| Plan Review Stops For Permit 06120001 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2009-06-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-06-05 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-06-05 |
Time |
08:48 |
Sent To |
Z |
|
| Notes |
| 2009-06-05 08:50:51 | REVISED SHEETS A2.1 AND A2.2 OK FOR BUILDING. | | | RELOCATION OF POOL EQUIPMENT REQUIRES ZONING AND | | | HISTORIC APPROVAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-10-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-10-05 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-10-05 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2007-10-05 10:33:21 | BUILDING PROVISO | | | | | | SIGNED AND SEALED TRUSS DRAWINGS APPROVED BY THE | | | DESIGNER OF RECORD ARE REQUIRED TO BE ON SITE FOR THE | | | BUILDING INSPECTOR. | | | | | | REVISED SHEETS S-1, S-3, S-6, S-8, S-9 AND S-10 HAVE | | | BEEN REVIEWED FOR CODE COMPLIANCE. SHEETS S-2, S-4, | | | S-5, S-7 AND S-15 HAVE NO CHANGES FROM THE PERMITTED | | | PLANS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2007-09-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-09-26 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-09-26 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2007-09-26 13:47:04 | THE ORIGINAL SCOPE OF WORK IS BEING EXPANDED TO INCLUDE | | | REPLACING THE ROOF ASSEMBLY OF THE EXISTING STRUCTURE. | | | | | | REVISED TRUSS DRAWINGS ARE DENIED. | | | | | | 1) SUBMIT TWO SETS OF SIGNED AND SEALED ROOF FRAMING | | | PLANS SPECIFYING THE CONNECTORS THAT WILL BE USED TO | | | ATTACH THE NEW TRUSSES TO THE EXISTING BUILDING. | | | | | | 2) SUBMIT TWO SETS OF TRUSS DRAWINGS AND TRUSS LAYOUTS | | | THAT HAVE BEEN SIGNED AND SEALED BY THE TRUSS ENGINEER | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR | | | THE STRUCTURE. | | | | | | 3) SPECIFY THE COSTS OF THIS ADDITIONAL WORK SO THAT | | | THE VALUE OF THE JOB CAN BE ADJUSTED AND ADDITIONAL | | | PERMIT FEES CAN BE DETERMINED. | | | | | | 4) SUBMIT PRODUCT APPROVALS FOR ROOFING IF IT WILL BE | | | DIFFERENT THAN THE ONES THAT WERE APPROVED WHEN THE | | | PERMIT WAS ISSUED. | | | | | | - ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-04-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-04-20 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-04-20 |
Time |
06:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-04-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-04-06 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-04-05 |
Time |
17:25 |
Sent To |
|
|
| Notes |
| 2007-04-06 07:52:06 | DENIED BY BUILDING (2ND REVIEW) | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) SUBMIT A COPY OF THE PAID RECEIPT FOR THE IMPACT | | | FEES. | | | | | | 3) THE INSTALLATION DRAWINGS AND DESIGN PRESSURE TABLES | | | IN THE NOA 05-1018.01 SUBMITTED FOR THE PGT SINGLE HUNG | | | WINDOWS ARE ILLEGIBLE. | | | | | | 4)PAGE 5 OF 7 OF THE PRODUCT APPROVAL NOA FOR THE PGT | | | MULLIONS IS ILLEGIBLE. | | | | | | 5) SUBMIT PRODUCT APPROVALS FOR THE TRUSS CONNECTORS, | | | STRAPS HANGERS AND OTHER SPECIED STRUCTURAL ANCHORS. | | | SEE COMMENT #22 FROM FIRST REVIEW. | | | | | | 6) THE PAGES CONTAINING THE APPROVED ASSEMBLIES ARE | | | MISSING FROM THE PRODUCT APPROVAL NOA 03-0501.02 FOR | | | THE GAF MODIFIED ROOF SYSTEM. SPECIFY WHICH ONE OF THE | | | APPROVED ASSEMBLIES WILL BE INSTALLED. SPECIFY THE | | | FASTENING OPTION AND DESIGN PRESSURE FOR THE SYSTEM | | | (CIRCLE THE ITEMS ON THE PAGE OF THE APPROVED ASSEMBLY | | | SELECTED). ENHANCED FASTENING WILL BE REQUIRED FOR ROOF | | | ZONE3 (-89PSF) AND POSSIBLY ROOF ZONE 2 (-59.2) | | | DEPENDING ON THE SYSTEM THAT IS USED. NONE OF THE | | | ASSEMBLIES THAT HAVE GENERAL LIMITATION #9 WILL WORK | | | BECAUSE THIS LIMITATION DOES NOT ALLOW ENHANCED | | | FASTENING. THEREFORE, ONLY THE ASSEMBLIES WITH GENERAL | | | LIMITATION #7, WHICH ALLOWS THE DESIGN PRESSURE TO BE | | | INCREASED BY INCREASING THE FASTENER DENSITIES | | | CALCULATED BY USING ROOFING APPLICATION STANDARD 117 | | | CALCULATIONS. SUBMIT RAS 117 CALCULATIONS FOR THE | | | SELECTED ASSEMBLY. SEE ITEM # 23 FROM FIRST REVIEW. | | | | | | 7) SUBMIT PRODUCT APPROVALS FOR ARCH TOP WINDOWS. SEE | | | ITEM # 20 OF FIRST REVIEW. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-02-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-02-08 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-02-07 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2007-02-07 07:41:40 | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT | | | MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3)SHEETS A5.1 AND A5.2 SPECIFY A MINIMUM SOIL BEARING | | | CAPACITY OF 2500 PSF. THE SOIL REPORT AND STRUCTURAL | | | PLANS SPECIFY THE MINIMUM SOIL BEARING CAPACITY AS 1500 | | | PSF. PLEASE CORRECT. | | | | | | 4) SUBMIT A DRAINAGE PLAN FOR THE LOT SHOWING | | | COMPLIANCE WITH R401.3. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS | | | TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO | | | DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE | | | GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM | | | OF 6 INCHES (152 MM) WITHIN THE FIRST 10 FEET (3048 | | | MM). | | | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER | | | PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL | | | WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE | | | PROVIDED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. | | | | | | 5)ON SHEET A1.1 UNDER DESIGN CRITERIA SPECIFY THE | | | 2004 FBC. THE EXPOSURE CATEGORY OF B IS INCORRECTLY | | | SPECIFIED AS WIND CLASSIFICATION. PLEASE CORRECT. UNDER | | | GENERAL REQUIREMENTS, THE SOIL BEARING CAPACITY IS | | | SPECIFIED AS 2500 PSF. PLEASE CORRECT. | | | | | | 6)SHOW COMPLIANCE WITH R320.7 PROTECTION AGAINST | | | TERMITES AND DECAY. CONDENSATE LINES AND ROOF | | | DOWNSPOUTS SHALL DISCHARGE AT LEAST 1 FOOT AWAY FROM | | | THE STRUCTURE SIDEWALL, WHETHER BY UNDERGROUND PIPING, | | | TAIL EXTENSIONS OR SPLASH BLOCKS. GUTTERS WITH DOWN | | | SPOUTS ARE REQUIRED ON ALL BUILDINGS WITH EAVES OF LESS | | | THAN 6 INCHES HORIZONTAL PROJECTION EXCEPT FOR GABLE | | | END RAKES OR ON A ROOF ABOVE ANOTHER ROOF. | | | | | | 7) SHOW THE SCUPPERS AND DOWNSPOUTS ON THE | | | ELEVATIONS.R903.4 ROOF DRAINAGE. | | | UNLESS ROOFS ARE SLOPED TO DRAIN OVER ROOF EDGES, ROOF | | | DRAINS SHALL BE INSTALLED AT EACH LOW POINT OF THE | | | ROOF. WHERE REQUIRED FOR ROOF DRAINAGE, SCUPPERS SHALL | | | BE PLACED LEVEL WITH THE ROOF SURFACE IN A WALL OR | | | PARAPET. THE SCUPPER SHALL BE LOCATED AS DETERMINED BY | | | THE ROOF SLOPE AND CONTRIBUTING ROOF AREA. R903.4.1 | | | WHEN OTHER MEANS OF DRAINAGE OF OVERFLOW WATER IS NOT | | | PROVIDED, OVERFLOW SCUPPERS SHALL BE PLACED IN WALLS OR | | | PARAPETS NOT LESS THAN 2 INCHES (51 MM) NOR MORE THAN 4 | | | INCHES (102 MM) ABOVE THE FINISHED ROOF COVERING AND | | | SHALL BE LOCATED AS CLOSE AS PRACTICAL TO REQUIRED | | | VERTICAL LEADERS OR DOWNSPOUTS OR WALL AND PARAPET | | | SCUPPERS . AN OVERFLOW SCUPPER SHALL BE SIZED IN | | | ACCORDANCE WITH THE FLORIDA BUILDING CODE, PLUMBING . | | | | | | 8)THE EAST ELEVATION ON A3.2INDICATES GARAGE AT THE | | | PORTE-COCHERE. PLEASE CORRECT. | | | | | | 9)THE 7.6" DIMENSION ON STAIR SECTION 4/A5 IS THE | | | RISER HEIGHT NOT THE TREAD DEPTH AS INDICATED. PLEASE | | | CORRECT. | | | | | | 10) SECTION5/S8 SPECIFIES THE (F1) FOOTER WIDTH AS | | | 2'-0". THE SCHEDULE ON S10 SPECIFIES 2'-4" FOR THIS | | | FOOTER. PLEASE CLARIFY. | | | | | | 11) ON SHEETS S1, S2, AND S3 THERE ARE TAGS FOR | | | SECTIONS ON S9A, HOWEVER, THERE IS NO SHEET S9A IN THE | | | PLANS. PLEASE CORRECT. | | | | | | 12) ON SHEET A0.0 THE DRAWING LIST IS INCORRECT FOR THE | | | STRUCTURAL SHEETS. PLEASE CORRECT. | | | | | | 13) SECTION 5/S5 SHOWS ONE 2 XLEDGER FOR L3 AND THE | | | SCHEDULE ON S10 SPECIFIES TWO 2 X 12. PLEASE CLARIFY. | | | | | | 14) INDICATE HOW THE RAIN WATER WILL BE DRAINED FROM | | | THE SECOND FLOOR TERRACES WHICH APPEAR TO HAVE WALLS ON | | | THEIR PERIMETERS. | | | | | | 15) ON SECTION 4/S4 FIREBLOCKING IS REQUIRED BETWEEN | | | THE FLOOR AND WALL CONCEALED SPACES. SEE R602.8. | | | | | | 16) ON SECTION 6/S8 THE FOOTER HEIGHT IS ILLEGIBLE. | | | | | | 17) THE CONNECTOR SCHEDULE ON S10 HAS NO ID NUMBERS TO | | | CORRESPOND WITH THE NUMBERS ABOVE THE UPLIFTS ON THE | | | ROOF FRAMING PLAN ON S3. PLEASE CLARIFY. | | | | | | 18) ON SHEET S15 UNDER DESIGN DATAITEM 10 GIVES THE | | | DESIGN LIVE LOADS FOR RETAIL AND THIS PROJECT IS | | | RESIDENTIAL. PLEASE CORRECT. | | | | | | 19)THE PRODUCT APPROVALS FOR THE PGT WINDOWS AND | | | FRENCH DOORS ARE EXPIRED. PLEASE SUBMIT CURRECT PRODUCT | | | APPROVAL WITH CURRENT FL COVERSHEETS. | | | | | | 20) SUBMIT PRODUCT APPROVALS FOR THE ARCH TOP DOORS AND | | | SINGLE HUNG ARCH TOP WINDOWS. | | | | | | 21) SUBMIT PRODUCT APPROVALS FOR STRUCTURAL MULLIONS. | | | | | | 22) SUBMIT PRODUCT APPROVALS FOR TRUSS CONNECTORS, | | | STRAPS, HANGERS AND OTHER STRUCTURAL ANCHORS. | | | | | | 23) ON THE PRODUCT APPROVAL FOR THE GAF MODIFIED ROOF | | | SYSTEM, SPECIFY THE APPROVED SYSTEM THAT WILL BE | | | INSTALLED. SPECIFY THE FASTENING OPTION AND MAXIMUM | | | DESIGN PRESSURE THAT WILL BE USED. CIRCLE THE | | | APPROPRIATE ITEMS ON THE NOA. IF ENHANCED FASTENING IS | | | REQUIRED FOR THE PERIMETER AND CORNER AREAS,SUBMIT | | | RAS 117 CALCULATIONS AS REQUIRED BY LIMITATION NUMBER | | | 7. | | | | | | 24)SPECIFY WHICH ATTACHMENT METHOD WILL BE USED TO | | | INSTALL THE CLAY ROOF TILES. CIRCLE THE APPROPRIATE | | | ITEM ON THE NOA. | | | | | | 25) SUBMIT A KEY PLAN AND INSTALLATION SCHEDULE FOR THE | | | STORM PANELS. INDICATE THE OPENINGS ON WHICH THEY WILL | | | BE INSTALLED. SPECIFY THE FASTENER TYPE AND SPACING, | | | THE CONNECTION TYPE,THE SPANS, THE PRESSURES, ETC. | | | | | | 26)WPB ADMIN CODE 106.3* PRODUCT | | | APPROVALS. THOSE PRODUCT WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | NOTE: PLEASE REMOVE OLD SHEETS FROM THE PLANS AND | | | INSERT THE NEW ONES. SUBMIT ONE SET OF THE OLD PLANS | | | FOR REFERENCE TO HELP EXPEDITE REVIEWS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2009-04-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-04-29 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-04-29 |
Time |
14:19 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2009-04-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-04-15 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-04-08 |
Time |
12:16 |
Sent To |
PC |
|
| Notes |
| 2009-04-15 08:28:49 | | | | | | | PERMIT #06120001 ELECTRICAL PLAN REVIEW | | | 290 BARCELONA ROAD 4/14/09 | | | WEST PALM BEACH, FL. | | | | | | | | | | | | | | | NOTE- ALL CODE ARTICLES REFERENCED ARE 2005 NEC UNLESS | | | OTHERWISE NOTED. | | | SHEET E2.1 | | | 1} PANEL "P" IS LISTED AS 150 AMP ON THE PANEL | | | SCHEDULE, SHOWN AS BEING FED FROM A 80 AMP BREAKER IN | | | PANEL "C" AND NOTE #13 LISTS IT AS A 80 AMP PANEL. | | | CORRELATE THESE NUMBERS TO INDICATE THE INTENDED | | | INSTALLATION. 408.4, AND RECALCULATE THE LOAD FOR PANEL | | | C PER 220. | | | | | | 2} NOTE #12 LISTS 3-#3 CU AS FEEDERS FOR PANEL P, THE | | | LOAD IS SHOWN AS 145.41 AMPS IN THE TOTAL SERVICE | | | CALCULATION (LISTED AS 145.21 KVA IN PANEL P ESTIMATED | | | DEMAND LOAD) ON THE PANEL SCHEDULE. SEE 310.16 FOR WIRE | | | SIZES AND ALLOWABLE AMPERAGES. | | | | | | 3} THE PANEL AMPERAGES IN THE TOTAL SERVICE CALCULATION | | | ARE LISTED IN AMPS AND AS KVA ON THE PANEL SCHEDULES, | | | PLEASE CORRECT. 408.4 | | | | | | 4} THE FEEDERS TO FOR DISCONNECT DP ARE ONLY RATED FOR | | | 350 AMPS AND THE LOAD IS LISTED AS 393.5 AMPS. SEE | | | 310.15(B)(6) FOR FEEDER SIZES. | | | | | | 5} THERE SHOULD NOT BE A GROUNDING ELECTRODE CONDUCTOR | | | ON PANEL "P". PANELS P AND C ARE ON THE SAME STRUCTURE, | | | P IS FED FROM C AND A GROUNDING ELECTRODE IS SHOWN | | | INSTALLED ON THAT PANEL PER 250.32. PANEL P SHOULD BE | | | GROUNDED FROM THE EQUIPMENT GROUND RAN WITH THAT | | | FEEDER. SEE 250.122 FOR SIZE. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2009-03-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-03-09 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-03-09 |
Time |
14:00 |
Sent To |
M |
|
| Notes |
| 2009-03-09 14:59:39 | | | | | | | | | | REVISION DENIED | | | | | | 1} SHEET E1.1 THE LOW VOLTAGE PANEL UNDER THE STAIR IS | | | IN VIOLATION OF 110.26(A)(1), 3" MINIMUM CLEARANCE. | | | | | | 2} SHEET E1.2 INCORRECTLY HAS REVISION #3 DATED | | | FEBRUARY 9, 2009.REVISION #3 IN THE CITY'S FILE COPY IS | | | DATED 6/21/08 ON THAT SHEET. | | | | | | 3} THE REVISION ON SHEET E2.1 SHOWS A CONDUIT FROM | | | PANEL "DP" TO PANEL "P" AND A FEED FROM PANEL "C" PER | | | NOTE #12, YET NEITHER PANEL INDICATES A FEED TO PANEL | | | "P" IN THE PANEL SCHEDULES. | | | | | | NOTE: A PLUMPING REVISION MUST BE SUBMITTED FOR THE | | | ADDED SINK IN THE CABANA. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2008-07-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-07-28 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-07-28 |
Time |
15:10 |
Sent To |
M |
|
| Notes |
| 2008-07-28 16:13:07 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC,2004 FBC CHAPTER | | | 1 AS AMENDED AND FOUND NONCOMPLIANT WITH THE | | | FOLLOWING: | | | | | | REVISION DENIED | | | | | | 1} SHEET E1.1 THE LOW VOLTAGE PANEL IN THE STAIRWELL OF | | | THE CABANA DOES NOT COMPLY WITH THE CLEARANCE | | | REQUIREMENTS OF 110.26. | | | | | | 2} A SMOKE ALARM IS REQUIRED ".OUTSIDE EACH SEPARATE | | | SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE | | | BEDROOMS" THE STUDY IS BY DEFINITION.A BEDROOM. NFPA-72 | | | REQUIRES ALARMS OR DETECTORS WITHIN 20 FEET OF COOKING | | | APPLIANCES BE SILENCING OR PHOTOELECTRIC. SEE | | | 11.8.3.5(4). | | | | | | 3} THE RECEPTACLES ON THE COUNTERTOP ON EITHER SIDE OF | | | THE RANGE ARE REQUIRED TO BE GFI PROTECTED PER | | | 210.8(A)(6). I HAVE REDLINED COMMENTS 2 & 3 ON THE | | | PREVIOUS REVISION WHICH THE ARCHITECT PROBABLY WAS NOT | | | AWARE. | | | | | | NOTE: SHEET E1.2 APPEARS TO BE COMPLIANT AND WILL NOT | | | NEED TO BE RESUBMITTED. | | | | | | 5} SHEET E2.1THE 350 MCM FEEDERS TO PANEL "DP" ARE NOT | | | LARGE ENOUGH TO CARRY THE 393 AMP LOAD. SEE NOTE #4 FOR | | | THE RISER DIAGRAM.SEE TABLE 310.15(B)(6). | | | | | | 6} THE DISCONNECT "DP" IS RATED FOR 300 AMPS, NOT LARGE | | | ENOUGH FOR THE LOAD.SEE NOTE #16, ALSO REVISE NOTE #3T | | | | | | 7} THERE IS NO FEED FOR PANELS "C" AND "P" LISTED IN | | | "DP PANEL SCHEDULE.NOTE #12 INDICATES PANEL "C" MAY BE | | | FEEDING PANEL"P",CONTRARY TO NOTE #7, AND NOT SHOWN ON | | | PANEL"C" SCHEDULE. | | | | | | 8} PANEL "DP" IS LISTED AS 300 AMPS, SEE NOTE #19. | | | | | | 9} THE ESTIMATED LOADS AT THE BOTTOM OF THE SCHEDULES | | | IS RATED IN KVA. THE "TOTAL SERVICE FOR THE MAIN HOUSE | | | AND CABANA" THE BOTTOM MIDDLE OF THE SHEET LISTS RATING | | | IN AMPS "DP" AND "P" ARE INCORRECT. RECHECK ALL | | | CALCULATIONS AND CORRELATE THE LOADS. | | | | | | 10} THE TANKLESS HEATERS ON SHEET E1.1 ARE NOT ON ANY | | | OF THE SCHEDULES, INDICATE IF THEY ARE GAS. IF THEY ARE | | | ELECTRIC THEY WILL POSSIBLY LOAD THE SERVICE OVER 400 | | | AMPS. | | | | | | 11} LOCATE PANEL "P" ON THE PLAN. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-04-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-04-18 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-04-18 |
Time |
10:28 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-03-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-03-27 |
Time |
18:11 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2007-03-27 |
Time |
17:16 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-12-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-12-19 |
Time |
15:28 |
Rev Time |
1.50 |
| Received By |
btrobaug |
Date |
2006-12-19 |
Time |
11:29 |
Sent To |
P |
|
| Notes |
| 2006-12-19 15:28:48 | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1} LOCATE ALL SERVICE EQUIPMENT ON THE PLAN, METER | | | ENCLOSURE, DISCONNECTS AND PANELS, SO THAT COMPLIANCE | | | WITH ARTICLES 225 AND 230 CAN BE REVIEWED. | | | | | | 2} THE EQUIPMENT GROUNDING CONDUCTOR MUST COMPLY WITH | | | 250.66. SEE NOTE #1 REGARDING THE SUM OF THE SERVICE | | | ENTRANCE CONDUCTORS. MINIMUM #1/0 CU.( SHEET E2.1). | | | | | | 3} PLEASE ADD A NOTE FOR HEXAGONAL #22, SHEET E2.1. | | | | | | 4} PLEASE CORRECT NOTE #16, THE EQUUIPMENT BEING | | | REFERENCED IS A DISCONNECT. | | | | | | 5} PLEASE CORRECT PANEL "DP"LOAD CALC TOTAL.SEE SHEET | | | E2.1. | | | | | | 6} SMOKE ALARMS ARE REQUIRED INSIDE AND IMMEDIATLY | | | OUTSIDE THE " PRIVATE READING ROOM" , WHICH IS A | | | "BEDROOM" BY DEFINITION IN THE FBC. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
19 |
Status |
N |
Date |
2009-08-06 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-08-06 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-08-06 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2009-08-06 10:42:04 | IN ZONING BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2009-07-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-07-27 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-07-27 |
Time |
13:48 |
Sent To |
Z |
|
| Notes |
| 2009-07-27 13:49:26 | LANDSCAPE PLANS SENT TO ZONING RM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2009-07-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-07-23 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-07-23 |
Time |
14:18 |
Sent To |
B |
|
| Notes |
| 2009-07-23 14:19:04 | TO RMCD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2009-06-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-06-03 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-06-03 |
Time |
13:18 |
Sent To |
B |
|
| Notes |
| 2009-06-03 13:19:48 | BUILDING REVISION SENT TO ROBERT MCDOUGAL'S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2009-04-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-04-29 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-04-29 |
Time |
13:02 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2009-03-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-03-30 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-03-30 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2009-03-30 09:42:33 | TO IN-BOX "R9" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2009-03-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-03-05 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-03-05 |
Time |
13:49 |
Sent To |
E |
|
| Notes |
| 2009-03-05 13:50:22 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2008-07-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-24 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-24 |
Time |
10:57 |
Sent To |
E |
|
| Notes |
| 2008-07-24 10:57:54 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2008-05-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-05 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-05 |
Time |
08:23 |
Sent To |
M |
|
| Notes |
| 2008-05-05 08:24:55 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2008-04-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-28 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-28 |
Time |
16:23 |
Sent To |
M |
|
| Notes |
| 2008-04-28 16:23:55 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2008-04-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-24 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-24 |
Time |
13:39 |
Sent To |
P |
|
| Notes |
| 2008-04-24 13:39:51 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2008-04-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-17 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-17 |
Time |
16:33 |
Sent To |
E |
|
| Notes |
| 2008-04-17 16:33:50 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-10-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-03 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-03 |
Time |
12:55 |
Sent To |
B |
|
| Notes |
| 2007-10-03 12:56:02 | TO "RMCDOUGAL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-09-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-14 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-14 |
Time |
14:10 |
Sent To |
B |
|
| Notes |
| 2007-09-14 14:11:13 | TO "RMCDOUGAL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-04-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-18 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-18 |
Time |
10:13 |
Sent To |
B |
|
| Notes |
| 2007-04-18 10:13:43 | TO "RMCDOUGAL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-03-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-24 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-24 |
Time |
12:12 |
Sent To |
E |
|
| Notes |
| 2007-03-24 12:12:45 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-03-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-21 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-21 |
Time |
09:52 |
Sent To |
Z |
|
| Notes |
| 2007-03-21 09:53:12 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-12-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-15 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-15 |
Time |
11:56 |
Sent To |
E |
|
| Notes |
| 2006-12-15 11:56:53 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-02-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-02-08 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-12-01 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2006-12-01 14:53:30 | TO "Z" BOX |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
P |
Date |
2009-08-07 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-08-07 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-08-07 |
Time |
14:39 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2009-03-16 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-03-16 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-03-16 |
Time |
08:37 |
Sent To |
PC |
|
| Notes |
| 2009-03-16 08:38:09 | REVISED M1.1 AND M2.1 REV.3 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2008-07-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-07-29 |
Time |
08:26 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2008-07-29 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2008-07-29 08:30:22 | REVISION TO MECH. PLANS M1.1 AND M1.2. | | | | | | *** PROVISO *** | | | 1) PER 2004 FBC/M 603.15.1 FLOOR REGISTERS. | | | FLOOR REGISTERS SHALL RESIST, WITHOUT STRUCTURAL | | | FAILURE, A 200-POUND (90.8 KG) CONCENTRATED LOAD ON A | | | 2-INCH (51 MM) DIAMETER DISC APPLIED TO THE MOST | | | CRITICAL AREA OF THE EXPOSED FACE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2008-05-05 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-05-05 |
Time |
12:25 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2008-05-05 |
Time |
12:25 |
Sent To |
|
|
| Notes |
| 2008-05-05 12:26:47 | REVISION TO MECH. PLANS M1.1 AND M1.2. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-04-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-04-29 |
Time |
09:07 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2008-04-29 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2008-04-29 09:08:42 | REVISION TO MECHANICAL PLANS PAGES M1.1, M1.2, ENERGY | | | CAL'S, AND COOLING LOAD CAL'S. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2008-04-21 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-04-21 |
Time |
08:43 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-04-21 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2008-04-21 08:52:28 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | REVISION TO MECHANICAL PLANS | | | *** DENIED *** | | | 1) COOLING LOAD CALCULATIONS ON FILE ARE CALLING FOR | | | A/C SYSTEM 1 TO BE A TOTAL OF 36,423 COOLING BTU'S, | | | REVISED MECHANICAL PLANS ARE SHOWING A TOTAL OF 48,500 | | | COOLING BTU'S. PER 2004 FBC 13-607.1.ABC.1.1 THE PLANS | | | CAN ONLY CALL FOR 15% MORE THAN THE COOLING LOAD | | | CALCULATIONS, PLEASE CORRECT. | | | | | | 2) COOLING LOAD CALCULATIONS ON FILE ARE CALLING FOR | | | A/C SYSTEM 2 TO BE A TOTAL OF 41,781 COOLING BTU'S, | | | REVISED MECHANICAL PLANS ARE SHOWING A TOTAL OF 60,000 | | | COOLING BTU'S. PER 2004 FBC 13-607.1.ABC.1.1 THE PLANS | | | CAN ONLY CALL FOR 15% MORE THAN THE COOLING LOAD | | | CALCULATIONS, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-03-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-28 |
Time |
08:32 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-03-28 |
Time |
08:32 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-12-21 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-12-21 |
Time |
11:52 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-12-21 |
Time |
11:52 |
Sent To |
B |
|
| Notes |
| 2006-12-21 11:57:38 | *** DENIED *** | | | 1) RETURN AIR TRANSFER DUCT TO MASTER SUITE NEEDS TO BE | | | 16". BALANCED RETURN AIR MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | 2) NOT ALL SUPPLY AND RETURN AIR DUCTS ARE SIZED SEE | | | HIGH LIGHTED DUCTS ON PLANS PAGE M1.1 AND M1.2, PLEASE | | | SIZE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2009-04-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-04-09 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-04-09 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2009-04-09 08:55:11 | REVISION OK -- SHT P1.1 | | | | | | ****************PROVISO**************** | | | (A) 708.3.4 BASE OF STACK. A CLEANOUT | | | SHALL BE PROVIDED AT THE BASE OF EACH | | | WASTE OR SOIL STACK | | | (B) 708.7 MINIMUM SIZE. CLEANOUTS SHALL | | | BE THE SAME NOMINAL SIZE AS THE PIPE | | | THEY SERVE UP TO 4 INCHES (102MM) | | | (C) 708.9 ACCESS. ACCESS SHALL BE | | | PROVIDED TO ALL CLEANOUTS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-04-28 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-04-28 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-04-28 |
Time |
10:20 |
Sent To |
PC |
|
| Notes |
| 2008-04-28 10:23:10 | REVISION SHEET A2.3: "OK" ADDITION OF TWO 3" ROOF | | | DRAINS FOR PRIMARY AND ONE 4" X 6" SCUPPER FOR | | | SECONDARY DRAINAGE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-03-30 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-03-30 |
Time |
10:37 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-03-30 |
Time |
10:37 |
Sent To |
B |
|
| Notes |
| 2007-03-30 10:41:49 | ****************PROVISO**************** | | | (A) 708.3.4 BASE OF STACK. A CLEANOUT | | | SHALL BE PROVIDED AT THE BASE OF EACH | | | WASTE OR SOIL STACK | | | (B) 708.7 MINIMUM SIZE. CLEANOUTS SHALL | | | BE THE SAME NOMINAL SIZE AS THE PIPE | | | THEY SERVE UP TO 4 INCHES (102MM) | | | (C) 708.9 ACCESS. ACCESS SHALL BE | | | PROVIDED TO ALL CLEANOUTS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-12-20 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-12-20 |
Time |
14:24 |
Rev Time |
2.00 |
| Received By |
mperson |
Date |
2006-12-20 |
Time |
14:24 |
Sent To |
M |
|
| Notes |
| 2006-12-20 16:55:50 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING | | | PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. PLEASE CLARIFY ON THE RESUBMITTED DRAWINGS EXACTLY | | | WHAT IS EXISTING STRUCTURE AND WHAT IS THE PROPOSED | | | ADDITION OR PROVIDE A LEGEND CLARIFYING THIS. | | | | | | 2. THE DISHWASHER INDICATED ON SHEET P1.1 IS INDICATED | | | WRONG ON THE SANITARY PLUMBING RISER DIAGRAM PER | | | FBC-2004 PLUMBING, SECTION 802.1. PLEASE CORRECT ON THE | | | RESUBMITTAL. | | | (A) 802.1.6 DISCHARGE INTO A WYE-BRANCH FITTING ON THE | | | TAILPIECE OF THE KITCHEN SINK OR THE DISHWASHER | | | CONNECTION OF A FOOD WASTE GRINDER, NOT OFF THE WASTE | | | ARM AS INDICATED. | | | | | | 3. PER THE FLOOR PLAN ON SHEET A2.1 THE ISLAND SINK | | | W/DISPOSAL IS MISSING ON THE SANITARY PLUMBING RISER | | | DIAGRAM ON SHEET P1.1. PLEASE CORRECT ON THE | | | RESUBMITTAL. | | | | | | 4. THE WASHING MACHINE LAUNDRY STACK IS SIZED WRONG | | | PER FBC-2004 PLUMBING, SECTION, 406.3. | | | (A) 406.3 WASTE CONNECTIONS.THE TRAP AND | | | FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES | | | WASHER SHALL BE A MINIMUM OF 2 INCHES | | | (51MM) IN DIAMETER. THE AUTOMATIC | | | CLOTHES WASHER FIXTURE DRAIN SHALL | | | CONNECT TO A BRANCH DRAIN OR DRAINAGE | | | STACK A MINIMUM OF 3 INCHES (76MM) IN | | | DIAMETER. | | | | | | 5. BATH #5 PER THE FLOOR PLAN ON SHEET A2.2 THE SHOWER | | | IS INDICATED INCORRECTLY ON THE SANITARY RISER DIAGRAM | | | ON SHEET P1.1 AS A TUB. PLEASE CORRECT ON THE | | | RESUBMITTAL. | | | | | | 6. SHEET P1.1, 2ND FLOOR SHOWER IN HIS BATH IS | | | INDICATING AN "S" TRAP. "S" TRAPS ARE PROHIBITED PER | | | FBC-2004 PLUMBING, SECTION 1002.3. PLEASE CORRECT ON | | | THE RESUBMITTAL. | | | | | | 7. SHEET A2.3 PLEASE PROVIDE THE FOLLOWING INFORMATION | | | IN RELATION TO THE ROOFS PER FBC-2004 PLUMBING, SECTION | | | 1106.2 AND 1106.4. | | | A} SQ. FT. OF FLAT ROOFS AND ADJOINING ROOFS THAT | | | SPILL ON FLAT ROOFS. | | | B} SQ. FT. OF VERTICAL WALLS. | | | C} SIZE OF RAIN WATER LEADERS AND DOWNSPOUTS. | | | D} PLEASE PROVIDE A DETAIL OF THESIZE AND LOCATION | | | OF THE EMERGENCY OVERFLOW SCUPPERS. | | | | | | 8. SHEET A3.2 PLEASE INDICATE THE RAIN LEADER, | | | DOWNSPOUT AND SCUPPER LOCATIONS ON THE WEST FACADE. | | | | | | 9. SHEET A3.3 PLEASE INDICATE THE RAIN LEADER, | | | DOWNSPOUT AND SCUPPER LOCATIONS ON THE SOUTH FACADE. | | | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2009-08-07 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2009-08-07 |
Time |
15:15 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2009-08-07 |
Time |
15:14 |
Sent To |
HIST |
|
| Notes |
| 2009-08-07 15:16:37 | REVISION FOR MECHANICAL EQUIPMENT SETBACKS. MATCHES | | | LOCATION ON SITE AND LANDSCAPE PLANS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2009-06-08 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2009-06-08 |
Time |
15:08 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
2009-06-08 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2009-06-08 15:16:04 | FAILED | | | | | | 1) THERE IS WHAT APPEARS TO BE POOL EQUIPMENT SHOWN | | | BETWEEN THE CABANA AND THE REAR PROPERTY LINE. THIS | | | ENCROACHES INTO THE REAR SETBACK, AND SHALL BE REMOVED | | | FROM ALL PLANS. | | | | | | 2) PERMIT NO. 09030404, THE POOL AND POOL EQUIPMENT | | | PERMIT, SHOWS THAT THE POOL EQUIPMENT IS ON A PAD SET | | | BACK 10.8 FEET FROM THE SIDE AND REAR PROPERTY LINES. | | | THE SUBMITTED PLANS DO NOT SHOW THIS EQUIPMENT PAD AND | | | THE POOL EQUIPMENT IN THE APPROVED LOCATION. | | | | | | 3) THE NEW AC LOCATION WAS NOT SUBMITTED FOR REVIEW AND | | | APPROVAL BY THE ZONING DIVISION. PROVIDE THE DIMENSIONS | | | OF THE EQUIPMENT FROM THE SIDE AND REAR PROPERTY LINES. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-03-22 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-03-22 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-03-22 |
Time |
15:15 |
Sent To |
I |
|
| Notes |
| 2007-03-22 15:16:10 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-12-13 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-12-13 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-12-13 |
Time |
09:52 |
Sent To |
I |
|
| Notes |
| 2006-12-13 13:29:34 | DENIED. | | | 1. PLEASE CLARIFY IF THE GENERATOR IS EXISTING AND WILL | | | BE APART OF THE SUBMITTED PROPOSED WORK. | | | 2.THE PROPOSED GENERATOR SHALL NOT BE CLOSER THAN 8FT | | | FROM REAR AND 1FT SIDE PROPERTY LINE. | | | | | | NOTE: SEPARATE PERMIT MUST BE PULLED FOR THE | | | POOL/SPA/DECK. | | | NOTE: POOL EQUIPMENT SHALL NOT BE CLOSER THAN 8FT FROM | | | THE REAR PROPERTY LINE. | | | | | | NOTE: MUST MAINTAIN 1000SQ FT OR 75% OF LANDSCAPE, | | | WHICHEVER IS LESS WITHIN THE FIRST 25FT FRONT SETBACK. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|