| Plan Review Stops For Permit 06110556 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2008-02-01 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-02-01 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-02-01 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2008-02-01 13:46:37 | REVISION CHANGE BATHROOM LOCATION IN SUITE 'C' OK | | | LM |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2007-08-29 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-08-29 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-08-29 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2007-08-29 15:05:50 | FACADE COLUMN REVISIONS OK LM |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2007-08-16 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-08-16 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-08-16 |
Time |
11:01 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2007-08-09 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-08-09 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-08-09 |
Time |
07:55 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2007-07-16 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-07-16 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-07-16 |
Time |
11:19 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2007-07-12 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-07-12 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-07-12 |
Time |
07:43 |
Sent To |
PC |
|
| Notes |
| 2007-07-12 14:38:30 | BUILDING PLAN REVIEW | | | PERMIT: | | | ADD: | | | CONT: | | | TEL: (561)###-#### | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 5TH | | | ACTION: DENIED | | | | | | 1)THE ENERGY CALCULATION FORMS SUBMITTED IS THE | | | INCORRECT VERSION. SEE FBC. 13-400.3.A METHOD A FORMS. | | | AN ACCURATELY COMPLETED FORM 400A-04R VERSION 2.5 | | | DEMONSTRATING THAT CODE COMPLIANCE HA BEENACHIVED SHALL | | | BE SUBMITTED TO THE BUILDING OFFICIAL. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2007-06-16 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-06-16 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-06-16 |
Time |
13:18 |
Sent To |
Z |
|
| Notes |
| 2007-06-16 14:15:42 | BUILDING PLAN REVIEW | | | PERMIT: 06110556 | | | ADD: 2814 S. DIXIE HWY | | | CONT: KARNS CONST. | | | TEL: (561)805-7528 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 3RD | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2)OK. | | | | | | 3)OK. | | | | | | 4)OK. | | | | | | 5)OK | | | | | | 6)OK | | | | | | 7)FBC. 1210.2 WALLS WITHIN 2 FEET OF WATER CLOSETS | | | SHALL HAVE A SMOOTH, HARD, AND NONABSORBENT SURFACE, TO | | | A HEIGHT OF 4 FEET ABOVE THE FLOOR, AND EXCEPT FOR | | | STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS | | | SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY | | | MOISTURE. PAINT ON DRYWALL IS NOT A HARD SURFACE. | | | | | | 8)OK | | | | | | 9)OK. | | | | | | 10) OK | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-05-09 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-05-09 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-05-08 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2007-05-08 12:48:24 | BUILDING PLAN REVIEW | | | PERMIT: 06110556 | | | ADD: 2814 S. DIXIE HWY | | | CONT: KARNS CONST. | | | TEL: (561)805-7528 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 3RD | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2)OK. | | | | | | 3)OK. | | | | | | 4)OK. | | | | | | 5)WHEN RESUBMITTING, HAVE THE FRONT COUNTER STAFF | | | ADJUST THE VALUE OF THE PROJECT AND PAY THE ADDITIONAL | | | FEES ACCORDINGLY. | | | | | | 6)SEE INFORMATION ABOUT THE CONSTRUCTION OF THE | | | DUMPSTER ENCLOSURE IN THE PACKAGE AND FOLLOW THOSE | | | GUIDELINES. DUMPSTER ENCLOSURE MUST HAVE MINIMUM OF | | | 12'-6" OPENING BETWEEN THE GATE POSTS. ON SHEET 2 | | | INDICATE ALL DIMENTIONS FOR THE DUMPSTER ENCLOSURE. | | | | | | 7)FBC. 1210.2 WALLS WITHIN 2 FEET OF WATER CLOSETS | | | SHALL HAVE A SMOOTH, HARD, AND NONABSORBENT SURFACE, TO | | | A HEIGHT OF 4 FEET ABOVE THE FLOOR, AND EXCEPT FOR | | | STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS | | | SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY | | | MOISTURE. PAINT IS NOT HARD. | | | | | | 8)THE PLANS INDICATE IMPACT GLASS, HOWEVER, THE | | | PRODUCT APPROVALS IS FOR NON-IMPACT GLASS. CLARIFY. | | | PROVIDE THE CORRECT INFORMATION FOR THE STOREFRONT | | | GLASS. | | | | | | 9)OK. | | | | | | 10)IF THE SIDEWALK WILL BE ALTERED THE PLANS SHALL BE | | | REVIEW BY THE ENGINEERING DEPARTMENT. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-03-24 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-03-24 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-03-24 |
Time |
13:06 |
Sent To |
PC |
|
| Notes |
| 2007-03-24 13:06:58 | BUILDING PLAN REVIEW | | | PERMIT: 06110556 | | | ADD: 2814 S.DIXIE HWY #105 | | | CONT: KARNS CONST. CORP. | | | TEL: (561)805-7528 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 2ND | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2)FBC. 106.3.5THE EXAMINATION OF THE DOCUMENTS BY | | | THE BUILDING OFFICIAL SHALL INCLUDE THE FOLLOWING | | | MINIMUM CRITERIA AND DOCUMENTS: A FLOOR PLAN; SITE | | | PLAN; FOUNDATION PLAN; FLOOR/LAYOUT;AND ALL EXTERIOR | | | ELEVATIONS WITH THE ACCESSIBLE ROUTE TO EACH UNIT IN | | | COMPLIANCE WITH FBC. 11-4.3. | | | | | | 3)106.1.1W.P.B. ADMINISTRATIVE CODE CONSTRUCTION | | | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE | | | THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED | | | AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE. | | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN | | | THE FORM OF NOTES OR | | | OTHERWISE, AS TO THE QUALITY OF MATERIALS, WHERE | | | QUALITY IS ESSENTIAL TO CONFORMITY WITH THE TECHNICAL | | | CODES. | | | SUCH INFORMATION SHALL BE SPECIFIC | | | AND THE TECHNICAL CODES "SHALL NOT BE | | | CITED AS A WHOLE OR IN PART, NOR THE | | | TERM "LEGAL" OR ITS RQUIVALENT BE USED | | | AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION". | | | | | | 4)IF THE NEW 4" CONCRETE SLAB IS CONSTRUCTED AT EACH | | | DOOR HOW DOES EACH ENTRANCE COMPLY WITH THE | | | ACCESSIBILITY CODE? SHOW COMPLIANCE. SEE 2004 FBC. FIG | | | 11 AND 12 OF CH. 11.SHEET 1 SHOWS THE ACCESSIBLE | | | ROUTE TO SUITE 'A' ONLY WHAT ABOUT THE OTHER SUITES? | | | ALSO FBC. 11-4.8.1 ANY PARTOF AN ACCESSIBLE ROUTE WITH | | | A SLOPE GREATER THAN 1:20 SHALL BE CONSIDERED A RAME | | | AND SHALL COMPLY WITH SECTION 11-4.8. | | | | | | 5)WHEN RESUBMITING, HAVE THE FRONT COUNTER STAFF | | | ADJUST THE VALUE OF THE PROJECT AND PAY THE ADDITIOINAL | | | FEES ACCORDINGLY. FOR MORE INFORMATION SEE WPB. | | | AMENDMENTS 108.3. | | | | | | 6)SEE INFORMATION ABOUT THE CONSTRUCTION OF THE | | | DUMPSTER ENCLOSURE IN THE PACKAGE AND FOLLOW THOSE | | | GUIDELINES. | | | | | | 7)FBC. 1210.2 WALLS WITHIN 2 FEET OF WATER CLOSETS | | | SHALL HAVE A SMOOTH, HARD, AND NONABLORBENT SURFACE, TO | | | A HEIGHT OF 4 FEET ABOVE THE FLOOR, AND EXCEPT FOR | | | STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS | | | SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY | | | MOISTURE. | | | | | | 8)ALL THE PRODUCT APPROVALS SUBMITTED SHALL BE | | | APPROVED IN WRITING "(NO PHOTO-COPIES ALLOWED)" BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL.THE ONES | | | SUBMITTED ARE PHOTOCOPIES. WPB.AMENDMENTS 106.3.3. | | | | | | 9)ALL PAGES SUBMITTED SHALL BE SIGNED, DATED AND SEAL | | | BY THE ARCHITECT OR ENGINEER IN RESPONSIBLE CHARGE. SEE | | | F.A.C. 61G15-23.002 AND 61G1-16.004 / 471.025. FOR MORE | | | INFORMATION. THE MECHINICAL SHEETS (M-1) HAS A | | | CORPORATE SEAL. THIS SEAL HAS NO BEARING ON THE | | | DRAWINGS. SHEET (M-2) IS NOT SEAL. NOTE ALL SIGNATURES | | | SHALL BE ORIGINAL. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-12-21 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-12-21 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-12-21 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2006-12-21 11:44:29 | BUILDING PLAN REVIEW | | | PERMIT: 06110556 | | | ADD: 2814 S. DIXIE HWY. | | | CONT: KARNS CONSTRUCTION CORP. | | | TEL: (561)805-7528 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW1ST. | | | ACTION: DENIED | | | | | | NOTE: ANY OTHER OCCUPANCY OTHER THAN WHAT IS STATED BY | | | THE DESIGNER OF RECORD SHALL REQUIRE A SEPERATE | | | PERMIT. | | | | | | 1) 106.3.3* PRODUCT APPROVALS- 2004 | | | THOSE PRODUCTS THAT ARE RGULATED BY DCA. RULE 9B-72 | | | SHALL BE REVIEWED AND APPROVED IN WRITTING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. SUBMIT PRODUCT APPROVALS FOR | | | THE IMPACT WINDOWS/DOORS/ROOF AND STOREFRONT. | | | | | | 2)W.P.B. AMENDMENTS 108.3*IF IN THE OPINION OF THE | | | BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING,ALTERATION APPEARS TO BE UNDERESTIMATED ON THE | | | APPLICATION, THE PERMIT SHALL BE DENIED. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | | TOTAL REPLACEMENT VALUE TO INCLUDE | | | STRUCTURAL,ELECTRIC,PLUMBING,MECHANICAL,INTERIOR | | | FINISH,ARCHITECTURAL AND DESIGN FEES,MARKETING COSTS, | | | AND OVERHEAD AND PROFIT. OUR VALUATION REFERENCE IS ICC | | | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS | | | SERVICES. | | | | | | 3)SHEET #1. IN REFERENCE TO THE DUMPSTER PAD, SEE | | | REQUIREMENTS DETAILS IN PACKAGE AND COMPLY | | | ACCORDINGLY. | | | | | | 4) FBC 11-4.3 SHOW THE ACCESSIBLE ROUTE TO THE BUILDING | | | COMPLYING WITH THIS SECTION. | | | | | | 5)SHEET #2. THE CODE SECTION ON THE DRAWINGS IN | | | REFERENCE TO ROOF DOWNSPOUTS IS FROM THE 2001 FBC. SEE | | | FBC 2004 FOR CORRECT REFERENCE. | | | | | | 6)FBC 1503.4 UNLESS ROOF ARE SLOPED TO DRAIN OVER | | | ROOF EDGES, DESIGN AND INSTALLATION OF ROOF DRAINAGE | | | SYSTEMS SHALL COMPLY WITH THE FBC PLUMBING CH. 11. | | | | | | 7)1503.4.3 | | | WHEN OTHER MEANS OF DRAINAGE OF OVERFLOW WATER IS NOT | | | PROVIDED, OVERFLOW SCUPPERS SHALL BE PLACED IN WALLS OR | | | PARAPETS NOT LESS THAN 2 INCHES (51 MM) NOR MORE THAN 4 | | | INCHES (102 MM) ABOVE THE FINISHED ROOF COVERING AND | | | SHALL BE LOCATED AS CLOSE AS PRACTICAL TO REQUIRED | | | VERTICAL LEADERS OR DOWNSPOUTS OR WALL AND PARAPET | | | SCUPPERS. AN OVERFLOW SCUPPER SHALL BE SIZED IN | | | ACCORDANCE WITH THE FLORIDA BUILDING CODE, PLUMBING. | | | | | | | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
P |
Date |
2008-02-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-02-29 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-02-29 |
Time |
12:38 |
Sent To |
PC |
|
| Notes |
| 2008-02-29 12:38:51 | REVISED VALUE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2008-01-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-01-22 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-01-22 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2008-01-22 09:03:31 | VALUATION FOR COMPLETE SCOPE OF WORK FROM ORIGINAL | | | APPLIED SCOPE PF WORK TO BE INCREASED PER FBC 108.3. | | | PASSED PENDING. | | | SPOKE TO GRACE FROM KARNSCONSTRUCTION AND SHE WILL | | | GET INFORMATION FOR FINAL UPGRADE OF VALUATION. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2007-07-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-07-16 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-07-16 |
Time |
10:10 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2007-07-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-07-06 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-07-06 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2007-07-06 18:21:45 | 2007-07-06 18:21:45 | | | NOTE ADDED: | | | | | | *** PLEASE KNOW , NO FURTHER ELECTRICAL REVIEWS OF | | | ENERGY CALCULATIONS WILL BE DONE UNTIL A MEETING IS | | | HELD WITH THE DESIGNERS OF RECORD. THESE NOTES WILL | | | NEED TO BE GONE OVER AT THAT TIME TO ALLEAVIATE ANY | | | QUESTIONS, COMMENTS OR CONFUSION OF ANYKIND. | | 2007-07-06 16:43:50 | 2007-07-06 18:21:45 | | | NOTE ADDED: | | | | | | *** PLEASE KNOW , NO FURTHER ELECTRICAL REVIEWS OF | | | ENERGY CALCULATIONS WILL BE DONE UNTIL A MEETING IS | | | HELD WITH THE DESIGNERS OF RECORD. THESE NOTES WILL | | | NEED TO BE GONE OVER AT THAT TIME TO ALLEVIATE ANY | | | QUESTIONS, COMMENTS OR CONFUSION OF ANYKIND. | | | THIS WAS CONFIRMED WITH THE ASSISTANT BUILDING OFFICIAL | | | AFTER REVIEW OF SAID ENERGY CALCULATIONS. | | | | | | | | | | | | | | | | | | 2007-07-06 16:43:50 | | | ** UNSAT 6TH REVIEW ** | | | | | | | | | 1) NOTE: PLEASE SEE NOTES DATED 6/29/07 WHICH STATED | | | THIS OFFICE WAS GOING TO PLACE REVIEW INTO A *TEMPORARY | | | FAILED STATUS*. THIS WAS TO ALLOW REVISED CORRECTED | | | ENERGY CALCULATIONS TO BE BROUGHT IN AS A SUBMITTAL | | | UNDER THE CORRECT VERSION AS LONG AS NO CHANGES WERE | | | MADE TO THE CALCULATIONS THEMSELVES. | | | ON TUESDAY JULY 3RD 2007 REVISED ENERGY CALCULATIONS | | | WERE BROUGHT IN AS A SUBMITTAL TO THIS OFFICE. UPON A | | | QUICK GLANCE TO THE CALCULATIONS IT WAS NOTICED THE | | | VERSION WAS NOW STATED UNDER JULY 05 2.0 VERSION WHICH | | | WAS BEFORE THE PREVIOUS CODE CHANGE. (PLEASE SEE THE | | | FBC CHANGED AS OF OCT 1ST, 2005 OF THAT YEAR). THIS | | | REVIEWER PLACED CALL TO THE ARCHITECT OF RECORD | | | NOTIFYING OF THE INCORRECT VERSION. WE THEN CALLED THE | | | PERSON WHICH WAS PROVIDING THE CALCULATIONS. | | | THIS OFFICE SPECIFICALLY INFORMED BOTH DESIGNERS THAT | | | THE ENERGY CALCULATIONS NUMBERS WERE OK, HOWEVER NEEDED | | | TO BE UNDER THE 2.1 VERSION AS PREVIOUSLY STATED IN THE | | | REVIEWS. | | | THIS OFFICE WAS INFORMED THAT REVISED ENERGY | | | CALCULATIONS WITH THE CORRECT VERSION WOULD BE | | | SUBMITTED BY 7/06/07. | | | PLEASE SEE NEW ENERGY CALCULATIONS WERE ONCE AGAIN | | | BROUGHT IN BY THE PERMIT EXPEDITOR AS A SUBMITTAL AND | | | NO FEE WAS CHARGED ON 7/06/07. | | | PLEASE SEE THIS TIME THE VERSION WAS CORRECT HOWEVER | | | THE NUMBERS IN THE ENERGY CALCULATIONS WHICH WERE OK ON | | | THE PREVIOUS CALCULATIONS HAVE ONCE AGAIN BEEN CHANGED | | | AND DO NOT MATCH AND CORRELATE WITH PLANS. | | | PLEASE SEE 13-415.1.A, 13-415.2 | | | | | | ** THIS REVIEW IS DENIED, ONE COPY OF EACH THE | | | SUBMITTED ENERGY CALCULATIONS ARE BEING RETAINED BY | | | THIS OFFICE. | | | | | | AS STATED ON PREVIOUS REVIEWS: PLEASE CORRELATE THE | | | ENERGY CALCULATIONS WITH THE PLANS. PLEASE TAKE THE | | | CALCULATIONS FOR ELECTRICAL LIGHTING FROM THE VERSION | | | 3.0 WHICH WAS SUBMITTED AND TRANSFER THAT INFORMATION | | | INTO THE CORRECT VERSION OF 2.1. | | | THE NUMBER OF LUMINARIES, THE WATTAGE OF LUMINARIES | | | | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2007-06-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-29 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-29 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2007-06-29 15:45:42 | *** TEMPORARY FAILED*** | | | | | | 1) NOTE: THENEW ENERGY CALCULATIONS ARE NOW SUBMITTED | | | UNDER A VERSION IN WHICHWAS NOT IN EFFECT AT THE TIME | | | OF PERMIT APPLICAYION.THE VERSION SHOULD BE THAT OF THE | | | 2004 FBC WITH THE *2005* REVISIONS. (2.1). | | | THIS REVIEWER HAS CALLED THE ARCHITECT AND NEW ENERGY | | | CALCULATIONS ARE TO BE BROUGHT IN AS A SUBMITTAL TO DV | | | PALMER. THE CALCULATIONS AND NUMBERSFOR ELECTRICAL ARE | | | OK. | | | | | | ELECTRICAL PLANS ARE OK AND HAVE BEEN STAMPED. ONLY | | | NEED TO ADDRESS THE ENERGY CALCULATIONS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-06-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-10 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-10 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2007-06-10 11:57:32 | ** UNSAT 4TH REVIEW ** | | | | | | | | | 1) NOTE: PLEASE SEE ENERGY CALCULATIONS SUBMITTED ARE | | | SIGNED BY THE ARCHITECT, HOWEVER WAS INADVERTENTLY NOT | | | SEALED AS NEEDED. | | | PLEASE SEE ONLY ONE INPUT DATA REPORT WAS SUBMITTED. | | | PLEASE SEE THE TOTAL AMOUNT OF FIXTURES, TYPES, AND | | | WATTAGES DOES NOT MATCH PLANS. | | | PLEASE SEE UNIT E FOR EXAMPLE> | | | PLANS INDICATE RETAIL AS A TOTAL OF 11 FIXTURES, YET | | | PLANS DO NOT INDICATE THE SAME AMOUNT OF FIXTURES ON | | | THE PLANS. | | | PLEASE SEE FIXTURE A, A TOTAL OF 7 OF THESE ARE ON | | | PLANS, EACH OF THESE PER FIXTURE LEGEND IS 128WATTS. | | | PLANS INDICATE A TOTAL OF 2-TYPE C WHICH ARE 32 WATTS | | | EACH ON FIXTURE LEGEND. | | | PLEASE SEE OFFICE AREA AS THE PLANS CALL FOR THIS | | | FIXTURE AS 2-TYPE B EACH CONTAINING 3-32WATT BULBS AT A | | | TOTAL OF 96WATTS, YET THE CALCULATIONS SHOWS 64WATTS. | | | PLEASE SEE THE FIXTURE SCHEDULE WHICH CONTAINS FIXTURES | | | WITH A DIFFERENT WATTAGE FOR THE SAME FIXTURES AS NOTED | | | ON CALCULATIONS. | | | UNIT ?E. | | | 7- A FIXTURES 128W EACH | | | 2-C FIXTURES 26 W EACH | | | 2-B FIXTURES 96W EACH. | | | THE OTHER EXTERIOR LIGHT FIXTURES ARE: | | | 2- D FIXTURES 26W EACH | | | 1- E FIXTURE 26W. | | | THE NUMBER OF FIXTURES SHOWN ON EXTERIOR INPUT DATA | | | REPORT IS OK, ONLY NEED TO UPDATE THE WATTAGE FOR D | | | FIXTURES. | | | | | | OTHER UNITS CONTAIN A DIFFERENT NUMBER OF FIXTURES, | | | HOWEVER THE SAME COORDINATION NEEDS TO TAKE PLACE. | | | | | | ** PLEASE CALL THIS OFFICE TO GO OVER THIS OR IF THERE | | | ARE ANY QUESTIONS OR COMMENTS IN ANY WAY AS STATED ON | | | THE PREVIOUS THREE REVIEWS. | | | | | | 2) NOTE: PLEASE SEE OWNER INFORMATION ON PERMIT | | | APPLICATION DOES NOT SHOW THE SAME AS ON OUR SYSTEM. | | | PLEASE OBTAIN UPDATED DEED, OR PALM BEACH COUNTY | | | PROPERTY APPRAISER PRINT OUTS SO THE OWNER INFORMATION | | | CAN BE UPDATED. | | | *THIS IS NOT FOR ELECTRICAL CODE COMPLIANCE, HOWEVER | | | THIS IS STILL REQUIRED. | | | | | | 3) NOTE: PLEASE KNOW AS A NEW DESIGNER OF RECORD HAS | | | TAKEN OVER FOR THE ENERGY CALCULATIONS, FS 553.80(2)(B) | | | DOES NOT APPLY AT THIS TIME. | | | PLEASE BE SURE TO ADDRESS COMMENT. | | | | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-04-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-04-24 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-04-24 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2007-04-24 15:57:44 | | | | *** UNSAT 3RD REVIEW *** | | | | | | ** PLEASE NOTE, ALL REVIEWS WILL ONLY BE DONE UNDER | | | PERMIT # 06110556. | | | THE OTHER FOUR PREVIOUS ADDITIONAL PERMIT NUMBERS ARE | | | NO LONGER IN-USE. | | | | | | | | | 1) NOTE: PLEASE CORRELATE ELECTRICAL LIGHTING PLANS | | | WITH THE ENERGY CALCULATIONS SUBMITTED. PLEASE SEE THE | | | NUMBER OF FIXTURES; THE WATTAGE PER FIXTURE AND THE | | | TOTAL DO NOT CORRELATE WITH THAT OF THE FIXTURES AND | | | LIGHTING ON PLANS. | | | PLEASE SEE THE ENERGY CALCULATIONS SUBMITTED AS THERE | | | IS NOW NO INTERIOR LIGHTING SUBMITTED AND SHOWN IN THE | | | INPUT DATA REPORT IN EITHER SET SUBMITTED. | | | PLEASE SEE THE FIXTURES NOW ENTERED FOR EXTERIOR | | | LIGHTING DOES NOT CORRELATE WITH PLANS OR THE TYPES OF | | | FIXTURES ON PLANS. | | | 13-415.1.AB.1.1, 13-415.2 ETC. | | | | | | 2) NOTE: PLEASE SEE FBC 103.1, 103.1.1.1 AS THE ENERGY | | | CALCULATIONS MUST BE SIGNED, DATED AND SEALED BY THE | | | DESIGN PROFESSIONALS. SHEETS CONTAIN SOME PRINTED | | | INFORMATION AND SOME SIGNATURES, HOWEVER THE DESIGNER | | | OF RECORD HAS NOT SIGNED AND SEALED SHEETS REQUIRED. | | | | | | 3) NOTE: PLEASE SEE THAT THE COMMENTS FOR THE ENERGY | | | CALCULATION ARE REPEATED FROM THE 2ND REVIEW. | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-03-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-10 |
Time |
18:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-10 |
Time |
18:16 |
Sent To |
|
|
| Notes |
| 2007-03-10 18:16:45 | ** UNSAT 2ND REVIEW ** | | | | | | | | | 1) NOTE: PLEASE CORRELATE ELECTRICAL LIGHTING PLANS | | | WITH THE ENERGY CALCULATIONS SUBMITTED. PLEASE SEE THE | | | NUMBER OF FIXTURES; THE WATTAGE PER FIXTURE AND THE | | | TOTAL DO NOT CORRELATE WITH THAT OF THE FIXTURES AND | | | LIGHTING ON PLANS. | | | PLEASE SEE THE ENERGY CALCULATIONS DO NOT INDICATE AN | | | EXTERIOR LIGHTING, YET THE PLANS INDICATE EXTERIOR | | | LIGHTING. | | | 13-415.1.AB.1.1 | | | 13-415.2 | | | | | | 2) NOTE: PLEASE SEE FBC 103.1, 103.1.1.1 AS THE ENERGY | | | CALCULATIONS MUST BE SIGNED, DATED AND SEALED BY THE | | | DESIGN PROFESSIONAL EVEN WHEN/IF FALLING UNDER THE | | | EXCEPTIONS THAT A MECHANICAL CONTRACTOR PERFORMS THE | | | SCOPE OF WORK. | | | PLEASE KNOW THE SCOPE DOES NOT APPEAR TO FALL UNDER THE | | | EXCEPTIONS UNDER FS 471.003. | | | ** PLEASE ALSO SEE THE MECHANICAL PLANS WHICH CONTAIN | | | TITLE BLOCKS FROM AN ENGINEER AND ENGINEERING FIRM, YET | | | THERE IS A SIGNATURE AND SEAL ON THESE SHEETS FROM A | | | MECHANICAL CONTRACTOR. THIS IS NOT PERMITTED UNDER | | | FLORIDA STATUTES 471.025 AND FLORIDA ADMINISTRATIVE | | | CODE 61G15-23.002 | | | PLEASE ALSO SEE THE 2ND MECHANICAL SHEET IN EACH SET | | | DOES NOT CONTAIN ANY SIGNATURE, DATE OR SEAL FROM | | | ANYONE. | | | | | | 3) NOTE: PLEASE KNOW DUE TO THE COMMENTS ONE SET OF | | | PLANS AND ENERGY CALCULATIONS WILL BE RETAINED BY THIS | | | OFFICE. | | | **PLEASE BE SURE RE-PRINT THE 2ND SET OF ELECTRICAL. AS | | | PLUMBING IS ON THE SAME SHEET WITH ELECTRICAL, PLUMBING | | | WILL NEED TO RE-STAMP SHEETS IN SETS WHEN PLANS ARE | | | CORRECTED AND RESUBMITTED. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-12-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-07 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-07 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2006-12-07 08:51:44 | *** UNSAT *** | | | | | | 1) NOTE:PLEASE SEE LOADS FOR SHOW WINDOWS NEED TO BE | | | CLARIFIED PER 220.12A. PLEASE SEE AS THE VA IS NOT | | | SHOWN AND NO LOAD SUMMARY IS SHOWN, THE VA PER FOOT CAN | | | NOT BE VERIFIED. | | | 210.62 | | | | | | 2) NOTE: PLEASE VERIFY THE LOAD SHOWN FOR THE SIGN | | | CIRCUIT(S). PLEASE SEE 600.5, WHICH REFERENCES TO | | | 220.3B6 FOR THE MINIMUM VA TO USE TO FIGURE FOR SIGN | | | CIRCUITS. PLEASE SEE THE LOAD OF 5A?S FOR EACH DOES NOT | | | CORRELATE TO THE MINIMUM VA REQUIRED. | | | PLEASE SEE NO LOAD SUMMARY IS SHOWN TO VERIFY THIS. | | | | | | 3) NOTE: PLEASE CORRELATE LOADS ON PANEL FOR KNOWN | | | RECEPTS ON A CIRCUIT. 220.13 | | | | | | 4) NOTE: PLEASE SEE A NOTE ON "E" UNIT INDICATES | | | RECEPTACLE ABOVE CEILING AS TYPICAL FOR EACH SIGN | | | CIRCUIT. PLEASE SEE 600.5, AS IT ONLY REQUIRES A | | | CIRCUIT. PLEASE SEE 400.8(2) WHICH DO NOT PERMIT | | | RECEPTACLES ABOVE CEILINGS AS THIS WOULD THEN CREATE | | | THE ISSUE OF CORDS BEING RUN THROUGH CEILINGS WHICH IS | | | NOT PERMITTED. | | | PLEASE REVISE. | | | | | | 5) NOTE: PLEASE CLARIFY THE GROUNDING ELECTRODE SYSTEM | | | AS SHOWN. RISER SHOWS THE MAIN GROUNDING ELECTRODE | | | BEING "TAPPED" AND SHOWN TO EACH MAIN DISCONNECT?? | | | PLEASE SEE 250.24B, 250.6. PLEASE KNOW WHEN INSTALLING | | | THE GUTTER, THE NEUTRAL CONDUCTOR WOULD BE "BONDED" TO | | | THE GUTTER WHICH MAY CONTAIN THE SOLE CONNECTION OF THE | | | GEC. PLEASE SEE ONLY ONE SET OF PHASE AND NEUTRAL | | | CONDUCTORS WOULD THEN BE ROUTED TO EACH METER AND MAIN. | | | EACH NEUTRAL WOULD BE BONDED TO THE ENCLOSURE AT THE | | | FIRST MEANS OF DISCONNECT. | | | PLEASE SEE AS SHOWN THIS SEEM TO BE AN INTERESTING | | | SCENARIO AT THE CONNECTION POINT SHOWN AT THE GROUND | | | LEVEL LOCATION. | | | ** PLEASE SEE THIS BEING AN EXISTING BUILDING AND THE | | | CONCRETE ENCASED ELECTRODE ON AN EXISTING BUILDING IS | | | NOT REQUIRED TO BE ATTACHED. PLEASE KNOW IF SHOWN ON | | | GROUNDING ELECTRODE DETAIL BEING REQUIRED THEN THIS | | | WILL BE REQUIRED IN THE FIELD. PLEASE VERIFY THIS BEING | | | REQUIRED AND POSSIBLY AFFECTING THE STRUCTURAL | | | INTEGRITY OF THE EXISTING FOOTER. | | | | | | 6) NOTE: PLEASE LIST THE FOLLOWING RELEVANT CODES ON | | | THE PLANS. 2002 NFPA-70, 2003 NFPA-101 | | | | | | 7) NOTE: PLEASE CORRELATE LOADS, OVER CURRENT | | | PROTECTION, CONDUCTORS ETC FOR THE A/C SYSTEMS. PLEASE | | | SEE ELECTRICAL PLANS SEEM TO INDICATE A POSSIBLE 5KW | | | LOAD, HOWEVER AS KW RATINGS/ KVA LOADS ARE NOT SHOWN, | | | THESE ARE UNCLEAR AT THIS TIME. PLEASE SEE MECHANICAL | | | PLANS CALL FOR 8KW AND 10KW UNITS. | | | PLEASE SEE 424.3B, 310.16, 240.4 ETC | | | FBC 106.1.2 ADMIN SECTION. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2008-01-28 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-01-28 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-01-28 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2008-01-28 09:53:31 | *****REVISION APPROVED***** | | | | | | | | | REVISED PLAN SHEETS 1 & 4 WERE STAMPED, INITIALED, AND | | | DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2007-07-09 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-07-09 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-07-09 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2007-07-09 11:21:39 | *****APPROVED***** | | | | | | | | | PLAN SHEETS 1, 2, & 4 WERE STAMPED, INITIALED AND | | | DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-06-12 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-06-12 |
Time |
17:21 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-06-12 |
Time |
17:16 |
Sent To |
|
|
| Notes |
| 2007-06-12 17:18:41 | *****PROVISO***** | | | | | | | | | THE APPROPIATE PLAN SHEET(S) TO BE STAMPED WHEN ALL | | | OTHER PLAN REVIEWERS HAVE BEEN SATISFIED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-05-10 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-05-10 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-05-10 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2007-05-10 16:40:13 | *****PROVISO***** | | | | | | ALL COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADDRESSED;HOWEVER THE APPROPIATE PLAN SHEET(S) | | | WILL BE STAMPED WHEN ALL REVIEWERS HAVE BEEN SATISFIED | | | | | | | | | | | | | | | | | | CAPT. MICHEAL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-12-12 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-12-12 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-12-12 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2006-12-12 16:16:12 | *****DENIED***** | | | | | | | | | | | | 1.NFPA 101 (2003 EDITION) AND THE FLORIDA FIRE | | | PREVENTION CODE (2004 EDITION) SHALL BE REFERENCED. | | | | | | 2.CONSTRUCTION, ALTERATION, OR DEMOLITION OPERATIONS | | | SHALL COMPLY WITH NFPA 241. | | | | | | 3.COMBUSTIBLE WASTE, DUST, AND DEBRIS SHALL BE | | | REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR MORE | | | FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | | | 4.CONSTRUCTION AND/OR DEMOLITION OPERATIONS SHALL NOT | | | INTERFERE OR HINDER EMERGENCY ACCESS TO THE SAID | | | PROPERTY OR VICINITY THEREOF (INCLUDING FIRE LANES). | | | | | | 5.GASOLINE POWERED EQUIPMENT FOR DEMOLITION | | | ACTIVITIES SHALL NOT BE USED TO PREVENTTHE | | | POSSIBILITY OF CARBON DIOXIDE POISONING. | | | | | | 6.SHOW/DISPLAY THE ADDRESS OF THE STRUCTURE ON THE | | | EXTERIOR ELEVATION WHICH FRONTS SOUTH DIXIE HIGHWAY. AS | | | PER WEST PALM BEACH CODE, THE NUMERICAL ADDRESS SHALL | | | BE NO LESS THAN 6' IN HEIGHT AND 1" IN WIDTH. | | | ADDITIONALLY, DISPLAY THE UNIT NUMBER (3" IN HEIGHT AND | | | 1" IN WIDTH) FOR THE FRONT ENTRANCE TO DISTINGUISH ONE | | | UNIT FROM THE OTHER. FRONT UNIT NUMBERS SHALL NOT BE ON | | | THE DOORS OR WINDOWS, HOWEVER REAR UNIT NUMBER CAN BE | | | INSTALLED ON THE DOOR.HURRICANE SHUTTERS SHALL NOT | | | BLOCK VISIBILITY OF BUILDING AND/OR UNIT ADDRESS. | | | | | | 7.INTERIOR FINISH CLASSIFICATION IN AN UNSPRINKLERED | | | BUILDING SHALL BE "A" OR "B". | | | | | | 8.FIRE EXTINGUISHERS TO BE 2A:10BC RATED. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | SHEET INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED. | | | | | | CAPT. MICHEAL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2008-01-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-30 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-30 |
Time |
12:07 |
Sent To |
M |
|
| Notes |
| 2008-01-30 12:07:39 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2008-01-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-18 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-18 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2008-01-18 10:47:02 | TO "BOB"#4 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-12-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-19 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-19 |
Time |
09:32 |
Sent To |
M |
|
| Notes |
| 2007-12-19 09:33:11 | TO "TGORDON" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-12-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-13 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-13 |
Time |
09:26 |
Sent To |
B |
|
| Notes |
| 2007-12-13 09:27:26 | TO "MJACOBS" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-11-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-21 |
Time |
08:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-21 |
Time |
08:11 |
Sent To |
M |
|
| Notes |
| 2007-11-21 08:11:23 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-10-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-30 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-30 |
Time |
11:36 |
Sent To |
M |
|
| Notes |
| 2007-10-30 11:36:25 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-08-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-09 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-09 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2007-08-16 08:41:51 | SENT TO ERIC SCHNEIDER | | 2007-08-09 13:27:13 | WAITING FOR COMM BOARD. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
|
Date |
2007-08-08 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2007-08-08 |
Time |
18:17 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2007-08-08 |
Time |
18:16 |
Sent To |
B |
|
| Notes |
| 2007-08-08 18:17:00 | SENT TO MYRON JACOB'S DESK MMILLER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-07-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-13 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-13 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2007-07-13 16:08:49 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-06-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-27 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-27 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2007-07-06 07:29:40 | ON BOB BOARD#1 | | 2007-06-27 10:48:56 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-06-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-05 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-05 |
Time |
13:25 |
Sent To |
|
|
| Notes |
| 2007-06-10 10:58:35 | TO BOB BOARD SPACE #9 ON 6/10 | | 2007-06-05 13:25:57 | WAITING FOR" BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-04-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-20 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-20 |
Time |
12:01 |
Sent To |
|
|
| Notes |
| 2007-04-20 12:02:00 | TO "BOB"#10 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-01-31 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-01-31 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-11-27 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2006-12-06 15:31:41 | TO "BOB"#5--5 APPLICATIONS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
10 |
Status |
P |
Date |
2008-01-31 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-01-31 |
Time |
09:09 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-01-31 |
Time |
09:09 |
Sent To |
|
|
| Notes |
| 2008-01-31 09:10:42 | MECHANICAL REVISION TO PLANS M-1 AND M-2. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
9 |
Status |
P |
Date |
2007-12-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-12-20 |
Time |
09:01 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-12-20 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2007-12-20 09:01:58 | MECH. REVISION TO PLANS PAGE M-1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
F |
Date |
2007-11-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-29 |
Time |
11:53 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-11-29 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2007-11-29 12:18:26 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) NEED WIND LOAD CALCULATIONS TO SHOW THAT CONDENSER | | | STANDS WILL WITHSTAND 140 MPH WINDS PER 2004 FBC 1609. | | | IF PER-ENGINEERED CONDENSER STANDS SUBMIT PRODUCT | | | APPROVAL OR AN NOA FOR PER-ENGINEERED CONDENSER STANDS, | | | SEE FS 553.842(1) AND FAC RULE 9B-72, 9B-72.005, AND | | | FAC 9B-72.010(31)(G). | | | | | | 2) PRODUCT APPROVALS SHALL BE REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD PRIOR TO BEING | | | SUBMITTED FOR JURISDICTIONAL APPROVAL (A SHOP REVIEW | | | STAMP AND SIGNATURE WILL MEET REQUIREMENT). SEE WPB | | | AMEND. 106.3. | | | | | | **PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT | | | IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT | | | HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR | | | LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
F |
Date |
2007-11-02 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-02 |
Time |
09:28 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-11-02 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2007-11-02 09:38:33 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | MECHANICAL REVISION | | | *** DENIED *** | | | 1) MECHANICAL PLAN ON FILE IS SIGNED AND SEALED BY AN | | | ENGINEER (EDWARD J. KRANZ) AND ONLY HE CAN MAKE | | | REVISIONS TO THE PLANS. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2007-07-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-16 |
Time |
10:55 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-07-16 |
Time |
10:55 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2007-07-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-03 |
Time |
15:46 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-07-03 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2007-07-03 15:52:37 | *** DENIED *** | | | 1) ENERGY CALCULATIONS ARE ON THE WRONG FORM. | | | | | | ** 2004 FBC 13-400.3.A METHOD A FORMS. | | | AN ACCURATELY COMPLETED FORM 400A-04R (GENERATED BY THE | | | FLA/COM-2004 COMPUTER PROGRAM, VERSION 2.5) | | | DEMONSTRATING THAT CODE COMPLIANCE HAS BEEN ACHIEVED | | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL FOR METHOD | | | A COMPLIANCE. CALCULATIONS SHALL BE PERFORMED FOR THE | | | CLIMATE ZONE IN WHICH THE BUILDING WILL BE LOCATED AND | | | ACCORDING TO THE PROCEDURES SPECIFIED FOR METHOD A IN | | | THIS SUBCHAPTER. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2007-06-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-06-12 |
Time |
13:54 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-06-12 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2007-06-12 14:04:56 | *** DENIED *** | | | 1) ENERGY CALCULATIONS ARE MISSING THE ARCHITECT'S | | | SEAL, SEE 2004 FBC 13-103.1.1.1, PLEASE CORRECT. | | | | | | 2) PLEASE SUBMIT TWO COPY'S OF THE INPUT DATA REPORT | | | FOR THE ENERGY CAL'S., AS ONLY ONE COPY WAS SUBMITTED. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-04-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-04-24 |
Time |
09:55 |
Rev Time |
1.00 |
| Received By |
tgordon |
Date |
2007-04-24 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2007-04-24 10:01:40 | *** DENIED *** | | | 1) ENERGY CALCULATIONS "PREPARED BY" NEED TO BE SIGNED | | | AND SEALED BY AN ARCHITECT OR ENGINEER, SEE 2004 FBC | | | 13-103.1.1.1. | | | | | | 2) ENERGY CALCULATIONS NEED A "MECHANICAL DESIGNER" WHO | | | IS A ENGINEER, OR AN ARCHITECT, AIR CONDITIONING | | | CONTRACTOR, OR MECHANICAL CONTRACTOR IF APPLICABLE, SEE | | | 2004 FBC 13-103.1.1.1 AND F.S. 471.003 (H). | | | | | | *** 2004 FBC 13-103.1.1.1 COMMERCIAL APPLICATIONS. | | | COMPLETION OF PROCEDURES DEMONSTRATING COMPLIANCE WITH | | | THIS CODE FOR COMMERCIAL BUILDINGS SHALL BE SIGNED AND | | | SEALED BY AN ARCHITECT OR ENGINEER LICENSED TO PRACTICE | | | IN THE STATE OF FLORIDA, WITH THE EXCEPTION OF | | | BUILDINGS EXCLUDED BY SECTION 481.229, FLORIDA STATUTES | | | , OR SECTION 471.003, FLORIDA STATUTES. CALCULATIONS | | | FOR BUILDINGS FALLING WITHIN THE EXCEPTION OF SECTION | | | 471.003, FLORIDA STATUTES , MAY BE PERFORMED BY AIR | | | CONDITIONING OR MECHANICAL CONTRACTORS LICENSED IN | | | ACCORDANCE WITH CHAPTER 489, FLORIDA STATUTES , OR BY | | | STATE OF FLORIDA CERTIFIED COMMERCIAL BUILDING ENERGY | | | RATERS. | | | DESIGN PROFESSIONALS RESPONSIBLE UNDER FLORIDA LAW FOR | | | THE DESIGN OF LIGHTING, ELECTRICAL, MECHANICAL, AND | | | PLUMBING SYSTEMS AND THE BUILDING SHELL, SHALL CERTIFY | | | COMPLIANCE OF THOSE BUILDING SYSTEMS WITH THE CODE BY | | | SIGNING AND PROVIDING THEIR PROFESSIONAL REGISTRATION | | | NUMBER ON THE ENERGY CODE FORM PROVIDED AS PART OF THE | | | PLANS AND SPECIFICATIONS TO THE BUILDING DEPARTMENT. | | | EXCEPTION: TYPED NAMES AND REGISTRATION NUMBERS MAY BE | | | PROVIDED IN LIEU OF A SIGNATURE WHERE ALL RELEVANT | | | INFORMATION HAS BEEN INCLUDED ON SIGNED AND SEALED | | | PLANS. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-03-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-15 |
Time |
16:20 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-03-15 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2007-03-15 16:20:59 | *** DENIED *** | | | 1) AS NOTED IN LAST REVIEW 11-21-06 NOTE #2. SEE | | | COOLING LOAD CALCULATIONS SHOW THAT ALL FIVE BAYS | | | TOGETHER WILL NEED OVER 460 TONS OF A/C, PLEASE SUBMIT | | | CORRECTED COOLING LOAD CALCULATIONS, PER 2004 FBC | | | 13-407.1.ABC.1. | | | | | | 2) THE ENGINEER EDWARD J. KRANZ WILL NEED TO SEAL THE | | | MECHANICAL PLANS AS HIS INFORMATION IS IN THE TITLE | | | BLOCK, SEE FAC 61G15-23.002. (SEE PLANS, PAGES M-1 AND | | | M-2). | | | | | | 3) SEE PLANS, PAGE M-1 "O/A INTAKE" IF THIS IS TYPICAL | | | OF 5 PLEASE STATE SO ON PLANS IF NOT GIVE INFORMATION | | | AT EACH INTAKE. | | | | | | 4) SEE PLANS, PAGE M-1 " 6 INCH DUCT TO EXHAUST WALL | | | LOUVER" IF TYPICAL OF 5 STATE SO ON PLANS IF NOT GIVE | | | INFORMATION AT EACH EXHAUST. | | | | | | 5) SEE PLANS, PAGE 4 ELECTRICAL PLANS SHOW 7 A/C | | | CONDENSER UNITS, MECHANICAL PLANS ONLY SHOW 5, PLEASE | | | CORRECT ELECT. PLANS. | | | | | | 6) SEE PLANS, PAGE M-2A/C SCHEDULE SHOWS THE WRONG | | | EQUIPMENT MANUFACTURE, CAPACITY (TOTAL) BTU'S, SENSIBLE | | | BTU'S, AND A INCORRECT MODEL NUMBER FOR AHU #1. PLEASE | | | REVIEW SUBMITTED MANUFACTURER'S SPECIFICATION'S FOR THE | | | GOODMAN A/C AND CORRECT. | | | | | | 7) SEE ELECTRICAL REVIEW NOTE #2 AND 3. AS A RESULT OF | | | DOCUMENTS BEING RETAINED PLEASE BE CERTAIN TWO COPY'S | | | OF ALL INFORMATION IS BEING SUBMITTED. | | | | | | 8)SEE ATTACHED NOTICE FS 553.80(2)(B) REGARDING FOUR | | | TIMES THE FEE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-11-21 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-11-21 |
Time |
16:27 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-11-21 |
Time |
16:27 |
Sent To |
P |
|
| Notes |
| 2006-11-21 16:28:15 | *** DENIED *** | | | 1) PLEASE SUBMIT ENERGY CALCULATIONS, PER 2004 FBC | | | 13-101.1.1.6 . | | | | | | 2) SEE COOLING LOAD CALCULATIONS PAGE 1, LOAD CAL'S | | | SHOW THAT ALL FIVE BAYS TOGETHER WILL NEED OVER 460 | | | TONS OF A/C, PLEASE RE-DO LOAD CAL'S. | | | | | | 3) CONDENSER UNITS APPEAR TO BE LOCATED IN THE BACK | | | OFFICES, PLEASE CORRECT.. | | | | | | 4) PLEAS SHOW ON THE PLANS EQUIPMENT LISTING, THE | | | SENSIBLE AND TOTAL BTU'S. | | | | | | 5) PLEASE SHOW THE LOCATION OF ALL GRILLS. | | | | | | 6) SEE UNIT B, PLEASE LABEL GRILLS IN BACK OFFICE. | | | | | | 7) PLEASE PROVIDE DETAIL ON BATHROOM EXHAUST DUCTS, ARE | | | THEY INDEPENDENTLY DUCTED TO THE OUTDOORS? | | | | | | 8) PLEASE SHOW THE SIZE OF ALL SUPPLY AND RETURN AIR | | | DUCTS (SEE HIGH LIGHTS ON PLANS). | | | | | | 9) ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE PRINTED NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN. PER | | | FBC 104.2.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2008-01-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-01-23 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-01-23 |
Time |
07:58 |
Sent To |
|
|
| Notes |
| 2008-01-23 08:37:49 | REVISION ADDED A BATHROOM |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-04-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-04-23 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-04-23 |
Time |
08:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-03-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-03-10 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-03-10 |
Time |
13:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-01-31 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-01-31 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-01-31 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2007-01-31 14:57:52 | SEE PLUMBING PLAN REIEW NOTES UNDER PERMIT # 0611563 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
6 |
Status |
P |
Date |
2007-08-16 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2007-08-16 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2007-08-16 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2007-08-16 16:38:15 | GIVEN TO L. MARTINEZ. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2007-07-11 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2007-07-11 |
Time |
17:47 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2007-07-11 |
Time |
17:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2007-06-20 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2007-06-20 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2007-06-20 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2007-06-20 17:00:51 | FAILED - 4TH REVIEW | | | | | | 1) THE COCOPLUM IS SHOWN AS CHR ON THE PLAN BUT AS COC | | | ON THE PLANT LEGEND. | | | | | | 2) THE PERMIT FOR THE IRRIGATION SYSTEM SHALL E | | | SUBMITTED PRIOR TO APPROVAL OF THIS PERMIT. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2007-05-07 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2007-05-07 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2007-05-07 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2007-05-07 17:20:39 | FAILED - 3RD REVIEW | | | | | | 1) A LANDSCAPE PLAN, PREPARED BY A REGISTERED LANDSCAPE | | | ARCHITECT, IS REQUIRED SINCE THERE ARE NEW LANDSCAPE | | | AREAS BEING INSTALLED. | | | | | | 2) THE NEW LANDSCAPE BUFFER ALONG THE SOUTHERN PROPERTY | | | LINE SHALL BE A MINIMUM OF 5 FEET WIDE TO CONFORM TO | | | THE LANDSCAPE CODE.IT SHALL INCLUDE THE TREES AND | | | SHRUBS REQUIRED BY CODE. | | | | | | 3) THE SITE DATA TABLE SHOWS THAT THE EXISTING SITE HAS | | | 90.56% IMPERVIOUS SURFACE (8,060 SQ. FT.).THE PLANS | | | SHOW THE ADDITION OF THE SOUTHERN LANDSCAPE BUFFER, YET | | | THE SITE DATA TABLE DOES NOT SHOW THIS ACCURATELY.THE | | | TABLE SHOWS 8,106 SQ. FT. OF IMPERVIOUS AREA (AN | | | INCREASE) AND 90.29% IMPERVIOUS AREA (A DECREASE). | | | ADDITIONALLY, THE AMOUNT OF LANDSCAPE SHOWN IN THE DATA | | | TABLE DID NOT CHANGE. | | | | | | 4) THE SURVEY SHOWS THE SITE HAVING 8,932.79 SQ. FT., | | | WHILE THE SITE DATA TABLE LISTS 8,900 SQ. FT.THIS | | | NEEDS TO BE CORRECTED. | | | | | | 5) THE SPECIFICATIONS OF THE SCREEN HEDGE FOR THE | | | DUMPSTER ENCLOSURE ARE REQUIRED (SPECIES, HEIGHT, | | | LOCATION AND PLANTING) ON A LANDSCAPE PLAN PREPARED | | | FOLLOWING THE PROVISIONS OF SECTION 94-448(D)(2) OF THE | | | ZONING AND LAND DEVELOPMENT REGULATIONS. | | | | | | 6) AN IRRIGATION PLAN IS REQUIRED. | | | | | | 7) PLEASE NOTE THAT THE WHEEL STOPS SHALL BE 2 FEET | | | FROM THE END OF THE SPACE, THE DOUBLE STRIPES ON THE | | | PARKING SPACES SHALL BE 12 INCHES APART, AND THE ADA | | | LOGO SHALL BE 2 FEET FROM THE MOUTH OF THE ADA SPACE. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-03-14 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2007-03-14 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2007-03-14 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2007-03-14 13:22:58 | FAILED - 2ND REVIEW | | | | | | 1) THE LETTER BY ROBERT BELL, DATED DECEMBER 27, 2007, | | | STATES THAT THE VALUE OF THE RENOVATION TOTALS | | | $230,000.THE APPRAISAL INCLUDED WITH THE RESUBMITTAL | | | PACKAGE GIVES A VALUE OF THE ENTIRE SITE (LAND AND | | | STRUCTURE).THE LANDSCAPE CODE SPECIFICALLY STATES | | | THAT A SITE IS EXEMPT FROM THE REQUIREMENTS OF THE CODE | | | IF THE RENOVATION DOES NOT EXCEED 50% OF THE VALUE OF | | | THE STRUCTURE.IF NO EVIDENCE IS PROVIDED THAT THE | | | VALUE OF THE STRUCTURE EXCEEDS $460,000, THE SITE SHALL | | | BE BROUGHT INTO COMPLIANCE WITH THE LANDSCAPE CODE | | | (SECTION 94-441). | | | | | | 2) THE LANDSCAPE COMPLIANCE LISTED IN COMMENT #1 | | | REQUIRES A LANDSCAPE PLAN PREPARED BY A REGISTERED | | | LANDSCAPE ARCHITECT. | | | | | | 3) WHAT WILL BE PLANTED IN THE PLANTERS?PROVIDE AN | | | IRRIGATION PLAN FOR THE PLANTERS. | | | | | | 4) THE ZONING AND LAND DEVELOPMENT REGULATIONS ALLOW A | | | MAXIMUM OF 85% IMPERVIOUS SURFACE.THE EXISTING SITE | | | IS CURRENTLY NONCONFORMING AS IT HAS 90.56% IMPERVIOUS | | | SURFACE (8,060 SQ. FT.).THE IMPERVIOUS SURFACE ON THE | | | SITE MAY NOT EXCEED THIS AMOUNT.THE PROPOSED PLANS | | | SHOW AN INCREASE IN IMPERVIOUS SURFACE.THIS IS NOT | | | PERMITTED AND SHALL BE CORRECTED.IT MAY REQUIRE | | | REMOVING IMPERVIOUS SURFACE IN ANOTHER AREA TO MAKE UP | | | THE DIFFERENCE. | | | | | | 5) THE PROPOSED DUMPSTER ENCLOSURE SHOWN ON THE PLAN | | | DOES NOT MEET THE CODE REQUIREMENTS.A SET OF PLANS, | | | STAMPED APPROVED BY THE CITY'S ENGINEERING SERVICES | | | DEPARTMENT, SHOWING THE DUMPSTER AND ENCLOSURE SIZE AND | | | LOCATION IS REQUIRED.THE SCREEN WALL FOR THE DUMPSTER | | | MAY NOT BE CHAIN LINK W/SLATS.THE SPECIFICATIONS OF | | | THE SCREEN HEDGE ARE REQUIRED (SPECIES, HEIGHT, | | | LOCATION AND PLANTING) ON A LANDSCAPE PLAN PREPARED | | | FOLLOWING THE PROVISIONS OF SECTION 94-448(D)(2) OF THE | | | ZONING AND LAND DEVELOPMENT REGULATIONS.AN IRRIGATION | | | PLAN IS REQUIRED. | | | | | | 6) NO ACCESSIBLE ROUTE TO ALL OF THE BAYS IS SHOWN. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-01-31 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2007-01-31 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2007-01-31 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2007-01-31 13:53:59 | FAILED | | | | | | 1) THE VALUE OF THE 5 PERMITS TOTALS $95,000 AND THE | | | PROPERTY APPRAISER SHOWS THE VALUE OF THE STRUCTURE AT | | | $84,000.THIS REQUIRES THAT THE SITE BE BROUGHT INTO | | | COMPLIANCE WITH THE LANDSCAPE CODE (SECTION 94-441). | | | | | | 2) A LANDSCAPE PLAN PREPARED BY A REGISTERED LANDSCAPE | | | ARCHITECT IS REQUIRED. | | | | | | 3) EXISTING AND PROPOSED IMPERVIOUS SURFACE | | | CALCULATIONS ARE REQUIRED.THE PROPOSED PLANS APPEAR | | | TO SHOW AN INCREASE IN IMPERVIOUS MATERIAL. | | | | | | 4) NO DUMPSTER DETAIL PROVIDED.THE DUMPSTER ENCLOSURE | | | SHOWN ON THE PLAN DOES NOT APPEAR TO MEET THE CODE | | | REQUIREMENTS. | | | | | | 5) NO ACCESSIBLE ROUTE TO ALL OF THE BAYS IS SHOWN. | | | | | | 6) THE PARKING SPACES ON THE WESTERN SIDE OF THE SITE | | | ENCROACH INTO THE CURB CUT ON BOTH DIXIE AND MONCEAUX | | | AND THUS PRESENT AN UNSAFE SITUATION.THE CURB CUTS | | | SHALL BE CLOSED WHERE CONFLICTS EXIST OR THE PARKING | | | SPACES SHALL BE ELIMINATED. | | | | | | 7) NO SURVEY WAS PROVIDED. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1435. |
|
|