Plan Review Details - Permit 06110577
| Plan Review Stops For Permit 06110577 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-04-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-04-30 |
Time |
06:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-04-30 |
Time |
06:48 |
Sent To |
|
|
| Notes |
| 2007-04-30 06:49:13 | REVISION |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-02-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-02-03 |
Time |
17:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-02-03 |
Time |
17:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-01-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-01-17 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-01-17 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2007-01-17 16:19:27 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | | | | 1.)OPENING 7 SPECIFIES ANCHOR SPACING OF 15IN TOP AND | | | BOTTOM.NOT COMPLIANT FOR 7.5FT SPAN. | | | | | | 2.)OPENING 12 SPECIFIES ANCHOR SPACING OF 10IN TOP | | | AND BOTTOM.C1, TOP CONNECTION, REQUIRES 6IN TOP | | | ANCHOR SPACING. | | | | | | 3.)I HAVE SPOT CHECKED THE ANCHORING.BOTH OPENINGS | | | WHICH I HAVE CHECKED SPECIFIED ANCHORING NOT COMPLIANT | | | WITH THE PRODUCT APPROVAL.PLEASE CHECK ALL OPENINGS | | | AND REVISE AS NECESSARY. | | | | | | 4.)THE ANCHORING CIRCLED ON THE PRODUCT APPROVAL IS | | | FOR -31.2PSF.SEE THE DESIGN PRESSURE CHART WHICH YOU | | | HAVE PROVIDED.SOME OPENINGS HAVE DESIGN PRESSURES | | | WHICH EXCEED -31.2PSF.THOSE OPENINGS REQUIRE | | | ANCHORING FROM THE -47.2 ROW. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-04-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-17 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-17 |
Time |
16:30 |
Sent To |
B |
|
| Notes |
| 2007-04-17 16:31:14 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-02-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-01 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-01 |
Time |
09:48 |
Sent To |
B |
|
| Notes |
| 2007-02-01 09:48:50 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-01-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-01-17 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-11-20 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2006-11-20 08:58:40 | TO "MISC" BOX#1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy