| Plan Review Stops For Permit 06110325 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-01-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-01-24 |
Time |
16:26 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2007-01-24 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2007-01-24 16:38:01 | BUILDING PLAN REVIEW | | | PERMIT:06110325 | | | ADD: 1611 WORTHINGTON RD. | | | CONT: POOL TEK OF THE PALM BEACHES | | | TEL: (561)514-1514 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | ---BUILDING REVIEW ---- | | | | | | *** ISSUED PERMIT*** | | | -PLAN REVIEW HISTORY- | | | | | | THEATTACHED COMMENTS ARE PART OF THE | | | PERMIT AND PLAN REVIEW PACKAGE AND ARE | | | NOT TO BE REMOVED FROM THE ISSUED SET | | | OF PLANS.104.2.1.2 ADMINISTRATIVE CODE. | | | | | | BUILDING PROVISO: | | | 13-412.1.ABC.2.6.2 COVERS REQUIRED. | | | SPAS AND HEATED SWIMMING POOLS SHALL BE | | | EQUIPPED WITH A COVER DESIGNED TO | | | MINIMIZE HEAT LOSS AT TIME OF C/O. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-12-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-12-11 |
Time |
13:18 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2006-12-11 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2006-12-11 13:24:59 | BUILDING PLAN REVIEW | | | PERMIT: 06110325 | | | ADD: 1611 WORTHINGTON RD | | | CONT: POOL TEC | | | TEL: (561)514-1514 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1STREVIEW | | | ACTION: DENIED | | | 13-412.1.ABC.2.6.2 POOL COVERS. | | | HEATED POOLS SHALL BE EQUIPPED WITH A VAPOR RETARDANT | | | POOL | | | COVER ON OR AT THE WATER SURFACE. POOLS HEATED TO MORE | | | THAN | | | 90?F (32?C) SHALL HAVE A POOL COVER WITH A MINIMUM | | | INSULATION | | | VALUE OF R -12. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-01-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-01-30 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-01-30 |
Time |
17:44 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-01-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-01-25 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-01-25 |
Time |
12:56 |
Sent To |
PC |
|
| Notes |
| 2007-01-25 13:04:38 | *** UNSAT 2ND REVIEW** | | | | | | 1) NOTE:PLEASE SEE NOTES FROM PREVIOUS REVIEW. PLANS | | | AND SHEETS FOR EQUIPMENT, LIGHTING FEEDS ETC DO NOT | | | CORRELATE. PLEASE SEE THERE ARE SEVERAL DIFFERENCES. | | | NO GFI PROTECTION, ETC. | | | | | | ** PLEASE CORRELATE ALL SHEETS; PLEASE COMPLETE PLANS | | | FOR 2002 NEC, 215.5, 680, 240.4, 310.16 ETC FOR CODE | | | COMPLIANCE. | | | | | | 2) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | | REPEAT COMMENTS FOR CODE COMPLIANCE. ONE SET OF ELEC IS | | | BEING RETAINED SHEETS 4 AND 5. | | | | | | 3) NOTE:PLEASE KNOW THAT THE PLANS FOR THE ELECTRICAL | | | DETAIL SHALL BE SPECIFIC TO THE SCOPE OF WORK ON THE | | | JOB APPLIED FOR. PLEASE CORRELATE EQUIPMENT WITH NEW | | | PROPOSED PANEL SCHEDULE AS SOME EQUIPMENT SHOWN IS NOT | | | ON SCHEDULE? | | | PLEASE SEE THE PANELS AS SHOWN ON PLANS DO NOT | | | CORRELATE. | | | 408.4, 310.16, | | | FBC 106.1.2 | | | FBC 106.3.5.1.2,106.3.5.5 ADMIN SECTION. | | | | | | 4) NOTE: PLEASE LIST THE FEEDER TO THE NEW VAK-PAK | | | PANEL. | | | 215.5, 215.3. | | | | | | 5) NOTE: PLEASE COMPLETE THE LOAD CALCULATIONS FOR ALL | | | AND INDICATE THE CONTINUOUS LOADS AT 125%. | | | 215.3, 230.42 ETC. | | | ** PLEASE BE SURE TO KEEP ANY SHEETS WHICH CONTAIN | | | PLUMBING STAMPS. | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-11-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-21 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-21 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2006-11-21 16:08:51 | *** UNSAT*** | | | | | | ** PLEASE KNOW PERMIT PACKAGE CONTAIN ONE PLAN FOR | | | COMMERCIAL POOL AND ONE FOR FOUNTAIN. LOCATED THE OTHER | | | SET OF PLANS AND PLACED ALL SETS IN TO EACH OF THEIR | | | RESPECTIVE PACKAGES. | | | | | | 1) NOTE:PLEASE KNOW THAT THE PLANS FOR THE ELECTRICAL | | | DETAIL SHALL BE SPECIFIC TO THE SCOPE OF WORK ON THE | | | JOB APPLIED FOR. PLEASE CORRELATE EQUIPMENT WITH NEW | | | PROPOSED PANEL SCHEDULE AS SOME EQUIPMENT SHOWN IS NOT | | | ON SCHEDULE? | | | 408.4, 310.16, | | | FBC 106.1.2 | | | FBC 106.3.5.1.2,106.3.5.5 ADMIN SECTION. | | | | | | 2) NOTE: PLEASE KNOW AS THIS IS A THRESHOLD/ON-SITE | | | INSPECTOR JOB, THREE SETS OF ALL PLANS MUST BE | | | SUBMITTED. | | | 109.3.6, 106.1.2 ADMIN SECTION. | | | | | | 3) NOTE: PLEASE KNOW THAT NO WHITE OUT OR HAND WRITTEN | | | CHANGES MAY BE DONE TO PLANS WHICH ARE SIGNED, DATED OR | | | SEALED BY AN ENGINEER. | | | PLEASE ALSO SEE THAT ATTACHED SHEETS CHANGING OR | | | MODIFYING PLANS IN ANY WAY IS ALSO NOT PERMITTED UNLESS | | | DONE BY THE ENGINEER OF RECORD, SIGNED, DATED, SEALED | | | ALONG WITH TITLE BLOCKS AS REQUIRED PER FAC | | | 61G15-23.002, FS 471.025 | | | | | | 4) NOTE: PLEASE LIST THE FEEDER TO THE NEW VAK-PAK | | | PANEL. | | | 215.5, 215.3. | | | | | | 5) NOTE: PLEASE COMPLETE THE LOAD CALCULATIONS FOR ALL | | | AND INDICATE THE CONTINUOUS LOADS AT 125%. | | | 215.3, 230.42 ETC. | | | | | | | | | ** PLEASE KNOW AS INFORMATION NEEDED WAS NOT SUBMITTED | | | AT THIS TIME THEIR MAY BE COMMENTS ON THE FOLLOWING | | | REVIEW | | | | | | ** ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | **PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. | | | | | | **IF THERE ARE ANY QUESTIONS, COMMENTSOR IF ANY OF | | | THE NOTES TYPEDWHICH ARE UNCLEAR IN ANY WAY, PLEASE | | | DO NOT HESITATEIN CONTACTING THIS REVIEWER. | | | | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2006-12-21 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-12-21 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2006-12-21 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2006-12-21 15:25:32 | CONTRACTOR INFORMATION | | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL POOL INSPECTION. | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-01-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-17 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-17 |
Time |
11:50 |
Sent To |
Z |
|
| Notes |
| 2007-01-17 11:51:13 | TO "Z" BOX/RESUB--NEW SHEETS FOR Z |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-12-21 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-12-21 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2006-11-13 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2006-11-17 13:12:45 | TO "COMM" BD#14 | | 2006-11-13 11:30:57 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-01-24 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-01-24 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-01-24 |
Time |
11:36 |
Sent To |
|
|
| Notes |
| 2007-01-24 11:47:48 | | | | | | | ****************PROVISO**************** | | | PER FBC-2004 PLUMBING SECTION 802.1.4 SWIMMING POOLS: | | | WHERE WASTEWATER FROM SWIMMING POOLS, BACKWASH FROM | | | FILTERS SHALL DRAIN TO THE SANITARY SYSTEM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-12-21 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-12-21 |
Time |
14:31 |
Rev Time |
1.25 |
| Received By |
mperson |
Date |
2006-12-21 |
Time |
14:31 |
Sent To |
G |
|
| Notes |
| 2006-12-21 15:22:56 | DENIED | | | REFERENCE: FBC-2004, SECTION 424 SWIMMING POOLS AND | | | FLORIDA STATUTES | | | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING | | | PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. PER FBC-2004 CHAPTER 1, SECTION 106.2 AND 109.3.6 | | | THREE SETS OF ALL PLANS AND SUBMITTALS ARE REQUIRED DUE | | | TO THE FACT THAT THE JOB IS A THRESHOLD/ ON SITE | | | INSPECTION JOB. | | | | | | 2. SHEET 4 OF 5 VACUUM FITTING INDICATES (2 TYP) BUT | | | ONLY ONE IS INDICATED ON DRAWINGS, PLEASE CLARIFY ON | | | THE RESUBMITTAL. | | | | | | 3. SHEET 5 OF 5 WHITE OUT OR HAND WRITTEN CHANGES ARE | | | NOT ALLOWED ON SIGNED AND SEALED ENGINEERED PRINTS PER | | | FS 471.025. | | | | | | 4. PER FAC61G15-23.002 AND FS 471.025 ATTACHED SHEETS | | | CHANGING OR MODIFYING PLANS IS NOT PERMITTED UNLESS | | | DONE BY ENGINEER OF RECORD, SIGNED, SEALED, DATED, | | | ALONG WTH A TITLE BLOCK. | | | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-01-22 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-01-22 |
Time |
22:57 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-01-22 |
Time |
22:57 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-11-30 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2006-11-30 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2006-11-30 |
Time |
16:41 |
Sent To |
|
|
| Notes |
|
|