| Plan Review Stops For Permit 06110681 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-03-28 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-03-28 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-03-28 |
Time |
05:58 |
Sent To |
P |
|
| Notes |
| 2007-03-28 08:16:42 | NOTE:THE REPORT FOR FLEXANE BRUSHABLE CURING AGENT | | | MATERIAL SAFETY DATA SHEETS REQUIRES AN EMERGENCY | | | SHOWER AND AN EYE WASH STATION. DUE TO THE FACT THAT | | | THIS INFORMATION WAS JUST SUBMITTED, THE DRAWINGS WILL | | | BE SENT TO PLUMBING FORREVIEW. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-02-24 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-02-24 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-02-24 |
Time |
10:43 |
Sent To |
E |
|
| Notes |
| 2007-02-24 13:51:22 | BUILDING PLAN REVIEW | | | PERMIT: | | | ADD: | | | CONT: | | | TEL: (561)###-#### | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2)61G15-23.002(2)EACH SHEET OF PLANS AND PRINTS | | | MUST BE SEALED, SIGNED AND DATED BY THE PROFESSIONAL | | | ENGINEER IN RESPONSIBLE CHARGE.ENGINEERS SHALL | | | LEGIBLY INDICATE THEIR NAME, ADDRESS, AND LICENSE | | | NUMBER ON EACH SHEET.IF PRATICING THROUGH A DULY | | | AUTHORIZED ENGINEERING BUSINESS, ENGINEERS SHALL | | | LEGIBLY INDICATE THEIR NAME AND LICENSE NUMBER, AS WELL | | | AS, THE NAME, ADDRESS, AND CERTIFICATE OF AUTHORIZATION | | | NUMBER OR THE ENGINEERING BUSINESS ON EACH SHEET. | | | | | | 3)INDICATE THE 3' SEPERATION OF THE SPRAY BOOTH ON | | | THE FLOOR PLANS. ALSO STATE THE FIRE RATINGS OF THE TWO | | | IN THE FIRE WALLS. SEE FBC.TABLE 715.3 FOR MORE | | | INFORMATION. | | | | | | 4)106.1.3 THE BUILDING OFFICIAL | | | MAY SET STANDARDS THROUGH DEPARTMENTAL | | | POLICY STANDARDS FOR PLANS AND SPRCIFICA | | | TIONS. "NO HANDWRITING ON DRAWINGS OR SPECIFICATIONS". | | | ONLY THE DESIGNER OF RECORD CAN MAKE CHANGES TO THE | | | PLANS AND SPECIFICATIONS. | | | | | | 5)106.1 INDICATE THE MODEL NO. FOR THE SPRAY BOOTH | | | FROM THE SPECIFICATIONS PROVIDED IN THE PACKAGE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-01-26 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-01-26 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-01-26 |
Time |
08:59 |
Sent To |
E |
|
| Notes |
| 2007-01-26 11:25:22 | BUILDING PLAN REVIEW | | | PERMIT: | | | ADD: | | | CONT: | | | TEL: (561)###-#### | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2)416.2.1THE INTERIOR SURFACES OF SPRAY ROOMS SHALL | | | BE SMOOTH AND SHALL BE SO CONSTRUCTED TO PERMIT THE | | | FREE PASSAGE OF EXHAUST AIR FROM ALL PARTS OF THE | | | INTERIOR AND TO FACILITATE WASHING AND CLEANING, AND | | | SHALL BE SO DESIGNED TO CONFINE RESIDUES WITHIN THE | | | ROOM. ALUMINIUM SHALL BOT BE USED. IF THE BOOTH WILL BE | | | WASHED SHOW HOW IT WILL MEET THE DRAINAGE REQUIREMENT. | | | | | | 3)416.4AN AUTOMATIC FIRE-EXTINGUISHING SYSTEM SHALL | | | BE PROVIDED IN ALL SPRAY, DIP AND IMMERSING SPACES AND | | | STORAGE ROOMS, AND SHALL BE INSTALLED IN ACCORDANCE | | | WITH CHAPTER 9. INDICATE IF THE SYSTEM WILL BE DESIGN | | | TO A) AUTOMIC WATER SPRINKLERS B) DRY CHEMICAL C) HALON | | | 1211 / 1301. | | | | | | 4)61G15-23.002ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME, ADDRESS, AND LICENSE NUMBER ON EACH SHEET. | | | IF PRATICING THROUGH A DULY AUTHORIZED ENGINEERING | | | BUSINESS, ENGINEERS SHALL LEGIBLY INDICATE THEIR NAME | | | AND LICENSE NUMBER, AS WELL AS, THE NAME, ADDRESS, AND | | | CERTIFICATE OF AUTHORIZATION NUMBER OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. A TITLE BLOCK ON EACH SHEET | | | CONTAINING THE PRINTED NAME, ADDRESS, AND LICENSE | | | NUMBER OF THE ENGINEER OR IF APPLICABLE, THE NAME AND | | | LICENSE NUMBER OF THE ENGINEE, AND THE NAME, ADDRESS | | | AND CERTIFICATE OF AUTHORIZATION NUMBER OF THE | | | ENGINEERING BUSINESS WILL SATISFY THIS REQUIREMENT. | | | THIS INFORMATION IS MISSING. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2007-01-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-01-29 |
Time |
10:22 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2007-01-29 |
Time |
10:21 |
Sent To |
PC |
|
| Notes |
| 2007-01-29 10:21:47 | | | | 3/9/07 SPOKE WITH IRV JOHNSON WHO SAID KASPER ELEC. | | | WILL SUBMIT ELEC PLANS./WRT | | | . | | | ELECTRIC APPLIED FOR ON A SEPARATE PERMIT, #06060597 | | | KNIGHT ELEC./WRT. | | | | | | ALSO ELECTRIC PERMIT ISSUED 06060597. KASPER ELECTRIC. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2006-12-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-12-20 |
Time |
09:29 |
Rev Time |
0.25 |
| Received By |
btrobaug |
Date |
2006-12-20 |
Time |
09:26 |
Sent To |
FIRE |
|
| Notes |
| 2006-12-20 09:29:46 | | | | | | | ELECTRIC APPLIED FOR ON A SEPARATE PERMIT, | | | #06060597./WRT. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2007-06-11 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-06-11 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-06-11 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2007-06-11 10:40:05 | *****APPROVED***** | | | | | | | | | REVISON PLAN SHEET STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
F |
Date |
2007-06-06 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-06-06 |
Time |
19:30 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-06-06 |
Time |
19:21 |
Sent To |
M |
|
| Notes |
| 2007-06-06 19:30:00 | *****UNSAT**** | | | | | | | | | PLEASE BE ADVISED THAT THE SUBMITTED PERMIT NUMBER ON | | | THE APPLICATION WAS FOR THE INSTALLATION OF THE PAINT | | | SPRAY BOOTH.ANY REVISIONS TO THE PAINT BOOTH'S | | | SUPPRESSION SYSTEM SHOULD BE UNDER A SEPARATE PERMIT. | | | | | | FEEL FREE TO CONTACT ME IN REGARDS TO THIS MATTER. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-03-27 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-03-27 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-03-27 |
Time |
13:19 |
Sent To |
B |
|
| Notes |
| 2007-03-27 14:11:23 | *****APPROVED***** | | | | | | | | | ALL COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE | | | BEEN ADDRESSED;PLAN SHEET 2 OF 4 WAS STAMPED, | | | INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-02-23 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-02-23 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-02-23 |
Time |
15:55 |
Sent To |
B |
|
| Notes |
| 2007-02-23 16:02:22 | *****UNSAT***** | | | | | | THE FOLLOWING COMMENTS FROM THE PREVIOUS FIRE PLAN | | | REVIEW OF 12/28/2006 STILL NEED TO BE ADDRESSED. ALL | | | OTHER COMMENTS WERE ADDRESSED. | | | | | | | | | | | | | | | 3.INDICATE THE FIRE RATING FOR THE EXISTING DOORS IN | | | THE 1 HOUR RATED WALL. | | | | | | 6.ILLUSTRATE REQUIRED GROUNDING AND BONDING FOR THE | | | BOOTH OR ADD TO NOTES THAT THE BOOTH WILL BE PROPERLY | | | GROUNDED AND BONDED. | | | | | | 7. PROVIDE PRODUCT APPROVAL RATING AND SIZE OF SAFETY | | | STORAGE CABINET. | | | | | | 9.THE FIRE SUPPRESSION SYSTEM FOR THE BOOTH WILL | | | REQUIRE SEPARATE PLANS AND PERMIT. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-12-28 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-12-28 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-12-28 |
Time |
09:52 |
Sent To |
B |
|
| Notes |
| 2006-12-28 10:37:51 | *****UNSAT*****NEED ADDITIONAL INFO | | | | | | | | | | | | 1.PLEASE INDICATE IF THIS A SINGLE TENANT ARRANGEMENT | | | IN THE BUILDING. | | | | | | 2.PROVIDE UL NUMBER AND WALL DETAIL FOR THE 1 HOUR | | | RATED WALL. | | | | | | 3.INDICATE THE FIRE RATING FOR THE EXISTING DOORS IN | | | THE 1 HOUR RATED WALL. | | | | | | 4.WHAT WILL BE THE DIRECTION OF THE PAINT SPRAY | | | VAPORS UPON LEAVING THE PAINT DUCTS? | | | | | | 5.PLEASE INDICATE THE SEPARATION DISTANCE BETWEEN THE | | | INTAKE AND EXHAUST DUCTS.2004 FBC/M 502.7.3.6 | | | | | | 6.ILLUSTRATE REQUIRED GROUNDING AND BONDING FOR THE | | | BOOTH OR ADD TO NOTES THAT THE BOOTH WILL BE PROPERLY | | | GROUNDED AND BONDED. | | | | | | 7. PROVIDE PRODUCT APPROVAL RATING AND SIZE OF SAFETY | | | STORAGE CABINET. | | | | | | 8.FIRE EXTINGUISHER(S) WITH A RATING OF AT LEAST | | | 2A:10BC SHALL BE CERTIFIED AND TAGGED. | | | | | | 9.THE FIRE SUPPRESSION SYSTEM FOR THE BOOTH WILL | | | REQUIRE SEPARATE PLANS AND PERMIT. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-8056722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-05-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-23 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-23 |
Time |
08:38 |
Sent To |
FIRE |
|
| Notes |
| 2007-05-23 08:39:19 | TO "F" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-04-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-12 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-12 |
Time |
16:06 |
Sent To |
P |
|
| Notes |
| 2007-04-12 16:07:17 | TO "P" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-03-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-15 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-15 |
Time |
13:31 |
Sent To |
FIRE |
|
| Notes |
| 2007-03-15 13:32:19 | TO "F" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-02-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-20 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-20 |
Time |
10:02 |
Sent To |
FIRE |
|
| Notes |
| 2007-02-20 10:03:09 | TO "F" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-12-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-28 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-28 |
Time |
11:48 |
Sent To |
B |
|
| Notes |
| 2006-12-28 11:49:12 | TO "MISC" BOX#3 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-12-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-16 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-16 |
Time |
16:27 |
Sent To |
M |
|
| Notes |
| 2006-12-16 16:28:10 | TO "M" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-03-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-03-09 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2006-11-21 |
Time |
15:27 |
Sent To |
PC |
|
| Notes |
| 2006-11-21 15:28:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-07-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2007-07-26 |
Time |
19:23 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2007-07-26 |
Time |
19:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-06-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-06-11 |
Time |
11:24 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-06-11 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2007-06-11 11:26:46 | REVISION TO PAINT BOOTH FIRE SUPPRESSION SYSTEM. | | | | | | NOTE: ADDITIONAL MECH. PERMIT FOR EXHAUST SYSTEM AND | | | FIRE PERMIT FOR FIRE SUPPRESSION REQUIRED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-12-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-12-18 |
Time |
09:30 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-12-18 |
Time |
09:30 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-05-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-05-16 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-04-25 |
Time |
12:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-04-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-04-04 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-04-04 |
Time |
17:33 |
Sent To |
|
|
| Notes |
| 2007-04-04 17:51:01 | DENIED | | | REFERENCE FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | 1. ACCORDING TO THE MSDS SHEETS, AN EYE WASH/EMERGENCY | | | SHOWER IS REQUIRED. SECTIONS 411 & 411.1. | | | | | | 2. SUBMIT A FLOOR PLAN SHOWING THE LOCATION OF THE EYE | | | WASH/EMERGENCY SHOWER. THE EW/SHR SHALL BE LOCATED IN | | | CLOSE PROXIMITY TO THE HAZARD SOURCE. | | | | | | 3. SUBMIT A WATER RISER DIAGRAM SHOWING PIPE SIZE, | | | VALVES & POINT OF CONNECTION. SECTION | | | 106.3.5.1.3(3)(10)(13). | | | | | | 4. EYE WASH/EMERGENCY SHOWER APPROVAL REQUIRED. SUBMIT | | | MANUF. SPECIFICATION SHEETS. ISEA Z358.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-03-28 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-03-28 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-03-28 |
Time |
08:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-12-15 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-12-15 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-12-15 |
Time |
14:53 |
Sent To |
I |
|
| Notes |
|
|