Plan Review Details - Permit 06110355
Plan Review Stops For Permit 06110355
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-08-01 Cont ID  
Sent By jwitmer Date 2007-08-01 Time 16:30 Rev Time 0.75
Received By jwitmer Date 2007-08-01 Time 16:30 Sent To  
Notes
2007-08-01 16:31:21RESTAMP AND PERMIT CARD

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-06-26 Cont ID  
Sent By jwitmer Date 2007-06-26 Time 09:05 Rev Time 0.77
Received By jwitmer Date 2007-06-26 Time 09:05 Sent To E
Notes
2007-06-26 09:08:12BUILDING PLAN REVIEW
 PERMIT: 06110355
 ADD: 1400 CENTREPARK MAIN LOBBY
 CONT: ANDERSON MOORE
 TEL: (561)662-0968
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2) PLANS ARE COPIES NOT ORIGINALS, PLANS ALSO NEED TO
 BE SIGNED AND SEALED BY THE DESIGNER OF RECORD.
  
 BUILDING PLAN REVIEW II
 JIM WITMER C. B. O.
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-12-12 Cont ID  
Sent By jwitmer Date 2006-12-12 Time 15:47 Rev Time 1.11
Received By jwitmer Date 2006-12-12 Time 15:16 Sent To  
Notes
2006-12-12 15:54:00 
 *** ISSUED PERMIT***
 -PLAN REVIEW HISTORY-
  
 PERMIT#06110355
 ADDRESS: 1400 CENTREPARK 1ST FLOOR LOBBY
 CONT: PASS INTERNATIONAL
 TELL NUMBER 954)421-9000
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
  
 FBC*= 2004 FLORIDA BUILDING CODE WITH 2006 REVISIONS
  
 BUILDING PROVISOS:
  
 803.1 GENERAL.
 INTERIOR WALL AND CEILING FINISHES SHALL BE CLASSIFIED
 IN ACCORDANCE WITH ASTM E 84.
 SUCH INTERIOR FINISH MATERIALS SHALL BE GROUPED IN THE
 FOLLOWING CLASSES IN ACCORDANCE
 WITH THEIR FLAME SPREAD AND SMOKE-DEVELOPED INDEX.
 CLASS A:
 FLAME SPREAD INDEX 0-25; SMOKE-DEVELOPED INDEX 0-450.
 CLASS B:
 FLAME SPREAD INDEX 26-75; SMOKE-DEVELOPED INDEX 0-450.
  
 CLASS C:
 FLAME SPREAD INDEX 76-200; SMOKE-DEVELOPED INDEX 0-450.
  
  
  
 803.4.4 MATERIALS.
 AN INTERIOR WALL OR CEILING FINISH THAT IS NOT MORE
 THAN 0.25 INCH (6.4 MM) THICK SHALL BE
 APPLIED DIRECTLY AGAINST A NONCOMBUSTIBLE BACKING.
 EXCEPTIONS:
 1.CLASS A MATERIALS.
 2.MATERIALS WHERE THE QUALIFYING TESTS WERE MADE
 WITH THE MATERIAL SUSPENDED OR
 FURRED OUT FROM THE NONCOMBUSTIBLE BACKING.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-07-23 Cont ID  
Sent By dpalmer Date 2007-07-23 Time 13:11 Rev Time 0.00
Received By dpalmer Date 2007-07-23 Time 13:11 Sent To B
Notes
2007-07-23 13:12:13RE-STAMP ONLY.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-06-26 Cont ID  
Sent By dpalmer Date 2007-06-26 Time 10:06 Rev Time 0.00
Received By dpalmer Date 2007-06-26 Time 09:41 Sent To PC
Notes
2007-06-26 10:06:55*** UNSAT ***
  
 1) NOTE: PLEASE SUBMIT PLANS WHICH ARE SIGNED, DATED
 AND SEALED BY THE DESIGNER OF RECORD. PLEASE SEE FAC
 61G15-23.002 AND FS 471.025.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-11-28 Cont ID  
Sent By dpalmer Date 2006-11-28 Time 08:18 Rev Time 0.00
Received By dpalmer Date 2006-11-28 Time 08:11 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2006-12-11 Cont ID  
Sent By mawillia Date 2006-12-11 Time 16:18 Rev Time 0.00
Received By mawillia Date 2006-12-11 Time 16:11 Sent To  
Notes
2006-12-11 16:26:19*****APPROVED W/REMINDER******
  
  
  
 IF THE THE FIRE ALARM OR FIRE SPRINKLER SYSTEM IS
 MODIFIED DUE TO THE SCOPE OF WORK, SEPARATE PLAN AND
 PERMIT ARE REQUIRED.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-07-23 Cont ID  
Sent By adarroug Date 2007-07-23 Time 08:39 Rev Time 0.00
Received By adarroug Date 2007-07-23 Time 08:39 Sent To E
Notes
2007-07-23 08:43:09TO "DPALMER" DESK/RESTAMP

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-06-13 Cont ID  
Sent By adarroug Date 2007-06-13 Time 16:24 Rev Time 0.00
Received By adarroug Date 2007-06-13 Time 16:24 Sent To B
Notes
2007-06-13 16:24:59TO "JWITMER" DESK/RESTAMP

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-12-12 Cont ID  
Sent By jwitmer Date 2006-12-12 Time 15:54 Rev Time 0.00
Received By jwitmer Date 2006-11-12 Time 14:39 Sent To  
Notes
2006-11-27 09:09:33TO "BOB"#11
2006-11-12 14:40:40WAITING FOR "BOB"