Plan Review Details - Permit 06110350
Plan Review Stops For Permit 06110350
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-03-06 Cont ID  
Sent By jwitmer Date 2007-03-06 Time 09:23 Rev Time 1.33
Received By jwitmer Date 2007-03-06 Time 09:23 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-12-11 Cont ID  
Sent By jwitmer Date 2006-12-11 Time 14:48 Rev Time 2.22
Received By jwitmer Date 2006-12-11 Time 14:48 Sent To  
Notes
2006-12-11 16:57:30BUILDING PLAN REVIEW
 PERMIT: 06110350
 ADD: 1601 FORUM PLACE SUITE 900/905
 CONT: PASS INTERNATIONAL
 TEL: (561)#702-9668
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2 ) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS
 NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
  
 3) 106.1.2* DISCREPANCY BETWEEN THE PERMIT APPLICATION
 AND ON THE COVER SHEET WHERE THE WORK UNDER THIS
 PERMIT
 IS TO OCCUR.
  
 4)SHEET A-1 INDICATES EXITING THROUGH ROOM 103
 LABELEDTELEPHONE CLOSET.
 THE ELECTRICAL SHEETS ALSO CONFIRM WITH EXITING
 LIGHTING THAT THIS IS A PROPOSED
 EXIT PATHWAY.
 1013.2 EGRESS THROUGH INTERVENING SPACES.
 EGRESS FROM A ROOM OR SPACE SHALL NOT PASS THROUGH
 ADJOINING OR INTERVENING
 ROOMS OR AREAS, EXCEPT WHERE SUCH ADJOINING ROOMS OR
 AREAS ARE ACCESSORY
 TO THE AREA SERVED; ARE NOT A HIGH-HAZARD OCCUPANCY AND
 PROVIDE A DISCERNIBLE
 PATH OF EGRESS TRAVEL TO AN EXIT. EGRESS SHALL NOT PASS
 THROUGH KITCHENS, STORAGE
 ROOMS, CLOSETS OR SPACES USED FOR SIMILAR PURPOSES. AN
 EXIT ACCESS SHALL NOT PASS
 THROUGH A ROOM THAT CAN BE LOCKED TO PREVENT EGRESS.
 MEANS OF EGRESS FROM
 DWELLING UNITS OR SLEEPING AREAS SHALL NOT LEAD THROUGH
 OTHER SLEEPING AREAS,
 TOILET ROOMS OR BATHROOMS.
  
 5) SHEET A-1 THE EXISTING DOOR OF THE TELEPHONE CLOSET
 DOESN'T HAVE THE REQUIRED
 18" LAATCH SIDE OF DOOR.11-4.13.6 MANEUVERING
 CLEARENCES
 AT DOORS. MINIMUM MANEUVERING CLEARANCES
 AT DOORS THAT ARE NOT AUTOMATIC OR
 POWER-ASSISTED SHALL BE AS SHOWN IN
 FIG. 25. THE FLOOR OR GROUND AREA WITH
 IN THE REQUIRED CLEARANCES SHALL BE
 CLEAR & LEVEL.
 THE SECOND ISSUE IS THE FIRE EXTINGUISHER IN THE 18"
 CLEAR FLOOR SPACE.
 11-4.4.1 GENERAL.
 OBJECTS PROJECTING FROM WALLS (FOR EXAMPLE, TELEPHONES)
 WITH THEIR LEADING EDGES BETWEEN 27 INCHES AND 80
 INCHES (685 MM AND 2030 MM) ABOVE THE FINISHED FLOOR
 SHALL PROTRUDE NO MORE THAN 4 INCHES (102 MM) INTO
 WALKS, HALLS, CORRIDORS, PASSAGEWAYS, OR AISLES [SEE
 FIGURE 11-8 (A)]. OBJECTS MOUNTED WITH THEIR LEADING
 EDGES AT OR BELOW 27 INCHES (685 MM) ABOVE THE FINISHED
 FLOOR MAY PROTRUDE ANY AMOUNT [SEE FIGURE 11-8 (A) AND
 FIGURE 11-8 (B)]. FREE-STANDING OBJECTS MOUNTED ON
 POSTS OR PYLONS MAY OVERHANG 12 INCHES (305 MM) MAXIMUM
 FROM 27 INCHES TO 80 INCHES (685 MM TO 2030 MM) ABOVE
 THE GROUND OR FINISHED FLOOR [SEE FIGURE 11-8 (C) AND
 FIGURE 11-8 (D)]. PROTRUDING OBJECTS SHALL NOT REDUCE
 THE CLEAR WIDTH OF AN ACCESSIBLE ROUTE OR MANEUVERING
 SPACE [SEE FIGURE 11-8 (E)].
  
 6) MEP DRAWINGS THE ARCHITECT DOESN'T HAVE HIS PRINTED
 NAME IN THE HEADER STRIP.
 61G1-16.004FL. ADMIN. CODE.PLANS
 PREPARED BY A REGISTERED ARCHITECT SHALL
 INCLUDE A TITLE BLOCK WHICH MUST:
 - STATE THE FIRM NAME, ADDRESS AND
 TELEPHONE NUMBER
 - STATE THE FIRM LICENSE NUMBER
 - STATE PROJECT NAME OR IDENTIFICATION
 - STATE DATE PREPARED
 - INCLUDE AN ORIGINAL SIGNATURE AND
 DATED SEAL
 - INCLUDE THE PRINTED NAME OF THE
 ARCHITECT SEALING THE PLANS
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-02-08 Cont ID  
Sent By dpalmer Date 2007-02-08 Time 12:35 Rev Time 0.00
Received By dpalmer Date 2007-02-08 Time 12:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-11-20 Cont ID  
Sent By dpalmer Date 2006-11-20 Time 07:23 Rev Time 0.00
Received By dpalmer Date 2006-11-20 Time 07:15 Sent To  
Notes
2006-11-20 07:24:06** UNSAT **
  
 1) NOTE: PLEASE SEE PLANS MENTIONS COMBINING OF TWO
 UNITS INTO ONE HOWEVER NOTES INDICATE UNITS 905 WITH
 900, YET SQ FT TABLE INDICATE 905 AND 901?
 PLEASE CORRELATE AND CORRECT. THIS TITLE BLOCKS WITH
 THE CORRECT UNIT IT WILL BECOME WILL BE AFFECTED BY
 THIS.
  
 FBC 106.1.2, FAC 61G1-16.004
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 **PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. **IF
 THERE ARE ANY QUESTIONS, COMMENTSOR IF ANY OF THE
 NOTES TYPEDWHICH ARE UNCLEAR IN ANY WAY, PLEASE DO
 NOT HESITATEIN CONTACTING THIS REVIEWER.
  
  
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2007-03-03 Cont ID  
Sent By mawillia Date 2007-03-03 Time 16:26 Rev Time 0.00
Received By mawillia Date 2007-03-03 Time 16:02 Sent To  
Notes
2007-03-03 16:28:16*****APPROVED*****
  
  
 ALL COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE
 BEEN ADDRESSED.PLAN SHEET A-2 STAMPED, INITIALED, AND
 DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-01-08 Cont ID  
Sent By mawillia Date 2007-01-08 Time 12:26 Rev Time 0.00
Received By mawillia Date 2007-01-08 Time 12:18 Sent To  
Notes
2007-01-08 13:01:10*****DENIED*****
  
  
 1. IN ADDITION TO NFPA 101 (2003 EDITION), THE FLORIDA
 FIRE PREVENTION CODE (2004 EDITION) SHALL ALSO BE
 REFERENCED.
  
 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 3.CONSTRUCTION AND/OR DEMOLITION OPERATIONS SHALL NOT
 INTERFERE OR HINDER ACCESS TO OR EGRESS FROM OTHER
 TENANT SPACES ON THE NINTH FLOOR.
  
 4.EXITS ARE TO REMAIN CLEAR AND SHALL BE MAINTAINED.
  
 5.COMBUSTIBLE WASTE MATERIAL, DUST, AND DEBRIS SHALL
 BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR
 MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATIONS.
  
 6.FIRE PROTECTION SYSTEMS SHALL BE MAINTAINED
 OPERATIONAL AT ALL TIMES DURING ALTERATION.ANY
 MODIFICATIONS TO THE FIRE PROTECTIVE SYSTEMS DUE TO THE
 SCOPE OF WORK WILL REQUIRE SEPARATE PLANS AND PERMIT.
  
 7.PROVIDE A LIFE SAFETY PLAN SHEET INDICATING THE
 TRAVEL DISTANCE TO REACH AN EXIT.THE LOCATION OF EXIT
 LIGHTS, EMERGENCY LIGHTS, FIRE EXTINGUISHERS MAY ALSO
 BE INCLUDED.
  
 8.PROVIDE INTERIOR FINISH CLASSIFICATION FOR THE
 STRUCTURE.BE ADVISED THAT INTERIOR WALL AND CEILING
 FINISH MATERIALS IN EXITS AND IN EXIT ACCESS CORRIDORS
 SHALL BE CLASS "A" OR CLASS "B";SHALL BE CLASS A,
 CLASS B, OR CLASS C IN ALL OTHER AREAS.
  
 9.SINCE TWO UNITS ARE BEING COMBINED TO FORM A SINGLE
 UNIT, THE APPROPIATE SUITE NUMBER SHALL BE IN THE TITLE
 BLOCK OF THE SUBMITTED PLAN SHEETS.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS WHEN RESUBMITTING,
 INCLUDE A RESPONSE LETTER INDICATING HOW/WHERE EACH
 ITEM WAS ADDRESSED.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-01-29 Cont ID  
Sent By adarroug Date 2007-01-29 Time 18:21 Rev Time 0.00
Received By adarroug Date 2007-01-29 Time 18:21 Sent To  
Notes
2007-03-02 14:12:073/2/07--APPL MOVED TO "BOB"#16-PER "LMARTINEZ"
2007-02-07 08:53:39TO "COMM" BD#35
2007-01-29 18:21:53WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-01-08 Cont ID  
Sent By mawillia Date 2007-01-08 Time 13:07 Rev Time 0.00
Received By mawillia Date 2006-11-12 Time 14:42 Sent To  
Notes
2006-11-14 10:34:07TO "COMM" BD#52
2006-11-12 14:43:46WAITING FOR "COMM' BD

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-02-15 Cont ID  
Sent By tgordon Date 2007-02-15 Time 15:53 Rev Time 0.20
Received By tgordon Date 2007-02-15 Time 15:53 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2006-11-15 Cont ID  
Sent By tgordon Date 2006-11-15 Time 16:40 Rev Time 0.30
Received By tgordon Date 2006-11-15 Time 16:40 Sent To  
Notes
***NONE***