Plan Review Details - Permit 06110263
| Plan Review Stops For Permit 06110263 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2008-03-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-03-31 |
Time |
08:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-03-31 |
Time |
08:11 |
Sent To |
|
|
| Notes |
| 2008-03-31 08:28:01 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.SEE PREVIOUS LISTS REGARDING PROCESS FOR | | | RESUBMITTAL.I WAS UNABLE TO LOCATE A RESPONSE LETTER. | | | THIS EXPEDITES THE REVIEW PROCESS AND HELPS TO PREVENT | | | AN ENTIRELY NEW REVIEW. | | | | | | 2-5.ADDRESSED OR INFORMATIONAL. | | | | | | 6.PLEASE SEE PREVIOUS LISTS REGARDING THE PRESTORM | | | PREPARATION PLAN.USE OF REMOVABLE IMPACT PROTECTION | | | ON COMMERCIAL BUILDINGS REQUIRES APPROVAL BY BUILDING | | | OFFICIAL.A PLAN HAS BEEN SUBMITTED BY THE ARCHITECT, | | | BUT THE AGREEMENT BETWEEN THE OWNER AND DOMINICK | | | MASSERO WAS NOT PROVIDED AS REQUESTED.THE OWNER IS TO | | | SIGN A COMMITMENT REGARDING IMPACT PROTECTION; THIS HAS | | | BEEN REQUESTED BUT NOT PROVIDED. | | | | | | PLEASE NOTE THAT THE PLAN MAY BE SUBMITTED VIA EMAIL | | | FOR PRELIMINARY REVIEW, SEPARATELY FROM THE PLAN REVIEW | | | PROCESS. | | | | | | REGARDING THE PLAN SUBMITTED, PLEASE ADDRESS THE | | | FOLLOWING: | | | | | | A.WHERE SPECIFICALLY WILL THE SHUTTERS BE STORED? | | | WILL THEY BE STORED VERTICALLY OR STACKED ON THE | | | GROUND?IF STORED VERTICALLY, METHOD OF SECURING THE | | | SHUTTERS (TO PREVENT THEM FROM FALLING AND INJURING | | | SOMEONE) WILL BE REQUIRED.IF STORED HORIZONTALLY, A | | | FLOOR PLAN SHOWING THE LOCATION AND ADEQUATE FLOOR | | | SPACE WILL BE REQUIRED.THE FLOOR PLAN ON A2.0 DOES | | | NOT GIVE ANY DIMENSIONS FOR WHAT IS SHOWN AS THE | | | HURRICANE SHUTTER STORAGE AREA. | | | | | | B.HOW WILL THE PANELS BE SECURED TO PREVENT THEFT? | | | WHO HAS ACCESS TO THIS AREA?HOW WILL THE OWNER GET | | | ACCESS TO THIS AREA, ESPECIALLY AS THIS APPEARS TO BE A | | | DIFFERENT TENANT SPACE FROM THE LOCATION WHERE SOME OF | | | THE PANELS WILL BE REQUIRED. | | | | | | C.ONLY ONE INDIVIDUAL IS SHOWN AS BEING RESPONSIBLE | | | FOR THE SHUTTER INSTALLATION.WHAT WILL OWNER DO IN | | | THE EVENT THAT THIS ONE INDIVIDUAL IS UNAVAILABLE | | | (VACATION, ILLNESS)? | | | | | | PLEASE BE ADVISED THAT THIS IS ONLY A PRELIMINARY | | | REVIEW.ONCE COMPLETE INFORMATION IS ESTABLISHED, THE | | | PLAN IS FORWARDED TO THE BUILDING OFFICIAL FOR REVIEW | | | AND APPROVAL. | | | | | | ALSO NOTE THAT, DUE TO FBC1003.6, IMPACT DOORS WILL BE | | | REQUIRED.NOTE THAT YOU ARE PROPOSING TO BLOCK THE | | | ONLY EXIT FOR THE TENANT SPACE NOTED AS 522 S DIXIE HWY | | | | | | | | | 7.SEE PREVIOUS LIST AND ATTACHED SAMPLE INSTALLATION | | | SCHEDULE.THIS INFORMATION IS REQUIRED FOR HURRICANE | | | SHUTTER PERMITS.IF REQUESTED, THIS CAN BE PROVIDED AS | | | A SEPARATE HURRICANE SHUTTER PERMIT. | | | | | | 8.PREVIOUS LIST INDICATED THAT THE NEW ENTRY DID NOT | | | COMPLY WITH FBC11-4.13.6.A 2INCH ELEVATION CHANGE IS | | | SHOWN BETWEEN THE EXISTING SIDEWALK AND FINISHED FLOOR. | | | A NEW NOTE STATES THAT HEIGHT DIFFERENCE SHALL NOT | | | EXCEED 1/2INCH.IT IS NOT CLEAR HOW 1/2INCH AT DOORWAY | | | AND AGAIN FROM NEW SLAB TO SIDEWALK WILL EQUAL THE | | | 2INCH DIFFERENCE.ALSO SEE FBC11-4.5.2, ELEVATION | | | DIFFERENCE IS TO BE LIMITED TO 1/4INCH.SEE | | | FBC11-4.1.6, (1)(B). | | | | | | NEW COMMENTS: | | | | | | 9.A2.0 DECLARES OCCUPANCY AS CLASS B, MERCANTILE. | | | CLASS B IS BUSINESS, MERCANTILE IS CLASS M, 41 | | | OCCUPANTS.IF THIS IS M, GROUND FLOOR REQUIRES 30SF | | | PER PERSON, MINIMUM OCCUPANT LOAD WOULD BE 46.PLANS | | | APPEAR TO BE CODE COMPLIANT FOR OCCUPANT LOAD OF 46 BUT | | | PLEASE EITHER CLARIFY OCCUPANT LOAD OF 41 AS STATED ON | | | PLAN OR REVISE AND CONFIRM COMPLIANCE (NO RESPONSE | | | OTHER THAN REVISION OF OCCUPANT LOAD REQUIRED). | | | PLEASE NOTE THAT, HAD THE PLANS BEEN OTHERWISE CODE | | | COMPLIANT, THIS ITEM WOULD NOT HAVE PREVENTED PERMIT | | | ISSUANCE. | | | | | | 10.FBC1003.6, ITEMS OTHER THAN THOSE ALLOWED IN | | | CHAPTER 10 NOT PERMITTED IN THE EGRESS PATH.HURRICANE | | | PANELS DO NOT COMPLY WITH THIS CODE SECTION.TO MY | | | KNOWLEDGE THE ONLY PROVISION IN THE CODE FOR USE OF | | | SHUTTERS IN EGRESS PATH IN EVENT OF AN EMERGENCY IS FOR | | | RESIDENTIAL OCCUPANCY ONLY.SEE ALSO COMMENT 6, YOU | | | ARE NOT ONLY BLOCKING THE REQUIRED EXIT BUT ALSO | | | BLOCKING WHAT APPEARS TO BE THE ONLY EXIT FOR ONE OF | | | THE TENANT SPACES. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2007-11-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-11-19 |
Time |
14:29 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2007-11-19 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2007-11-19 16:01:34 | PERMIT: 06110263 | | | ADD: 518 S DIXIE HWY | | | CONT: ROOSTH CONSTRUCTION | | | TEL: (561)221-7721 | | | DATE: NOV 19, 2007 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 4THREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2 ) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS | | | NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 3) COMPLIED. | | | | | | 4) COMPLIED. | | | | | | 5) COMMENT NUMBER (5) FROM THE PREVIOUS REVIEW, WPB | | | ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE PRODUCT | | | WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | THE DESIGNER OF RECORD IS TO REVIEW ALL PRODUCT | | | APPROVALS REQUIRED BY RULE 9B-72 PLEASE PROVIDE A SHOP | | | DRAWING STAMP. IF THE DESIGNER OF RECORD WISHES TO MAKE | | | A COVER SHEET LISTING ALL PRODUCTS REVIEWED FOR THIS | | | PROJECT, THEN THIS SHEET WOULD NEED TO BE SIGNED AND | | | SEALED AND DATED. | | | | | | 6) COMMENT NUMBER (6) FROM THE PREVIOUS REVIEW,DEALS | | | WITH THE HURRICANE PREPAREDNESS PLAN. THE ARCHITECT | | | INDICATES BY LETTER HE HAS REVIEWED THE INFORMATION | | | REQUIRED AND FOUND IT TO BE CODE COMPLIANT, BUT HE | | | FAILED TO SIGN AND SEAL SAID LETTER. | | | PLEASE SEE THE PLANS DO NOT INDICATE WHERE UNIT 522 S | | | DIXIE IS OR WHERE THE SHUTTERS WILL BE STORED. | | | WE ALSO FAIL TO SEE A NOTIRIZED LETTER OR ANY CONTRACT | | | BETWEEN THE OWNER AND DOMINICK MASSERO FOR THE | | | INSTALLATION OF SHUTTERS IN THE EVENT THIS COUNTY IS | | | PLACED UNDER A HURRICANE WARNING. | | | | | | IF THE BUILDING IS TO BE STORM SHUTTERED RATHER THAN | | | LARGE IMPACT WINDOWS AND DOORS, THE BUILDING OFFICIALS | | | INTERPRETATION | | | OF THE CODE REQUIRES A HURRICANE PREPAREDNESS PLAN WITH | | | THE FOLLOWING:104.6*/ 1609.1.4/ 1714.5 STANDARDS FOR | | | WIND-BORNE DEBRIS IMPACT PROTECTION | | | QUESTION# 13 RECOGNIZING SUCH CONCERNS AS ABSENTEE | | | OWNERS, OR CASES WHERE LONGER TIME & EFFORT IS | | | NECESSARY TO SECURE SHUTTERS ON LARGE OR MULTI-STORY | | | BUILDINGS, WHAT MEASURES ARE BEING RECOMMENDED OR | | | IMPLEMENTED TO ENSURE THAT COMPLETE INSTALLATION OR | | | SECURING IS DONE SUFFICIENTLY IN ADVANCE OF THE | | | HURRICANE? | | | | | | IN MATTERS CONCERNING PUBLIC SAFETY, HEALTH, AND THE | | | GENERAL WELFARE NOT SPECIFICALLY ADDRESSED IN THE CODE, | | | SECTION 104.6 OF THE FLORIDA BUILDING CODE,BUILDING, | | | CHAPTER 1, | | | ADMINISTRATIVE CODE2004 EDITION AS AMENDED BY THE CITY | | | OF WEST PALM BEACH, PROVDES THE ABILITY FOR THE | | | BUILDING OFFICIAL TO IMPLEMENT REQUIREMENTS FOR | | | ENSURING STABILITY, STRENGTH, AND THE PROPER OPERATION | | | OF EXISTING BUILDINGS. | | | | | | IN ORDER TO ASSURE THE SECURING OF SHUTTERS ON LARGE OR | | | MULTI-STORY BUILDINGS, OR MULTIPLE BUILDINGS ON THE | | | SAME PROPERTY, PRE-STORM PREPARATION PLANS MUST BE | | | SUBMITTED BY THE PROPERTY OWNERS OR MANAGING AGENTS FOR | | | REVIEW BY THE CONSTRUCTION SRVICES DEPARTMENT. ANY SUCH | | | PLAN SHALL INCLUDE, AT A MINMUM, ON SITE LOCATION OF | | | THE SHUTTERS, PARTY RESPONSIBLE FOR SECURING THE | | | SHUTTERS ( SAID PARTY MUST BE LOCATED WITHIN PALM BEACH | | | COUNTY), TOTAL NUMBER OF OPENINGS TO BE PROTECTED AND | | | THE TOTAL TIME REQUIRED TO SECURE ALL OPENINGS. | | | PROTECTION OF OPENINGS SHALL BE ACCOMPLISHEDWITHIN | | | TWELVE (12) HOURS OR LESS OF THE | | | OFFICIAL NOTIFICATION BY THE NATIONAL WEATHER SERVICES | | | OF A HURRICANE WATCH. | | | | | | PROVISIONS IN THE BUILDING CODES (AND THIS STANDARD) | | | ARE NOT INTENDED TO PROHIBIT THE USE OF ALTERNATE | | | MATERIALS AND METHODS, AND THE BUILDING OFFICIAL TO | | | REVIEW AND APPROVE ANY ALTERNATE DEEMED EQUIVALENT IN | | | QUALITY, STRENGTH, EFFECTIVENESS, FIRE RESISTANCE, | | | DURABILITY AND SAFETY PRESCRIBED BY THIS CODE. BASED | | | UPON THIS CODE PROVISION, ACCEPTANCE OF ALTERNATE | | | MATERIALS AND METHODS MAY BE APPROVED ON A CASE-BY-CASE | | | BASIS AND SHALL REQUIRE SUFFICIENT EVIDENCE OR PROOF TO | | | SUBSTANTIATE ANY CLAIM MADE REGARDING THE ALTERNATE. | | | | | | 7) COMMENT# 7 FROM THE PREVIOUS REVIEW,DEALS WITH A | | | KET PLAN INDICATING THE LOCATION OF THE OPENING, AND | | | HIGHLIGHTING THE TYPE OF SHUTTER APPLICATION USED IN | | | THE INSTALATION, NOR HAS THE TYPE OF FASTENER HIGH | | | LIGHTED AND SPACING REQUIREMENTS AS SPECIFIED BELOW. | | | PLEASE TAKE THE TIME TO CREATE A SCHEDULE THAT WILL | | | CONFORM TO THE CITYS' REQUIREMENTS. | | | STORM SHUTTER REQUIREMENTS: 2004FL BLD CODE 2001 | | | SECTION 104.6, 1609.1.4& 1714.5PROVIDE STORM PANEL | | | INFORMATION WITH INSTALLATION SCHEDULE AND KEY PLAN | | | WITH SPECIFIC ANCHORS AND MOUNTING TO BE USED FOR ALL | | | NON-IMPACT GLAZING. | | | FBC 1609.1.4. | | | PROCEDURES: 1(B) A COMPLETE INSTALLATION | | | SCHEDULE SUMMARIZING & IDENTIFYING | | | OPENING SIZES, STORY HEIGHTS, UNIT MARK | | | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM | | | BAR REINFORCING REQUIREMENTS, WALL PRES- | | | SURE ZONES, SLAT TYPES, ETC., SHALL BE | | | SUBMITTED AT TIME OF PERMIT APPLICATION | | | TO FACILITATE PLAN REVIEW AND PERMIT | | | ISSUANCE.SEE ATTACHED EXAMPLE. | | | | | | 8)NEW COMMENT, THE NEW FRONT ENTRYS DO NOT MEET THE | | | REQUIREMENTS FOR CLEAR FLOOR SPACE AT DOORWAYS. | | | 11-4.13.6 MANEUVERING CLEARENCES AT DOORS. MINIMUM | | | MANEUVERING CLEARANCES AT DOORS THAT ARE NOT AUTOMATIC | | | OR POWER-ASSISTED SHALL BE AS SHOWN IN FIG. 25. THE | | | FLOOR OR GROUND AREA WITH IN THE REQUIRED CLEARANCES | | | SHALL BE CLEAR & LEVEL. | | | | | | | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-06-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-06-15 |
Time |
16:09 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2007-06-15 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2007-06-15 16:09:41 | PERMIT: 06110263 | | | ADD: 518 S DIXIE HWY | | | CONT: ROOSTH CONSTRUCTION | | | TEL: (561)221-7721 | | | | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RDREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2 ) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS | | | NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 3) COMMENT NUMBER 5FROM THE PREVIOUS RVIEW,PRODUCT | | | APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 4) COMMENT NUMBER (6A) FROM THE PREVIOUS REVIEW, FL BLD | | | CODE 1609.1.4: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) STOREFRONTWINDOWS REPORT ILLEGABLE PLEASE PROVIDE | | | LEGIBLE REPORTS | | | B) EXTERIOR GLAZED DOORS INDICATE OUTSWING WHILE THE | | | PLANS INDICATE INSWING | | | C) MULLIONS | | | D) TRANSOMS | | | E) SHUTTERS SEE ADDITIONAL INFORMATION REQUIRED SEE | | | COMMENT # 6. | | | | | | 5) COMMENT NUMBER 6B FROM THE PREVIOUS REVIEW, | | | WPB ADMIN CODE 106.3* PRODUCT | | | APPROVALS. THOSE PRODUCT WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | 6) COMMENT NUMBER 7 FROM THE PREVIOUS REVIEW,IF THE | | | BUILDING IS TO BE STORM SHUTTERED RATHER THAN LARGE | | | IMPACT WINDOWS AND DOORS, THE BUILDING OFFICIALS | | | INTERPRETATION | | | OF THE CODE REQUIRES A HURRICANE PREPAREDNESS PLAN WITH | | | THE FOLLOWING:104.6*/ 1609.1.4/ 1714.5 STANDARDS FOR | | | WIND-BORNE DEBRIS IMPACT PROTECTION | | | QUESTION# 13 RECOGNIZING SUCH CONCERNS AS ABSENTEE | | | OWNERS, OR CASES WHERE LONGER TIME & EFFORT IS | | | NECESSARY TO SECURE SHUTTERS ON LARGE OR MULTI-STORY | | | BUILDINGS, WHAT MEASURES ARE BEING RECOMMENDED OR | | | IMPLEMENTED TO ENSURE THAT COMPLETE INSTALLATION OR | | | SECURING IS DONE SUFFICIENTLY IN ADVANCE OF THE | | | HURRICANE? | | | | | | IN MATTERS CONCERNING PUBLIC SAFETY, HEALTH, AND THE | | | GENERAL WELFARE NOT SPECIFICALLY ADDRESSED IN THE CODE, | | | SECTION 104.6 OF THE FLORIDA BUILDING CODE,BUILDING, | | | CHAPTER 1, | | | ADMINISTRATIVE CODE2004 EDITION AS AMENDED BY THE CITY | | | OF WEST PALM BEACH, PROVDES THE ABILITY FOR THE | | | BUILDING OFFICIAL TO IMPLEMENT REQUIREMENTS FOR | | | ENSURING STABILITY, STRENGTH, AND THE PROPER OPERATION | | | OF EXISTING BUILDINGS. | | | | | | IN ORDER TO ASSURE THE SECURING OF SHUTTERS ON LARGE OR | | | MULTI-STORY BUILDINGS, OR MULTIPLE BUILDINGS ON THE | | | SAME PROPERTY, PRE-STORM PREPARATION PLANS MUST BE | | | SUBMITTED BY THE PROPERTY OWNERS OR MANAGING AGENTS FOR | | | REVIEW BY THE CONSTRUCTION SRVICES DEPARTMENT. ANY SUCH | | | PLAN SHALL INCLUDE, AT A MINMUM, ON SITE LOCATION OF | | | THE SHUTTERS, PARTY RESPONSIBLE FOR SECURING THE | | | SHUTTERS ( SAID PARTY MUST BE LOCATED WITHIN PALM BEACH | | | COUNTY), TOTAL NUMBER OF OPENINGS TO BE PROTECTED AND | | | THE TOTAL TIME REQUIRED TO SECURE ALL OPENINGS. | | | PROTECTION OF OPENINGS SHALL BE ACCOMPLISHEDWITHIN | | | TWELVE (12) HOURS OR LESS OF THE | | | OFFICIAL NOTIFICATION BY THE NATIONAL WEATHER SERVICES | | | OF A HURRICANE WATCH. | | | | | | PROVISIONS IN THE BUILDING CODES (AND THIS STANDARD) | | | ARE NOT INTENDED TO PROHIBIT THE USE OF ALTERNATE | | | MATERIALS AND METHODS, AND THE BUILDING OFFICIAL TO | | | REVIEW AND APPROVE ANY ALTERNATE DEEMED EQUIVALENT IN | | | QUALITY, STRENGTH, EFFECTIVENESS, FIRE RESISTANCE, | | | DURABILITY AND SAFETY PRESCRIBED BY THIS CODE. BASED | | | UPON THIS CODE PROVISION, ACCEPTANCE OF ALTERNATE | | | MATERIALS AND METHODS MAY BE APPROVED ON A CASE-BY-CASE | | | BASIS AND SHALL REQUIRE SUFFICIENT EVIDENCE OR PROOF TO | | | SUBSTANTIATE ANY CLAIM MADE REGARDING THE ALTERNATE. | | | | | | 7) COMMENT# 8 FROM THE PREVIOUS REVIEW,STORM SHUTTER | | | REQUIREMENTS: 2004FL BLD CODE 2001 SECTION 104.6, | | | 1609.1.4& 1714.5PROVIDE STORM PANEL INFORMATION | | | WITH INSTALLATION SCHEDULE AND KEY PLAN WITH SPECIFIC | | | ANCHORS AND MOUNTING TO BE USED FOR ALL NON-IMPACT | | | GLAZING. | | | FBC 1609.1.4. | | | PROCEDURES: 1(B) A COMPLETE INSTALLATION | | | SCHEDULE SUMMARIZING & IDENTIFYING | | | OPENING SIZES, STORY HEIGHTS, UNIT MARK | | | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM | | | BAR REINFORCING REQUIREMENTS, WALL PRES- | | | SURE ZONES, SLAT TYPES, ETC., SHALL BE | | | SUBMITTED AT TIME OF PERMIT APPLICATION | | | TO FACILITATE PLAN REVIEW AND PERMIT | | | ISSUANCE.SEE ATTACHED EXAMPLE. | | | | | | 8) REVIEW COMMENT FOR 3900 N FLAGLERLATITE ROOFING? | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-02-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-02-09 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2007-02-09 |
Time |
07:50 |
Sent To |
|
|
| Notes |
| 2007-02-09 08:02:01 | BUILDING PLAN REVIEW | | | PERMIT: 06110263 | | | ADD: 518 S DIXIE HWY | | | CONT: ROOSTH CONSTRUCTION | | | TEL: (561)221-7721 | | | | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2NDREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2 ) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS | | | NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 3) PLEASE PROVIDE A SURVEY WITH THE BUILDING LOCATION | | | ON SURVEY. | | | 3202.2 ENCROACHMENTS ABOVE GRADE AND BELOW 8 FEET IN | | | HEIGHT. | | | ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY ABOVE GRADE | | | AND BELOW | | | 8 FEET (2438 MM) IN HEIGHT SHALL BE PROHIBITED EXCEPT | | | AS PROVIDED FOR | | | IN SECTIONS 3202.2.1 THROUGH 3202.2.3 . DOORS AND | | | WINDOWS SHALL NOT | | | OPEN OR PROJECT INTO THE PUBLIC RIGHT-OF-WAY. | | | | | | 4)110.2* W. P. B. ADMINISTRATIVE | | | CODE, INFORMATION THAT IS REQUIRED FOR | | | RECORD KEEPING & FOR CERTIFICATE OF | | | OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. | | | THE COVERSHEET STILL REFLECTS THE 2001 FBC IN THE | | | GENERAL NOTES# 01 | | | | | | 5) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 6A) FL BLD CODE 1609.1.4: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) STOREFRONT | | | B) EXTERIOR DOORS | | | C) MULLIONS | | | D) TRANSOMS | | | E) SHUTTERS | | | 6B) WPB ADMIN CODE 106.3* PRODUCT | | | APPROVALS. THOSE PRODUCT WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | 7) IF THE BUILDING IS TO BE STORM SHUTTERED RATHER | | | THAN | | | LARGE IMPACT WINDOWS AND DOORS, THE BUILDING OFFICIALS | | | INTERPRETATION | | | OF THE CODE REQUIRES A HURRICANE PREPAREDNESS PLAN WITH | | | THE FOLLOWING:104.6*/ 1609.1.4/ 1714.5 STANDARDS FOR | | | WIND-BORNE DEBRIS IMPACT PROTECTION | | | QUESTION# 13 RECOGNIZING SUCH CONCERNS AS ABSENTEE | | | OWNERS, OR CASES WHERE LONGER TIME & EFFORT IS | | | NECESSARY TO SECURE SHUTTERS ON LARGE OR MULTI-STORY | | | BUILDINGS, WHAT MEASURES ARE BEING RECOMMENDED OR | | | IMPLEMENTED TO ENSURE THAT COMPLETE INSTALLATION OR | | | SECURING IS DONE SUFFICIENTLY IN ADVANCE OF THE | | | HURRICANE? | | | | | | IN MATTERS CONCERNING PUBLIC SAFETY, HEALTH, AND THE | | | GENERAL WELFARE NOT SPECIFICALLY ADDRESSED IN THE CODE, | | | SECTION 104.6 OF THE FLORIDA BUILDING CODE,BUILDING, | | | CHAPTER 1, | | | ADMINISTRATIVE CODE2004 EDITION AS AMENDED BY THE CITY | | | OF WEST PALM BEACH, PROVDES THE ABILITY FOR THE | | | BUILDING OFFICIAL TO IMPLEMENT REQUIREMENTS FOR | | | ENSURING STABILITY, STRENGTH, AND THE PROPER OPERATION | | | OF EXISTING BUILDINGS. | | | | | | IN ORDER TO ASSURE THE SECURING OF SHUTTERS ON LARGE OR | | | MULTI-STORY BUILDINGS, OR MULTIPLE BUILDINGS ON THE | | | SAME PROPERTY, PRE-STORM PREPARATION PLANS MUST BE | | | SUBMITTED BY THE PROPERTY OWNERS OR MANAGING AGENTS FOR | | | REVIEW BY THE CONSTRUCTION SRVICES DEPARTMENT. ANY SUCH | | | PLAN SHALL INCLUDE, AT A MINMUM, ON SITE LOCATION OF | | | THE SHUTTERS, PARTY RESPONSIBLE FOR SECURING THE | | | SHUTTERS ( SAID PARTY MUST BE LOCATED WITHIN PALM BEACH | | | COUNTY), TOTAL NUMBER OF OPENINGS TO BE PROTECTED AND | | | THE TOTAL TIME REQUIRED TO SECURE ALL OPENINGS. | | | PROTECTION OF OPENINGS SHALL BE ACCOMPLISHEDWITHIN | | | TWELVE (12) HOURS OR LESS OF THE | | | OFFICIAL NOTIFICATION BY THE NATIONAL WEATHER SERVICES | | | OF A HURRICANE WATCH. | | | | | | PROVISIONS IN THE BUILDING CODES (AND THIS STANDARD) | | | ARE NOT INTENDED TO PROHIBIT THE USE OF ALTERNATE | | | MATERIALS AND METHODS, AND THE BUILDING OFFICIAL TO | | | REVIEW AND APPROVE ANY ALTERNATE DEEMED EQUIVALENT IN | | | QUALITY, STRENGTH, EFFECTIVENESS, FIRE RESISTANCE, | | | DURABILITY AND SAFETY PRESCRIBED BY THIS CODE. BASED | | | UPON THIS CODE PROVISION, ACCEPTANCE OF ALTERNATE | | | MATERIALS AND METHODS MAY BE APPROVED ON A CASE-BY-CASE | | | BASIS AND SHALL REQUIRE SUFFICIENT EVIDENCE OR PROOF TO | | | SUBSTANTIATE ANY CLAIM MADE REGARDING THE ALTERNATE. | | | | | | 8) STORM SHUTTER REQUIREMENTS: | | | 2004FL BLD CODE 2001 SECTION 104.6, | | | 1609.1.4& 1714.5PROVIDE STORM PANEL INFORMATION | | | WITH INSTALLATION SCHEDULE AND KEY PLAN WITH SPECIFIC | | | ANCHORS AND MOUNTING TO BE USED | | | FOR ALL NON-IMPACT GLAZING. | | | FBC 1609.1.4. | | | PROCEDURES: 1(B) A COMPLETE INSTALLATION | | | SCHEDULE SUMMARIZING & IDENTIFYING | | | OPENING SIZES, STORY HEIGHTS, UNIT MARK | | | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM | | | BAR REINFORCING REQUIREMENTS, WALL PRES- | | | SURE ZONES, SLAT TYPES, ETC., SHALL BE | | | SUBMITTED AT TIME OF PERMIT APPLICATION | | | TO FACILITATE PLAN REVIEW AND PERMIT | | | ISSUANCE.SEE ATTACHED EXAMPLE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-12-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-12-14 |
Time |
11:41 |
Rev Time |
1.77 |
| Received By |
jwitmer |
Date |
2006-12-14 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2006-12-14 15:10:49 | BUILDING PLAN REVIEW | | | PERMIT: 06110263 | | | ADD: 518 S DIXIE HWY | | | CONT: ROOSTH CONSTRUCTION | | | TEL: (561)221-7721 | | | | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1STREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2 ) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS | | | NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 3) PLEASE PROVIDE A SURVEY WITH THE BUILDING LOCATION | | | ON SURVEY. | | | 3202.2 ENCROACHMENTS ABOVE GRADE AND BELOW 8 FEET IN | | | HEIGHT. | | | ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY ABOVE GRADE | | | AND BELOW | | | 8 FEET (2438 MM) IN HEIGHT SHALL BE PROHIBITED EXCEPT | | | AS PROVIDED FOR | | | IN SECTIONS 3202.2.1 THROUGH 3202.2.3 . DOORS AND | | | WINDOWS SHALL NOT | | | OPEN OR PROJECT INTO THE PUBLIC RIGHT-OF-WAY. | | | | | | 4)110.2* W. P. B. ADMINISTRATIVE | | | CODE, INFORMATION THAT IS REQUIRED FOR | | | RECORD KEEPING & FOR CERTIFICATE OF | | | OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. | | | B(1) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | B(2)IS THIS A CHANGE OF OCCUPANCY? | | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6, TABLE 601. | | | D) THE OCCUPANT LOAD, SEE 1004. | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | | IS REQUIRED. | | | F) ANY SPECIAL STIPULATIONS & CONDITIONS | | | OF THE BUILDING PERMIT. | | | | | | 5) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 6) FL BLD CODE 1609.1.4: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) STOREFRONT | | | B) EXTERIOR DOORS | | | C) MULLIONS | | | D) TRANSOMS | | | E) SHUTTERS | | | | | | 7) IF THE BUILDING IS TO BE STORM SHUTTERED RATHER | | | THAN | | | | | | LARGE IMPACT WINDOWS AND DOORS, THE BUILDING OFFICIALS | | | INTERPRETATION | | | OF THE CODE REQUIRES A HURRICANE PREPAREDNESS PLAN WITH | | | THE FOLLOWING:104.6*/ 1609.1.4/ 1714.5 STANDARDS FOR | | | WIND-BORNE DEBRIS IMPACT PROTECTION | | | QUESTION# 13 RECOGNIZING SUCH CONCERNS AS ABSENTEE | | | OWNERS, OR CASES WHERE LONGER TIME & EFFORT IS | | | NECESSARY TO SECURE SHUTTERS ON LARGE OR MULTI-STORY | | | BUILDINGS, WHAT MEASURES ARE BEING RECOMMENDED OR | | | IMPLEMENTED TO ENSURE THAT COMPLETE INSTALLATION OR | | | SECURING IS DONE SUFFICIENTLY IN ADVANCE OF THE | | | HURRICANE? | | | | | | IN MATTERS CONCERNING PUBLIC SAFETY, HEALTH, AND THE | | | GENERAL WELFARE NOT SPECIFICALLY ADDRESSED IN THE CODE, | | | SECTION 104.6 OF THE FLORIDA BUILDING CODE,BUILDING, | | | CHAPTER 1, | | | ADMINISTRATIVE CODE2004 EDITION AS AMENDED BY THE CITY | | | OF WEST PALM BEACH, PROVDES THE ABILITY FOR THE | | | BUILDING OFFICIAL TO IMPLEMENT REQUIREMENTS FOR | | | ENSURING STABILITY, STRENGTH, AND THE PROPER OPERATION | | | OF EXISTING BUILDINGS. | | | | | | IN ORDER TO ASSURE THE SECURING OF SHUTTERS ON LARGE OR | | | MULTI-STORY BUILDINGS, OR MULTIPLE BUILDINGS ON THE | | | SAME PROPERTY, PRE-STORM PREPARATION PLANS MUST BE | | | SUBMITTED BY THE PROPERTY OWNERS OR MANAGING AGENTS FOR | | | REVIEW BY THE CONSTRUCTION SRVICES DEPARTMENT. ANY SUCH | | | PLAN SHALL INCLUDE, AT A MINMUM, ON SITE LOCATION OF | | | THE SHUTTERS, PARTY RESPONSIBLE FOR SECURING THE | | | SHUTTERS ( SAID PARTY MUST BE LOCATED WITHIN PALM BEACH | | | COUNTY), TOTAL NUMBER OF OPENINGS TO BE PROTECTED AND | | | THE TOTAL TIME REQUIRED TO SECURE ALL OPENINGS. | | | PROTECTION OF OPENINGS SHALL BE ACCOMPLISHEDWITHIN | | | TWELVE (12) HOURS OR LESS OF THE | | | OFFICIAL NOTIFICATION BY THE NATIONAL WEATHER SERVICES | | | OF A HURRICANE WATCH. | | | | | | PROVISIONS IN THE BUILDING CODES (AND THIS STANDARD) | | | ARE NOT INTENDED TO PROHIBIT THE USE OF ALTERNATE | | | MATERIALS AND METHODS, AND THE BUILDING OFFICIAL TO | | | REVIEW AND APPROVE ANY ALTERNATE DEEMED EQUIVALENT IN | | | QUALITY, STRENGTH, EFFECTIVENESS, FIRE RESISTANCE, | | | DURABILITY AND SAFETY PRESCRIBED BY THIS CODE. BASED | | | UPON THIS CODE PROVISION, ACCEPTANCE OF ALTERNATE | | | MATERIALS AND METHODS MAY BE APPROVED ON A CASE-BY-CASE | | | BASIS AND SHALL REQUIRE SUFFICIENT EVIDENCE OR PROOF TO | | | SUBSTANTIATE ANY CLAIM MADE REGARDING THE ALTERNATE. | | | | | | 8) STORM SHUTTER REQUIREMENTS: | | | 2004FL BLD CODE 2001 SECTION 104.6, | | | 1609.1.4& 1714.5PROVIDE STORM PANEL INFORMATION | | | WITH INSTALLATION SCHEDULE AND KEY PLAN WITH | | | SPECIFIC ANCHORS AND MOUNTING TO BE USED | | | FOR ALL NON-IMPACT GLAZING. | | | FBC 1609.1.4. | | | PROCEDURES: 1(B) A COMPLETE INSTALLATION | | | SCHEDULE SUMMARIZING & IDENTIFYING | | | OPENING SIZES, STORY HEIGHTS, UNIT MARK | | | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM | | | BAR REINFORCING REQUIREMENTS, WALL PRES- | | | SURE ZONES, SLAT TYPES, ETC., SHALL BE | | | SUBMITTED AT TIME OF PERMIT APPLICATION | | | TO FACILITATE PLAN REVIEW AND PERMIT | | | ISSUANCE.SEE ATTACHED EXAMPLE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2008-03-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-03-08 |
Time |
20:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-03-08 |
Time |
20:47 |
Sent To |
|
|
| Notes |
| 2008-03-08 20:47:54 | ** DENIED REVIEW ** | | | | | | 1) NOTE: PLEASE SEE PREVIOUS REVIEW NOTES WITH RESPECT | | | TO LIGHTING POWER DENSITIES. 13-415.2..ABC.1.1, .1.2 | | | AND .1.3, AND 13-415.2 | | | PLEASE SEE THE ALLOWANCES SUBMITTED STATE LOW BAY | | | FIXTURES, WHEN THE FIXTURES ON PLANS ARE NOT LOW BAY | | | FIXTURES. IN EITHER CASE PLEASE SEE THE DESIGN WATTAGE | | | AS SHOWN EXCEEDS ALLOWANCES AS SHOW IN 13-415.2.B. | | | PLEASE SEE PLANS SHOWS 1.2, WHICH EVEN IN ACTIVE | | | STORAGE ON THIS TABLE ALLOWS ONLY .8. | | | PLEASE SEE 13-415.2.ABC.1.3 FOR EXTERIOR. | | | AS THE TOTAL FOR INTERIOR STILL SEEMS TO FALL BELOW THE | | | OVER ALL ALLOWANCE SHOULD BE OK. | | | | | | ** PLEASE KNOW ONLY IF ALL OTHER TRADE REVIEWS PASS | | | THAT A CONDITION KNOWN AS A *PROVISO* MAY BE ISSUED | | | WHICH WILL REQUIRE REVISED PLANS BEFORE ROUGH. | | | | | | 2) NOTE:** PLEASE SEE AS REQUESTED AND NOTED ON | | | PREVIOUS REVIEW, PLEASE DO NOT LEAVE OLD/VOIDED SHEETS | | | IN SETS. PLEASE REMOVE AND LABEL OLD/VOID | | | | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-11-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-27 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-26 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2007-11-27 08:26:20 | ** DENIED** | | | | | | | | | | | | 1) NOTE:PLEASE PROVIDE LIGHTING POWER DENSITIES PER | | | 13-415.2. MAY NOT USE METHOD A FOR *WHOLE BUILDING* AS | | | THIS IS NOT A WHOLE BUILDING WHICH IS BEING BROUGHT UP | | | TO CODE. | | | PLEASE KNOW THIS WAS CONFIRMED ON SEPT 26, 2007 WITH | | | THE STATE OF FLORIDA, FLORIDA BUILDING COMMISSION. | | | THE ENERGY CALCULATIONS SUBMITTED BACK WERE THE SAME | | | FROM PREVIOUS REVIEW WHICH HAD COMMENTS FOR | | | COORDINATION. | | | PLEASE KNOW ONLY LIGHTING PERFORMANCE CALCULATIONS NEED | | | BE SUBMITTED FOR ELECTRICAL. PLEASE CALL TO GO OVER | | | THIS MAY BE DONE IF THERE ARE ANY QUESTIONS. | | | PLANS ARE ALREADY COMING BACK FOR COMMENTS FROM OTHER | | | TRADES. | | | | | | PLEASE KNOW, STRUCTURAL REVIEW WILL BE DONE BY BUILDING | | | REVIEWER. | | | PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-04-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-04-25 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-04-25 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2007-04-25 15:24:23 | ** UNSAT3RD REVIEW** | | | | | | 1) NOTE: PLEASE SEE THE NUMBER OF WINDOW RECEPTACLES IS | | | NOT COMPLIANT AT THIS TIME. PLEASE SEE THE NORTH WINDOW | | | WHICH SCALES TO BE LONGER THAN 12FT WHICH WOULD REQUIRE | | | ONE ADDITIONAL RECEPTACLE. | | | PLEASE ALSO SEE THE SOUTH WINDOW WHICH DOES NOT CONTAIN | | | ANY DEVICE. | | | THESE COULD BE REDLINED ON PLANS ONCE THE FOLLOWING | | | COMMENT IS ADDRESSED. | | | | | | 2) NOTE: PLEASE CORRELATE THE ENERGY CALCULATIONS FOR | | | USE AND TYPE OF LIGHTING. (NOT LOW BAY MANUFACTURING). | | | PLEASE ALSO SEE THE NUMBER OF FIXTURES SHOWN PLANS, THE | | | WATTAGE AND THE TYPES OF FIXTURES DO NOT CORRELATE WITH | | | THE PLANS AND FIXTURES AS SHOWN ON PLANS. | | | PLEASE SEE THIS IS A NEW COMMENT AS THIS IS THE FIRST | | | TIME ENERGY CALCULATIONS WERE SUBMITTED FOR REVIEW. | | | PLEASE COORDINATE ALL FIXTURES, WATTAGES, TYPES, USE. | | | 13-415.1.A | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-01-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-01-19 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-01-19 |
Time |
12:05 |
Sent To |
|
|
| Notes |
| 2007-01-19 17:25:49 | ** UNSAT2ND REVIEW ** | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW STILL | | | NEED TO BE ADDRESSED ALONG WITH SOME NEW COMMENTS BASED | | | ON CHANGES MADE TO PLANS. | | | PLEASE KNOW THAT THERE NEW COMMENTS BASED ON PLANS AND | | | CHANGES MADE. | | | | | | ** PLEASE SEE THE COMMENTS BELOW ARE TAKEN DIRECTLY | | | FROM PREVIOUS REVIEW IN THE SAME NUMERICAL ORDER. THEY | | | WILL CONTAIN A NO, OK, OR NO/OK. | | | A) NO WILL BE FOLLOWED BY FURTHER EXPLANATION OF THE | | | PREVIOUS COMMENT. | | | B) OK, MAY REFERENCE TO ANY NEW NOTES, HOWEVER WILL | | | HAVE PREVIOUS NOTE REMOVED. | | | C) NO/OK, WILL BE FOLLOWED BY FURTHER EXPLANATION AS | | | PART OF THE COMMENT MAY NOT HAVE BEEN ADDRESSED FULLY | | | AND PART OF THE PREVIOUS COMMENT MAY BE OK. | | | D) OK/N/A, AS THE PREVIOUS NOTE DOES NOT APPLY ANY | | | FURTHER AS PLANS HAVE DELETED OR CHANGED. | | | | | | ** ANY NEW NOTES WILL BE AT THE BOTTOM AND IDENTIFIED | | | AS *** NEW NOTES ***. | | | | | | 1) NOTE: NO/OK, PLEASE SEE SHEETS WHICH STILL INDICATE | | | THE 2001 FBC. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE PLANS REFLECT THE 2001 FBC; HOWEVER AS OF | | | OCT 1ST, 2005 THE STATE OF FLORIDA ADOPTED THE 2004 | | | FBC. PLEASE ADJUST AND CHANGE AS NEED. | | | PLEASE ALSO SEE TWO SEPARATE LS CODES ARE REFERENCED ON | | | PLANS. (2000& 2003). | | | PLEASE SEE OTHER LOCATIONS WHERE THE PLANS REFLECT THE | | | "LATEST ADOPTED" ETC. | | | PLEASE BE SURE THE FOLLOWING CODES ARE REFLECTED ON | | | PLANS AS REQUIRED. | | | 2002 NFPA-70 (NEC), 2003 NFPA-101 (LS), 2004 FBC, AND | | | ANY OTHER CODES FROM OTHER TRADES. SEE COMMENTS FROM | | | OTHER REVIEWERS. | | | | | | 2) NOTE: OK, HOWEVER SEE NEW NOTES. | | | | | | 3) NOTE: OK/NO, PLEASE SEE THE OUTLET AND THE CIRCUIT | | | WAS ADDED, HOWEVER PLEASE SEE THE LOCATION SHOULD BE | | | SHOWN INSIDE OR OUTSIDE THE NEAREST POINT OF ENTRANCE. | | | PLEASE SEE THAT PLANS ONLY NEED TO RELOCATE THIS OVER. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE INDICATE A NEW OR EXISTING SIGN CIRCUIT(S) PEER | | | 600.5 THIS SPACE AND THE SPACE NEXT DOOR AS SCOPE OF | | | WORK ON ARCHITECTURAL PLANS INDICATE WORK BEING DONE ON | | | THE STOREFRONT NEXT DOOR. | | | FBC 106.1.2 ADMIN SECT. | | | | | | 4) NOTE: OK. | | | | | | 5) NOTE:NO, PLEASE SEE SOME ADDED, HOWEVER NOT ALL AS | | | REQUIRED. PLEASE SEE INDIVIDUAL SPACES AND WINDOWS | | | WHICH EXCEED 12 LINEAR FT WILL BE REQUIRED TO CONTAIN | | | ADDITIONAL RECEPTS. | | | PLEASE ALSO SEE THE SECTION OF CODE GIVEN FOR LOAD | | | CALCULATIONS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE MISSING SHOW WINDOW RECEPTS AS REQUIRED PER | | | 210.62 AND PLEASE ADJUST LOAD CALCULATIONS AS REQUIRED. | | | 220.12 | | | | | | 6) NOTE: OK. NO OTHER TENANT SPACE WILL BE FED FROM | | | THIS METER/SERVICE. | | | PLEASE SEE SERVICE NOTE AS THE SERVICE IS NOT CLEAR FOR | | | FUTURE TENANT. | | | | | | 7) NOTE: OK. | | | | | | 8) NOTE: OK. | | | | | | 9) NOTE:OK/NO, PLEASE SEE THE FUTURE TENANT SPACE(S) | | | WHICH WILL A PART OF THIS BUILDING WILL NOT BE GRANTED | | | AN ADDITIONAL SERVICE PER 230.2. THE RISER DOES NOT | | | INDICATE ANY PROVISIONS FOR THIS POSSIBLE FUTURE TENANT | | | AND THE NEW RISER WHICH IS BEING PROPOSED WOULD HAVE TO | | | BE UPGRADED TO ACCOMMODATE THIS IN THE FUTURE. THE | | | 2-STORY BUILDING TO THE NORTH OF THE SINGLE STORY | | | BUILDING WITH THE MULTIPLE METERED SERVICES MAY NOT | | | FEED THIS FUTURE TENANT. BASED ON THE CONSTRUCTION AT | | | THE SITE AND THE AERIALS, THIS TWO STRUCTURES APPEAR TO | | | CONTAIN A FIRE WALL WHICH PENETRATES THE ROOF LINE AND | | | SEPARATES THESE TWO AS BUILDINGS AS DEFINED IN THE | | | FBC. | | | | | | PLEASE KNOW BASED ON THE SERVICE AS SHOWN THIS WILL | | | ONLY BE ONE TENANT AND UNLESS UPGRADING THE NEW | | | PROPOSED SERVICE IN THE FUTURE, NO OTHER SEPARATE | | | TENANTS WILL OCCUPY FUTURE SPACE OR THE SPACE NOT BEING | | | BUILT OUT AT THIS TIME. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE CORRELATE SERVICE AS SHOWN ON PLANS AND THAT OF | | | WHICH IS BEING SHOWN ON RISER. IF SERVICE IS GOING TO | | | BE NEW AS SHOWN ON RISER, PLEASE SHOW. PLEASE VERIFY | | | WHERE THE REST OF THE SERVICE IS FOR FEEDING THE | | | BUILDING. PLEASE SEE 230.2, 230.72 FOR SERVICES | | | PERMITTED, AND GROUPING. | | | PLEASE SEE PLANS INDICATE 200A'S EXISTING AND RISER | | | SHOWS 150A. | | | PLEASE INDICATE THE SIZE OF THE SERVICE ENTRANCE | | | CONDUCTORS IN THE EXISTING RISER. CAN NOT VERIFY THE | | | SEC'S AT THIS TIME. (NONE SHOWN) | | | 215.5, 310.16, 240.4 ETC | | | FBC 106.1.2 | | | | | | 10) NOTE: NO, PLEASE SEE RESPONSE LETTER DOES NOTE | | | RESPOND TO THIS COMMENT, IT SEEMS TO REPLY TO #11. ? | | | PLEASE SEE THE SECTIONS GIVEN AS THE LOAD | | | SUMMARY/CALCULATIONS ARE STILL NEEDED FOR REVIEW. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SUBMIT THE LOAD CALCULATIONS BASED ON THE NEC | | | 220.3, 220.10, 220.11, 220.13 AND CONTINUOUS LOADS AT | | | 125% 215.3, 230.42 ETC. | | | | | | 11) NOTE: NO, THIS WAS IN RESPONSE LETTER AS COMMENT | | | #10; HOWEVER PLEASE SEE THE ONLY AIC RATING WHICH COULD | | | BE LOCATED ON E-2.0 WAS THE RATING FOR THE BRANCH | | | BREAKERS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE INDICATE THE AIC RATINGS FOR ALL SERVICE | | | EQUIPMENT. PLANS INDICATE THE RATINGS FOR THE BRANCH | | | BREAKERS ONLY ON THE PANEL SCHEDULE. | | | PLEASE SEE 110.9, 240.12 | | | FBC 106.1.2 ADMIN SECT. | | | | | | 12) NOTE: OK. | | | | | | | | | *** NEW NOTES *** | | | | | | 13) NOTE: PLEASE INDICATE ALL CIRCUITING ON PLANS AND | | | CORRELATE WITH THE SUBMITTED PANEL SCHEDULE. 106.1.2, | | | 106.3.5.1.2 | | | NEC 408.4, 310.16, 240.4 | | | | | | 14) NOTE: PLEASE SUBMIT ENERGY CALCULATIONS FOR SPACE | | | PER CHAPTER 13 OF TEH FBC 2004. 13-415.1.AB.1 | | | THIS WAS NOT REQUESTED ON THE PREVIOUS REVIEW, HOWEVER | | | DUE TO NEW STORE FRONT, OCCUPANCY, SPACE NOT CURRENTLY | | | OCCUPIED , REMOVAL OF WALLS, NEW CEILING, NE INSULATION | | | ETC, CALCULATIONS FOR LIGHTING ETC WILL BE NEEDED. | | | PLEASE SEE MECHANICAL COMMENTS AS THE PLANS INDICATE | | | NEW SPACE BEING INTRODUCED FOR CONDITIONING FROM AN | | | EXISTING A/C SYSTEM. | | | PLEASE SEE NOTE ON ARCHITECTURAL SHEETS WHICH MENTIONS | | | NEW A/C WORK. PLEASE CLARIFY. | | | | | | 15) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | | REPEAT COMMENTS FOR CODE COMPLIANCE. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-11-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-21 |
Time |
07:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-20 |
Time |
20:17 |
Sent To |
|
|
| Notes |
| 2006-11-21 07:44:59 | *** UNSAT *** | | | | | | 1) NOTE: PLEASE SEE PLANS REFLECT THE 2001 FBC; HOWEVER | | | AS OF OCT 1ST, 2005 THE STATE OF FLORIDA ADOPTED THE | | | 2004 FBC. PLEASE ADJUST AND CHANGE AS NEED. | | | PLEASE ALSO SEE TWO SEPARATE LS CODES ARE REFERENCED ON | | | PLANS. (2000& 2003). | | | PLEASE SEE OTHER LOCATIONS WHERE THE PLANS REFLECT THE | | | "LATEST ADOPTED" ETC. | | | PLEASE BE SURE THE FOLLOWING CODES ARE REFLECTED ON | | | PLANS AS REQUIRED. | | | 2002 NFPA-70 (NEC), 2003 NFPA-101 (LS), 2004 FBC, AND | | | ANY OTHER CODES FROM OTHER TRADES. SEE COMMENTS FROM | | | OTHER REVIEWERS. | | | | | | 2) NOTE: PLEASE 2004 FBC 13-415.1.ABC.1.1, .1.2 AND | | | .1.3. | | | PLEASE SEE 13-415.1.AB.1, 13-415.2 | | | THIS SPACE APPEARS TO BE IN A BUILDING (BY DEFINITION) | | | LARGER THAN 5K SQ FT AND MEETS OTHER SECTIONS OF THE | | | CODE WHICH INVOKE CHAPTER 13. | | | | | | 3) NOTE: PLEASE INDICATE A NEW OR EXISTING SIGN | | | CIRCUIT(S) PEER 600.5 THIS SPACE AND THE SPACE NEXT | | | DOOR AS SCOPE OF WORK ON ARCHITECTURAL PLANS INDICATE | | | WORK BEING DON ON THE STOREFRONT NEXT DOOR. | | | FBC 106.1.2 ADMIN SECT. | | | | | | 4) NOTE: PLEASE VERIFY THE SCOPE OF WORK BEING DONE ON | | | THE TWO SPACES ADJACENT TO THIS SPACE. SEEMS TO BE | | | INSTALLING NEW STOREFRONT, HOWEVER NO ELECTRICAL IS | | | BEING SHOWN FOR SIGNAGE OR SHOW WINDOW RECEPTS. 600.5, | | | 210.62, 220.12. | | | SUBMIT DETAILS/PLANS. FBC 106.1.2 ADMIN SECTION AS | | | ADOPTED BY THE CITY OF WEST PALM BEACH. | | | | | | 5) NOTE: PLEASE SEE MISSING SHOW WINDOW RECEPTS AS | | | REQUIRED PER 210.62 AND PLEASE ADJUST LOAD CALCULATIONS | | | AS REQUIRED. 220.12 | | | | | | 6) NOTE: PLEASE SEE PLANS APPEAR TO SHOW "COMMON AREA" | | | LIGHTING WHICH IS BEING FED FROM THIS TENANT'S SPACE. | | | PLEASE KNOW THIS IS NOT PERMITTED UNLESS THIS IS INDEED | | | LOCATED ON THIS TENANT'S REAR SECTION OF SPACE. THE | | | OTHER SCENARIO WOULD BE TO SERVE THE COMMON AREA LIGHT | | | FROM A "HOUSE PANEL". | | | 210.25. | | | 230.2. | | | | | | 7) NOTE: PLEASE SEE PLANS DO NOT SEEM TO INDICATE ANY | | | LIGHTING IN THE TOILET AREA. THERE IS A SWITCH; HOWEVER | | | THIS IS NOT SHOWN FEEDING ANYTHING? | | | PLEASE SEE LS 101 7.8 WHICH WILL REQUIRE SOME SORT OF | | | FIXTURE. | | | | | | 8) NOTE: PLEASE SEE COLOR CODING FOR OTHER ELECTRICAL | | | SYSTEM VOLTAGES ARE PRESENT ON PLANS, HOWEVER THERE ARE | | | NO COLOR CODING FOR THE VOLTAGE ACTUALLY BEING | | | INSTALLED. | | | PLEASE SEE SERVICE IS BEING SHOWN AS A 120/240V | | | /HIGH-LEGSERVICE. | | | PLEASE SEE NEC 215.8 | | | | | | 9) NOTE: PLEASE CORRELATE SERVICE AS SHOWN ON PLANS AND | | | THAT OF WHICH IS BEING SHOWN ON RISER. IF SERVICE IS | | | GOING TO BE NEW AS SHOWN ON RISER, PLEASE SHOW. PLEASE | | | VERIFY WHERE THE REST OF THE SERVICE IS FOR FEEDING THE | | | BUILDING. PLEASE SEE 230.2, 230.72 FOR SERVICES | | | PERMITTED, AND GROUPING. | | | PLEASE SEE PLANS INDICATE 200A'S EXISTING AND RISER | | | SHOWS 150A. | | | PLEASE INDICATE THE SIZE OF THE SERVICE ENTRANCE | | | CONDUCTORS IN THE EXISTING RISER. CAN NOT VERIFY THE | | | SEC'S AT THIS TIME. (NONE SHOWN) | | | 215.5, 310.16, 240.4 ETC | | | FBC 106.1.2 | | | | | | 10) NOTE: PLEASE SUBMIT THE LOAD CALCULATIONS BASED ON | | | THE NEC 220.3, 220.10, 220.11, 220.13 AND CONTINUOUS | | | LOADS AT 125% 215.3, 230.42 ETC. | | | | | | 11) NOTE: PLEASE INDICATE THE AIC RATINGS FOR ALL | | | SERVICE EQUIPMENT. PLANS INDICATE THE RATINGS FOR THE | | | BRANCH BREAKERS ONLY ON THE PANEL SCHEDULE. | | | PLEASE SEE 110.9, 240.12 | | | FBC 106.1.2 ADMIN SECT. | | | | | | 12) NOTE: PLEASE SEE PLANS MENTIONS TO PLACE PANEL IN | | | THE STOCKROOM WHICH WILL NOT BE PERMITTED. PLEASE | | | RELOCATE AT THIS TIME. PLEASE SEE 408.7, 240.24, AND | | | 110.26. | | | | | | ** PLEASE KNOW AS THERE ARE MANY ITEMS NOT SUBMITTED OR | | | WILL BE REQUIRED TO BE ADJUSTED, THERE MAY BE COMMENTS | | | ON THE NEXT REVIEW. | | | | | | | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | **PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. **IF | | | THERE ARE ANY QUESTIONS, COMMENTSOR IF ANY OF THE | | | NOTES TYPEDWHICH ARE UNCLEAR IN ANY WAY, PLEASE DO | | | NOT HESITATEIN CONTACTING THIS REVIEWER. | | | | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2006-11-21 06:59:23 | IN PRGRESS | | 2006-11-20 20:28:01 | NOTES TO FOLLOW. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2008-03-10 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-03-10 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-03-10 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2008-03-10 13:21:51 | *****APPROVED***** | | | | | | | | | PLAN SHEETS A-2.0, A-4.0, AND E-1.0 WERE STAMPED, | | | INITIALED, AND APPROVED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2007-11-27 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-11-27 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-11-27 |
Time |
12:29 |
Sent To |
|
|
| Notes |
| 2007-11-27 12:32:22 | ****PROVISO***** | | | | | | ALL COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE | | | BEEN ADDRESSED;HOWEVER THE APPROPIATE PLAN(S) WILL BE | | | STAMPED ALL OTHER PLAN REVIEWS HAVE BEEN SATISFIED. | | | | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-05-07 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-05-07 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-05-07 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2007-05-07 14:41:48 | ****PROVISO***** | | | | | | ALL COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE | | | BEEN ADDRESSED;HOWEVER THE APPROPIATE PLAN(S) WILL BE | | | STAMPED ALL OTHER PLAN REVIEWS HAVE BEEN SATISFIED. | | | | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-02-23 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-02-23 |
Time |
17:39 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-02-23 |
Time |
17:39 |
Sent To |
|
|
| Notes |
| 2007-02-23 17:50:58 | ****UNSAT***** | | | | | | THE FOLLOWING COMMENTS FROM THE PREVIOUS FIRE PLAN | | | REVIEW OF 12/11/2006 STILL NEED TO BE ADDRESSED.ALL | | | OTHERS HAVE BEEN SATISFIED. | | | | | | | | | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.ADD | | | TO GENERAL DEMOLITION NOTES, SHEET A-1.0 | | | | | | 3. SHOW/DISPLAY THE NUMERICAL ADDRESS ON THE BUILDING | | | AT THE APPROPIATE ELEVATION FRONTING SOUTH DIXIE | | | HIGHWAY.IN ADDITION TO THE ADDRESS NUMBERS BEING NO | | | LESS THAN 6 INCHES IN HEIGHT,THE WIDTH OR STROKE OF | | | THOSE NUMBERS SHALL BE NO LESS THAN 1 INCH. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-12-11 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-12-11 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-12-11 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2006-12-11 16:05:57 | *****DENIED***** | | | | | | | | | | | | 1.NFPA 101-2003 EDITION AND THE FLORIDA FIRE | | | PREVENTION CODE-2004 EDITION SHALL BE REFERENCED.SEE | | | SHEET A-2.0 TENANT CALCULATION SECTION. | | | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 3. SHOW/DISPLAY THE NUMERICAL ADDRESS ON THE BUILDING | | | AT THE APPROPIATE ELEVATION FRONTING SOUTH DIXIE | | | HIGHWAY.AS PER WEST PALM BEACH CODE,THE NUMBERS | | | SHALL BE NO LESS THAN 6" IN HEIGHT AND 1" IN WIDTH. | | | HURRICANE SHUTTERS SHALL NOT BLOCK VIEW OF THE | | | NUMERICAL ADDRESS. | | | | | | 4.INTERIOR FINISH FOR WALL AND CEILINGS IN EXITS AND | | | EXIT CORRIDORS SHALL BE CLASS "A" OR CLASS "B". | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-02-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-27 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-27 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2008-02-27 09:33:08 | TO "COMM" BD#53 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-10-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-25 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-25 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2007-11-13 09:41:35 | TO "COMM" BD#56 | | 2007-10-25 11:53:37 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-04-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-23 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-23 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2007-04-23 09:06:52 | TO "COMM" BD#44 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-01-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-19 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-01-19 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2007-01-19 13:02:58 | MOVED TO COMM BOARD #26 | | 2007-01-19 09:17:47 | TO "BOB"#16 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-12-19 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-12-19 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-11-09 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2006-11-20 16:31:35 | TO "BOB"#14 | | 2006-11-09 13:58:56 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2008-02-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-02-29 |
Time |
09:14 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-02-29 |
Time |
09:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2007-11-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-14 |
Time |
11:12 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-11-14 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2007-11-14 11:48:07 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) AS NOTED IN LAST REVIEW 4-30-07. SEE CONDENSER UNIT | | | MOUNTING DETAIL ON PAGE M-2.0. ADD A NOTE STATING, IN | | | COMPLIANCE WITH 2004 FBC 1609 TO WITHSTAND 140 MPH | | | WINDS. | | | | | | 2) NEED TO SUBMIT THE TECHNICAL DRAWINGS WITH THE | | | NOTICE OF ACCEPTANCE FOR THE 12X12 O.A. LOUVER, SEE FS | | | 553.842(1) AND FAC 9B-72.010(31)(C). | | | | | | 3) IF THE NOA 06-0602.04 FOR THE 12X12 LOUVERS HAS A | | | PRODUCT APPROVAL FROM THE STATE OF FLORIDA PLEASE | | | ATTACHE COVER SHEET. | | | | | | 4) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | (A SHOP REVIEW STAMP AND SIGNATURE ON EACH PRODUCT | | | APPROVAL WILL MEET THIS REQUIREMENT). | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-04-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-04-30 |
Time |
15:56 |
Rev Time |
0.35 |
| Received By |
tgordon |
Date |
2007-04-30 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2007-04-30 16:06:15 | *** DENIED *** | | | 1) SEE CONDENSER UNIT MOUNTING DETAIL, PLEASE ADD, IN | | | COMPLIANCE WITH 2004 FBC 1609 TO WITHSTAND 140 MPH | | | WINDS. | | | | | | 2) PLEASE SUBMIT PRODUCT APPROVAL FOR12X12 O.A. LOUVER, | | | SEE FS 553.842(1) AND FAC 9B-72.010(31)(C). | | | | | | **PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT | | | IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT | | | HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR | | | LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-01-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-01-22 |
Time |
12:17 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-01-22 |
Time |
12:17 |
Sent To |
|
|
| Notes |
| 2007-01-22 12:23:28 | *** DENIED *** | | | 1) PLANS COVER SHEET STATES HVAC IS EXISTING NO NEW | | | WORK. SEE PLAN A-4.0 HIGHLIGHTED NOTE STATING "REPLACE | | | EXISTING A/C DUCTWORK". | | | | | | 2) NO MECHANICAL PLANS WERE SUBMITTED FOR REVIEW. | | | PLEASE SUBMIT MECHANICAL PLANS FOR REVIEW, PER 2004 FBC | | | WPB AMEND. 106.3.5.1.4. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-01-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-11-27 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2007-01-22 |
Time |
12:15 |
Sent To |
|
|
| Notes |
| 2006-11-27 09:01:22 | NO MECHANICAL PLANS SUBMITTED, AND NO | | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | | THIS TIME. | | | | | | SEE REVIEW NOTES 1-22-07. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-05-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-05-03 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-05-03 |
Time |
14:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-02-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-02-03 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-02-03 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2007-02-03 14:54:36 | DENIED; | | | PLUMBING REVIEW COMMENTS ON 12/19/06 WERE NOT | | | ADDRESSED; | | | 1. (SECOND REQUEST) PAGE A-1.0 SANITARY PLUMBING PIPES | | | TO BE REMOVED BACK TO THE BUILDING DRAIN. NO DEAD ENDS | | | PERMITTED IN THE DRAINAGE SYSTEM. FBC-2004 PLUMBING | | | SECTION704.5. ADD NOTE TO DEMO PLAN "ALL PLUMBING DEMO | | | WORK TO BE DONE BY A LICENSED PLUMBING CONTRACTOR | | | PERMIT AND INSPECTIONS REQUIRED". | | | 2. (SECOND REQUEST) PAGE A-3.0 SANITARY RISER DIAGRAM. | | | FUTURE SINKBRANCH DRAIN TO BE INSTALLED DOWN STREAM | | | OF THE BATHROOM GROUO. SECTION 909.1. | | | 3. (SECOND REQUEST) PER TABLE 403.1 (6) M MINIMUM | | | NUMBER OF FIXTURES REQUIRED, A DRINKING FOUNTAINIS | | | REQUIRED. THE DRINKING FOUNTAIN MUST MEET THE | | | REQUIREMENTS OF FBC-2004 BUILDING CHAPTER 11 SECTION | | | 11-4.1.3(10) HANDICAP AND FOR PEOPLE WITH BAD BACKS. | | | SECTION 11-4.15.2 SPOUT HEIGHT, 11-4.15.3 SPOUT | | | LOCATION, 11-4.15.4 CONTROLS, AND 11-4.15.5 CLEARANCES. | | | SHOW ELEVATION ON DRAWINGS. | | | 4. (SECION REQUEST) PAGE A-3.0 WATER RISER DIAGRAM AIR | | | CHAMBERS ARE NOT AN ENGINEER PRODUCT. REMOVE THE PLANS. | | | WATER HAMMER ARRESTORS CAN BE INSTALLED AS REQUIRED PER | | | SECTION 604.9 LIST MANUFACTURE AND MODEL NUMBER. WATER | | | HAMMER ARRESTORS ARE TO BE INSTALL PER MANUFACTURE | | | INSTALLATION INSTRUCTIONS AS CLOSE TO THE FIXTURE AS | | | PERMITED NOT IN THE CEILING. | | | 5. (NEW COMMENTS) PLANS ARE BEING REVIEWED UNDER THE | | | 2004 CODE CORRECT UNDER GENERAL NOTES. | | | 6. (NEW COMMENT) PAGE A-3.0 BATHROOM WALL FINISH PAINT | | | IS NOT A HARD SURFACE. SEE 2004 BUILDING SECTION | | | 12.10.2 | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-12-19 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-12-19 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-12-19 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2006-12-19 14:29:41 | DENIED; | | | 1. PAGE A-1.0 SANITARY PLUMBING PIPES TO BE REMOVED | | | BACK TO THE BUILDING DRAIN. NO DEAD ENDS PERMITED IN | | | THE DRAINAGE SYSTEM. FBC-2004 SECTION 704.5. PLEASE ADD | | | NOTE TO DEMO. PLAN, "ALLPLUMBING DEMO WORK TO BE DONE | | | BY A LICENSED PLUMBING CONTRACTOR PERMIT AND | | | INSPECTIONS REQUIRED". | | | 2. PAGE A-3.0 SANITARY RISER DIAGRAM. FUTURE SINK | | | BRANCH DRAIN TO BE INSTALLED DOWN STREAM OF THE | | | BATHROOM GROUP. SECTION 909.1. | | | 3. PER TABLE 403.1 (6) M MINIMUM NUMBER OF FIXTURES | | | REQUIRED, A DRINKING FOUNTAIN IS REQUIRED. THE DRINKING | | | FOUNTAIN MUST MEET THE REQUIREMENTS OF FBC-2004 | | | BUILDING CHAPTER11 SECTIONS 11-4.1.3(10). HANDICAP | | | AND PEOPLE WITH BAD BACKS. SECTION 11-4.15.2 SPOUT | | | HEIGH. SECTION 11-4.15.3 SPOUT LOCATION, SECTION | | | 11-4.15.4 CONTROLS, SECTION 11-4.15.5 CLEARANCES. | | | PLEASE SHOW ELEVATION ON DRAWINGS. | | | 4.PAGE A-3.0 WATER RISER AIR CHAMBERS ARE NOT AN | | | ENGINEER PRODUCT. PLEASE REMOVE FROM PLANS. WATER | | | HAMMER ARRESTORS CAN BE INSTALLED AS REQUIRED BY | | | SECTION 604.9. LIST MANUFACTURE AND MODEL NUMBER. WHA'S | | | ARE TO BE INSTALLED PER MANUFACTURE INSTALLATION | | | INSTRUCTIONS, AS CLOSE TO THE SOURCE OF HAMMERAS | | | PERMITED NOT IN THE CEILING. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
X |
PERMIT EXTENSION |
| Rev No |
1 |
Status |
N |
Date |
2008-09-29 |
|
|
Cont ID |
|
| Sent By |
amckenzi |
Date |
2008-09-29 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
amckenzi |
Date |
2008-09-29 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2008-09-29 08:16:06 | PERMIT APPLICATION EXTENDED TO 12/27/08 PER RAB/AMM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2008-03-04 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2008-03-04 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2008-03-04 |
Time |
09:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-12-02 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2007-12-02 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2007-12-02 |
Time |
14:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-04-25 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2007-04-25 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2007-04-25 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2007-04-25 11:13:39 | ZONING REVIEW: PASSED | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2007-01-29 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2007-01-29 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2007-01-29 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2007-01-29 13:35:43 | ZONING REVIEW: PASSED | | | | | | - REVIEWED FOR EXTERIOR RENOVATIONS | | | | | | MATT FLIS 822-1445 | | 2007-01-19 13:02:10 | NEEDS FOR DDA |
|
|
|