| Plan Review Stops For Permit 06110215 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-10-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-10-16 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-10-16 |
Time |
17:14 |
Sent To |
|
|
| Notes |
| 2007-10-16 17:15:03 | PRODUCT APPROVALS OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-05-09 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-05-09 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-05-09 |
Time |
11:02 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-04-12 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-04-12 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-04-12 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2007-04-12 16:03:18 | | | | BUILDING REVIEW COMMENTS | | | | | | | | | | | | 1] | | | PRODUCT APPROVALS WERE NOT PROVIDED FOR THE STRAPS AND | | | TIE DOWNS. | | | | | | 2] | | | SHOW SAFETY GLAZING AT TUB LOCATION RIGHT SIDE | | | ELEVATION. | | | | | | 3] | | | PROVIDE SMOKE ALARMS PER SECTION R313.1, FBC | | | RESIDENTIAL CODE. | | | | | | 4] | | | NOTICE OF COMMENCEMENT HAS EXPIRED (90 DAYS), PLEASE | | | RE-CERTIFY. | | | | | | | | | | | | | | | | | | | | | | | | L.MARTINEZ | | | 561-805-6710 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-11-28 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-11-28 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-11-28 |
Time |
08:34 |
Sent To |
|
|
| Notes |
| 2006-11-28 09:09:29 | DENIED | | | | | | | | | 1.SHOW SIZE AND LOCATION OF ATTIC ACCESS COMPLYING | | | WITH R-806. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.BASED ON ICC BUILDING VALUATION DATA THE PERMIT | | | VALUE HAS BEEN REVISED TO $240,797.00.ADDITIONAL | | | PERMIT FEES ARE DUE. | | | | | | 4.SAFTEY GLAZING REQUIRED FOR WINDOWS AT TUB | | | LOCATIONS.R-308.4 | | | | | | 5.PRODUCT APPROVALS REQUIRED FOR LINTELS, STRAPS AND | | | TIE-DOWNS AND MULLIONS.OVERHEAD DOOR ONLY STATE | | | PRODUCT APPROVAL SUBMITTED. | | | | | | 6.ALL PRODUCT APPROVALS SUBMITTED WITH QUALITY | | | ASSURANCE SHALL HAVE THE FOLLOWING STATE APPROVAL | | | ATTACHED. | | | | | | PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A STATE PRODUCT APPROVAL SHEETS THAT | | | LISTS THE PRODUCT IDENTITY NUMBER FROM THE STATE. IF | | | THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT AN | | | APPLICATION FOR LOCAL PRODUCT APPROVAL OR SITE SPECIFIC | | | FORM PER RULE 9B-72. SEE ATTACHMENT. | | | WWW.FLORIDABUILDING.ORG | | | | | | 7.THOSE PRODUCT APPROVALS WHICH ARE REGULATED BY DCA | | | RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL.WPB AMENDMENT TO FBC 106.3.3. | | | | | | | | | 8.SUBMIT TWO SETS OF TRUSS DRAWINGS FOR REVIEW PER | | | 2004 FBC R-802.10.1TRUSS DRAWING REQUIRED TO BE | | | APPROVED PRIOR TO INSTALLATION. | | | | | | 9.SHOW PRESSURES ON DOOR AND WINDOW OPENINGS. | | | | | | 10.R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS | | | TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO | | | DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE | | | GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM | | | OF 6 INCHESWITHIN THE FIRST 10 FEET. | | | | | | 11.SUBMIT A WINDOW, LINTEL AND SHUTTER SCHEDULE. | | | | | | 12.SHOW DIMENTIONS ON ELEVATIONS. | | | | | | 13.SMOKE DETECTORS FOR BEDROOMS SHALL COMPLY WITHR | | | 313.1 | | | | | | 14.ENGINEERS SEAL IS EXPIRED AND SHOULD READ | | | "LICENSED"61G1-16.001 | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. SUBMIT ONE | | | COPY OF OLD PAGES FOR REFERENCE . A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH A | | | DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DEPARTMENT | | | 561-805-6672 | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-08-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-22 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-22 |
Time |
14:10 |
Sent To |
PC |
|
| Notes |
| 2007-08-22 14:31:51 | STAMP REVISION. | | | THE SIGNED COPY BY THE CONTRACTOR IS ON FILE. COPY FOR | | | FEILD WAS NOT SIGNED BY CONTRACTOR FOR THEIR OWN | | | RECORD. CONTRACTOR TO SIGN HIS COPY. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-05-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-05-16 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-05-16 |
Time |
15:51 |
Sent To |
M |
|
| Notes |
| 2007-05-16 17:01:03 | *** PROVISO/REVISION *** | | | | | | 1) NOTE: PLEASE SEE THE MICROWAVE AS SHOWN ON PANEL | | | SCHEDULE IS NOT SHOWN OR FIGURED INTO LOAD | | | CALCULATIONS. | | | PLEASE ADJUST AND UPDATE. 220, 408.4. | | | FBC 106.1.2, 106.3.5.4 | | | | | | 2) NOTE: PLEASE SEE THE DINING ROOM CIRCUIT WHICH IS | | | BEING SHOWN AS 15AMP, WHEN 210.52B1, 210.11C1 REQUIRES | | | THIS AS A 20AMP CIRCUIT. | | | | | | 3) NOTE: PLEASE CORRECT ANY CIRCUITING ON PLANS AND | | | CORRELATE WITH THE PANEL SCHEDULE. PLEASE SEE SOME | | | CIRCUITS SHOWN, SOME NOT, AND SOME OF THE SHOWN | | | CIRCUITS DO NOT CORRELATE WITH THE SUBMITTED PANEL | | | SCHEDULE. 408.4 | | | | | | ** PLEASE SUBMIT THE ABOVE CORRECTIONS ALONG WITH ANY | | | OTHER REVISIONS BEFORE ANY ROUGH ELECTRICAL | | | INSPECTION. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-04-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-04-21 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-04-21 |
Time |
06:50 |
Sent To |
P |
|
| Notes |
| 2007-04-21 07:46:48 | *** UNSAT 3RD REVIEW *** | | | | | | ** IMPORTANT** | | | THE REVIEW PROCESS HAS BEEN STOPPED AND PLANS HAVE BEEN | | | PLACED OUT FRONT UNTIL THE RE-SUB FEE IS PAID. ALL FEES | | | ARE DUE AT THE TIME OF SUBMITTING PLANS. THIS OFFICE | | | HAS INFORMED THE CONTRACTOR OF THIS ON SEVERAL | | | OCCASIONS. THE FEE OF $290.80 MUST BE PAID BEFORE PLANS | | | CONTINUE THE ROUTING/REVIEW PROCESS. | | | | | | ** PLEASE SEE THERE ARE SOME COMMENTS FROM PREVIOUS | | | REVIEWS WHICH ARE STILL NOT DONE. | | | | | | 1) NOTE: THIS WAS THE SAME NOTE ON PREVIOUS REVIEW. | | | PLEASE SEE THAT THE PLANS WHEN FALLING UNDER THE | | | EXCEPTIONS OF THE FLORIDA STATUTES FOR A SF RESIDENCE | | | MUST STILL CONTAIN A *PRINTED NAME* AND *SIGNATURE* OF | | | THE PERSON TAKING RESPONSIBILITY OF PLANS. | | | FS 471.003, 481.229, 489 | | | FBC 106.1.2 | | | | | | 2) NOTE:PLEASE SEE THIS IS THE SAME NOTE FROM | | | PREVIOUS REVIEWS. MANY ITEMS WERE CHANGED HOWEVER NOT | | | ALL. | | | PLEASE SEE THAT THERE ARE LOADS WHICH ARE SHOWN ON THE | | | PANEL SCHEDULE WHICH DO NOT CORRELATE WITH THE LOAD | | | CALCULATIONS. PLEASE CORRELATE AND SEE THE NEC FOR ALL | | | MINIMUM LOADS TO BE SHOWN AND FIGURED FOR DEDICATED | | | CIRCUITS AND APPLIANCE LOADS. | | | PLEASE SEE STILL MISSING : | | | MICROWAVE | | | POOL PUMP | | | EVEN IF THESE ITEMS ARE SHOWN AS OPTIONAL, THEY WOULD | | | STILL BE FIGURED INTO THE LOAD CALCULATIONS. | | | NEC 220. | | | FBC 106.3.5.4 | | | | | | 3) NOTE: SAME NOTE AS TWO PREVIOUS REVIEWS. | | | THIS LEADS DIRECTLY INTO THE FOLLOWING COMMENT. | | | PLEASE SEE MISSING BATH DEDICATED CIRCUIT(S). 210.52D, | | | 210.11C3 | | | PREVIOUS NOTES. | | | | | | 4) NOTE:PLEASE SEE THE TWO PREVIOUS REVIEWS REQUESTED | | | A DETAILED PANEL SCHEDULE AS REQUIRED BY THE CODE. | | | PLEASE SEE THAT THE PANEL SCHEDULE SHOWN IS MOSTLY SET | | | UP AND LOAD CALCULATIONS. PLEASE KNOW THAT A PANEL | | | SCHEDULE MUST SHOW ALL MINIMUM CIRCUITS (NOTE #3) | | | PLEASE SEE IF A PANEL SCHEDULE STILL INDICATES A | | | CERTAIN AMOUNT OF CIRCUITS AS GENERAL LTS, GENERAL | | | RECEPTS, THEN THE MINIMUM REQUIRED DEDICATED CIRCUITS | | | AS NOTED FOR NOTE #3 ABOVE, AND OTHER AREAS AS NOTED ON | | | THE PREVIOUS REVIEW FOR DINING ROOM ETC CAN NOT BE | | | VERIFIED. | | | PLEASE COMPLETE. IT IS KNOWN THAT THESE ITEMS MAY BE | | | CHANGED DURING CONSTRUCTION, HOWEVER THE *MINIMUM* IS | | | REQUIRED BY CODE TO BE SHOWN. | | | PLEASE SEE THAT THE PANEL SCHEDULE FOR ALL CIRCUITS | | | SHALL BE SPECIFIC AS REQUESTED ON PREVIOUS REVIEW. | | | PLEASE SEE THE FOLLOWING TEXT IS TAKEN DIRECTLY FROM | | | THE NEC CODE COMMENTARY. | | | | | | *CODE TO REQUIRE THAT THE IDENTIFICATION FOR EVERY | | | CIRCUIT SUPPLIED BY A PANEL-BOARD OR SWITCHBOARD BE | | | LEGIBLE AND CLEARLY STATE THE SPECIFIC PURPOSE FOR | | | WHICH THE CIRCUIT IS USED. CIRCUITS USED FOR THE SAME | | | PURPOSE MUST BE IDENTIFIED AS TO THEIR LOCATION. FOR | | | EXAMPLE, SMALL APPLIANCE BRANCH CIRCUITS CAN SUPPLY | | | OUTLETS IN THE KITCHEN, DINING ROOM, AND KITCHEN | | | COUNTERTOPS. IDENTIFYING THE CIRCUITS AS SMALL | | | APPLIANCE BRANCH CIRCUITS IS NOT ACCEPTABLE; INSTEAD, | | | THEY SHOULD BE IDENTIFIED AS ``KITCHEN WALL | | | RECEPTACLES,'' ``DINING ROOM FLOOR RECEPTACLE,'' OR | | | ``KITCHEN COUNTERTOP RECEPTACLES LEFT OF SINK.'' | | | CIRCUIT DIRECTORIES CONTAINING MULTIPLE ENTRIES WITH | | | ONLY ``LIGHTS'' OR ``OUTLETS'' DO NOT PROVIDE THE | | | SUFFICIENT DETAIL REQUIRED BY THIS SECTION.* 408.4, | | | 310.16, 240.4 ETC | | | FBC 106.3.5.4 | | | | | | 5) NOTE: AS NOTED ON PREVIOUS REVIEWS AND AS THE PANEL | | | SCHEDULE IS NOT COMPLETE AT THIS TIME THE MINIMUM | | | CIRCUITS AND LOADS CAN NOT BE VERIFIED AT THIS TIME. | | | PLEASE SEE 210.52B1, 210.11C1, 220.16 FOR ALL MINIMUM | | | LOADS FOR ONE OR MORE OF THE SMALL APPLIANCE CIRCUITS. | | | THE DINING ROOM, BREAKFAST ROOMS/AREAS ARE ALSO | | | CONSIDERED IN THIS REQUIREMENT AS STATED IN 210.52B1. | | | PLEASE SEE THE TOTAL OF 1500VA IS TO BE SHOWN FOR EACH | | | OF THESE DEDICATED CIRCUITS. PLEASE INDICATE HOW THE | | | DINING ROOM RECEPTACLES AND BREAKFAST AREA RECEPTACLES | | | ARE BEING FED. PLEASE BE SURE TO ADJUST ANY LOAD | | | CALCULATIONS AS NEEDED. | | | PLEASE CORRELATE AND ADJUST. | | | | | | 6) NOTE:PLEASE SEE PREVIOUS REVIEW GAVE A NOTICE TO | | | THIS SECTION OF THE FLORIDA STATUTES WHICH REQUIRES A | | | LOCAL JURISDICTION TO ASSESS A FEE WHEN *ANY* OF THE | | | SAME REPEAT CODE COMPLIANT COMMENT IS MADE THREE OR | | | MORE TIMES THIS FEE IS ASSESSED AS REQUIRED. A FEE OF | | | $3,489.56 IS DUE UPON RE-SUBMITTAL OF PLANS. | | | AS STATED IN THE TWO PREVIOUS REVIEWS, IF THERE ARE ANY | | | QUESTIONS TO PLEASE CONTACT THIS OFFICE TO GO OVER | | | COMMENTS. | | | PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO DESIGN | | | PROFESSIONALS AND REPEAT COMMENTS FOR CODE COMPLIANCE. | | | PLEASE SEE THERE ARE SOME COMMENTS WHICH ARE THE SAME | | | FROM PREVIOUS REVIEW. THIS IS ONLY GIVEN AS A NOTICE AT | | | THIS TIME. | | | PLEASE GO THROUGH ALL NOTES CAREFULLY AND ADJUST | | | PLANS. | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-03-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-21 |
Time |
07:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-20 |
Time |
20:18 |
Sent To |
M |
|
| Notes |
| 2007-03-21 07:41:14 | NOTE ADDED, PLEASE SEE THE NOTICE OF COMMENCMENT HAS | | | SINCE EXPIRED AND IS NOW VOID. FS 713.13(2). | | 2007-03-21 07:36:21 | | | | *** UNSAT 2ND REVIEW *** | | | | | | ** PLEASE SEE THERE ARE SOME COMMENTS FROM PREVIOUS | | | REVIEWS AND MANY NEW COMMENTS AND NEW OR CHANGED | | | ELECTRICAL SHEETS AND INFORMATION IS NOW SUBMITTED OR | | | DIFFERENT ON PLANS SUBMITTED. | | | | | | 1) NOTE: PLEASE SEE THAT THE PLANS WHEN FALLING UNDER | | | THE EXCEPTIONS OF THE FLORIDA STATUTES FOR A SF | | | RESIDENCE MUST STILL CONTAIN A *PRINTED NAME* AND | | | *SIGNATURE* OF THE PERSON TAKING RESPONSIBILITY OF | | | PLANS. | | | FS 471.003, 481.229, 489 | | | FBC 106.1.2 | | | | | | 2) NOTE: PLEASE SEE PLANS STILL INDICATE A MAIN | | | DISCONNECT OUTSIDE ON THE PLANS WHEREAS THE RISER DOES | | | NOT INDICATE ANY MAIN. PLEASE CORRELATE AND KNOW IF A | | | MAIN IS INSTALLED OUTSIDE, THEN AN EQUIPMENT GROUNDING | | | CONDUCTOR WOULD BE REQUIRED FROM THE MAIN TO THE SUB | | | PANEL INSIDE. | | | PLEASE CORRELATE. | | | NEC 215.5, 250.24B, 250.122 | | | FBC 106.1.2, 106.3.5.4 | | | | | | 3) NOTE: PLEASE SEE THAT THERE ARE NUMEROUS LOADS WHICH | | | ARE SHOWN ON THE PANEL SCHEDULE WHICH DO NOT CORRELATE | | | WITH THE LOAD CALCULATIONS. PLEASE CORRELATE AND SEE | | | THE NEC FOR ALL MINIMUM LOADS TO BE SHOWN AND FIGURED | | | FOR DEDICATED CIRCUITS AND APPLIANCE LOADS. | | | PLEASE SEE: | | | SMALL APPLIANCES | | | GARAGE DOOR OPENER, | | | WATER HEATER | | | DRYER, | | | MICROWAVE, | | | DISHWASHER, | | | DISPOSAL, | | | ETC ETC. | | | NEC 220. | | | | | | 4) NOTE: PLEASE SEE MISSING BATH DEDICATED CIRCUIT(S). | | | 210.52D, 210.11C3 | | | PREVIOUS NOTES. | | | | | | 5) NOTE: PLEASE SEE THAT THE PANEL SCHEDULE FOR ALL | | | CIRCUITS SHALL BE SPECIFIC AS REQUESTED ON PREVIOUS | | | REVIEW. | | | PLEASE SEE THE FOLLOWING TEXT IS TAKEN DIRECTLY FROM | | | THE NEC CODE COMMENTARY. | | | | | | *CODE TO REQUIRE THAT THE IDENTIFICATION FOR EVERY | | | CIRCUIT SUPPLIED BY A PANEL-BOARD OR SWITCHBOARD BE | | | LEGIBLE AND CLEARLY STATE THE SPECIFIC PURPOSE FOR | | | WHICH THE CIRCUIT IS USED. CIRCUITS USED FOR THE SAME | | | PURPOSE MUST BE IDENTIFIED AS TO THEIR LOCATION. FOR | | | EXAMPLE, SMALL APPLIANCE BRANCH CIRCUITS CAN SUPPLY | | | OUTLETS IN THE KITCHEN, DINING ROOM, AND KITCHEN | | | COUNTERTOPS. IDENTIFYING THE CIRCUITS AS SMALL | | | APPLIANCE BRANCH CIRCUITS IS NOT ACCEPTABLE; INSTEAD, | | | THEY SHOULD BE IDENTIFIED AS ``KITCHEN WALL | | | RECEPTACLES,'' ``DINING ROOM FLOOR RECEPTACLE,'' OR | | | ``KITCHEN COUNTERTOP RECEPTACLES LEFT OF SINK.'' | | | CIRCUIT DIRECTORIES CONTAINING MULTIPLE ENTRIES WITH | | | ONLY ``LIGHTS'' OR ``OUTLETS'' DO NOT PROVIDE THE | | | SUFFICIENT DETAIL REQUIRED BY THIS SECTION.* 408.4, | | | 310.16, 240.4 ETC | | | FBC 106.3.5.4 | | | | | | 6) NOTE: PLEASE SEE PLANS IN KITCHEN ARE MISSING THE | | | RECEPTACLE OUTLETS FOR THE DISHWASHER AND DISPOSAL. | | | PLEASE SEE THAT THE PANEL SCHEDULE INDICATES THESE ON A | | | 2-POLE BREAKER WHICH WOULD MEANS BOTH ARE BEING SERVED | | | FROM THE SAME YOKE AS STATED IN 210.4, HOWEVER PLANS DO | | | NOT SHOW ANY DEVICES. | | | FBC 106.1.2 | | | | | | 7) NOTE: PLEASE SEE THE SAME AREA OF KITCHEN COUNTER | | | SPACE AS DISH/DISPOSAL IS MISSING GFI RECEPTACLES AS | | | REQUIRED PER 210.52C1. THIS WAS ON PREVIOUS NOTES. SEE | | | REDLINED PLANS. | | | | | | 8) NOTE: PLEASE SEE MISSING RECEPTACLE PER 210.52 IN | | | BEDROOM #2. | | | | | | 9) NOTE: PLEASE SEE 210.52B1, 210.11C1, 220.16 FOR ALL | | | MINIMUM LOADS FOR ONE OR MORE OF THE SMALL APPLIANCE | | | CIRCUITS. THE DINING ROOM, BREAKFAST ROOMS/AREAS ARE | | | ALSO CONSIDERED IN THIS REQUIREMENT AS STATED IN | | | 210.52B1. PLEASE SEE THE SMALL APPLIANCE CIRCUITS AS | | | BEING SHOWN AT 750VA EACH??? PLEASE SEE THE TOTAL OF | | | 1500VA IS BEING SHOWN FOR BOTH ON THE LOAD | | | CALCULATIONS. | | | PLEASE CORRELATE AND ADJUST. | | | | | | 10) NOTE: PLEASE SEE MISPRINT FOR NFPA-70, SHOWS NFPA-7 | | | WHICH IS DIFFERENT CODE. THIS WOULD HAVE BEEN | | | RED-LINED, HOWEVER PLANS ARE COMING BACK FOR OTHER | | | COMMENTS. | | | | | | 11) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | | DESIGN PROFESSIONALS AND REPEAT COMMENTS FOR CODE | | | COMPLIANCE. PLEASE SEE THERE ARE SOME COMMENTS WHICH | | | ARE THE SAME FROM PREVIOUS REVIEW. THIS IS ONLY GIVEN | | | AS A NOTICE AT THIS TIME. | | | PLEASE GO THROUGH ALL NOTES CAREFULLY AND ADJUST | | | PLANS. | | | | | | 12) NOTE: PLEASE SEE PLANS AND PANEL SCHEDULE INDICATE | | | SMOKE DEVICES AS *SD* AND SYMBOL LEGEND HAS THESE AS | | | SMOKE DETECTORS. | | | PLEASE SEENFPA-72 AS THE USE OF SD FOR SMOKE | | | DETECTORS ON PLANS FOR RESIDENTIAL HOMES IS NOT | | | ACCEPTABLE WHEN THESE DEVICES ANY ACTUALLY FALL UNDER | | | THE DEFINITIONS OF SMOKE ALARMS WHICH WOULD BE SHOWN AS | | | SA/SMOKE ALARMS. | | | THIS USE OF SD ON PLANS WAS INGENERAL USED SMOKE | | | DETECTORS AND WAS ALWAYS ACCEPTED HOWEVER AS THERE IS | | | SPECIFIC DIFFERENCE IN THE CODE PLEASE CHANGE PLANS FOR | | | ACTUAL DEIVCES. PLEASE SEE THAT THIS IS NOT A NEW | | | CODE. | | | | | | BY THE DEFINITIONS AS STATED IN NFPA-72 A SD/ SMOKE | | | DETECTOR IS ONLY A DEVICE WHICH WILL DETECT AND WILL | | | NOT SOUND AN AUDIBLE ALARM. THIS WOULD BE DONE BY | | | HORN/SIREN TYPE DEVICES. PLEASE SEE THE DEFINITIONS OF | | | SA/SMOKE ALARMS; THESE ARE DEVICES WHICH ARE 120V (AS | | | SHOWN) AND WOULD DETECT AND SOUND AN ALARM. THIS IS | | | SOMETHING THAT IS NOW BEING COMMENTED ON OTHER REVIEWS | | | FOR OTHER NEW HOMES. | | | ** PLEASE SEE THAT SMOKE ALARMS ARE STATED IN THE FBC | | | RESIDENTIAL CODE/ FBC AND IN NFPA-72. | | | IF THERE ARE ANY QUESTIONS ON THIS COMMENT PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE*. | | | PLEASE SEE NFPA-72 11.5.1.1, 11.8.3 | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-03-20 20:35:43 | 2007-03-20 20:35:43 | | | NOTES TO FOLLOW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-11-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-13 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-13 |
Time |
09:15 |
Sent To |
M |
|
| Notes |
| 2006-11-13 10:12:00 | ****** UNSAT ****** | | | | | | 1) NOTE: PLEASE SEE FAC 61G15-23.001, AS THE SEAL FOR | | | THE ENGINEER OF RECORD IS NO LONGER VALID AS OF JANUARY | | | 1ST, 2006. | | | | | | 2) NOTE: PLEASE SEE SHEETS WHICH DO NOT CONTAIN TITLE | | | BLOCKS FOR SHEETS WHICH DO CONTAIN SEALS FROM THE | | | ENGINEER. PLEASE ALSO SEE SHEETS WHICH ARE SEALED, | | | HOWEVER NOT SIGNED BY THE ENGINEER. PLEASE SEE COMMENT | | | #1, AS ALL SHEETS WILL BE REQUIRED TO BE RE-DONE. FAC | | | 61G15-23.002, FS 471.025 | | | | | | 3) NOTE: PLEASE SEE FS 481.229(C)1 WITH EXCEPTIONS OF | | | WHO CAN DRAW RESIDENTIAL AND WHO SIGN AND SEAL PLANS | | | DONE BY ANOTHER DESIGNER. | | | PLEASE ALSO SEE FS 471.025/481.221 | | | | | | 4) NOTE: PLEASE KNOW THAT NO HAND DRAWN ITEMS MAY BE | | | DONE TO PLANS WHICH ARE SIGNED AND SEALED BY ANY DESIGN | | | PROFESSIONAL. | | | PLEASE SEE BOTH FS 481, AND471. | | | | | | 5) NOTE: PLEASE SEE 210.70 FOR MISSING EGRESS LIGHTING | | | REQUIRED IN SEVERAL LOCATIONS. EGRESS IN AND OUT OF | | | DWELLING, INTO HABITABLE ROOMS ETC. PLEASE SEE LIGHT | | | FIXTURES OF SOME SORT WILL BE REQUIRED FOR FINAL. | | | PLEASE ALSO SEE SOME ROOMS ONLY CONTAIN WHAT SEEMS TO | | | BE A FAN. | | | PLEASE SEE LS 101 7.8 | | | | | | 6) NOTE: PLEASE SEE MISSING AIC RATINGS FOR SERVICE | | | EQUIPMENT. 110.9, 240.12, PLEASE SUBMIT. | | | | | | 7) NOTE: PLEASE SEE MISSING REQUIRED FOOTER STEEL AS | | | PART OF THE GROUNDING ELECTRODE SYSTEM PER 250.50. | | | | | | 8) NOTE: PLEASE PROVIDE ALL ROOM AND AREA DESIGNATIONS | | | ON PLANS AND CORRELATE WITH THE PANEL SCHEDULE(S) | | | SUBMITTED. | | | ALL CIRCUITING SHALL BE SPECIFIC TO ROOMS ETC. EXAMPLE: | | | MASTER BEDRM LTS, KITCHEN LTS , BATH RECEPTS ETC. | | | 240.4,408.4,310.16 | | | FBC 106.1.2 ADMIN SECT. | | | | | | 9) NOTE: PLEASE SEE MISSING DEDICATED BATH(S) | | | CIRCUIT(S) PER 210.52D, 210.11C3. | | | MUST BE 20A AND #12. | | | PLEASE ALSO SEE A ROOM WHICH MENTIONS BEING | | | STORAGE/UTILITY, HOWEVER IF CONTAINING BOTH THE ITEMS | | | SHOWN AS A LAVATORY AND WATER CLOSET, GFI RECEPT AS | | | REQUIRED PER ABOVE SHALL BE INSTALLED. | | | | | | 10) NOTE: PLEASE SEE 424.3B FOR MIN OCP FOR THE AHU. | | | PLEASE SEE A MIN OF 125% BASED ON THE 10KW HEAT. | | | | | | 11) NOTE: PLEASE SEE MISSING COUNTER SPACE RECEPTS PER | | | 210.52C1 | | | | | | 12) NOTE: PLEASE SEE 210.8A6 AS ALL RECEPTS SERVING | | | KITCHEN COUNTER SPACE SHALL BE GFI/ GFI PROTECTED. | | | | | | 13) NOTE: PLEASE SEE MISSING GFI DESIGNATION ON SEVERAL | | | RECEPTACLE OUTLETS PER THE FOLLOWING. | | | 210.8A2, 210.8A1, 210.8A3 ETC. | | | | | | 14) NOTE: PLEASE SEE NO LOAD INDICATED FOR THE | | | DEDICATED GARAGE DOOR OPENER? | | | CAN NOT REVIEW AT THIS TIME FOR COMPLIANCE FOR SIZING | | | OF OCP AND AWG. | | | 310.16, 240.4, 430? | | | | | | 15) NOTE: PLEASE SEE 210.11C1 AND 220.16 FOR MISSING | | | REQUIRED LOAD FOR SMALL APPLIANCE CIRCUITS. | | | | | | 16) NOTE: PLEASE SEE 210.11C2 AND 220.16 FOR MISSING | | | REQUIRED LOAD FOR LAUNDRY/WASHER CIRCUIT. | | | | | | 17) NOTE: PLEASE SEE SOME AREAS WHICH DO NOT INDICATE | | | 3-WAY SWITCHING WHERE SWITCH LEGS ON PLANS APPEAR TO | | | SHOW THIS?? | | | PLEASE SEE OTHER AREAS WHERE CONTROL FOR EGRESS | | | LIGHTING MAY BE REQUIRED ALSO. | | | 210.70 | | | | | | 18) NOTE: PLEASE SEE NO SYMBOL LEGEND OR SCHEDULE IS | | | SHOWN OR WAS SUBMITTED ON SAID PLANS. | | | PLEASE SUBMIT AND CORRELATE. | | | FBC 106.1.2 ADMIN SECT. | | | | | | 19) NOTE: PLEASE COMPLETE, SUBMIT AND SHOW LOAD | | | CALCULATIONS BASED ON SERVICE AND DWELLING AS SHOWN. | | | PLEASE SEE 220.31. | | | UNABLE TO REVIEW FOR CODE COMPLIANCE AT THIS TIME BASED | | | ON THE FACT THAT NO CALCULATIONS WERE SUBMITTED. | | | | | | 20) NOTE: PLEASE INDICATE AND SHOWN SERVICE AND PANEL | | | LOCATIONS ON PLANS. | | | PLEASE SEE 230.70, 240.24 ETC. AS THE LOCATION WAS NOT | | | SUBMITTED OR SHOWN. | | | | | | 21) NOTE: PLEASE SEE MISSING SMOKE ALARMS AS REQUIRED | | | PER NFPA-72 11.5.1.1, 11.8.3 | | | | | | 22) NOTE: PLEASE BE SURE THE FOLLOWING CODES ARE | | | REFLECTED ON THE PLANS AS SUBMITTED. | | | 2002 NFPA-70 (NEC), 2002 NFPA-72 | | | | | | ** PLEASE KNOW BASED ON THE COMMENTS ON THIS REVIEW, | | | THERE MAY BE FURTHER COMMENTS DUE TO POSSIBLE CHANGES | | | IN PLANS. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-08-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-28 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-28 |
Time |
11:41 |
Sent To |
B |
|
| Notes |
| 2007-08-28 11:41:51 | TO "LMARTINEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-08-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-14 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-14 |
Time |
10:34 |
Sent To |
E |
|
| Notes |
| 2007-08-14 10:35:58 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-07-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-19 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-19 |
Time |
16:00 |
Sent To |
M |
|
| Notes |
| 2007-07-19 16:01:06 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-07-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-11 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-11 |
Time |
13:41 |
Sent To |
M |
|
| Notes |
| 2007-07-11 13:43:37 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-05-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-15 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-15 |
Time |
13:58 |
Sent To |
E |
|
| Notes |
| 2007-05-15 13:58:35 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-04-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-18 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-18 |
Time |
09:16 |
Sent To |
E |
|
| Notes |
| 2007-04-18 09:16:26 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-03-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-19 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-19 |
Time |
11:49 |
Sent To |
E |
|
| Notes |
| 2007-03-19 11:49:37 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-03-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-10 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-10 |
Time |
15:44 |
Sent To |
Z |
|
| Notes |
| 2007-03-10 15:44:33 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-11-28 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-11-28 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-11-09 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2006-11-09 14:32:26 | TO "SFR" "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2007-07-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-20 |
Time |
08:37 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-07-20 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2007-07-20 08:38:31 | REVISION TO MECH. PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-07-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-12 |
Time |
14:14 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-07-12 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2007-07-12 14:15:29 | REVISION TO MECH. PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-05-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-05-17 |
Time |
08:52 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-05-17 |
Time |
08:52 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-05-09 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-05-09 |
Time |
11:30 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-05-09 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2007-05-09 11:30:54 | *** DENIED *** | | | 1) MECHANICAL PLANS PAGE M-1 DO NOT MATCH THE BUILDING | | | FLOOR PLAN PAGE A-1, SEE BATH STORAGE, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-05-02 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-26 |
Time |
11:05 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-03-26 |
Time |
11:05 |
Sent To |
B |
|
| Notes |
| 2007-05-02 09:51:07 | *** DENIED *** | | | 1) MECHANICAL PLANS PAGE M-1 DO NOT MATCH THE BUILDING | | | FLOOR PLAN PAGE A-1, SEE BATH STORAGE, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-11-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-11-13 |
Time |
14:04 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-11-13 |
Time |
14:04 |
Sent To |
P |
|
| Notes |
| 2006-11-13 14:12:05 | *** DENIED *** | | | 1) THE MECHANICAL PLANS NEED THE JOB ADDRESS ON THEM. | | | | | | 2) ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | SHALL BEAR THE PRINTED NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE | | | FOR THE DESIGN. PER FBC 104.2.1 . | | | | | | 3) PLEASE SHOW THE SIZE OF THE SUPPLY AIR DUCTS TO THE | | | DINING ROOM AND THE KITCHEN. | | | | | | 4) WATER CLOSET IN MASTER BATHROOM REQUIRES AN EXHAUST | | | FAN, PER 2004 FBC/R M1506.3. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-05-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-05-21 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-05-21 |
Time |
10:09 |
Sent To |
B |
|
| Notes |
| 2007-05-21 10:16:16 | PROVISO; | | | | | | RISER DIAGRAM TO BE SUBMITED THAT MATCHES THE FLOOR | | | PLAN. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2007-05-02 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-05-02 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-05-02 |
Time |
08:59 |
Sent To |
M |
|
| Notes |
| 2007-05-02 09:14:46 | DENIED; | | | 1. (2ND REQUEST) REMOVE OR CHANGE , PLUMBING NOTE # 1 | | | ON PAGE C-1. PIPES 2 1/2" OR LESS SHALL SLOPE 1/4" PER | | | FOOT SEE SECTION 704.1. | | | 2. WATER HEATER NOT SHOWN ON FLOOR PLAN. | | | 3. PAGE E-1 IS NOT SIGNED OR DATED. STONE ELECTRIC | | | CANNOT DESIGN A PLUMBING SANITARY RISER DIAGRAM. | | | 4. SANITARY RISER DIAGRAM LOOKS LIKE ONE OF THE | | | BATHROOMS IS ON THE 2ND FLOOR OF A ONE STORE HOME. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-03-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-03-27 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-03-27 |
Time |
09:35 |
Sent To |
B |
|
| Notes |
| 2007-03-27 09:41:42 | DENIED; | | | 1. PLUMBING NOTE # 1, HORIZONTAL SLOPE FOR PIPE 2 1/2" | | | AND SMALLER TO BE 1/4" PER FT. TABLE 704.1 PLEASE | | | CHANGE NOTE. | | | 2.ONE SET OF PLANS MARKED IN RED (SANITARY RISER | | | DIAGRAM) CORRECT AS MARKED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-11-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-11-14 |
Time |
07:22 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-11-14 |
Time |
07:22 |
Sent To |
B |
|
| Notes |
| 2006-11-14 07:30:28 | DENIED; | | | NOT ENOUGH INFORMATION TO DO A PLUMBING PLAN REVIEW. | | | PLEASE SUBMIT A SANITARY RISER DIAGRAM TO COMPLY WITH | | | FBC-2004 BUILDING CHAPTER 1 WPB AMENDMENTS SECTION | | | 106.3.5.4. | | | SIZE ALL PIPES, AND RISER DIAGRAM SHOULD MATCH FLOOR | | | PLAN. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-03-16 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-03-16 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-03-16 |
Time |
17:06 |
Sent To |
I |
|
| Notes |
| 2007-03-16 17:09:12 | ***PROVISO*** | | | | | | 1) A SEPARATE PERMIT SHALL BE ACQUIRED FOR INSTALLATION | | | OF ANY FENCE, PRIVACY WALL, ETC. | | | | | | 2) THE A/C EQUIPMENT SHALL BE NO CLOSER THAN SIX (6) | | | FEET TO THE REAR PROPERTY LINE. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-11-11 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-11-11 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-11-11 |
Time |
07:10 |
Sent To |
I |
|
| Notes |
| 2006-11-11 07:16:43 | DENIED, | | | 1. PLEASE SUBMIT TWO COPIES OF SURVEYS, SHOWING THE | | | PROPOSED NSFR WITH SETBACKS (SF11 - SEC 94-73. | | | 2. TWO COPIES OF SURVEYS MUST SHOW THE A/C UNIT WITH | | | SETBACKS. | | | 3. PLEASE PROVIDE THE DIMENSION OF THE PROPOSED | | | DRIVEWAY (WIDTH & LENGTH). NOTE: MUST MAINTAIN 1000SQ | | | FT OR 75% OF | | | LANDSCAPE, WHICHEVER IS LESS WITHIN THE FIRST 25FT | | | FRONT SETBACK. | | | 4. SITEPLAN SUBMITTED HAS INSUFFICIENT INFORMATION FOR | | | A COMPLETE REVIEW. DOES NOT PROVIDE THE SETBACKS (FRONT | | | & REAR). | | | 5. FLOOR PLAN DOES NOT SHOW GARAGE DOOR FOR VEHICLE TO | | | ENTER. PLEASE CLARIFY ON THE PLANS. | | | | | | NOTE: ANY FENCE/GATE/WALL MUST HAVE A SEPARATE PERMIT | | | WITH EASEMENT APPROVAL FROM THE CITY OF WEST PALM BEACH | | | UTILITY DEPT. (UTILITY EASEMENT). | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|