| Plan Review Stops For Permit 06110756 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2007-10-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-10-23 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-10-23 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2007-10-23 16:58:36 | REVISION TO CHANGE ROOF COVERING ON ADDITION AND | | | EXISTING STRUCTURE FROM ASPHALT SHINGLE TO CLAY TILE IS | | | OK. THE ENTIRE ROOF INCLUDING TRUSSES OF THE EXISTING | | | STRUCTURE WAS REPLACED. THE VALUE OF THE WORK HAS BEEN | | | INCREASED BY $8000.00, AN ADDITIONAL PERMIT FEE OF | | | $88.00 IS DUE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2007-08-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-08-31 |
Time |
17:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-08-31 |
Time |
17:21 |
Sent To |
|
|
| Notes |
| 2007-08-31 17:47:11 | REVISED SHEET 1 THAT WAS DENIED BY PLUMBING HAS BEEN | | | RESUBMITTED AND REVIEWED FOR COMPLIANCE AND OK'D. STAMP | | | AND PROCESS REVISED SHEETS 1,2 AND 3. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-08-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-08-16 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-08-16 |
Time |
07:34 |
Sent To |
|
|
| Notes |
| 2007-08-31 17:20:54 | REVISION TO SHEETS 1,2 AND 3 INCREASING THE SCOPE OF | | | WORK ARE OK FOR BUILDING. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2007-07-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-07-20 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-07-20 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2007-07-20 15:10:14 | REVISION DENIED BY BUILDING | | | | | | 1) THE VALUE OF THE PROJECT HAS INCREASED SIGNIFICANTLY | | | DUE TO THE ADDITIONAL SCOPE OF WORK. PLEASE INDICATE | | | THE COSTS OF THE ADDITIONAL WORK SO THAT THE VALUE OF | | | THE JOB CAN BE ADJUSTED. ADDITIONAL PERMIT FEES WILL BE | | | ASSESSED. | | | | | | 2)SPECIFY HOW THE GAS WATER HEATER IN THE GARAGE WILL | | | BE PROTECTED FROM MECHANICAL DAMAGE AS REQUIRED BY FBC | | | MECHANICAL 303.4. | | | | | | 3)SHOW COMPLIANCE WITH R309.1 OPENING PROTECTION. | | | OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM | | | USED FOR SLEEPING PURPOSES SHALL NOT BE PERMITTED. | | | OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL | | | BE EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 1-3 / 8 | | | INCHES (35 MM) IN THICKNESS, SOLID OR HONEYCOMB CORE | | | STEEL DOORS NOT LESS THAN 1 3 / 8 INCHES (35 MM) THICK, | | | OR 20-MINUTE FIRE-RATED DOORS. - | | | | | | 4)SHOW COMPLIANCE WITH R309.2 SEPARATION REQUIRED. | | | THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND | | | ITS ATTIC AREA BY NOT LESS THAN 1/2 -INCH (12.7 MM) | | | GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES | | | BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL | | | HABITABLE ROOMS ABOVE BY NOT LESS THAN 5 / 8 -INCH | | | (15.9 MM) TYPE X GYPSUM BOARD OR EQUIVALENT. WHERE THE | | | SEPARATION IS A FLOOR-CEILING ASSEMBLY, THE STRUCTURE | | | SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY | | | NOT LESS THAN 1/2-INCH (12.7 MM) GYPSUM BOARD OR | | | EQUIVALENT. | | | | | | 5) REVISE THE ROOF SHEATHING FASTENING NOTES ON SHEET 2 | | | TO COMPLY WITH FBC R803.2.3.1 OF 2006 REVISIONS TO 2004 | | | FBC RESIDENTIAL CODE. WHICH REQUIRES 8D RING-SHANK | | | NAILS AT 6 INCHES ON CENTER IN ROOF ZONES 1 AND 2 AND 4 | | | INCHES ON CENTER IN ROOF ZONE 3 (CORNERS) IN ACCORDANCE | | | WITH FIGURE R803.2.3.1. | | | | | | 6) THE SIMPSON CONNECTOR CATALOG REQUIRES A MINIMUM 12" | | | EMBED FOR THE MGT 5/8" EPOXY SET THREADED ROD. PLEASE | | | REVISE CONNECTOR NOTE ON SHEET 2. | | | | | | 7) SPECIFY THE GARAGE DOOR WINDLOAD PRESSURES ON THE | | | PLANS. SEE SHEET 1. | | | | | | 8)WPB ADMIN CODE 106.3* PRODUCT | | | APPROVALS. THOSE PRODUCT WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. THE SIGNED AND SEALED | | | LETTER SUBMITTED IS NOT SPECIFIC AND NOT ACCEPTABLE. | | | | | | - ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-03-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-03-20 |
Time |
18:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-03-20 |
Time |
18:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-02-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-02-28 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-02-28 |
Time |
06:14 |
Sent To |
|
|
| Notes |
| 2007-02-28 07:37:50 | DENIED BY BUILDING | | | | | | 1) THE REAR SET BACK ON THE SURVEY DOES NOT CONCUR WITH | | | THE SITE PLAN. PLEASE CORRECT. SEE ZONING COMMENTS. | | | | | | 2) THE UPLIFT VALUE LISTED ON THE PLANS FOR THE RT16 IS | | | INCORRECT FOR THE NUMBER AND TYPE OF FASTENERS THAT ARE | | | SPECIFIED. ACCORDING TO THE USP TECHNICAL BULLETIN THE | | | UPLIFT IS 700. | | | | | | 3) RE- SUBMIT THE FIRST SHEET OF THE OLD PLANS WHICH | | | HAS THE STAMP FOR THE COUNTY IMPACT FEES OR HAVE THE | | | NEW PLANS STAMPED BY THE COUNTY. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-02-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-02-06 |
Time |
07:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-02-05 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2007-02-06 07:32:08 | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) SUBMIT A COPY OF THE PAID RECEIPT FOR THE IMPACT | | | FEES. | | | | | | 3) ON SHEET 1, FOUNDATION NOTE 2 SPECIFIES 18 " DOWELS | | | EMBEDDED 4" INTO EXISTING SLAB AND 18 " INTO NEW SLAB. | | | THIS WOULD REQUIRE A 22" DOWEL PLEASE CORRECT. | | | | | | 4) TRUSS DESIGN DRAWINGS, PREPARED IN CONFORMANCE WITH | | | SECTION R802.1.6.1 , SHALL BE PROVIDED TO THE BUILDING | | | OFFICIAL AND APPROVED PRIOR TO INSTALLATION. TRUSS | | | DRAWINGS ARE REQUIRED TO BE SIGNED AND SEALED BY THE | | | TRUSS ENGINEER AND REVIEWED AND APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD FOR THE PROJECT. | | | | | | 5) THE ROOF SHEATHING FASTENING NOTE ON SHEET 2 | | | SPECIFIES FASTENER SPACING 4" OC AT GABLES. THE 4" | | | SPACING IS REQUIRED IN ROOF ZONE 3, WHICH ALSO INCLUDES | | | THE OUTSIDE CORNERS OF HIP AND FLAT ROOFS. PLEASE | | | REVISE. SEE FBC FIGURE 1609.6.2.2. | | | | | | 6) THE TRUSS CONNECTOR SCHEDULE ON SHEET 2 SPECIFIES | | | USP RT16A AND RT-16-2 WOOD FRAME TO WOOD TRUSS | | | CONNETORS WITH 8D NAILS TO STRUCTURE. THESE ARE | | | SPECIFIED AT THE EXISTING CONCRETE/MASONRY WALL. PLEASE | | | CORRECT. | | | | | | 7) TWO RT16-2 ARE SPECIFIED TO ANCHOR A GIRDER TRUSS TO | | | THE EXISTING CBS STRUCTURE. IT DOES NOT APPEAR THAT TWO | | | OF THESE CONNECTORS COULD BE INSTALLED AT THIS | | | LOCATION. PLEASE REVIEW AND IF THIS IS CORRECT, PROVIDE | | | A DETAIL AS TO HOW THEY SHOULD BE INSTALLED. | | | | | | 8) SUBMIT PRODUCT APPROVALS FOR THE HALF-LITE OUTSWING | | | DOORS AT THE MASTER BEDROOM AND THE KITCHEN. | | | | | | 9) SUBMIT AN INSTALLATION SCHEDULE FOR THE STORM PANELS | | | AT THE KITCHEN AND MASTER BEDROOM DOORS. SPECIFY THE | | | FASTENER TYPE AND SPACING, THE TYPE OF MOUNT , THE | | | CONNECTION TYPE, THE EDGE DISTANCE, THE PANEL SPAN, THE | | | DESIGN LOAD, ETC. | | | | | | NOTE : VALUE OF THE WORK HAS BEEN INCREASED TO $ | | | 162,068 AND RADON FEES ADDED. ADDITIONAL FEES ARE DUE. | | | | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-12-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-12-31 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-12-31 |
Time |
11:40 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-07-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-07-19 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-07-19 |
Time |
10:44 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2006-12-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-12-14 |
Time |
12:57 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-12-14 |
Time |
12:12 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2008-04-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-01 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-01 |
Time |
16:38 |
Sent To |
Z |
|
| Notes |
| 2008-04-01 16:38:31 | TO "Z" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2008-03-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-14 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-14 |
Time |
16:03 |
Sent To |
Z |
|
| Notes |
| 2008-03-14 16:03:56 | TO "Z" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2008-02-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-08 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-08 |
Time |
16:51 |
Sent To |
Z |
|
| Notes |
| 2008-02-08 16:51:29 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2008-01-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-07 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-07 |
Time |
08:59 |
Sent To |
M |
|
| Notes |
| 2008-01-07 08:59:30 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-12-21 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2007-12-21 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2007-12-21 |
Time |
16:34 |
Sent To |
E |
|
| Notes |
| 2007-12-21 16:35:12 | SENT TO "BT" DESK MMILLER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-10-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-23 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-23 |
Time |
10:59 |
Sent To |
B |
|
| Notes |
| 2007-10-23 11:00:23 | TO "RMCDOUGAL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-08-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-22 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-22 |
Time |
13:17 |
Sent To |
P |
|
| Notes |
| 2007-08-22 13:17:40 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-06 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-06 |
Time |
16:12 |
Sent To |
Z |
|
| Notes |
| 2007-08-06 16:13:08 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-07-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-10 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-10 |
Time |
16:38 |
Sent To |
Z |
|
| Notes |
| 2007-07-10 16:38:19 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-03-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-09 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-09 |
Time |
10:19 |
Sent To |
M |
|
| Notes |
| 2007-03-09 10:20:00 | TO "M" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-03-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-05 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-05 |
Time |
09:30 |
Sent To |
Z |
|
| Notes |
| 2007-03-05 09:30:47 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-02-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-26 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-26 |
Time |
16:06 |
Sent To |
M |
|
| Notes |
| 2007-02-26 16:06:23 | TO "M" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-02-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-21 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-21 |
Time |
10:35 |
Sent To |
Z |
|
| Notes |
| 2007-02-21 10:58:28 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-02-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-02-06 |
Time |
07:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-11-29 |
Time |
17:28 |
Sent To |
|
|
| Notes |
| 2006-11-29 17:28:46 | SENT TO ZONING |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
P |
Date |
2008-04-04 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-04-04 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-04-04 |
Time |
16:13 |
Sent To |
PC |
|
| Notes |
| 2008-04-04 16:15:21 | PROVISO--100% IRRIGATION COVERAGE TO ALL LANDSCAPED | | | AREAS IS REQUIRED.AN IRRIGATION PERMIT MUST BE | | | OBTAINED. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
P |
Date |
2008-04-03 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-03-24 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-04-03 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2008-03-24 15:32:04 | 1.FIVE SHADE OR FLOWERING TREES ARE REQUIRED AND ONLY | | | 35% OF THESE REQUIRED TREES CAN BE PALMS.PLEASE ADD | | | (2) SHADE OR FLOWERING TREES. | | | | | | 2.PROVIDE SOD AND IRRIGATION IN THE RIGHT-OF-WAY, | | | ADJACENT TO THE PROPERTY LINE. | | | | | | 3.THE EUGENIA SPECIES USED SHALL BE NATIVE.EUGENIA | | | UNIFLORA IS PROHIBITED. | | | | | | 4.STAFF SUGGESTS THAT A LOW GROUND COVER BE ADDED IN | | | FRONT OF THE HEDGE ALONG THE FOUNDATION OF THE | | | STRUCTURE TO CREATE A TIERED EFFECT.THE PALMS SHALL | | | BE INCORPORATED INTO THE PLANT BED.THIS WILL REDUCE | | | MAINTENANCE. | | | | | | 5.STAFF SUGGESTS THAT DRIVEWAYS, PATIOS AND WALKWAYS | | | SHOULD BE KEPT A MINIMUM OF FIVE FEET FROM ANY PROPERTY | | | LINE FOR DRAINAGE PURPOSES. | | | | | | 6.THE MULCHED AREA IN THE REAR OF THE SITE IS NOT | | | PERMITTED.EITHER A PLANTING OF SHRUBS AND GROUND | | | COVERS OR SOD IS REQUIRED FOR THAT AREA. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
P |
Date |
2008-01-09 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-01-09 |
Time |
09:33 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2008-01-09 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2008-01-09 09:35:11 | REVISION TO MECH. PLAN PAGE 2 AND RECEIVED COOLING LOAD | | | CAL'S. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
F |
Date |
2008-01-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-01-07 |
Time |
10:47 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-01-07 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2008-01-07 10:57:14 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | ** MECHANICAL REVISION ** | | | *** DENIED *** | | | 1) THIS WAS PROVISO-ED 8-9-07 BUT NEEDS TO BE SUBMITTED | | | WITH THIS REVISION. SUBMIT COOLING LOAD CALCULATIONS | | | FOR REVIEW BEFORE DUCT ROUGH INSPECTION, SEE 2004 FBC | | | 13-607.1.ABC.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2007-08-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-30 |
Time |
08:06 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2007-08-30 |
Time |
08:06 |
Sent To |
B |
|
| Notes |
| 2007-08-30 08:07:54 | REVISION PASSED REVIEW ON 8-9-07, WITH PROVISO. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-08-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-09 |
Time |
10:21 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-08-09 |
Time |
10:21 |
Sent To |
P |
|
| Notes |
| 2007-08-09 10:53:00 | *** PROVISO *** | | | 1) SUBMIT COOLING LOAD CALCULATIONS FOR REVIEW BEFORE | | | DUCT ROUGH INSPECTION, SEE 2004 FBC 13-607.1.ABC.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2007-07-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-24 |
Time |
09:30 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-07-24 |
Time |
09:30 |
Sent To |
P |
|
| Notes |
| 2007-07-24 09:36:30 | *** REVISION DENIED *** | | | 1) PLEASE SUBMIT REVISED ENERGY CALCULATIONS, SEE 2004 | | | FBC 13-101.2.3. | | | | | | 2) PROVIDE COMBUSTION AIR CALCULATIONS AND COMBUSTION | | | AIR IF NEEDED FOR GAS WATER HEATER IN GARAGE, SEE 2004 | | | FBC/R G2407.1. | | | | | | 3) PROVIDE COMBUSTION AIR CALCULATIONS AND COMBUSTION | | | AIR OR MAKE-UP AIR FOR GAS CLOTHES DRYER, SEE 2004 | | | FBC/R G240.7.1 AND G2407.4. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-03-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-12 |
Time |
14:09 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-03-12 |
Time |
14:09 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-27 |
Time |
09:25 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-02-27 |
Time |
09:25 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-12-21 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-12-21 |
Time |
09:07 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-12-21 |
Time |
09:06 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2007-08-24 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-08-24 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-08-24 |
Time |
10:31 |
Sent To |
Z |
|
| Notes |
| 2007-08-24 10:35:35 | REVISION: SHEET 1 REV/#3,4,&5. | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2007-08-14 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-08-14 |
Time |
08:34 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-08-14 |
Time |
08:34 |
Sent To |
B |
|
| Notes |
| 2007-08-14 08:43:07 | REVISION DENIED | | | REFERENCE: | | | ** FBC-2004 PLUMBING. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | 1. SHEET 1 PLUMBING RISER DIAGRAM MUST REFLECT THE | | | CHANGES IN BATH #3 WITH THE FOLLOWING INFORMATION PER | | | FBC-2004 CHAPTER 1, SECTION 106.3.5.4 RESIDENTIAL (ONE | | | AND TWO-FAMILY) PLEASE SUBMIT A PLUMBING SANITARY | | | ISOMETRIC RISER DIAGRAM INDICATING ALL WASTE, VENTS, | | | TRAPS AND SIZES WITH CLEANOUT LOCATIONS OF REVISED BATH | | | #3. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2007-07-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-13 |
Time |
08:07 |
Rev Time |
0.15 |
| Received By |
mperson |
Date |
2007-07-25 |
Time |
11:50 |
Sent To |
PC |
|
| Notes |
| 2007-07-25 13:24:29 | REVISION DENIED | | | REFERENCE: | | | ** FBC-2004 PLUMBING. | | | ** FBC-2004 FUEL GAS. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. SHEET 1: PLEASE INDICATE HOW THE NEW GAS WATER | | | HEATER IS TO BE PROTECTED IN THE PROPOSED 1 CAR GARAGE | | | PER FBC-2004 FUEL GAS, SECTION 303.4 PROTECTION FROM | | | PHYSICAL DAMAGE. APPLIANCES SHALL NOT BE INSTALLED IN A | | | LOCATION WHERE SUBJECT TO PHYSICAL DAMAGE UNLESS | | | PROTECTED BY APPROVED BARRIERS MEETING THE REQUIREMENTS | | | OF THE FLORIDA FIRE PREVENTION CODE. FOR EXAMPLE, AN | | | APPLIANCE (WATER HEATER) INSTALLED IN A GARAGE MIGHT BE | | | SUBJECT TO VEHICLE IMPACT. BARRIERS MUST BE APPROVED | | | AND STRONG ENOUGH TO RESIST THE TYPE OF IMPACT | | | ANTICIPATED. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-03-13 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-03-13 |
Time |
16:13 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-03-13 |
Time |
16:13 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-02-27 |
Time |
10:42 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-02-27 |
Time |
10:42 |
Sent To |
B |
|
| Notes |
| 2007-02-27 11:00:27 | | | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL INSPECTION. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-12-19 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-12-19 |
Time |
16:18 |
Rev Time |
0.55 |
| Received By |
mperson |
Date |
2006-12-19 |
Time |
16:18 |
Sent To |
M |
|
| Notes |
| 2006-12-19 16:51:56 | DENIED | | | REFERENCE: FBC-2004 PLUMBING AND FBC-2004 CHAPTER 1 | | | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING | | | PLAN REVIEW TO MEET CODE COMPLIANCE PLEASE REFERENCE | | | THE ATTACHED CORRECTED SANITARY RISER DIAGRAM IN RED | | | INK FOR THE RESUBMITTAL: | | | | | | 1. SHEET 1, PER FBC-2003 CHAPTER 1, SEC. 106.3.5.4 | | | RESIDENTIAL (ONE AND TWO | | | FAMILY) SUBMIT A PLUMBING SANITARY | | | ISOMETRIC RISER DIAGRAM INDICATING ALL | | | WASTE, VENTS, TRAPS WITH SIZES, AND | | | CLEANOUT LOCATIONS. | | | NOTE: NOT ALL TRAPS ARE SIZED AND THE DISH WASHER IS | | | MISSING. | | | | | | 2. SHEET 1, PER FBC-2004 PLUMBING, SEC. 917.4 THE AIR | | | ADMITTANCE VALVE IS INDICATED WRONG. THE AIR ADMITTANCE | | | VALVE SHALL BE LOCATED A MINIUM OF 4 INCHES ABOVE THE | | | HORIZONTAL BRANCH DRAIN OR FIXTURE DRAIN BEING VENTED. | | | | | | 3. SHEET 1, PER FBC-2004 PLUMBING, THE FOLLOWING IS | | | REQUIRED FOR THE WASHING MACHINE. | | | (A) 406.3 WASTE CONNECTIONS.THE TRAP AND | | | FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES | | | WASHER SHALL BE A MINIMUM OF 2 INCHES | | | (51MM) IN DIAMETER. THE AUTOMATIC | | | CLOTHES WASHER FIXTURE DRAIN SHALL | | | CONNECT TO A BRANCH DRAIN OR DRAINAGE | | | STACK A MINIMUM OF 3 INCHES (76MM) IN | | | DIAMETER. | | | (B) 802.4 STANDPIPES.STANDPIPES SHALL BE INDIVIDUALLY | | | TRAPPED. STANDPIPES SHALL | | | EXTEND A MINIMUM OF 18 INCHES (457MM) | | | AND A MAXIMUM OF 42 INCHES (1066MM) | | | ABOVE THE TRAP WEIR. ACCESS SHALL BE | | | PROVIDED TO ALL STANDPIPES AND DRAINS | | | FOR RODDING. PLEASE INDICATE STANDPIPE ON DRAWING. | | | (C)708.9 ACCESS. ACCESS SHALL BE PROVIDED TO ALL | | | CLEANOUTS. CLEANOUT FOR THE WASHING MACHINE TO BE AT | | | FOUR FEET ABOVE FINNISH FLOOR AND INDICATED AS SUCH ON | | | THE RESUBMITTAL. | | | | | | 4. PER FBC-2004, PLUMBING, SECTION 909.1 | | | WET VENT PERMITTED: ONLY THE FIXTURES | | | WITHIN THE BATHROOM GROUPS SHALL CONNECT | | | TO THE WET-VENTED HORIZONTAL BRANCH | | | DRAIN. ANY ADDITIONAL FIXTURES SHALL | | | DISCHARGE DOWNSTREAM OF THE WET VENT. | | | NOTE: ON SHEET 1, SANITARY RISER DIAGRAM ALL | | | BATHROOM-GROUPS ARE NON CODE COMPLIANT. PLEASE | | | REFERENCE THE ATTACHED CORRECTED SANITARY RISER DIAGRAM | | | IN RED INK FOR THE RESUBMITTAL. | | | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
9 |
Status |
P |
Date |
2008-04-04 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2008-04-04 |
Time |
12:21 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2008-04-03 |
Time |
12:20 |
Sent To |
L |
|
| Notes |
| 2008-04-04 12:21:16 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
8 |
Status |
F |
Date |
2008-03-25 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2008-03-25 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2008-03-24 |
Time |
16:21 |
Sent To |
I |
|
| Notes |
| 2008-03-25 10:26:23 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1. PLEASE INDICATE WHETHER THE PAVERS WILL BE SEALED OR | | | UNSEALED PAVERS.IN THE EVENT OF SEALED PAVERS, THE | | | LESSER OF 1,000 SQUARE FEET OR 75 PERCENT OF THE FRONT | | | YARD AREA SHALL BE LANDSCAPED. | | | | | | 2. PREVIOUSLY APPROVED PLANS SHOWED THE A/C UNIT ALONG | | | THE NORTH BUILDING FA?ADE; HOWEVER THE LANDSCAPE PLAN | | | SHOWS THE A/C UNIT TO BE LOCATED ALONG THE SOUTH | | | BUILDING FA?ADE OF THE NEW ADDITION.PROVIDE SETBACK | | | DIMENSIONS TO THE A/C UNIT.PLEASE NOTE THAT PER | | | SECTION 94-305(B)(4), MECHANICAL EQUIPMENTS MAY NOT | | | PROJECT MORE THAN 4 FEET INTO A SETBACK. | | | | | | 3. PURSUANT TO ARTICLE XIX OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS, OPEN SPACE MEANS AN OPEN, | | | UNENCLOSED AREA CONSISTING OF SETBACKS, LANDSCAPING, | | | BUFFERS, VEHICULAR AND PEDESTRIAN CIRCULATION FEATURES, | | | AND SURFACE PARKING.LANDSCAPING CALCULATIONS SHALL BE | | | REVISED TO INCLUDE THE ACTUAL OPEN SPACE AREA OF THE | | | PROPERTY. | | | | | | 4. PURSUANT TO SECTION 94-442(B)(1), ALL OPEN SPACE, | | | EXCLUDING VEHICULAR AND PEDESTRIAN CIRCULATION FEATURES | | | AND SURFACE PARKING, SHALL BE COVERED WITH GRASS, | | | GROUND COVER, SHRUBBERY, OR OTHER SUITABLE PLANT | | | MATERIAL.PROVIDE DETAILS OF WHAT THE MULCH AREA NORTH | | | OF THE BUILDING IS GOING TO BE USED FOR.IF THIS IS TO | | | BE OPEN SPACE OR YARD, THEN MULCH MAY NOT BE USED. | | | | | | 5. SHOW COMPLIANCE WITH THE XERISCAPE REQUIREMENTS | | | OUTLINED IN SECTION 94-442(G) OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
7 |
Status |
F |
Date |
2008-02-13 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2008-02-13 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2008-02-12 |
Time |
10:00 |
Sent To |
I |
|
| Notes |
| 2008-02-13 08:21:44 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1. PROVIDE THE TOTAL SQUARE FOOTAGE OF THE PROPOSED | | | CONCRETE DRIVEWAY AND WALKWAYS WITHIN THE FRONT YARD. | | | | | | 2. PROVIDE WIDTH AND DEPTH DIMENSIONS OF THE WALKWAY IN | | | FRONT OF THE MAIN FRONT ENTRANCE. | | | | | | 3. PURSUANT TO SECTION 94-482(A), THE LESSER OF 1,000 | | | SQUARE FEET OR 75 PERCENT OF THE FRONT YARD AREA MUST | | | BE LANDSCAPED.PROVIDE LANDSCAPE AREA CALCULATIONS. | | | | | | 4. PURSUANT TO SECTION 94-441(C)(2), RENOVATIONS, | | | REPAIR, ALTERATION OR REDEVELOPMENT WHICH EXCEED 50 | | | PERCENT OF THE VALUE OF THE STRUCTURE SHALL COMPLY WITH | | | ARTICLE XIV OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS.THE WORK VALUE OF THIS PERMIT ($206,000) | | | EXCEEDS THE VALUE OF THE STRUCTURE PER THE PROPERTY | | | APPRAISER?S OFFICE ($79,793). | | | | | | 5. PROVIDE 2 COPIES OF A LANDSCAPE PLAN SHOWING | | | COMPLIANCE WITH ARTICLE XIV OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS, TO INCLUDE THE COMMENTS STATED | | | ABOVE.PLEASE NOTE THAT PER SECTION 94-442(A), | | | LANDSCAPE PLANS FOR SINGLE-FAMILY DWELLING UNITS DO NOT | | | NEED TO BE SIGNED AND SEALED BY A FLORIDA REGISTERED | | | LANDSCAPE ARCHITECT. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
6 |
Status |
P |
Date |
2007-08-29 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-08-29 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-08-28 |
Time |
08:21 |
Sent To |
M |
|
| Notes |
| 2007-08-29 08:59:36 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. | | | | | | PLANNING AND ZONING DEPARTMENT | | | | | | ***PASSED*** | | | | | | PLEASE NOTE THAT THE PROPOSED POOL AND POOL DECK SHALL | | | BE APPROVED ON A DIFFERENT BUILDING PERMIT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2007-08-08 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-08-08 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-08-07 |
Time |
09:29 |
Sent To |
I |
|
| Notes |
| 2007-08-08 13:05:01 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. | | | | | | PLANNING AND ZONING DEPARTMENT | | | | | | ***PASSED*** | | | | | | PLEASE NOTE THAT THE PROPOSED POOL AND POOL DECK SHALL | | | BE APPROVED ON A DIFFERENT BUILDING PERMIT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2007-07-12 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-07-12 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-07-11 |
Time |
17:07 |
Sent To |
M |
|
| Notes |
| 2007-07-12 16:15:56 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. | | | | | | PLANNING AND ZONING DEPARTMENT | | | | | | ***PASSED*** | | | | | | PLEASE NOTE THAT THE PROPOSED POOL AND POOL DECK SHALL | | | BE APPROVED ON A DIFFERENT BUILDING PERMIT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-03-08 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-03-08 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-03-07 |
Time |
15:39 |
Sent To |
I |
|
| Notes |
| 2007-03-08 16:20:34 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. | | | | | | PLANNING AND ZONING | | | | | | ***PASSED*** | | | | | | PLEASE NOTE THAT THE PROPOSED POOL AND POOL DECK SHALL | | | BE APPROVED ON A DIFFERENT BUILDING PERMIT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-02-23 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-02-23 |
Time |
18:53 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-02-23 |
Time |
18:53 |
Sent To |
I |
|
| Notes |
| 2007-02-23 18:56:10 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1. PLEASE PROVIDE RESPONSE TO COMMENTS IN WRITING. | | | | | | 2. SURVEY SHOWS THE PROPOSED ADDITION'S REAR SETBACK IS | | | 8.9; HOWEVER, ACCORDING TO THE SITE PLAN, THE PROPOSED | | | REAR SETBACK IS 8.45.PLEASE INDICATE THE CORRECT | | | PROPOSED REAR SETBACK ON BOTH THE SURVEY AND SITE | | | PLAN. | | | | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL | | | PLANNER, AT 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-12-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-12-09 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-12-09 |
Time |
16:10 |
Sent To |
I |
|
| Notes |
| 2006-12-09 16:19:48 | DENIED, | | | 1. THE PROPOSED ADDITION MUST MEET THE REAR SETBACK OF | | | 15FT OR 10% OF LOT DEPT.PLANS SHOWS THE REAR SETBACK | | | AT 8.45FT. | | | 2. PLEASE PROVIDE A COPY OF CURRENT SURVEY. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|