Plan Review Details - Permit 06110334
Plan Review Stops For Permit 06110334
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-11-16 Cont ID  
Sent By shill Date 2006-11-16 Time 09:27 Rev Time 0.00
Received By shill Date 2006-11-16 Time 09:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-11-15 Cont ID  
Sent By shill Date 2006-11-15 Time 17:11 Rev Time 0.00
Received By shill Date 2006-11-15 Time 17:11 Sent To  
Notes
2006-11-15 17:15:13****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC EB
 FLORIDA BUILDING CODE 2004 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE
 FBC2004
  
 1.)THE FLAT DECK SYSTEM CHOSEN HAS A DESIGN PRESSURE
 LIMITATION OF -45 AND REFERENCES GENERAL LIMITATION #9.
 THIS DOES NOT MEET THE DESIGN PRESSURE REQUIREMENTS OF
 ZONES 2 AND 3.ENHANCED FASTENING ALLOWED ONLY FOR
 SYSTEMS WHICH REFER TO GENERAL LIMITATION #7.
  
 2.)PLEASE SUBMIT TWO COLLATED SETS WITH ALL DOCUMENTS
 REQUIRED FOR PERMITTING.
  
 3.)IF ENHANCED FASTENING IS REQUIRED, PLEASE SPECIFY
 FASTENING FOR ZONES 2 AND 3.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-11-13 Cont ID  
Sent By shill Date 2006-11-13 Time 10:48 Rev Time 0.00
Received By shill Date 2006-11-13 Time 10:48 Sent To  
Notes
2006-11-13 10:49:16****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 ROOFING PERMIT; ONLY CHECKED ITEMS APPLY
  
 ____1.)A NOTICE OF COMMENCEMENT MUST BE FILED WITH
 THE CLERK OF COURTS BEFORE A PERMIT CAN BE ISSUED.
  
 ____2.)CONTRACTOR IS TO PROVIDE THE FOLLOWING
 INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY:
  
 MEAN ROOF HEIGHT
  ROOF PITCH
  ROOF DECK TYPE
  AREA OF EACH ROOF TYPE
  
 _XX_3.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED IN ADDITION TO THE EVALUATION REPORT
 SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG
 THE STATE PRODUCT APPROVAL FOR THE
 RIDGE VENT IS EXPIRED, 2001 CODE RATHER THAN 2004
 CODE.
  
 _XX_4.)FOR THE FLAT DECK, SELECT THE APPROVED
 ASSEMBLY YOU ARE USING.
  
 ____ 5.)ON THE TILE PRODUCT APPROVAL, INDICATE WHICH
 METHOD OF ATTACHMENT YOU ARE USING.
  
 _XX_ 6.)SEE PRODUCT LIMITATION #7.CALCULATIONS
 PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF
 CONSULTANT REQUIRED FOR ENHANCED FASTENING (FLAT
 DECK).
  