Plan Review Details - Permit 06110427
Plan Review Stops For Permit 06110427
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-04-05 Cont ID  
Sent By rmcdouga Date 2007-04-05 Time 07:26 Rev Time 0.00
Received By rmcdouga Date 2007-04-04 Time 18:21 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-03-27 Cont ID  
Sent By rmcdouga Date 2007-03-27 Time 12:27 Rev Time 0.00
Received By rmcdouga Date 2007-03-27 Time 12:27 Sent To  
Notes
2007-03-27 13:10:56DENIED BY BUILDING (2ND REVIEW)
  
 THE FOLLOWING ITEMS FROM THE FIRST REVIEW WERE NOT
 ADDRESSED.
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2)SPECIFY THE SIZE OF THE REMAINING WINDOW IN THE
 BEDROOM ADJACENT TO THE NEW ADDITION. SEE R 310 FOR
 EMERGENCY EGRESS REQUIREMENTS.
  
 3)THE NEW BATHROOM DOOR IS REQUIRED TO HAVE A 29"
 CLEAR OPENING. SEE R 322.
  
 4) SUBMIT SIGNED AND SEALED TRUSS DRAWINGS REVIEWED AND
 APPROVED BY THE DESIGNER OF RECORD AS REQUIRED BY
 R802.1.6.1. GIVE TO BUILDING INSPECTOR IN THE FIELD.
  
 5) SUBMIT A DRAINAGE PLAN SHOWING COMPLIANCE WITH THE
 REQUIREMENTS OF R401.3.
  
 6) THE TRUSS CONNECTION FOR THE SIMPSON HTSM16 REQUIRES
 (8) 10D NAILS FOR THE STATED UPLIFT VALUE PER THE
 SIMPSON CATALOG. PLEASE REVISE.
  
 7) THE CORNERS OF HIP ROOFS ARE ALSO ZONE 3. PLEASE
 CORRECT THE ROOF ZONE DIAGRAM ON SHEET 11. SEE FIGURE
 803.2.3.1 AND FBC FIGURE 1609.6.2.2.
  
 8) SPECIFY THE ROOF VENTILATION AS REQUIRED BY R 806.
  
 9) SPECIFY THE SIZE AND LOCATION OF THE ATTIC ACCESS
 REQUIRED BY R 807.
  
 10) SAFETY GLAZING IS REQUIRED IN BATHROOM WINDOW PER R
 308.4 IF BOTTOM OF WINDOW IS LESS THAN 60" ABOVE
 FLOOR.
  
 11) SUBMIT PRODUCT APPROVALS FOR THE STRUCTURAL WINDOW
 MULLIONS.
  
 12) SUBMIT FLORIDA PRODUCT APPROVAL COVERSHEETS FOR THE
 2004 CODE EDITION. MOST OF THE ONES SUBMITTED ARE FOR
 2001 CODE.
  
 13) SEVERAL OF THE MIAMI-DADE NOAS THAT WERE SUBMITTED
 ARE EXPIRED. PLEASE REVIEW THE PRODUCT APPROVALS AND
 SUBMIT CURRENT INFORMATION.
  
 14) ONLY TWO COMPLETE SETS OF PLANS AND SUBMITTALS ARE
 REQUIRED.
  
 PLEASE SUBMIT A TRANSMITTAL LETTER WITH THE RESUBMITTAL
 INDICATING HOW THE COMMENTS HAVE BEEN ADDRESSED.
  
 NEW ITEMS :
  
 15) THE REAR ELEVATION ON SHEET 4 DOES NOT SHOW THE
 EXTERIOR DOOR TO THE BATHROOM.
  
 16) ON SHEET 9, SIMPSON META 14 CONNECTORS ARE
 SPECIFIED AT AN EXISTING WALL OF THE NEW LAUNDRY ROOM.
 PLEASE SPECIFY AN APPROPRIATE CONNECTOR. SEE RED MARKS
 ON PLANS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-01-23 Cont ID  
Sent By rmcdouga Date 2007-01-23 Time 18:05 Rev Time 0.00
Received By rmcdouga Date 2007-01-23 Time 18:05 Sent To  
Notes
2007-01-24 06:36:02DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) SUBMIT ENERGY CALCULATIONS REQUIRED BY FBC CHAPTER
 11.
  
 4)SPECIFY THE SIZE OF THE REMAINING WINDOW IN THE
 BEDROOM ADJACENT TO THE NEW ADDITION. SEE R 310 FOR
 EMERGENCY EGRESS REQUIREMENTS.
  
 5)THE NEW BATHROOM DOOR IS REQUIRED TO HAVE A 29"
 CLEAR OPENING. SEE R 322.
  
 6) SUBMIT SIGNED AND SEALED TRUSS DRAWINGS REVIEWED AND
 APPROVED BY THE DESIGNER OF RECORD AS REQUIRED BY
 R802.1.6.1.
  
 7) SUBMIT A DRAINAGE PLAN SHOWING COMPLIANCE WITH THE
 REQUIREMENTS OF R401.3.
  
 8) THE TRUSS CONNECTION FOR THE SIMPSON HTSM16 REQUIRES
 (8) 10D NAILS FOR THE STATED UPLIFT VALUE PER THE
 SIMPSON CATALOG. PLEASE REVISE.
  
 9) THE CORNERS OF HIP ROOFS ARE ALSO ZONE 3. PLEASE
 CORRECT THE ROOF ZONE DIAGRAM ON SHEET 11. SEE FIGURE
 803.2.3.1 AND FBC FIGURE 1609.6.2.2.
  
 10) SPECIFY THE ROOF VENTILATION AS REQUIRED BY R 806.
  
 11) SPECIFY THE SIZE AND LOCATION OF THE ATTIC ACCESS
 REQUIRED BY R 807.
  
 12) SAFETY GLAZING IS REQUIRED IN BATHROOM WINDOW PER R
 308.4 IF BOTTOM OF WINDOW IS LESS THAN 60" ABOVE
 FLOOR.
  
 13) SUBMIT PRODUCT APPROVALS FOR THE STRUCTURAL WINDOW
 MULLIONS.
  
 14) SUBMIT FLORIDA PRODUCT APPROVAL COVERSHEETS FOR THE
 2004 CODE EDITION. MOST OF THE ONES SUBMITTED ARE FOR
 2001 CODE.
  
 15) SEVERAL OF THE MIAMI-DADE NOAS THAT WERE SUBMITTED
 ARE EXPIRED. PLEASE REVIEW THE PRODUCT APPROVALS AND
 SUBMIT CURRENT INFORMATION.
  
 16) ONLY TWO COMPLETE SETS OF PLANS AND SUBMITTALS ARE
 REQUIRED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-11-28 Cont ID  
Sent By btrobaug Date 2006-11-28 Time 14:03 Rev Time 0.50
Received By btrobaug Date 2006-11-28 Time 13:56 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-04-02 Cont ID  
Sent By spalmer Date 2007-04-02 Time 15:43 Rev Time 0.00
Received By spalmer Date 2007-04-02 Time 15:43 Sent To B
Notes
2007-04-02 15:43:23TO ROBERT MCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-03-10 Cont ID  
Sent By adarroug Date 2007-03-10 Time 12:10 Rev Time 0.00
Received By adarroug Date 2007-03-10 Time 12:10 Sent To M
Notes
2007-03-10 12:10:44TO "M" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-12-06 Cont ID  
Sent By adarroug Date 2006-12-06 Time 10:35 Rev Time 0.00
Received By adarroug Date 2006-12-06 Time 10:35 Sent To M
Notes
2006-12-06 10:35:51TO "M" BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-12-04 Cont ID  
Sent By adarroug Date 2006-12-04 Time 11:58 Rev Time 0.00
Received By adarroug Date 2006-12-04 Time 11:58 Sent To Z
Notes
2006-12-04 11:59:24PLANS ROUTED BACK TO "Z".PLANS STAMPED BY "Z", BUT NO
 REVIEW WAS ENTERED IN SYSTEM.ADARROUGH

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-01-24 Cont ID  
Sent By rmcdouga Date 2007-01-24 Time 06:36 Rev Time 0.00
Received By rmcdouga Date 2006-11-15 Time 11:57 Sent To  
Notes
2006-11-15 16:15:02TO "E" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-03-12 Cont ID  
Sent By tgordon Date 2007-03-12 Time 14:29 Rev Time 0.25
Received By tgordon Date 2007-03-12 Time 14:29 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-12-11 Cont ID  
Sent By tgordon Date 2006-12-11 Time 16:12 Rev Time 0.25
Received By tgordon Date 2006-12-11 Time 16:12 Sent To P
Notes
2006-12-11 16:17:05*** DENIED ***
 1) PLEASE SUBMIT ENERGY CALCULATIONS, PER 2004 FBC
 13-600.3.C.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-03-22 Cont ID  
Sent By mperson Date 2007-03-22 Time 11:02 Rev Time 0.33
Received By mperson Date 2007-03-22 Time 11:02 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-12-12 Cont ID  
Sent By mperson Date 2006-12-12 Time 13:17 Rev Time 0.45
Received By mperson Date 2006-12-12 Time 13:17 Sent To B
Notes
2006-12-12 13:35:03DENIED
 REFERENCE: FBC-2004 PLUMBING
  
 THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING
 PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. SHEET 13 0F 13 SANITARY RISER DIAGRAM DOES NOT
 REFLECT THE FLOOR PLAN. PLEASE REFERENCE THE CORRECTED
 SANITARY RISER DIAGRAM IN RED INK FOR THE RESUBMITTAL.
  
 A) BATHROOM LAVATORY NEEDS TO BE PIPED WITH A WYE
 FITTING NOT OFF A DOUBLE COMBO FITTING
 B) WASTE ARMS ARE MISSING FOR THE DOUBLE BOWL KITCHEN
 SINK.
  
 **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.AS INDICATED.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop Z ZONING
Rev No 1 Status P Date 2006-12-01 Cont ID  
Sent By mmclean Date 2006-12-01 Time 09:38 Rev Time 0.00
Received By mmclean Date 2006-12-01 Time 09:38 Sent To I
Notes
***NONE***