | | | | | | 3) NOTE: PLEASE SEE PLANS INDICATE A/F PROTECTION AS | | | EACH RECEPTACLE, HOWEVER BASED ON THE CODE AS STATED ON | | | E-3 AND IN 210.12B, THE PROTECTION IS FOR THE BRANCH | | | CIRCUIT. PLEASE KNOW IT IS NOT KNOWN TO THIS OFFICE AT | | | THIS TIME THAT A AF TYPE RECEPT IS MANUFACTURED. | | | | | | 4) NOTE: PLEASE INDICATE THE GFI PROTECTION FOR THE | | | JACUZZI/WHIRLPOOL TUB. 680.71 | | | | | | 5) NOTE: PLEASE SEE MISSING RECEPTS PER 210.52. (2FT OF | | | WALL IN BEDROOM #2 REDLINED). | | | PLEASE CHECK OTHER LOCATIONS, HOWEVER PLANS SEEM TO | | | INDICATE ALL REQUIRED. | | | | | | 6) NOTE: PLEASE SEE 210.52C3 FOR MISSING PENINSULAR GFI | | | RECEPTACLE REQUIRED. (REDLINED) | | | | | | 7) NOTE: PLEASE SEE NFPA-72 FOR DEFINITIONS OF SMOKE | | | DEVICES IN A DWELLING. PLEASE KNOW IN A RECENT SECTION | | | MEETING WITH NFPA, THE DESIGNATION OF THESE DEVICES | | | SHOULD BE AS FOLLOWS. PLEASE KNOW IF THE DEVICE IS 120V | | | WHICH DETECTS AND SOUNDS AND ALARM, THEN THIS DEVICE | | | WOULD ACTUALLY NOW BE SHOWN A "SA" FOR SMOKE ALARM. IF | | | THE DEVICE IS LOW VOLTAGE AND PART OF ALV SECURITY OR | | | LV FIRE ALARM SYSTEM , THEN DEVICE WOULD BE ONLY A "SD" | | | FOR SMOKE DETECTOR AS IT ONLY DETECTS AND WILL CAUSE | | | AND ALARM THROUGH OTHER SOUNDING DEVICES. PLEASE KNOW | | | THAT SD HAS BEEN THE ACCEPTED PRACTICE FOR MANY YEARS | | | THROUGH THIS AHJ, HOWEVER AS OF RECENT INFORMATION IF | | | INDEED THESE DEVICES ARE 120V SMOKE ALARMS, PLEASE | | | CHANGE THE DESIGNATIONS ON PLANS, NOTES AND SYMBOL | | | LEGEND. | | | | | | 8) NOTE: PLEASE ADJUST NOTES PERTAINING TO THE RELEVANT | | | CODES. PLEASE SEE NFPA-72 11.5.1.1 AND 11.8.3 DICTATES | | | THE PLACEMENT. | | | PLEASE SEE THAT THE SA DEVICE SHALL BE LOCATED WITHIN | | | 12INCHES OF THE HIGHEST POINT ON A FLAT/TRAY CEILING | | | AND WITHIN 3FT ON SLOPED ONLY CEILING. PLEASE KNOW, IF | | | THE TRAY IS 12INCHES OR MORE IN DEPTH, THE SA DEVICE | | | SHALL BE RELOCATED. | | | | | | 9) NOTE: PLEASE SEE AREA AT THE TOP OF THE STAIRS WHICH | | | SHOWS ONLY ONE SMOKE DEVICE. PLEASE KNOW DUE TO THE | | | DISTANCE AND LOCATION SHOWN, PLEASE EITHER ADD ONE UNIT | | | OR MOVE THE EXISTING TO BE CLOSER AND IN MORE OF THE | | | IMMEDIATE VICINITY OUTSIDE BEDROOMS #3 AND MASTER | | | BEDROOM. | | | NFPA-72 11.5.1.1 | | | | | | 10) NOTE: PLEASE SEE ANY POSSIBLE ZONING COMMENTS FOR | | | ANY CHANGES OR ACCESS REQUIREMENTS FOR THE GUEST SUITE | | | LOCATED IN THE REAR. PLEASE KNOW THESE COMMENTS MAY OR | | | MAY NOT AFFECT THE ELECTRICAL PLANS GREATLY. | | | | | | 11) NOTE: PLEASE INDICATE THE ACTUAL RATING OF THE | | | METER MAIN COMBO. PLEASE ALSO SHOW THIS E-1 PLAN | | | LAYOUT. | | | PLEASE SEE MISSING PANEL A-1 ON PLANS. THIS SUB PANEL | | | COULD NOT LOCATED ON LOWER OR UPPER FLOORS. PLEASE SEE | | | 110.26,240.24 ETC | | | FBC 106.1.2 ADMIN SECTION. | | | | | | 12) NOTE: PLEASE SEE PANEL SCHEDULES FOR BRANCH | | | CIRCUITING SHOULD BE MORE SPECIFIC TO AREAS IN WHICH | | | THEY FEED. IE: B-23 MASTER BRM LTS, A-1 KITCHEN LTS. | | | ETC | | | PLEASE KNOW IT IS KNOW THAT DURING THE CONSTRUCTION | | | THESE WILL MOST LIKELY CHANGE HOWEVER MINIMUMS SHALL BE | | | SHOWN AT THIS TIME. | | | PLEASE SEE 210.52B1 FOR DINING ROOMS AND AREAS OF THE | | | LIKE. | | | PLEASE SEE 240.4,310.16, 408.4. | | | FBC ADMIN SECTION, 106.1.2, 106.3.5.4 PAR(8). | | | | | | 13) NOTE: PLEASE INDICATE RECESSED LIGHTING IN LOAD | | | CALCULATIONS PER 220.3B4, PLEASE KNOW THIS MANY | | | FIXTURES CAN NOT BE CONSIDERED AS PART OF THE GENERAL | | | LIGHTING LOADS. | | | | | | 14) NOTE: PLEASE INDICATE THE REQUIREMENTS FOR AIR | | | TIGHT RATED FIXTURES AS REQUIRED PER FBC | | | 13-606.1.ABC1.2.4 | | | | | | 15) NOTE: PLEASE CORRELATE THE A/C'S. PLEASE SEE PANEL | | | SCHEDULES SHOW 3-10KW AHU'S AND LOAD CALCULATIONS | | | INDICATE 4-10KW SYSTEMS? | | | PLEASE SEE MECHANICAL PLANS WHICH INDICATE 2-15KW | | | SYSTEMS AND ONE 5KW.PLEASE KNOW BASED ON THE MAXIMUM | | | PERMITTED OVER CURRENT PROTECTION REQUIRED AND THE | | | AMOUNT OF LOADS ETC AS SHOWN ON THE M-SHEETS, IF THESE | | | UNITS ARE INSTALLED, THIS WILL GREATLY AFFECT THE | | | ELECTRICAL BRANCH CIRCUIT RATINGS. PLEASE CORRELATE AND | | | ADJUST AS THE EXACT SIZES CAN NOT BE VERIFIED AT THIS | | | TIME. | | | 310.16, 240.4, 424.3B, 424.22(A) AND (B). | | | | | | 16) NOTE:PLEASE INDICATE POOL PUMP AS FUTURE AS IT IS | | | NOT BEING INSTALLED AT THIS TIME. THIS CAN BE REVISED | | | AT A LATER DATE, OR IF POOL IS NOT BUILT DURING HOUSE | | | CONSTRUCTION THIS WILL NOT HAVE TO BE REVISED LATER. | | | | | | 17) NOTE: PLEASE SEE PANEL "A" WHICH SHOWS TWO | | | DEDICATED CIRCUITS FOR GARAGE DOOR OPENERS, YET PLANS | | | ONLY INDICATE ONE GDO RECEPT ON PLANS? | | | PLEASE CORRELATE. | | | FBC 106.1.2 ADMIN SECTION | | | 408.4. NEC. | | | | | | 18) NOTE: PLEASE CLARIFY THE LOCATION OF THE | | | DISCONNECTSSHOWN ON THE CU'S ETC. PLEASE SEE IN ORDER | | | TO CHANGE OUT THE EQUIPMENT, THE DISCONNECTBEING | | | MOUNTED DIRECTLY ON THE EQUIPMENT WOULD CREATE SOME | | | INTERFERENCE WIHT THIS. | | | | | | ** ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2006-12-06 07:02:23 | REVIEW COMMENCED | | 2006-12-05 19:12:18 | IN ELEC FOR REVIEW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2008-10-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-30 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-30 |
Time |
15:13 |
Sent To |
M |
|
| Notes |
| 2008-10-30 15:14:09 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2008-05-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-05 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-05 |
Time |
16:46 |
Sent To |
B |
|
| Notes |
| 2008-05-05 16:47:15 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2008-04-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-08 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-08 |
Time |
11:21 |
Sent To |
E |
|
| Notes |
| 2008-04-08 11:22:44 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-03-25 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2008-03-25 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2008-03-25 |
Time |
09:38 |
Sent To |
M |
|
| Notes |
| 2008-03-25 09:38:34 | ROUTED TO HAROLD MOSER'S DESK MMILLER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-03-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-20 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-20 |
Time |
09:58 |
Sent To |
B |
|
| Notes |
| 2008-03-20 09:59:11 | TO "JGOMEZ" DESK/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-05-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-16 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-16 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2007-05-16 11:01:49 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-04-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-16 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-16 |
Time |
16:44 |
Sent To |
E |
|
| Notes |
| 2007-04-16 16:44:39 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-03-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-20 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-20 |
Time |
11:10 |
Sent To |
E |
|
| Notes |
| 2007-03-20 11:10:59 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-03-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-16 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-16 |
Time |
10:20 |
Sent To |
Z |
|
| Notes |
| 2007-03-16 10:20:54 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-01-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-01-23 |
Time |
17:56 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2006-12-05 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2006-12-05 14:35:31 | TO "SFR" "Z" |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
P |
Date |
2008-11-13 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-11-13 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-11-13 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2008-11-13 14:58:42 | ***LANDSCAPE REVIEW PASSED WITH PROVISO*** | | | | | | FOUR (4) TREES SHALL BE INSTALLED WITHIN 45 DAYS FROM | | | THE DATE OF C/O.---RAK |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
9 |
Status |
P |
Date |
2008-11-05 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-11-05 |
Time |
13:54 |
Rev Time |
1.00 |
| Received By |
tgordon |
Date |
2008-11-05 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2008-11-05 13:55:31 | REVISION TO MECHANICAL PLANS, ENERGY CAL'S. AND COOLING | | | LOAD CAL'S. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
F |
Date |
2008-10-31 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-10-31 |
Time |
15:49 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-10-31 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2008-10-31 16:03:55 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | REVISION TO MECHANICAL PLANS | | | *** DENIED *** | | | | | | 1) THE ZONES FOR SYSTEM 1 AND 2 HAVE CHANGED, ALSO THE | | | SIZE OF SYSTEM 2 IS LARGER. THE COOLING LOAD | | | CALCULATIONS FOR ZONES 1 AND 2 NEED TO BE REVISED, PER | | | 2004 FBC 13-607.1.ABC.1. | | | | | | 2) THE SUPPLY AIR DUCT FROM AHU #3 TO THE MIXING BOX | | | AND FROM THAT MIXING BOX TO THE NEXT MIXING BOX, NEEDS | | | TO BE SIZED (SEE YELLOW HIGH LIGHT ON PLAN) PER 2004 | | | FBC/M 603.1 AND 603.2. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
F |
Date |
2008-10-23 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-10-23 |
Time |
14:15 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-10-23 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2008-10-23 14:19:54 | RE-STAMP | | | *DENIED* | | | | | | 1) PLANS ARE A REVISION. | | | | | | 2) MECHANICAL PLANS ON FILE ARE SIGNED AND SEALED BY | | | ARCHITECT (ROGER P JANSSEN) ONLY HE CAN MAKE REVISIONS | | | TO THEM, SEE FAC 61G1-16.003. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2008-04-01 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-04-01 |
Time |
11:28 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2008-04-01 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2008-04-01 11:30:19 | RE-STAMP PLANS. SENT TO LUIS M. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2008-03-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2008-03-25 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2008-03-25 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2008-03-25 17:20:59 | PLAN DENIED | | | PLANS MUST BE STAMPED BY THE ARCHITECTS, OR A LETTER | | | FROM DAILEY JANSSEN ARCHITECTS RELIEVEING HINSELF FROM | | | THE MECHANICAL PART OF THE JOB. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2008-03-21 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-03-21 |
Time |
11:04 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2008-03-21 |
Time |
11:04 |
Sent To |
P |
|
| Notes |
| 2008-03-21 11:09:23 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | ** RE-STAMP OF PLANS ** | | | *** DENIED *** | | | 1) THE ARCHITECT MUST SIGN WHEN SEALING PLANS (WET | | | SIGNATURE NOT RUBBER STAMP) PER FAC 61G1-16.003. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-04-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-04-17 |
Time |
14:15 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-04-17 |
Time |
14:15 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-03-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-26 |
Time |
12:14 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-03-26 |
Time |
12:14 |
Sent To |
P |
|
| Notes |
| 2007-03-26 12:21:18 | *** DENIED *** | | | 1) AS NOTED IN LAST REVIEW 12-16-07 NOTE #6. SEE | | | MECHANICAL PLANS PAGE M-1. THE 12" RETURN AIR TRANSFER | | | DUCT FROM THE PLAYROOM TO THE BREAKFAST AREA NEEDS TO | | | BE 14". | | | BALANCED RETURN AIR MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY INCREASING THE | | | RETURN TRANSFER ONE AND ONE HALF TIMES THE CROSS | | | SECTIONAL AREA (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING TO ACHIEVE | | | PROPER RETURN AIR BALANCE. PER 2004 FBC/R M1602.4 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-12-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-12-11 |
Time |
15:20 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-12-11 |
Time |
15:20 |
Sent To |
B |
|
| Notes |
| 2006-12-11 15:33:28 | *** DENIED *** | | | 1) THE MECHANICAL PLANS NEEDS THE ARCHITECT'S SEAL ON | | | THEM AS HIS INFORMATION IS IN THE TITLE BLOCK, PER FAC | | | 61G1-16.003. | | | | | | 2) SEE ELECTRICAL REVIEW NOTE #15, PLEASE CORRECT. | | | | | | 3) SEE PAGE M-2 SECOND FLOOR, SHOWER ROOM BETWEEN THE | | | TWO BEDROOMS NEEDS AN EXHAUST FAN, SEE 2004 FBC/R | | | M1506.1. | | | | | | 4) RETURN AIR DUCT TO AHU #3 NEEDS TO BE SIZED, SEE | | | HIGH LIGHT ON PAGE M-2. | | | | | | 5) TWO RETURN AIR DUCTS TO AHU #1 NEED TO BE SIZED | | | (PLEASE DO NOT USE PENCIL). | | | | | | 6) 12" RETURN AIR TRANSFER DUCT FROM PLAYROOM TO | | | BREAKFAST AREA NEEDS TO BE 14". BALANCED RETURN AIR MAY | | | BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (B)TRANSFER GRILLES SHALL USE 50 | | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | | CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND | | | USING AN UNRESTRICTED 1-INCH | | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | | RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2008-04-01 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-04-01 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-04-01 |
Time |
14:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2008-03-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-03-27 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-03-27 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2008-03-27 08:19:04 | DENIED; | | | SEE ELECTRICAL AND BUILDING PLAN REVIEW. PLANS MUST BE | | | SIGNED NOT COPYS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-06-04 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-06-04 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-06-04 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2007-06-04 10:38:25 | PROVISO; | | | | | | OUTSIDE SHOWER TO DRAIN TO PLANTED AREA OR FRENCH | | | DRAIN, NOT TO SANITARY. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-04-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-04-02 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-04-02 |
Time |
09:43 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-12-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-12-09 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-12-09 |
Time |
07:55 |
Sent To |
M |
|
| Notes |
| 2006-12-09 08:08:28 | DENIED; | | | 1. WATER HEATER DETAIL; SHUTOFF VALVE REQUIRED UP | | | STREAM OF THE EXPANSION TANK. PAGE A-1 SHOWS A TANKLESS | | | GAS WATER HEATER WHERE IS WATER HEATER IN DETAIL | | | LOCATED? IF RECIRC. SYSTEM IS USED ADD NOT INDICATING | | | INSULATION MATERIAL TO BE USED AROUND PIPES TO COMPLY | | | WITH FLORIDA ENERGY CODE. | | | 2. RISER DIAGRAM; UP STAIRS LAUNDRY WASHER AND L/T | | | CANNOT DISCHARGE THROUGHABATHROOM GROUP SECTION | | | 909.1. | | | 3. ADD NOTE TO PAGE A-1 " OUTSIDE SHOWER TO DRAIN TO | | | GRASSY AREA OR DRYWELL" | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-06-05 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-06-05 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-06-05 |
Time |
13:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-03-19 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2007-03-19 |
Time |
18:22 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2007-03-19 |
Time |
18:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-12-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-12-07 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-12-07 |
Time |
10:46 |
Sent To |
M |
|
| Notes |
| 2006-12-07 11:51:08 | DENIED, | | | 1. PLEASE PROVIDE THE DIMENSION OF THE PROPOSED | | | DRIVEWAY AND WALKWAY (LENGTH & WIDTH). | | | NOTE: MUST MAINTAIN 1000SQ FT OR 75% OF LANDSCAPE, | | | WHICHEVER IS LESS WITHIN THE FIRST 25FT FRONT SETBACK. | | | | | | NOTE: MUST PULL A SEPARATE PERMIT FOR THE POOL/SPA | | | | | | NOTE: POOL EQUIPMENT SHALL BE NO CLOSER THAT 6FT FROM | | | THE SIDE SETBACK.SEC 94-303 MECHANICAL/POOL | | | EQUIPMENT/GENERATOR MAY NOT PROJECT MORE THAN FOUR FEET | | | INTO A SETBACK. | | | | | | NOTE: MUST PULL A SEPARATE PERMIT FOR THE | | | GATE/COLUMNS/FENCE/PIERS WITH EASEMENT APPROVAL FROM | | | THE CITY OF WEST PALM BEACH UTILITIES DEPT. | | | | | | 2. THE PROPOSED GUEST ROOM MUST HAVE INTERIOR ACCESS | | | FROM THE FIRST FLOOR. STRUCTURE CANNOT BE RENTED OUT AS | | | A SEPARATE LIVING SPACE WITHIN THE MAIN STRUCTURE, SF7. | | | ELEVATON PLANS ALSO SHOWS THE STAIRS EXTERIOR FOR | | | ACCESS TO THE GUEST ROOM. | | | | | | 3. PLEASE SHOW ON THE ELEVATION PLAN THE FINISH GRADE. | | | THE MAXIMUM HEIGHT ALLOWED IS 33FT WITH CHIMNEY. | | | | | | 4. THE PROPOSED GUTTER WITH ROOF CAN ONLY PROJECT 3FT | | | INTO SETBACK. SEC 94-305(2). | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 | | | | | | | | | | | | | | | |
|
|