| Plan Review Stops For Permit 06110536 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-01-20 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-01-20 |
Time |
06:44 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-01-20 |
Time |
06:27 |
Sent To |
PC |
|
| Notes |
| 2007-01-20 06:33:34 | BUILDING PROVISO: | | | TO BE IN PLACE AT C.O.: | | | | | | 1) 424.2.17.1 OUTDOOR SWIMMING POOLS. | | | OUTDOOR SWIMMING POOLS SHALL BE PROVIDED | | | WITH A BARRIER COMPLYING WITH | | | 424.2.17.1.1 THROUGH 424.2.17.1.14. | | | | | | 424.2.17.1.5 CHILD SAFETY BARRIER | | | ASTM D5034 100 LB TENSILE STRNGTH | | | ASTM D3787 150 LB BALL BURST STRENGTH | | | | | | 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED. | | | SPAS AND HEATED SWIMMING POOLS SHALL BE | | | EQUIPPED WITH A COVER DESIGNED TO | | | MINIMIZE HEAT LOSS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-12-26 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-12-26 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-12-26 |
Time |
05:59 |
Sent To |
PC |
|
| Notes |
| 2006-12-26 09:53:48 | BUILDING PLAN REVIEW | | | PERMIT:06110536 | | | ADD:108 CORTEZ RD. | | | CONT: STREAMLINE POOL CO. INC. | | | TEL: (561)723-0162 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 1ST | | | ACTION: DENIED | | | | | | 1)WPB AMENDMENTS. 108.3*.THE CLAIMED VALUATION OF | | | THE POOL IS TO LOW. FOR PERMITTING PURPOSES,VALUATION | | | FOR SYSTEMS SHALL BE TOTAL REPLACEMENT COST EXCLUDING | | | LAND VALUE. OUR VALUATION REFERENCE IS ICC (BVD), | | | MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES. | | | ADDITIONAL FEES ARE DUE IN THE AMOUNT OF $222.40 . ON | | | THE APPLICATION DISCRIPTION INCIACTE IF A HEAT PUMP ON | | | SHEET #3 WILL BE INSTALLED. IF THERE WILL BENO HEAT | | | PUMP REMOVE THIS INFORMATION FROM THE DIAGRAM. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-01-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-01-18 |
Time |
15:57 |
Rev Time |
0.25 |
| Received By |
btrobaug |
Date |
2007-01-18 |
Time |
15:52 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-12-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-12-01 |
Time |
10:44 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-12-01 |
Time |
10:24 |
Sent To |
P |
|
| Notes |
| 2006-12-01 10:44:26 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | PLEASE SUBMIT DETAILS FOR THE PANEL SHOWN ON THE | | | SCHEMATIC, FEEDER AND CONDUIT SIZE AND TYPE, PANEL | | | RATING AND OCP,PANEL SCHEDULE AND COMPUTED LOAD, ETC. | | | IF THIS PANEL IS AN EXISTING POOL PANEL, SIMPLY LABEL | | | IT AS SUCH. | | | IF AN ELECTRIC HEATER IS TO BE INSTALLED AS SHOWN ON | | | THE ELECTRICAL SCHEMATIC,PLEASE SUBMIT CALCULATIONS | | | FOR THE MAIN SERVICE AND SPECIFICATIONS FOR THE | | | HEATER. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-01-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-18 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-18 |
Time |
11:49 |
Sent To |
E |
|
| Notes |
| 2007-01-18 11:49:39 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-12-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-27 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-27 |
Time |
13:28 |
Sent To |
Z |
|
| Notes |
| 2006-12-27 13:28:57 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-12-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2006-11-29 |
Time |
17:57 |
Sent To |
|
|
| Notes |
| 2006-11-29 17:57:54 | SENT TO ELECTRICAL BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-12-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-17 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2006-11-17 15:38:08 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-01-19 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-01-19 |
Time |
16:00 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-01-19 |
Time |
16:00 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-12-04 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-12-04 |
Time |
15:34 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-12-04 |
Time |
15:34 |
Sent To |
B |
|
| Notes |
| 2006-12-04 15:56:24 | DENIED | | | REFERENCE: FBC-2004 SEC. 424.2 OR FBCR-2004 SEC.4101 | | | | | | PLEASE ADJUST YOUR NOTES, DETAILS, OR SUBMITTALS TO | | | REFLECT THE FOLLOWING INFORMATION REQUIRED FOR PLUMBING | | | PLAN REVIEW: | | | | | | 1) FBC-2004 SEC. 424.2.6.6.5, OR | | | FBCR-2004 SEC. R4101.6.6.5 WHERE | | | PROVIDED, THE VACUUM OR PRESSURE CLEANER | | | FITTING SHALL BE LOCATED AT LEAST 6" AND | | | NOT GREATER THAN 12" BELOW THE MINIMUM | | | OPERATING WATER LEVEL OR AS AN | | | ATTACHMENT TO THE SKIMMER. | | | NOTE: PLEASE PROVIDE MANUFACTURE CUT SHEET OR LIST MAKE | | | AND MODEL NUMBER OF CLEANING FITTING ON PRINTS. | | | | | | 2) ON SHEET 3 OF 3 THERE IS A HEAT PUMP INDICATED ON | | | THE ELECTRICAL SCHEMATIC IS THIS PART OF THE POOL? IF | | | NOT PLEASE REMOVE. IF THIS IS PART OF THE POOL PLEASE | | | ADD TO PLUMBING SCHEMATIC AND PROVIDE THE FOLLOWING. | | | A) FBC-2004 SEC. 424.2.14.1, OR | | | FBCR-2004 SEC. R4101.14.1 SWIMMING POOL | | | WATER HEATERS SHALL BEAR THE LABEL OF A | | | RECOGNIZED TESTING AGENCY. (MANUFACTURE | | | SHEETS REQUIRED, PLEASE SUBMIT) | | | B) FBC-2004 SEC. 424.2.14.2, OR | | | FBCR-2004 SEC. R4101.14.2 WATER | | | RETENTION, PROVIDE A POSITIVE MEANS OF | | | RETAINING WATER IN THE HEATER WHEN PUMP | | | IS SHUT OFF.(MANUFACTURE SHEETS | | | REQUIRED, PLEASE SUBMIT) | | | C) FBC-2004 SEC. 424.2.14.4, OR | | | FBCR-2004 SEC. R4101.14.4 CONNECTIONS, | | | ALL WATER HEATING EQUIPMENT SHALL BE | | | INSTALLED WITH FLANGES OR UNION | | | CONNECTIONS ADJACENT TO THE HEATER. | | | (ADD TO NOTES) | | | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-01-17 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-01-17 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-01-17 |
Time |
16:11 |
Sent To |
I |
|
| Notes |
| 2007-01-17 16:13:08 | 1/17/06 ***PASSED WITH PROVISOS*** | | | | | | 1) THIS PERMIT IS ONLY FOR THE POOL, POOL EQUIPMENT AND | | | POOL DECK. | | | 2) SEPARATE PERMIT APPLICATION SHALL BE SUBMITTED FOR | | | THE FENCE/POOL ENCLOSURE. | | | 3) FINAL INSPECTION OF THE POOL SHALL NOT OCCUR UNTIL | | | AFTER THE C.O. HAS BEEN ISSUED FOR THE RESIDENCE. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT JOHN ROACH, SENIOR | | | PLANNER, AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-11-26 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-11-26 |
Time |
22:58 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-11-26 |
Time |
22:58 |
Sent To |
I |
|
| Notes |
| 2006-11-26 23:02:08 | DENIED. | | | 1. NEED TO SHOW THE LOCATION OF THE PROPOSED POOL | | | EQUIPMENT ON TWO COPIES OF SURVEYS WITHIN THE | | | EASEMENTS. | | | 2. PLEASE CLAIFY IF THE PROPOSED LANI IS APART OF THE | | | POOL PERMIT. NEED TO GENERATE A SEPERATE MISC PERMIT | | | FOR THE PROPOSED WORK. | | | 3. NEED TO SHOW INTERIOR ACCESS OF THE MAIN HOUSE TO | | | THE PROPOSED LANI. 2 COPIES OF FLOOR PLANS NEEDED AND | | | ELEVATION PLANS. | | | 4. PLEASE PROVIDE THE SIDE SETBACK OF THE PROPOSED | | | LANI. | | | | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|