| Plan Review Stops For Permit 06110680 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-02-22 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-02-22 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-02-22 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2007-02-22 15:53:48 | RESTAMP OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-02-02 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2007-02-02 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2007-02-02 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2007-02-02 16:46:15 | LETTER DATED 1/31/07 RECEIVED FROM DIRECTOR OF PUBLIC | | | WORKS APPROVING SPRAY NOZZLE SURFACE DRAINAGE RUN-OFF | | | INTO CITY STORM WATER SYSTEM.PLANS SIGNED OFF BY NEIL | | | MELICK, BUILDING OFFICIAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-01-29 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-01-29 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-01-29 |
Time |
07:24 |
Sent To |
PC |
|
| Notes |
| 2007-01-29 09:39:20 | BUILDING PLAN REVIEW | | | PERMIT: | | | ADD: | | | CONT: | | | TEL: (561)###-#### | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 2ND | | | ACTION: DENIED | | | | | | 1)THE DESCRIPTION ON THE APPLICATION FOR THE WATER | | | PLAYGROUND IS DEFINED IN THE FBC 2004 424.1 AS AN | | | INTERACTIVE WATER FEATURE.?INTERACTIVE WATER | | | FEATURES? MEANS A STRUCTURE DESIGNED TO ALLOW FOR | | | RECREATIONAL ACTIVITIES WITH RECIRCULATED, FILTERED, | | | AND TREATED WATER; BUT HAVING MINIMAL STANDING WATER. | | | WATER FROM THE INTERACTIVE FOUNTAIN TYPE FEATURES IS | | | COLLECTED BY GRAVITY BELOW GRADE IN A COLLECTOR TANK OR | | | SUMP. THE WATER IS FILTERED, DISINFECTED AND THEN | | | PUMPED TO THE FEATURE SPRAY DISCHARGE HEADS. SHOW | | | COMPLIANCE. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-12-30 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-12-30 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-12-30 |
Time |
11:16 |
Sent To |
PC |
|
| Notes |
| 2006-12-30 13:15:04 | BUILDING PLAN REVIEW | | | PERMIT:06110680 | | | ADD:1116 21ST STREET | | | CONT: MUDRAK ENGINEERING & CONSST. | | | TEL: (321)438-1879 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 1ST | | | ACTION: DENIED | | | | | | 1)WHAT TYPE OF FINISH WILL THECONCRETE HAVE TO | | | PREVENT SLIPING AND SLIDING? WILL A DIFFERENT TYPE OF | | | MATERIAL BE USED ON THE SURFACE OF THE CONCRETE TO | | | PREVENT INJURY TO THE PUBLIC. INDICATE THIS INFORMATION | | | ON THE DRAWINGS. | | | | | | 2)SHOW THE ACCESSIBILITY PATH OF TRAVEL TO THIS AREA. | | | FBC. 11-4.1.6(2) | | | | | | 3)FBC.424.1 INTERACTIVE WATER FEATURES? MEANS A | | | STRUCTURE DESIGNED TO ALLOW FOR RECREATIONAL ACTIVITIES | | | WITH RECIRCULATED, FILTERED, AND TREATED WATER; BUT | | | HAVING MINIMAL STANDING WATER. WATER FROM THE | | | INTERACTIVE FOUNTAIN TYPE FEATURES IS COLLECTED BY | | | GRAVITY BELOW GRADE IN A COLLECTOR TANK OR SUMP. THE | | | WATER IS FILTERED, DISINFECTED AND THEN PUMPED TO THE | | | FEATURE SPRAY DISCHARGE HEADS. SHOW COMPLIANCE. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-01-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-01-18 |
Time |
16:31 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2007-01-18 |
Time |
16:07 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2006-12-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-12-20 |
Time |
07:20 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-12-13 |
Time |
07:45 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-02-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-02 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-02 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2007-02-02 14:19:06 | TO "MPERSON" DESK/PER "RBROWN" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-01-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-16 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-16 |
Time |
17:28 |
Sent To |
E |
|
| Notes |
| 2007-01-16 17:29:11 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-01-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-08 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-08 |
Time |
10:25 |
Sent To |
Z |
|
| Notes |
| 2007-01-08 10:25:40 | TO "Z" BOX/RESUB/NEW SHEETS ALL TRADES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-12-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-12 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-12 |
Time |
08:33 |
Sent To |
E |
|
| Notes |
| 2006-12-12 08:34:01 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-12-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-21 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2006-11-21 16:57:12 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-02-02 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2007-02-02 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2007-02-02 |
Time |
16:46 |
Sent To |
|
|
| Notes |
| 2007-02-02 16:46:50 | LETTER DATED 1/31/07 RECEIVED FROM DIRECTOR OF PUBLIC | | | WORKS APPROVING SPRAY NOZZLE SURFACE DRAINAGE RUN-OFF | | | INTO CITY STORM WATER SYSTEM.PLANS SIGNED OFF BY NEIL | | | MELICK, BUILDING OFFICIAL. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2007-02-02 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-02-02 |
Time |
14:37 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-02-02 |
Time |
14:37 |
Sent To |
B |
|
| Notes |
| 2007-02-02 14:59:51 | DENIED 3RD TIME | | | REFERENCE: FBC-2004 BUILDING, SECTION 424.1 | | | | | | THE FOLLOWING CORRECTION IS STILL REQUIRED FOR PLUMBING | | | PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. THE PERMIT BEING APPLIED FOR IS DEFINED IN THE | | | FBC-2004 BUILDING SECTION 424.1 AS AN "INTERACTIVE | | | WATER FEATURE" WHICH MEANS A STRUCTURE DESIGNED TO | | | ALLOW FOR RECREATIONAL ACTIVITIES WITH RECIRCULATED, | | | FILTERED, AND TREATED WATER, BUT HAVING MINIMAL | | | STANDING WATER. WATER FROM THE INTERACTIVE FOUNTAIN | | | TYPE FEATURES IS COLLECTED BY GRAVITY BELOW GRADE IN A | | | COLLECTOR TANK OR SUMP. THE WATER IS FILTERED, | | | DISINFECTED AND THEN PUMPED TO THE FEATURE DISCHARGE | | | HEADS. THE SUBMITTED DRAWINGS INDICATE THE WATER BEING | | | CONTINUOUSLY FED TO THE WATER FEATURES WITHOUT ANY | | | TREATMENT AND IS A TREMENDOUS WASTE OF WATER. NOTE: | | | YOUR RESPONSE LETTER STATES "THIS PLAYGROUND IS DEFINED | | | AS A DRAIN-AWAY SYSTEM. THE WATER IS USED ONLY ONCE AND | | | DISCHARGED." PLEASE GIVE A FBC-2004 CODE REFERENCE | | | INDICATING THIS IS CODE COMPLIANT ON THE RESUBMITTAL. I | | | COULD NOT FIND IT. AS FOR YOUR REFERENCE TO THIS SAME | | | TYPE OF WATER PLAYGROUND BEING CONSTRUCTED AT GAINES, | | | PHIPPS, AND SOUTH OLIVE PARK FOR THE CITY OF WEST PALM | | | BEACH. THIS MAY BE FACT, BUT THAT WAS WORK FROM THE | | | PAST AND POSSIBLE DIFFERENT CODES. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-01-26 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-01-26 |
Time |
13:38 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-01-26 |
Time |
13:38 |
Sent To |
B |
|
| Notes |
| 2007-01-26 14:18:18 | DENIED 2ND TIME | | | REFERENCE: FBC-2004 PLUMBING AB FBC-2004 BUILDING | | | | | | THE FOLLOWING CORRECTION IS STILL REQUIRED FOR PLUMBING | | | PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. THE PERMIT BEING APPLIED FOR IS DEFINED IN THE | | | FBC-2004 BUILDING SECTION 424.1 AS AN "INTERACTIVE | | | WATER FEATURE" WHICH MEANS A STRUCTURE DESIGNED TO | | | ALLOW FOR RECREATIONAL ACTIVITIES WITH RECIRCULATED, | | | FILTERED, AND TREATED WATER; BUT HAVING MINIMAL | | | STANDING WATER. WATER FROM THE INTERACTIVE FOUNTAIN | | | TYPE FEATURES IS COLLECTED BY GRAVITY BELOW GRADE IN A | | | COLLECTOR TANK OR SUMP. THE WATER IS FILTERED, | | | DISINFECTED AND THEN PUMPED TO THE FEATURE DISCHARGE | | | HEADS. THE SUBMITTED DRAWINGS INDICATE THE WATER BEING | | | CONTINUOUSLY FED TO THE WATER FEATURES WITHOUT ANY | | | TREATMENT AND IS A TREMENDOUS WASTE OF WATER. NOTE: | | | YOUR RESPONSE LETTER STATES "THIS PLAYGROUND IS DEFINED | | | AS A WATER PLAYGROUND AND IS CONSIDERED AS A DRAIN-AWAY | | | SYSTEM. THE WATER IS USED ONLY ONCE AND DISCHARGED." | | | PLEASE GIVE A FBC-2004 CODE REFERENCE INDICATING THIS | | | IS CODE COMPIANT ON THE RESUBMITTAL. I COULD NOT FIND | | | IT. AS FOR YOUR REFERENCE TO THIS SAME TYPE OF WATER | | | PLAYGROUND BEING CONSTRUCTED AT GAINES PARK, PHIPPS | | | PARK AND SOUTH OLIVE PARK FOR THE CITY OF WEST PALM | | | BEACH. THIS MAY BE FACT, BUT THAT WAS WORK FROM THE | | | PAST AND POSSIBLY DIFFERENT CODES. | | | | | | 2. (OK) | | | | | | 3. (OK) | | | | | | THE FOLLOWING IS A NEW COMMENT: | | | | | | 4. PLEASE SEE ATTACHED NOTICE FS 553.80 (2) (B) | | | REGUARDING FOUR (4) TIMES THE FEE. | | | | | | **********IMPORTANT INFORMATION | | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | | TRANSMITTAL LETTER INDICATING HOW EACH | | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-12-22 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-12-22 |
Time |
09:30 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2006-12-22 |
Time |
09:30 |
Sent To |
B |
|
| Notes |
| 2006-12-22 09:44:01 | DENIED | | | REFERENCE: FBC-2004 PLUMBING AND FBC-2004 BUILDING | | | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING | | | PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. THE PERMIT BEING APPLIED FOR IS DEFINED IN THE | | | FBC-2004 BUILDING SECTION 424.1 AS AN "INTERACTIVE | | | WATER FEATURE" MEANS A STRUCTURE DESIGNED TO ALLOW FOR | | | RECREATIONAL ACTIVITIES WITH RECIRCULATED, FILTERED, | | | AND TREATED WATER; BUT HAVING MINIMAL STANDING WATER. | | | WATER FROM THE INTERACTIVE FOUNTAIN TYPE FEATURES IS | | | COLLECTED BYGRAVITY BELOW GRADE IN A COLLECTOR TANK | | | OR SUMP. THE WATER IS FILTERED, DISINFECTED AND THEN | | | PUMPED TO THE FEATURE SPRAY DISCHARGE HEADS. THE | | | SUBMITTED DRAWINGS DO NOT SHOW WATER BEING | | | RECIRCULATED, FILTERED, AND TREATED. THE SUBMITTED | | | DRAWINGS INDICATE THE WATER BEING CONTINUOUSLY FED TO | | | THE WATER FEATURES WITHOUT ANY TREATMENT AND IS A | | | TREMENDOUS WASTE OF WATER. PLEASE RESUBMIT INDICATING | | | COMPLIANCE. | | | | | | 2. ON SHEETS C-3 AND C-5 THE 2 INCH DRAIN LINE MUST | | | DRAIN INTO THE SANITARY SYSTEM NOT THE STORM SYSTEM DUE | | | TO THE UNSANITARY ACCIDENTS RELATED TO CHILDREN. PLEASE | | | CORRECT THIS ON THE RESUBMITTAL. | | | | | | 3. ON SHEET C-6 THE PROPOSED 2 INCH WATER SUPPLY TO | | | THE CONTROLLER MUST INDICATE A REDUCED PRESSURE | | | PRINCIBLE BACKFLOW PREVENTER PER FBC-2004 PLUMBING, | | | SECTION 608.13.2. PLEASE ADD THIS ON THE RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-02-02 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2007-02-02 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2007-02-02 |
Time |
15:05 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-01-12 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2007-01-12 |
Time |
18:00 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2007-01-12 |
Time |
18:00 |
Sent To |
I |
|
| Notes |
| 2007-01-12 18:03:09 | DENIED, | | | 1. THE RE-SUBMITTED PLANS DOES NOT HAVE THE APPROVED | | | SITEPLAN FOR THE PROPOSED WORK IN PACKET. | | | 2. PLEASE PROVIDE A COMPLETE SITEPLAN OF THE PROPPERTY | | | SHOWING THE LOCATION OF THE WATER PLAYGROUND AND | | | EQUIPMENT. | | | 3. SITEPLAN SHOULD BE OF THE COMPLETE PROPERTY WITH | | | ADDRESS OF THE PROPERTY AND DIMENSION OF LOT. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-12-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-12-09 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-12-09 |
Time |
13:43 |
Sent To |
I |
|
| Notes |
|
|