Plan Review Details - Permit 06110260
Plan Review Stops For Permit 06110260
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status N Date 2007-02-07 Cont ID  
Sent By dpalmer Date 2007-02-07 Time 16:17 Rev Time 0.00
Received By dpalmer Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-02-07 Cont ID  
Sent By dpalmer Date 2007-02-07 Time 16:21 Rev Time 0.00
Received By dpalmer Date 2007-02-07 Time 16:20 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-11-17 Cont ID  
Sent By dpalmer Date 2006-11-17 Time 16:58 Rev Time 0.00
Received By dpalmer Date 2006-11-17 Time 16:34 Sent To  
Notes
2006-12-24 16:21:03PLANS WERE REVIEWED ON 11/17/06, THESE HAVE NOT BEEN
 RESUBMITTED.
2006-11-17 16:59:36*** UNSAT ***
  
 1) NOTE: PLEASE SEE THE PERMIT APPLICATION SUBMITTED
 WAS SUBMITTED BY AN ELECTRICAL CONTRACTOR WHEREAS
 SCOPES OF WORK SUBMITTED ON PLANS ARE FOR OTHER TRADES
 WHICH AN ELECTRICAL CONTRACTOR CAN NOT PERFORM. PLEASE
 CLARIFY SCOPE AS APPLIED FOR AS PLANS INDICATE
 INSTALLATION OF NEW CONCRETE SUPPORTS (TYP) ON "M"
 SHEETS, HOWEVER NOT ON "S' SHEETS? SEE BUILDING REVIEW
 NOTES.
 FS 489
  
 2) NOTE: PLEASE SEE VALUE ON PLANS FOR SCOPE OF WORK
 SUBMITTED SHALL INCLUDE ALL LABOR AND MATERIALS EVEN IF
 EQUIPMENT/MATERIALS IS OWNER SUPPLIED.
 FBC 108.3
  
 3) NOTE: PLEASE SEE ADDRESS ON TITLE BLOCKS FOR CAMP,
 DRESSER & MCKEE INC, DOES NOT CORRELATE WITH THE
 STATE'S WEBSITE. PLEASE OBTAIN WRITTEN DOCUMENTATION
 FROM THE DEPARTMENT OF BUSINESS AND PROFESSIONAL
 REGULATION THAT THE ADDRESS AS SHOWN LOCALLY IS OK,
 WHICH DOES NOT CORRESPOND TO THE STATE'S TAMPA
 ADDRESS.
  
 OPT#2, PLEASE ADJUST TITLE BLOCKS TO REFLECT THE
 ADDRESS AS LISTED ON STATE'S WEBSITE. PLEASE SEE THAT I
 HAVE ATTACHED A PRINT FROM THE STATE DBPR'S WEBSITE
 WHICH REFLECTS THIS.
  
  
  
  
 ** ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 **PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW.**IF
 THERE ARE ANY QUESTIONS, COMMENTSOR IF ANY OF THE
 NOTES TYPEDWHICH ARE UNCLEAR IN ANY WAY, PLEASE DO
 NOT HESITATEIN CONTACTING THIS REVIEWER.
  
  
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 2 Status N Date 2007-02-07 Cont ID  
Sent By dpalmer Date 2007-02-07 Time 16:18 Rev Time 0.00
Received By dpalmer Date   Time   Sent To  
Notes
2007-02-07 16:20:04ENGINEERING UNDER OTHER PERMIT, THIS IS ELEC SCOPE
 ONLY.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2006-11-18 Cont ID  
Sent By rchokshi Date 2006-11-18 Time 08:51 Rev Time 0.00
Received By rchokshi Date 2006-11-18 Time 08:40 Sent To  
Notes
2006-11-18 08:50:42PLEASE TELL US ABOUT,ARE YOU PUTTING NEW OR CHANGING
 ANY DRAINAGE/STORM WATER SYSTEM?MAKING ANY SOIL
 PERVIOUS TO IMPERVIOUS SOIL? CHANGING ANY OR PUTTING
 ANY NEW SIDEWALK, DRIVEWAY, HANDICAP PARKING, DUMPSTER
 ENCLOSURE, ETC., ?? PLEASE TELL US IN MORE DETAIL
 EXACTLY WHAT YOU ARE DOING FOR STORM WATER/ DRAINAGE
 SYSTEMCONTROL STRUCTURE, ETC.
  
 RASIK CHOKSHI 805-6723
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-02-06 Cont ID  
Sent By adarroug Date 2007-02-06 Time 13:33 Rev Time 0.00
Received By adarroug Date 2007-02-06 Time 13:33 Sent To E
Notes
2007-02-06 13:33:47TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-01-06 Cont ID  
Sent By kstevens Date 2007-01-06 Time 17:44 Rev Time 0.00
Received By kstevens Date 2006-11-12 Time 10:16 Sent To  
Notes
2006-11-14 08:40:18TO "COMM" BD#18
2006-11-12 10:17:14WAITING FOR "COMM" BD

Review Stop P PLUMBING
Rev No 1 Status N Date 2007-01-06 Cont ID  
Sent By kstevens Date 2007-01-06 Time 17:43 Rev Time 0.00
Received By kstevens Date 2007-01-06 Time 17:43 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2006-11-30 Cont ID  
Sent By jroach Date 2006-11-30 Time 15:26 Rev Time 0.00
Received By jroach Date 2006-11-30 Time 15:26 Sent To  
Notes
***NONE***