Plan Review Details - Permit 06110334
| Plan Review Stops For Permit 06110334 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-11-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-11-16 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-11-16 |
Time |
09:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-11-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-11-15 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-11-15 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2006-11-15 17:15:13 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC EB | | | FLORIDA BUILDING CODE 2004 EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | | | | 1.)THE FLAT DECK SYSTEM CHOSEN HAS A DESIGN PRESSURE | | | LIMITATION OF -45 AND REFERENCES GENERAL LIMITATION #9. | | | THIS DOES NOT MEET THE DESIGN PRESSURE REQUIREMENTS OF | | | ZONES 2 AND 3.ENHANCED FASTENING ALLOWED ONLY FOR | | | SYSTEMS WHICH REFER TO GENERAL LIMITATION #7. | | | | | | 2.)PLEASE SUBMIT TWO COLLATED SETS WITH ALL DOCUMENTS | | | REQUIRED FOR PERMITTING. | | | | | | 3.)IF ENHANCED FASTENING IS REQUIRED, PLEASE SPECIFY | | | FASTENING FOR ZONES 2 AND 3. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-11-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-11-13 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-11-13 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2006-11-13 10:49:16 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | ROOFING PERMIT; ONLY CHECKED ITEMS APPLY | | | | | | ____1.)A NOTICE OF COMMENCEMENT MUST BE FILED WITH | | | THE CLERK OF COURTS BEFORE A PERMIT CAN BE ISSUED. | | | | | | ____2.)CONTRACTOR IS TO PROVIDE THE FOLLOWING | | | INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY: | | | | | | MEAN ROOF HEIGHT | | | ROOF PITCH | | | ROOF DECK TYPE | | | AREA OF EACH ROOF TYPE | | | | | | _XX_3.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED IN ADDITION TO THE EVALUATION REPORT | | | SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG | | | THE STATE PRODUCT APPROVAL FOR THE | | | RIDGE VENT IS EXPIRED, 2001 CODE RATHER THAN 2004 | | | CODE. | | | | | | _XX_4.)FOR THE FLAT DECK, SELECT THE APPROVED | | | ASSEMBLY YOU ARE USING. | | | | | | ____ 5.)ON THE TILE PRODUCT APPROVAL, INDICATE WHICH | | | METHOD OF ATTACHMENT YOU ARE USING. | | | | | | _XX_ 6.)SEE PRODUCT LIMITATION #7.CALCULATIONS | | | PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF | | | CONSULTANT REQUIRED FOR ENHANCED FASTENING (FLAT | | | DECK). | | | |
|
|
|